INDOOR UNIT (SINGLE SKIN) INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT

POWER W RUNNING CURRENT - 1 [3] A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL l/s / CFM INDOOR AIR FLOW Pa (in.wg.) INDOOR FAN ESP (H/M/L) SOUND PRESSURE LEVEL (H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT LIQUID mm/in COPPER PIPE SIZE GAS mm/in MODEL

YSB 40B YSL 35D 35,000 10,258 3,493 16.42 220-240/1/50 590 / 1,250 100 / 0.4 53 572 x 892 x 761 852 x 1,030 x 400 50 95 104 9.5 / 3/8 19.1 / 3/4 YSL 40D 40,000 11,723 4,833 [7.27] INDOOR CAP. TUBE

YSB 50B YSL 50D 50,000 14,654 5,457 [9.08] 380-415/3/50 755 / 1,600 100 / 0.4 53

YSB 60B YSL 61D 61,000 17,878 6,672 [10.46]

944 / 2,000 61 572 x 1,502 x 761 85 108 12.7 /

55 104

INDOOR UNIT (SINGLE SKIN) INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT POWER W RUNNING CURRENT - 1 [3] A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL INDOOR AIR FLOW l/s / CFM INDOOR FAN ESP (H/M/L) Pa (in.wg.) SOUND PRESSURE LEVEL (H/M/L) dBA mm UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT INDOOR UNIT kg UNIT WEIGHT OUTDOOR UNIT mm/in LIQUID COPPER PIPE SIZE mm/in GAS MODEL

YSB 80B YDSB 80B MYSS 72C* 70,000 20,516 7,109 [13.58] MYSS 80C 80,000 23,447 8,083 [16.07]

1,180 / 2,500 100 / 0.4 56 572 x 1,502 x 761 946 x 1,300 x 500 92 145 12.7 / 25.4 / 1

YSB 100B YDSB 100B MYSS 100B 100,000 29,308 10,790 [19.38] 380-415/3/50 INDOOR TXV 1,510 / 3,200 100 / 0.4 57

YSB 125B YDSB 125B MYSS 125B 125,000 36,635 11,910 [21.57]

YSB 150B1 YDSB 150B1 MYSS 150C 150,000 43,962 16,211 [31.77]

102 164 28.6 / 11/8

1,982 / 4,200 149 / 0.6 58 885 x 1,640 x 1,040 946 x 939 x 1,116 176 169 15.9 / 5/8 34.9 / 13/8

2,171 / 4,600 149 / 0.6 59 885 x 1,640 x 1,040 1,041 x 939 x 1,116 189 227

High Static Ducted Split

INDOOR UNIT (SINGLE SKIN) INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT POWER W RUNNING CURRENT - 1 [3] A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL INDOOR AIR FLOW l/s / CFM INDOOR FAN ESP (H/M/L) Pa (in.wg.) SOUND PRESSURE LEVEL (H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT LIQUID mm/in COPPER PIPE SIZE GAS mm/in MODEL

YSB 200B2 YDSB 200B2 MYSS 100B x 2 200,000 58,617 20,710 [38.7]

3,021 / 6,400 158 / 0.6 61 945 x 1,894 x 980 (946 x 939 x 1,116) x 2 220 164 x 2 28.6 / 11/8

YSB 300B2 YDSB 300B2 MYSS 150C x 2 300,000 87,925 34,688 [66.50] 380-415/3/50 INDOOR TXV 3,776 / 8,000 4,248 / 9,000 200 / 0.8 200 / 0.8 66 63 1,291 x 1,866 x 1,199 (946 x 939 x 1,116) x 2 (1,041 x 939 x 1,116) x 2 343 343 227 x 2 169 x 2 15.9 / 5/8 34.9 / 13/8 YSB 250B2 YDSB 250B2 MYSS 125B x 2 250,000 73,271 24,510 [44.30]

YSB 350B3 YDSB 350B3 MYSS 100B 350,000 102,579 36,280 [76.57] MYSS 125Bx2

4,956 / 10,500 200 / 0.8 66 1,546 x 2,122 x 1,199 946 x 939 x 1,116 (946 x 939 x 1,116) x 2 440 164 169 x 2 28.6 / 11/8 34.9 / 13/8

INDOOR UNIT (SINGLE SKIN) INDOOR UNIT (DOUBLE SKIN)* OUTDOOR UNIT Btu/h TOTAL COOLING CAPACITY W INPUT POWER W RUNNING CURRENT - 1 [3] A POWER SOURCE V/Ph/Hz REFRIGERANT TYPE / CONTROL INDOOR AIR FLOW l/s / CFM INDOOR FAN ESP (H/M/L) Pa (in.wg.) SOUND PRESSURE LEVEL (H/M/L) dBA UNIT DIMENSION, INDOOR UNIT mm HxWxD OUTDOOR UNIT mm INDOOR UNIT UNIT WEIGHT kg OUTDOOR UNIT LIQUID mm/in COPPER PIPE SIZE GAS mm/in MODEL

YSB 750B5 YSB 500B4 YSB 500B4 YSB 600B4 YDSB 500B4 YDSB 500B4 MYSS 100Bx2 MYSS 125Bx2 MYSS 125B x 4 MYSS 150C x 4 MYSS 150C x 5 500,000 750,000 450,000 600,000 146,542 219,812 131,887 175,850 49,715 89,420 46,855 72,516 [89.34] [169.10] [100.42] [136.68] 380-415/3/50 INDOOR TXV 7,080 / 15,000 7,080 / 15,000 8,496 / 18,000 10,619 / 22,500 5,664 / 12,000 250 / 1.0 250 / 1.0 300 / 1.2 350 / 1.4 200 / 0.8 68 71 70 66 1,546 x 2,274 x 1,466 2,257 x 2,274 x 1,905 1,978 x 2,274 x 1,905 1,546 x 2,274 x 1,466 (946 x 939 x 1,116) x 2 (946 x 939 x 1,116) x 2 (946 x 939 x 1,116) x 4 (1,041 x 939 x 1,116) x 4 (1,041 x 939 x 1,116) x 5 (946 x 939 x 1,116) x 4 564 1,051 991 513 164 x 2 169 x 2 227 x 4 227 x 5 169 x 4 164 x 4 15.9 / 5/8 34.9 / 13/8 28.6 / 11/8 34.9 / 11/8 28.6 / 11/8 YSB 400B4 YDSB 400B4 MYSS100B x 4 400,000 117,233 40,795 [76.1]

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW: COOLING - 26.7C DB / 19.4C WB INDOOR AND 35C DB / 23.9C WB OUTDOOR 4) EER CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ARI 210/240. 5) * FOR PROJECT BASIS 6) INDOOR UNIT DIMENSION, INDOOR WEIGHT, INDOOR AIR FLOW AND INDOOR FAN ESP IS FOR SINGLE SKIN ONLY. 7) ESP ON TABLE ABOVE IS WITHOUT THE FILTER.

www.york.com.my
Johor Tel: 07-557 7788 Pahang Melaka Tel: 06-288 1133 Sabah Negeri Sembilan Tel: 06-768 8969 Tel: 09-567 6778 Tel: 088-722 194

Group Associated (C&L) Sdn Bhd (109719-M)


Head Office: Tel: 03-7718 8388 Fax: 03-7727 4371 Email: sales_enquiry@york.com.my, customer_service@york.com.my
Branches: Penang Tel: 04-331 1670 Perak Tel: 05-548 2307 Sarawak Tel: 082-333 299 Alor Setar

Service Centre:

Kota Bharu Authorized dealer:

Catalogue No: YSB-0212-B

The Trusted Quality And Name In Air-Conditioning

This unprecedented innovation is brought to you by YORK - the trusted name in air-conditioning for quality and reliable after-sales-service. With a nationwide service network. YORK is ever ready to take you to a new dimension in cooling comfort. 100% coil leak test by helium testing method and every components being used in YORK unit are tested, at R&D test lab, which is registered under ISO standard and recognised by Sirim. Copper tubes were tested at burst pressure, where it is at least 3 times the refrigerant operating pressure. Every unit receives a 100% unit run test before leaving the production line in the facrtory, which is registered under ISO standard and recognised by Sirim.
YSB 400B4 /500B4 YSB 750B5

System Features
Modular Combination
YSB 600B4

With only 7 different capacities outdoors, YORK ducted split product range is ranking up to an individual indoor unit at 750kBtu/h.

Insulation

Cabinet Construction

YSB 350B3

Both indoor and outdoor are coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for severe external conditions. Service panel is available at the convenience side for both indoor and outdoor.

Fire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethlene, which is also a type a Closed Cell Foam Insulation (CCF) has offered the following advantages: Durable external surface that resists dirt tough and resilient. Higher degree of puncture resistance when compared to fiberglass. Easily cleaned surface (if necessary) to further resist microbial growth.

YSB 250B2/ 300B2/ 300B3 YSB 200B2

Indoor Air Throw Direction

With the choices of vertical and horizontal air throw make it versatile to various architectual design.

YSB 125B/ 150B

Wide Product Range

Changeable Drive Package

YORK ducted split is offering very wide range of product lineup which is applicable from residential, to light commercial or even commercial use.
YSB 60B/ 80B/ 100B

Non-standard external static pressure & airflow requirement can be sized by changing the factory fitted drive package. (for belt drive model only)

Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration. Indoor Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements.

Components

Easy To Reach Access Valve

Safety Fearures

Discharge line and suction line access valve is accessible without opening the unit casing.
YSB 40B/ 50B

High pressure and low pressure protection Phase sequencer is used to detect for any wrong phase and phase loss during installation and operation. Compressor & motor current overload protection. Minimum compressor's running time to ensure oil return.