Sunteți pe pagina 1din 44

F01S100 V100R001

Product Description

Issue Date

01 2009-10-28

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China http://www.huawei.com support@huawei.com

Website: Email:

Copyright Huawei Technologies Co., Ltd. 2009. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are the property of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but the statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

F01S100 Product Description

Contents

Contents
About This Document.....................................................................................................................1 1 Product Feature...........................................................................................................................1-1
1.1 Prominent Security Performance....................................................................................................................1-2 1.2 Prominent Protection Performance.................................................................................................................1-2 1.3 Easy Installation..............................................................................................................................................1-2 1.4 Prominent Monitoring and Maintainability.....................................................................................................1-3 1.5 Compact and Reliable Structure......................................................................................................................1-4

2 Product Structure........................................................................................................................2-1
2.1 Appearance and Dimensions...........................................................................................................................2-2 2.2 Structure..........................................................................................................................................................2-2 2.3 Power System..................................................................................................................................................2-4 2.3.1 AC PDU.................................................................................................................................................2-6 2.3.2 AC Single-phase Lightning Protection Bar............................................................................................2-7 2.3.3 Battery....................................................................................................................................................2-8 2.3.4 Battery Heater........................................................................................................................................2-9 2.3.5 Remote power supply.............................................................................................................................2-9 2.3.6 DC PDU...............................................................................................................................................2-10 2.4 Cable Distribution Device.............................................................................................................................2-10 2.4.1 MDF.....................................................................................................................................................2-10 2.4.2 ODF......................................................................................................................................................2-12 2.5 Temperature Control Unit.............................................................................................................................2-13 2.6 Monitoring System........................................................................................................................................2-14 2.6.1 Monitoring Scheme..............................................................................................................................2-14 2.6.2 Sensor...................................................................................................................................................2-15

3 System Configuration...............................................................................................................3-1
3.1 F01S100 cabinet Configured with the MA5610.............................................................................................3-2 3.2 F01S100 cabinet Configured with the MA5616.............................................................................................3-2

4 System Parameters.....................................................................................................................4-1 5 Environmental Specifications..................................................................................................5-1 6 Standards Compliance..............................................................................................................6-1


Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. i

Contents

F01S100 Product Description

7 Acronyms and Abbreviations..................................................................................................7-1

ii

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

Figures

Figures
Figure 1-1 The installation of the F01S100 cabinet ............................................................................................1-3 Figure 2-1 Appearance and dimensions of the F01S100 cabinet.........................................................................2-2 Figure 2-2 Structure of the F01S100 cabinet.......................................................................................................2-3 Figure 2-3 Power distribution scheme of the F01S100 cabinet...........................................................................2-5 Figure 2-4 Appearance of battery.........................................................................................................................2-8 Figure 2-5 Appearance of the MDF in the F01S100 cabinet.............................................................................2-11 Figure 2-6 Appearance of the ODF in the F01S100 cabinet..............................................................................2-13 Figure 2-7 Monitoring scheme of the F01S100 cabinet.....................................................................................2-14 Figure 2-8 Appearance of the door status sensor...............................................................................................2-15

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

iii

F01S100 Product Description

Tables

Tables
Table 2-1 Structure of the F01S100 cabinet (configured with the AC-powered MA5610/MA5616).................2-4 Table 2-2 Structure of the F01S100 cabinet (configured with the DC-powered MA5610/MA5616).................2-4 Table 2-3 Specifications of the lightning arrester................................................................................................2-6 Table 2-4 Technical specifications of the maintenance socket............................................................................2-7 Table 2-5 Technical specifications of the AC single-phase lightning protection bar...........................................2-7 Table 2-6 Technical specifications of battery.......................................................................................................2-8 Table 2-7 Technical specifications of the battery heater......................................................................................2-9 Table 2-8 Technical specifications of the remote power supply........................................................................2-10 Table 2-9 Specifications of the MDF in the F01S100 cabinet...........................................................................2-11 Table 2-10 Specifications of the ODF................................................................................................................2-13 Table 2-11 Technical parameters of the heat dissipation fan.............................................................................2-14 Table 3-1 Number of subscribers supported by the F01S100 cabinet in different configurations.......................3-2 Table 3-2 Number of subscribers supported by the F01S100 cabinet in different configurations.......................3-2 Table 4-1 Dimensions of the F01S100 cabinet....................................................................................................4-1 Table 4-2 Weight of the F01S100 cabinet............................................................................................................4-1 Table 4-3 Power of the F01S100 cabinet.............................................................................................................4-1 Table 5-1 Environment specifications of the F01S100 cabinet............................................................................5-1 Table 6-1 Standards compliance of the F01S100 cabinet....................................................................................6-1

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

F01S100 Product Description

About This Document

About This Document


Overview
The F01S100 cabinet can hold the MA5610 and MA5616. The F01S100 cabinet is a smallcapacity device that can provide the LAN, POTS, ADSL2+, and VDSL2 services for the subscriber. This document describes the product feature, product structure, system configurationsystem parametersenvironmental specificationsstandards compliance and acronyms and abbreviations of the F01S100 cabinet.

Related Version
The following table lists the product version related to this document. Product Name MA5610/MA5616 Version V800R307

Intended Audience
The intended audience of this document is:
l l l l l l l

Network planning engineers Installation and commissioning engineers Field maintenance engineers Network monitoring engineers System maintenance engineers Data configuration engineers Application developers

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

About This Document

F01S100 Product Description

Organization
The F01S100 cabinetis an indoor and front access cabinet of a small capacity. The following table lists the contents of the document. Chapter... 1 Product Feature 2 Product Structure 3 System Configuration 4 System Parameters 5 Environmental Specifications 6 Standards Compliance Describes... The security performance, protection performance, installation method, and structure of the F01S100 cabinet. The appearance, structure, and parameters of the F01S100 cabinet, and the functions of the components. The configuration of the F01S100 cabinet. The dimensions, weight, power consumption, configuration and environmental parameters of the F01S100 cabinet. The environmental parameters of the F01S100 cabinet. The standards that the F01S100 cabinet complies with in terms of environment, structure, power system, and lighting protection. The acronyms and abbreviations used in this document.

7 Acronyms and Abbreviations

Conventions
Symbol Conventions
The following symbols may be found in this document. They are defined as follows. Symbol Description Indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Indicates a hazard with a medium or low level of risk which, if not avoided, could result in minor or moderate injury. Indicates a potentially hazardous situation that, if not avoided, could cause equipment damage, data loss, and performance degradation, or unexpected results. Indicates a tip that may help you solve a problem or save your time.

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

About This Document

Symbol

Description Provides additional information to emphasize or supplement important points of the main text.

General Conventions
Convention Times New Roman Boldface Italic Courier New Description Normal paragraphs are in Times New Roman. Names of files, directories, folders, and users are in boldface. For example, log in as user root. Book titles are in italics. Terminal display is in Courier New.

Command Conventions
Convention Boldface Italic [] { x | y | ... } [ x | y | ... ] { x | y | ... } * Description The keywords of a command line are in boldface. Command arguments are in italic. Items (keywords or arguments) in square brackets [ ] are optional. Alternative items are grouped in braces and separated by vertical bars. One is selected. Optional alternative items are grouped in square brackets and separated by vertical bars. One or none is selected. Alternative items are grouped in braces and separated by vertical bars. A minimum of one or a maximum of all can be selected.

GUI Conventions
Convention Boldface > Description Buttons, menus, parameters, tabs, window, and dialog titles are in boldface. For example, click OK. Multi-level menus are in boldface and separated by the ">" signs. For example, choose File > Create > Folder.

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

About This Document

F01S100 Product Description

Keyboard Operation
Format Key Key 1+Key 2 Description Press the key. For example, press Enter and press Tab. Press the keys concurrently. For example, pressing Ctrl +Alt+A means the three keys should be pressed concurrently. Press the keys in turn. For example, pressing Alt, A means the two keys should be pressed in turn.

Key 1, Key 2

Mouse Operation
Action Click Double-click Drag Description Select and release the primary mouse button without moving the pointer. Press the primary mouse button twice continuously and quickly without moving the pointer. Press and hold the primary mouse button and move the pointer to a certain position.

Update History
Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.

Updates in Issue 01 (2009-10-28)


This is the first release.

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

1 Product Feature

1
About This Chapter

Product Feature

This topic describes the security performance, protection performance, installation method, monitoring, maintenance, and structure of the F01S100 cabinet. 1.1 Prominent Security Performance The F01S100 cabinet features prominent security performance to comply with the international safety standards. 1.2 Prominent Protection Performance The F01S100 cabinet features prominent protection performance to meet the requirements of the outdoor or the indoor environment that does not have any protection. 1.3 Easy Installation The F01S100 cabinet can be installed on the wall, on a pole, or on a concrete pedestal. 1.4 Prominent Monitoring and Maintainability The structure of the F01S100 cabinet meets the requirements of real-time monitoring and easy maintenance. 1.5 Compact and Reliable Structure The compact design of the F01S100 cabinet facilitates the installation of the F01S100 cabinet and ensures that the F01S100 cabinet runs reliably.

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

1-1

1 Product Feature

F01S100 Product Description

1.1 Prominent Security Performance


The F01S100 cabinet features prominent security performance to comply with the international safety standards.
l

The F01S100 cabinet features prominent protection performance and anti-attack performance. The F01S100 cabinet uses the HW-2802A lock to secure the cabinet door and serve as an anti-theft measure.

1.2 Prominent Protection Performance


The F01S100 cabinet features prominent protection performance to meet the requirements of the outdoor or the indoor environment that does not have any protection.
l

When the F01S100 cabinet is configured with the MA5610/MA5616 (device that uses the forced air cooling mode for heat dissipation), the F01S100 cabinet provides the IP protection rating of the integrated device reaches IP55 ("IP" refers to International Protection. The first number "5" refers to the class for preventing the solid particle from entering the device. That is, the cabinet cannot completely prevent dust from entering the device, but the amount of dust that enters the cabinet does not damage the device. The second number "5" refers to the class for preventing water from entering the cabinet. That is, the water sprayed from different directions to the cabinet does not damage the device.). The built-in lightning arrester in the AC PDU or AC single-phase lightning protection bar protects the AC power supply. The built-in external line protection unit (optional) and the service boards provide 2-level protection for the service ports and meet the requirements of the K-45 protection index.

1.3 Easy Installation


The F01S100 cabinet can be installed on the wall, on a pole, or on a concrete pedestal. The F01S100 cabinet can be easily installed.
l

The F01S100 cabinet has firm mounting brackets on its top and thus can be hoisted in a safe and reliable way. The F01S100 cabinet provides a marking-off plate. During the installation, you can use the marking-off plate to determine the installation position of the cabinet. As a result, you need to carry the cabinet only once. The wall mounting installation parts of the F01S100 cabinet enable you to install the F01S100 cabinet on the wall that has the surface differences smaller than 10 mm. This lowers the risk of installing the cabinet.

Figure 1-1 shows the installation of the F01S100 cabinet

1-2

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

1 Product Feature

Figure 1-1 The installation of the F01S100 cabinet

1.4 Prominent Monitoring and Maintainability


The structure of the F01S100 cabinet meets the requirements of real-time monitoring and easy maintenance.
Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 1-3

1 Product Feature
l

F01S100 Product Description

The F01S100 cabinet monitors the states of the internal ambient temperature, door status, lightning arrester (optional), heat dissipation fan (optional), and major alarms of the remote power supply in real time to support the remote alarming function. The F01S100 cabinet (configured with AC-powered MA5610/MA5616) provides an AC power socket to supply power to the maintenance terminal and implement on-site maintenance.

1.5 Compact and Reliable Structure


The compact design of the F01S100 cabinet facilitates the installation of the F01S100 cabinet and ensures that the F01S100 cabinet runs reliably.
l

When the F01S100 cabinet configured with the AC-powered MA5610/MA5616, it integrates the AC-powered MA5610/MA5616, main distribution frame (MDF), optical distribution frame (ODF), AC PDU, battery (optional), battery heater (optional) and enhanced heat dissipation module (optional). The F01S100 cabinet can be installed quickly on site to meet the requirement for quick deployment. When the F01S100 cabinet configured with the DC-powered MA5610/MA5616, it integrates the DC-powered MA5610/MA5616, MDF, ODF, remote power supply, DC PDU and enhanced heat dissipation module (optional). The F01S100 cabinet can be installed quickly on site to meet the requirement for quick deployment. The ventilation design of the F01S100 cabinet can ensure that the F01S100 cabinet runs reliably in the outdoor or indoor environment when the F01S100 cabinet is not configured with any air conditioner.

1-4

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

2 Product Structure

2
About This Chapter

Product Structure

This topic describes the appearance, structure, component function, and related technical parameter of the F01S100 cabinet. 2.1 Appearance and Dimensions This topic shows the appearance and dimensions of the F01S100 cabinet. 2.2 Structure This topic describes the structure of the F01S100 cabinet when it is configured with different devices. 2.3 Power System The F01S100 cabinet uses the optional AC PDU or AC single-phase lightning protection bar to support the AC-powered MA5616/MA5610. It can also use the remote power supply to support the DC-powered MA5616/MA5610. 2.4 Cable Distribution Device The F01S100 cabinet is configured with the built-in MDF and ODF. The MDF is used to connect the internal subscriber cable and the external subscriber cable. The ODF is used to connect the optical fiber and the optical communication device. 2.5 Temperature Control Unit This topic provides the technical parameters of the built-in temperature control unit used in the F01S100 cabinet. 2.6 Monitoring System This topic describes the monitoring scheme and the built-in sensors of the F01S100 cabinet.

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

2-1

2 Product Structure

F01S100 Product Description

2.1 Appearance and Dimensions


This topic shows the appearance and dimensions of the F01S100 cabinet. Figure 2-1 shows the appearance and dimensions of the F01S100 cabinet. Figure 2-1 Appearance and dimensions of the F01S100 cabinet

2.2 Structure
This topic describes the structure of the F01S100 cabinet when it is configured with different devices.

2-2

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description


NOTE

2 Product Structure

The F01S100 cabinet provides a space of 4 U for installing devices and can be configured with the following devices:
l l

One AC-powered MA5610/MA5616. During installation, the AC-powered MA5610/MA5616 must be installed at the outermost 2 U position to facilitate heat dissipation and future maintenance. One DC-powered MA5610/MA5616 + one remote power supply + one DC PDU. During installation, the DC-powered MA5610/MA5616 must be installed at the outermost 2 U position to facilitate heat dissipation and future maintenance; the DC PDU must be installed at the inmost 1 U position.

Figure 2-2 shows the structure of the F01S100 cabinet. The advantages of the F01S100 cabinet structure are as follows:
l

The F01S100 cabinet can be installed and maintained from its front. Cables and boards can be installed or removed easily. The low-noise design is excellent. The noise is lowered to 35 dBA at nights, which is as quiet as in a library. The F01S100 cabinet provides the excellent cabling management function. The F01S100 cabinet supports up to 256 narrowband lines, which is the largest capacity for the products of the same type in the industry.

l l

Figure 2-2 Structure of the F01S100 cabinet

Configured with the AC-powered MA5610/MA5616


Table 2-1 shows the structure of the F01S100 cabinet configured with the AC-powered MA5610/MA5616.
Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 2-3

2 Product Structure

F01S100 Product Description

Table 2-1 Structure of the F01S100 cabinet (configured with the AC-powered MA5610/ MA5616) Item Service device Power system Component Name One AC-powered MA5610/MA5616
l l l

AC PDU Battery (optional) Battery Heater (optional) MDF ODF

Cable distribution device Temperature control unit Monitoring system

l l

Enhanced heat dissipation module (optional) Sensor (optional)

Configured with the DC-powered MA5610/MA5616


Table 2-2 shows the structure of the F01S100 cabinet configured with the DC-powered MA5610/MA5616. Table 2-2 Structure of the F01S100 cabinet (configured with the DC-powered MA5610/ MA5616) Item Service device Power system Cable distribution device Temperature control unit Monitoring system Component Name One DC-powered MA5610/MA5616 Remote power supply / DC PDU
l l

MDF ODF

Enhanced heat dissipation module (optional) Sensor (optional)

2.3 Power System


The F01S100 cabinet uses the optional AC PDU or AC single-phase lightning protection bar to support the AC-powered MA5616/MA5610. It can also use the remote power supply to support the DC-powered MA5616/MA5610. Figure 2-3 shows the power distribution scheme of the F01S100 cabinet
2-4 Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. Issue 01 (2009-10-28)

F01S100 Product Description

2 Product Structure

Figure 2-3 Power distribution scheme of the F01S100 cabinet

2.3.1 AC PDU This topic describes the power distribution scheme and the related technical specifications of the built-in AC PDU (optional) in the F01S100 cabinet. 2.3.2 AC Single-phase Lightning Protection Bar This topic describes the power distribution scheme and the related technical specifications of the built-in AC single-phase lightning protection bar (optional) in the F01S100 cabinet. 2.3.3 Battery
Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 2-5

2 Product Structure

F01S100 Product Description

When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616, batteries can be selected as the backup power supply. 2.3.4 Battery Heater This topic describes the technical specifications of the battery heater used in the F01S100 cabinet. 2.3.5 Remote power supply When configured with the DC-powered MA5610/MA5616, the F01S100 cabinet uses the remote power supply as its DC power input. 2.3.6 DC PDU This topic describes technical specifications of the built-in DC PDU in the F01S100 cabinet.

2.3.1 AC PDU
This topic describes the power distribution scheme and the related technical specifications of the built-in AC PDU (optional) in the F01S100 cabinet. The AC PDU consists of the lightning arrester, maintenance socket, and MCB.

Lightning Arrester
The lightning arrester protects the 220 V single-phase power system against the surge voltage caused by the lightning. Table 2-3 lists the technical specifications of the lightning arrester. Table 2-3 Specifications of the lightning arrester Item Rated voltage Maximum continuous running voltage (Uc) Rated discharge current (In) Maximum discharge current (Imax) Protection rating (Up) Value 220 VAC 380 VAC 20 kA (8/20 s) 40 kA (8/20 s)
l l

< 1.5kV (8/20 s, 5 kA) < 1.8kV (8/20 s, 15 kA)

Response time Dimensions Environment for usage

25 ns 100 mm x 65 mm x 72 mm
l l

Temperature: 40C to +70C Relative humidity: 95%

Maintenance Socket
The maintenance socket is connected to the maintenance terminal to facilitate the on-site maintenance. Table 2-4 lists the technical specifications of the maintenance socket.
2-6 Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. Issue 01 (2009-10-28)

F01S100 Product Description

2 Product Structure

Table 2-4 Technical specifications of the maintenance socket Item 220 VAC power supply Value 220 VAC/3 A

MCB
The MCB controls the external AC input.

2.3.2 AC Single-phase Lightning Protection Bar


This topic describes the power distribution scheme and the related technical specifications of the built-in AC single-phase lightning protection bar (optional) in the F01S100 cabinet. Table 2-5 lists the technical specifications of the AC single-phase lightning protection bar used in the F01S100 cabinet. Table 2-5 Technical specifications of the AC single-phase lightning protection bar Item Rated working voltage Maximum continuous running voltage (Uc) Working frequency Rated working current Fuse current Fuse type Protection mode Rated through-current capacity (In) Maximum discharge current (Imax) Voltage protection rating (Up) LED for improper grounding Value 250 VAC 385 VAC 47 Hz to 63 Hz 8A 8A Slow-blow L-N, L-PE, and N-PE 5 kA (8/20 s) 15 kA (8/20 s) 1500 V (8/20 us) Off: normal Red and on: An alarm is generated. LED for polarity reversal Off: normal Yellow and on: An alarm is generated. LED for lightning protection Off: normal Red and on: The lightning protection fails. Type of socket hole Number of socket holes
Issue 01 (2009-10-28)

Versatile 3 bits
2-7

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

2 Product Structure

F01S100 Product Description

Item Shell protection rating Flame retardant rating Response time Cable specifications Working temperature Storage temperature Relative humidity Dimensions (W x D x H)

Value IP20 94-V0 Ta 25 ns With a diameter of 8 mm and a length of 2 m 40C to +70C 40C to +85C 5% to 95% 288 mm x 58 mm x 46 mm

2.3.3 Battery
When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616, batteries can be selected as the backup power supply. The AC-powered MA5610/MA5616 provides the interface for batteries.
NOTE

When the F01S100 cabinet is configured with the AC-powered MA5610/MA5616, a set (four batteries) of 12 Ah batteries can be selected as the backup power supply.

Figure 2-4 shows appearance of battery. Figure 2-4 Appearance of battery

Table 2-6 lists the technical specifications of the batteries used in the F01S100 cabinet. Table 2-6 Technical specifications of battery Item Rate working voltage (when configured with four batteries)
2-8

Value 48 VDC

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

2 Product Structure

Item Rated capacity Floating charging voltage of the battery set Maximum charging current Voltage of a single battery Working temperature range Dimensions of a single battery (W x D x H) Weight of a single battery

Value 12 Ah 54 VDC 3.6 A 12 VDC 15C to +50C 151 mm x 100 mm x 98 mm 3.83 kg

2.3.4 Battery Heater


This topic describes the technical specifications of the battery heater used in the F01S100 cabinet.
NOTE

Two battery heaters must be configured when the F01S100 cabinet is used in the area where the ambient temperature is below 0C.

Table 2-7 lists the technical specifications of the battery heater used in the F01S100 cabinet. Table 2-7 Technical specifications of the battery heater Item Rated voltage Voltage range Rated heating power Insulation resistance Value 220 VAC 150 VAC to 300 VAC 70 W The insulation resistance between the heater leading power cable and the heater shell must be greater than 10 megohms. The heater can work reliably in the environment with relative humidity of 5% to 95%. 180 mm x 125 mm x 2 mm

Working environment

Dimensions (L x W x D)

2.3.5 Remote power supply


When configured with the DC-powered MA5610/MA5616, the F01S100 cabinet uses the remote power supply as its DC power input. Table 2-8 lists the technical specifications of the remote power supply used in the F01S100 cabinet.
Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 2-9

2 Product Structure

F01S100 Product Description

Table 2-8 Technical specifications of the remote power supply Item Input rated voltage Input voltage range Output rated voltage Output voltage range Cooling method Working temperature range Storage temperature range Weight Dimensions (W x D x H) Value 340 VDC (+/-170 VDC) 285 VDC to 348 VDC 48 VDC 40 VDC to 57 VDC Forced air cooling -40 to +70 -40 to +80 2.5 kg 445 mm x 230 mm x 44.5 mm

2.3.6 DC PDU
This topic describes technical specifications of the built-in DC PDU in the F01S100 cabinet. The DC PDU consists of the MCB. The MCB controls the -48 VDC output of the remote power supply.

2.4 Cable Distribution Device


The F01S100 cabinet is configured with the built-in MDF and ODF. The MDF is used to connect the internal subscriber cable and the external subscriber cable. The ODF is used to connect the optical fiber and the optical communication device. 2.4.1 MDF This topic describes the specifications of the built-in MDF in the F01S100 cabinet. 2.4.2 ODF This topic provides the appearance of the built-in ODF in the F01S100 cabinet and describes the capacity specifications of the ODF.

2.4.1 MDF
This topic describes the specifications of the built-in MDF in the F01S100 cabinet.
l

The 16-pair exchange side terminal blocks are installed to be connected with the internal cables of the MDF and the jumper cables. The exchange side terminal blocks are also used for tests and open circuits. The 10-pair cable side terminal blocks are installed to be connected with the external cables of the MDF and the jumper cables. The protective unit (optional) installed in the cable side terminal block provides the overvoltage protection and generates alarms.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. Issue 01 (2009-10-28)

2-10

F01S100 Product Description


l

2 Product Structure

The harness, which consists of the connector, subscriber cable, and terminal block, provides connections between the service boards and the MDF.

Figure 2-5 shows the appearance of the MDF in the F01S100 cabinet. Figure 2-5 Appearance of the MDF in the F01S100 cabinet

Table 2-9 lists the specifications of the MDF. Table 2-9 Specifications of the MDF in the F01S100 cabinet Item Type of the exchange side terminal block Value JPX658-STO-236XD (White)

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

2-11

2 Product Structure

F01S100 Product Description

Item Height of the exchange side terminal block Type of the cable side terminal block

Value 12 mm

l l l l

JPX658-FA8-239XB (White) JPX658-FA8-239XH (Yellow) JPX658-BLK2-E10VB (White) JPX658-BLK2-E10VH (Yellow) JPX658-FA8-239XB (15 mm) JPX658-FA8-239XH (15 mm) JPX658-BLK2-E10VB (13 mm) JPX658-BLK2-E10VH (13 mm) JPX658-FA9-280J JPX658-FA10-97 JPX658-SPD2-G400T JPX658-VPS3-Y600-VDSL2 JPX658-VPS3-E270A-VDSL2 JPX658-VPS3-E270B-VDSL2 JPX658-VPS3-E320-VDSL2

Height of the cable side terminal block

l l l l

Type of the protective unit

l l l

Type of the SPL

l l l l

Height of the MDF

680 mm, which can be adjusted flexibly.

2.4.2 ODF
This topic provides the appearance of the built-in ODF in the F01S100 cabinet and describes the capacity specifications of the ODF. The ODF is used to connect the optical fiber and the optical communication device. The ODF can perform the following functions:
l l l l l

Fasten and protect optical fibers. Protect the cores of the peeled optical fibers. Distribute optical fibers. Adjust optical fibers. Store optical fibers.

Figure 2-6 shows the appearance of the ODF in the F01S100 cabinet.

2-12

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

2 Product Structure

Figure 2-6 Appearance of the ODF in the F01S100 cabinet

Table 2-10 lists the specifications of the built-in ODF in the F01S100 cabinet. Table 2-10 Specifications of the ODF ODF Type ODF (simple) Port Type FC/PC Capacity 6 adapters (default configuration: 2 adapters)

2.5 Temperature Control Unit


This topic provides the technical parameters of the built-in temperature control unit used in the F01S100 cabinet. The F01S100 cabinet uses the heat exchanger mounted on the cabinet wall for heat dissipation. Besides, the cabinet can also be configured with a enhanced heat dissipation module to further improve the heat dissipation performance and to meet the requirement of the environment with a temperature higher than 45C (When the solar radiation intensity is 1120 W/m2, the highest environment temperature is 50C). The enhanced heat dissipation consists of two heat dissipation fans. Table 2-11 describes the technical parameters of the heat dissipation fan.

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

2-13

2 Product Structure

F01S100 Product Description

Table 2-11 Technical parameters of the heat dissipation fan Item Rated voltage Running voltage Input current Running power Rotating speed Wind volume Dimensions Value -48 VDC 28 VDC to 54 VDC 0.17 A 8.16 W 3700 rpm 81.97 CFM 92 mm x 92 mm x 25.4 mm

2.6 Monitoring System


This topic describes the monitoring scheme and the built-in sensors of the F01S100 cabinet. 2.6.1 Monitoring Scheme The service chassis installed in the F01S100 cabinet monitors the environment and key components of the cabinet. 2.6.2 Sensor This topic provides the appearances of the built-in sensors in the F01S100 cabinet and provides the information about the functions of the sensors.

2.6.1 Monitoring Scheme


The service chassis installed in the F01S100 cabinet monitors the environment and key components of the cabinet. Figure 2-7 shows the monitoring scheme of the F01S100 cabinet. Figure 2-7 Monitoring scheme of the F01S100 cabinet

2-14

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

2 Product Structure

2.6.2 Sensor
This topic provides the appearances of the built-in sensors in the F01S100 cabinet and provides the information about the functions of the sensors.

Door status sensor


The door status sensor uses the door status switch as the probe. The door status switch consists of two built-in parts. The spring clips of the door status switch attract each other due to electromagnetic interaction. The door status switch monitors the status of the cabinet door, and outputs the dry contact output signals that do not have polarity. Figure 2-8 shows the appearance of the door status sensor. Figure 2-8 Appearance of the door status sensor

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

2-15

F01S100 Product Description

3 System Configuration

3
About This Chapter

System Configuration

This topic provides the number of subscribers supported by the F01S100 cabinet. 3.1 F01S100 cabinet Configured with the MA5610 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5610. 3.2 F01S100 cabinet Configured with the MA5616 This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5616.

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

3-1

3 System Configuration

F01S100 Product Description

3.1 F01S100 cabinet Configured with the MA5610


This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5610. Table 3-1 lists the number of subscribers supported by the F01S100 cabinet in different configurations. Table 3-1 Number of subscribers supported by the F01S100 cabinet in different configurations Configuration One MA5610 (configured with four ASPB boards) One MA5610 (configured with three EIUA boards + one ASPB board) One MA5610 (configured with two EIUA boards + two ASPB boards) One MA5610 (configured with one EIUA board + three ASPB boards) Maximum Number of Subscribers 256 POTS 48 LAN + 64 POTS 32 LAN + 128 POTS 16 LAN + 192 POTS

NOTE

l l

The ASPB board is the 64-channel narrowband service board that provides the POTS service. The EIUA board is the 16-channel Ethernet access board that provides the LAN service.

In Table 3-1, the number of subscribers is counted when the cabinet is configured with the device provided by Huawei. For details of the device, see the MA5610 Hardware Description.

3.2 F01S100 cabinet Configured with the MA5616


This topic provides the number of subscribers supported by the F01S100 cabinet when it is configured with the MA5616. Table 3-2 lists the number of subscribers supported by the F01S100 cabinet in different configurations. Table 3-2 Number of subscribers supported by the F01S100 cabinet in different configurations Configuration One MA5616 (configured with four ASPB boards) One MA5616 (configured with four ADLE boards) One MA5616 (configured with one ASPB board + three ADLE boards)
3-2

Maximum Number of Subscribers 256 POTS 128 ADSL2+ 64 POTS + 96 ADSL2+

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

3 System Configuration

Configuration One MA5616 (configured with four VDSE/VDSH/ VDTH boards) One MA5616 (configured with two ASPB boards + two VDSE/VDSH boards)

Maximum Number of Subscribers 96 VDSL2 128 POTS + 48 VDSL2

NOTE

l l l l l l

The ASPB board is the 64-channel narrowband service board that provides the POTS service. The ADLE board is the 32-channel ADSL2+ service board with a built-in splitter. It provides the ADSL2+ services. The VDSE board is the 24-channel VDSL2 service board with a built-in splitter. It provides the VDSL2 service. The VDSH board is the 24-channel VDSL2 service board without a built-in splitter. It provides the VDSL2 service. The VDTH board is the 24-channel VDSL2 service board without a built-in splitter. It provides the VDSL2 service. The VDGE board is the 16-channel VDSL2 service board with a built-in splitter. It provides the VDSL2 service.

In Table 3-2, the number of subscribers is counted when the cabinet is configured with the device provided by Huawei. For details of the device, see the MA5616 Hardware Description.

Issue 01 (2009-10-28)

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

3-3

F01S100 Product Description

4 System Parameters

4
Table 4-1 Dimensions of the F01S100 cabinet Item F01S100 cabinet (with battery compartment)

System Parameters

This topic provides the parameters of the F01S100 cabinet. Table 4-1 lists the dimensions of the F01S100 cabinet.

Dimensions (W x D x H) 720 mm x 250 mm x 830 mm 720 mm x 250 mm x 1030 mm

F01S100 cabinet (without battery compartment)

Table 4-2 lists the weight of the F01S100 cabinet. Table 4-2 Weight of the F01S100 cabinet Item F01S100 cabinet (without battery compartment, fullyloaded) F01S100 cabinet (fully-loaded, with battery compartment, fully-loaded) Weight 57 kg 84 kg

Table 4-3 lists the power of the F01S100 cabinet. Table 4-3 Power of the F01S100 cabinet Item Maximum power of the F01S100 cabinet (configured with the AC-powered MA5610/MA5616) Maximum power of the F01S100 cabinet (configured with the DC-powered MA5610/MA5616)
Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Value 187.6 W 250 W

4-1

F01S100 Product Description

5 Environmental Specifications

5
Environment Storage

Environmental Specifications

This topic describes the environmental specifications for the storage, transportation, and running of the cabinet. Table 5-1 lists the environment specifications for the storage, transportation, and running of the F01S100 cabinet. Table 5-1 Environment specifications of the F01S100 cabinet Item Solar radiation intensity Temperature Relative humidity Air pressure Transportation Solar radiation intensity Temperature Relative humidity (without much variation in temperature) Relative humidity (with much variation in temperature: air/air) Air pressure Running Solar radiation intensity Temperature (when the F01S100 cabinet is configured with one MA5610/MA5616, without the enhanced heat dissipation module and ) Temperature (when the F01S100 cabinet is configured with one MA5610/MA5616, with the enhanced heat dissipation module and )
Issue 01 (2009-10-28) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Value 1120 W/m2 45C to +45C 8% to 100% 70 kPa to 106 kPa 1120 W/m2 40C to +70C 95% (+45C) 95% (-40C to +30C) 70 kPa 1120 W/m2 33C to +45C

33C to +50C

5-1

5 Environmental Specifications

F01S100 Product Description

Environment

Item Relative humidity Air pressure

Value 8% to 100% 70 kPa to 106 kPa

5-2

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

6 Standards Compliance

6
Item Running environment

Standards Compliance

This topic provides the standards that the F01S100 cabinet complies with in terms of the environment, structure, power system and lightning proof. Table 6-1 provides the standards compliance of the F01S100 cabinet. Table 6-1 Standards compliance of the F01S100 cabinet Standards Compliance ETSI EN 300 019-1-4: Environmental conditions and environmental test for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at nonweather protected locations ETSI 300 019 1 - 2: Environmental conditions and environmental test for telecommunications equipment; Part 1-2: Classification of environmental conditions; Transportation ETSI EN 300 01911 IEC 609501/ IEC 60065: Safety of information of technology equipment IEC 60950-22: Degrees of protection provided by enclosures (IP code) ETSI EN 300 753 1997-10
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Class Class 4.1E Nonweatherprotected locationsextended

Transportation environment

Class 2.2 Public transportation

Storage environment Safety

Class 1.3E Necessary

Protection

IP55

Noise
Issue 01 (2009-10-28)

Class 4.1 Rural


6-1

6 Standards Compliance

F01S100 Product Description

Structure MDF

IEC 297_1 (2,3): Cabinets and Pitches of racks structure K.45: Resistibility of telecommunication equipment installed in the access and trunk networks to overvoltage and overcurrent YD 694-2004

Necessary

Lightning proof

ITU-T K.45: Performance requirement for surge protective device connected to low-voltage distribution systems of telecommunication stations/ sites ETSI EN 300 253: Earthing and bonding of telecommunication equipment in telecommunication centers

Grounding

Necessary

6-2

Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd.

Issue 01 (2009-10-28)

F01S100 Product Description

7 Acronyms and Abbreviations

7
A AC ADSL ADSL2+ D DC

Acronyms and Abbreviations

Alternating current Asymmetrical digital subscriber line Asymmetrical digital subscriber line 2 plus

Direct current

E EMC EMU EN ETS ETSI Electro magnetic compatibility Environment monitoring unit End node European Telecommunication Standard European Telecommunications Standards Institute

F FE Fast Ethernet

G GE Gigabit Ethernet

I IDC
Issue 01 (2009-10-28)

Internet data center


Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 7-1

7 Acronyms and Abbreviations

F01S100 Product Description

IEC IEEE IP ITU-T

International Electrotechnical Commission Institute of Electrical and Electronics Engineers Internet protocol International Telecommunication Union - Telecommunication Standardization Sector

L LAN Local area network

M MDF Main distribution frame

O ODF Optical distribution frame

P POTS PSTN Plain old telephone service Public switched telephone network

V VDSL VDSL2 Very high speed digital subscriber line Very high speed digital subscriber line 2