Sunteți pe pagina 1din 130

TEMS INVESTIGATION 14.

1 GETTING STARTED MANUAL

This manual is provided by Ascom Network Testing AB without any kind of warranty. Improvements and changes in this description due to typographical errors or inaccuracies in current information, or improvements to programs and/or equipment may be made by Ascom Network Testing AB at any time without notice. These changes will, however, be incorporated into new editions of this manual. No part of this publication may be reproduced, transmitted, stored in a retrieval system, nor translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of the copyrighted owner, Ascom Network Testing AB. TEMS is a trademark of Ascom. All other trademarks are the property of their respective holders. Ascom 2012. All rights reserved. Document number: NT12-6999 ver 1.0

Contents

Contents

1. Introduction

1.1. What Is the Getting Started Manual? . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2. Whats in This Manual (and Whats Not) . . . . . . . . . . . . . . . . . . . . . . 1 1.3. Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. Read This Before You Start Drive Testing 3. Product Packaging

5 6

3.1. Base Software Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.2. Replay Packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.3. Further Licensing Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.3.1. Licensing for External Devices . . . . . . . . . . . . . . . . . . . . . . . . 7 3.3.2. Licensing for AQM (PESQ/POLQA) . . . . . . . . . . . . . . . . . . . . 8 3.3.2.1. Notes on AQM Module Based Solutions . . . . . . . . . . . 9 3.3.3. Licensing for VoIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 3.3.4. Network (Floating) Licenses. . . . . . . . . . . . . . . . . . . . . . . . . . 9 3.4. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

4. Licensing

11

4.1. Licensing Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.2. Local vs. Network Licenses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4.3. License Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.4. Drivers for HASP Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4.5. Inspecting the Scope of Your License. . . . . . . . . . . . . . . . . . . . . . . 13

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

5. Installing TEMS Investigation

16
16 16 17 18 18 18 18 19 19 19 19 20 21 22

5.1. PC Hardware and Software Requirements. . . . . . . . . . . . . . . . . . . 5.1.1. Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.2. Operating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.1.3. Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2. Other Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.1. HASP License Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.2. Audio Quality Measurements . . . . . . . . . . . . . . . . . . . . . . . . 5.2.3. VoIP Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.4. Video Streaming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2.5. UDP Testing with TEMS UDP Server . . . . . . . . . . . . . . . . . 5.2.6. Network Bandwidth (UDP/TCP) Testing with Iperf . . . . . . . 5.3. Installing TEMS Investigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.4. Automatic Check for TEMS Investigation Software Updates . . . . . 5.5. Uninstalling TEMS Investigation . . . . . . . . . . . . . . . . . . . . . . . . . . .

6. Installing and Using HASP Software Protection

23
23 23 23 24 24 24 25 28 32 34 34 34 36 37 37 38

6.1. Hardware-based Licensing: HASP HL . . . . . . . . . . . . . . . . . . . . . . 6.2. Software-based Licensing: HASP SL . . . . . . . . . . . . . . . . . . . . . . . 6.2.1. HASP SL Local License Installation. . . . . . . . . . . . . . . . . . . 6.2.2. Using HASP SL Network Licenses . . . . . . . . . . . . . . . . . . . 6.2.2.1. TCP Port Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2.2.2. HASP SL License Server Installation . . . . . . . . . . . . 6.2.2.3. HASP SL Network License: Online Detach/Attach . . 6.2.2.4. HASP SL Network License: Offline Detach/Attach . . 6.2.2.5. Handling HASP SL Network Licenses for TEMS Products: Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2.2.6. Monitoring HASP SL License Usage . . . . . . . . . . . . 6.3. Updating HASP Keys (HL/SL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3.1. Updating HASP HL Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3.2. Updating HASP SL Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4. Sentinel HASP Runtime Network Activity . . . . . . . . . . . . . . . . . . . . 6.4.1. Local Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4.2. Remote Communications. . . . . . . . . . . . . . . . . . . . . . . . . . .

7. Installation of Device Drivers

40

7.1. Installation of USB Drivers for User Terminals . . . . . . . . . . . . . . . . 40 7.1.1. Sony Ericsson Phones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

ii

Contents

7.1.2. Datang Phones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 7.1.3. Hisilicon Chipset Based Devices . . . . . . . . . . . . . . . . . . . . . 42 7.1.4. Nokia Phones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.1.5. Qualcomm Chipset Based Devices . . . . . . . . . . . . . . . . . . . 43 7.1.6. Samsung Galaxy S 4G, Samsung Infuse 4G . . . . . . . . . . . . 43 7.2. Installation of Driver for SRU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.2.1. Installing Drivers from Driver Installation CD . . . . . . . . . . . . 43 7.2.1.1. Extra Steps for Windows 7 . . . . . . . . . . . . . . . . . . . . 45 7.2.2. Installing Drivers from Internal SSD Drive . . . . . . . . . . . . . . 47 7.2.2.1. Installing Drivers in Windows 7 . . . . . . . . . . . . . . . . . 47 7.2.2.2. Installing Drivers in Windows XP. . . . . . . . . . . . . . . . 48 7.3. Installation of USB Driver for Anritsu Scanners. . . . . . . . . . . . . . . . 50 7.3.1. Anritsu ML8780A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 7.4. Installation of USB Driver for PCTel Scanners . . . . . . . . . . . . . . . . 51 7.4.1. PCTel SeeGull LX MM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 7.4.2. PCTel SeeGull EX/MX, PCTel PCT . . . . . . . . . . . . . . . . . . . 51 7.5. Installation of USB Driver for GPS Units . . . . . . . . . . . . . . . . . . . . . 51 7.6. Installation of Driver for USB-to-RS232 Serial Converter in Equipment Cases/Backpack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 7.7. Installation of Drivers for AQM Modules . . . . . . . . . . . . . . . . . . . . . 52 7.7.1. General Advice on Driver Installation for AQM Equipment Case/Backpack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 7.8. Installation of Drivers for Audio Capturing Unit (TerraTec) . . . . . . . 53

8. TEMS Investigation Computer Diagnostics

54

8.1. Running TEMS Investigation Computer Diagnostics . . . . . . . . . . . 54 8.1.1. Setting Up Test Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 8.1.2. Diagnostics Presentation in User Interface . . . . . . . . . . . . . 55 8.1.2.1. Windows Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 8.1.2.2. Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 8.1.2.3. Further Columns in the Computer Diagnostics Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 8.1.3. Diagnostics Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 8.1.4. Iterating the Diagnostics Procedure . . . . . . . . . . . . . . . . . . . 57 8.2. Suitable PC Settings for TEMS Investigation . . . . . . . . . . . . . . . . . 57 8.2.1. Administrator Rights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 8.2.2. Automatic Updating of Software. . . . . . . . . . . . . . . . . . . . . . 58 8.2.3. AutoPlay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 8.2.4. Intel SpeedStep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 8.2.5. IR Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

NT12-6999 ver 1.0

iii

TEMS Investigation 14.1 Getting Started Manual

8.2.6. My Documents Folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.7. Port-scanning Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.8. RTP (UDP) Ports for Video Streaming. . . . . . . . . . . . . . . . . 8.2.9. Security Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.10. Sleep Mode, Screen Savers, Energy Saving Features . . . 8.2.11. USB Legacy Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.12. Windows Firewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.13. Windows Media Player . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.14. Windows 7 Specific Settings . . . . . . . . . . . . . . . . . . . . . . . 8.2.14.1. IPv6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.14.2. Power Management . . . . . . . . . . . . . . . . . . . . . . . . 8.2.14.3. User Access Control (UAC) . . . . . . . . . . . . . . . . . . 8.2.14.4. Visual Effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.15. Windows Vista Specific Settings . . . . . . . . . . . . . . . . . . . . 8.2.15.1. IPv6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.15.2. Power Management . . . . . . . . . . . . . . . . . . . . . . . . 8.2.15.3. User Access Control (UAC) . . . . . . . . . . . . . . . . . . 8.2.15.4. Visual Effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.16. Windows XP Specific Settings . . . . . . . . . . . . . . . . . . . . . . 8.2.16.1. Power Management . . . . . . . . . . . . . . . . . . . . . . . . 8.2.16.2. Visual Effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.2.16.3. Windows Media Player . . . . . . . . . . . . . . . . . . . . . .

59 59 59 59 59 60 60 60 60 60 61 61 61 62 62 62 62 63 63 63 63 63

9. Installing the Call Generator 10. External Equipment

64 65
65 65 65 67 67 67 68 68 68 68 69 69 69 69

10.1. Connectable Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.1. User Terminals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.1.1. UMTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.1.2. LTE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.1.3. TD-SCDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.1.4. CDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.2. Fixed Wireless Terminals. . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.3. AQM Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.4. Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.4.1. GSM, WCDMA, LTE . . . . . . . . . . . . . . . . . . . . . . . . 10.1.4.2. TD-SCDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.4.3. CDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.4.4. WiMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.1.5. GPS Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

iv

Contents

10.2. Capabilities of User Terminals Sold with TEMS Investigation. . . . 70 10.3. Supported AQM Capable Devices . . . . . . . . . . . . . . . . . . . . . . . . 72 10.3.1. AQM with Call Generator/MRU . . . . . . . . . . . . . . . . . . . . . 72 10.3.1.1. UMTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 10.3.1.2. CDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 10.3.2. AQM with ACU (TerraTec) . . . . . . . . . . . . . . . . . . . . . . . . . 72 10.3.2.1. UMTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 10.3.2.2. CDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 10.4. Basic Configuration of User Terminals . . . . . . . . . . . . . . . . . . . . . 73 10.5. Connecting External Antennas to Phones. . . . . . . . . . . . . . . . . . . 75 10.6. Configuring Devices for Data Services . . . . . . . . . . . . . . . . . . . . . 76 10.6.1. Setting Up the Device APN (UMTS). . . . . . . . . . . . . . . . . . 76 10.7. Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.7.1. Anritsu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.7.2. PCTel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.7.2.1. PCTel SeeGull LX . . . . . . . . . . . . . . . . . . . . . . . . . . 77 10.7.2.2. PCTel SeeGull EX. . . . . . . . . . . . . . . . . . . . . . . . . . 78 10.7.2.3. PCTel SeeGull MX . . . . . . . . . . . . . . . . . . . . . . . . . 78 10.7.2.4. PCTel PCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 10.7.2.5. Technical Notes on PCTel Scanners . . . . . . . . . . . 78 10.7.3. Andrew i.Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 10.7.4. Rohde & Schwarz TSMW. . . . . . . . . . . . . . . . . . . . . . . . . . 80 10.7.5. DRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

11. PC and Device Configuration for Ericsson Fixed Wireless Terminal

81

11.1. PC Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 11.2. FWT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

12. PC and Device Configuration for DRT Scanner 83


12.1. Direct Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 12.2. Local Area Network Connection . . . . . . . . . . . . . . . . . . . . . . . . . . 84 12.3. Verifying the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 12.4. Scanner Antenna Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

13. PC and Device Configuration for Andrew i.Scan 86


13.1. Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

13.2. Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.2.1. Setting Up the Serial Connection. . . . . . . . . . . . . . . . . . . . 13.2.2. Configuring the Andrew Scanner . . . . . . . . . . . . . . . . . . . . 13.2.3. Manual Input of IP Address If Autodetect Fails . . . . . . . . . 13.2.4. Configuring the PC Network Adapter (for Direct ScannerPC Connection) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.2.5. Connecting the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . .

86 86 87 88 89 90

14. PC and Device Configuration for R&S TSMW Scanner 15. PC and Device Configuration for DRT Transmitter

91

93
93 95 95 96 97 97 97 99

15.1. Setting Up the Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.1.1. Changing between Ethernet and Wi-Fi Network Configuration Modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.2. Configuring the PC for Direct Connection. . . . . . . . . . . . . . . . . . . 15.3. Configuring the PC for LAN Connection . . . . . . . . . . . . . . . . . . . . 15.4. Verifying the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.5. Configuring Transmitter Cell Information . . . . . . . . . . . . . . . . . . . 15.5.1. Configuring the Transmitter Using Nome. . . . . . . . . . . . . . 15.5.2. Configuring the Transmitter Using Web Interface . . . . . . .

16. Preparations for AQM with Audio Capturing Unit (ACU)

101
101 101 102 103 105 106 107

16.1. Installing Drivers for ACU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.2. Adjusting ACU Physical Controls . . . . . . . . . . . . . . . . . . . . . . . . 16.3. Connecting Equipment to the ACU . . . . . . . . . . . . . . . . . . . . . . . 16.4. Settings in the TerraTec PC User Interface . . . . . . . . . . . . . . . . 16.5. Configuration of Windows Settings . . . . . . . . . . . . . . . . . . . . . . . 16.6. Calibration of Phones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16.7. Speech Samples for Audio Quality Measurement . . . . . . . . . . .

17. Connecting and Activating External Equipment

108

vi

Contents

18. Cell Data and Maps Index

109 111

NT12-6999 ver 1.0

vii

TEMS Investigation 14.1 Getting Started Manual

viii

Chapter 1. Introduction

1.

Introduction

Thank you for choosing TEMS Investigation the industry-leading tool for troubleshooting, verification, optimization, and maintenance of wireless networks. Offering data collection, real-time analysis, and post-processing all in one, TEMS Investigation is a complete solution for all of a network operators daily network optimization tasks. This complete solution eliminates the need for multiple tools, reducing costs and saving time and effort for operations staff.

1.1.

What Is the Getting Started Manual?

The Getting Started Manual deals with preliminaries that you must work through before you can start using TEMS Investigation, such as configuring your computer and external devices. The manual also covers the installation of TEMS Investigation itself. Most of the procedures described here only have to be performed once, or when you are exchanging pieces of hardware. The other manuals delivered with the product (Users Manual, Information Elements and Events, Technical Reference) concentrate on how to operate the TEMS Investigation software once you have it installed and all your hardware is ready for use. These manuals are what you will probably be referring to most of the time once you have gotten started.

1.2.

Whats in This Manual (and Whats Not)

Main Topics Contents of TEMS Investigation product packages: chapter 3 Licensing: chapter 4 PC hardware and software requirements: section 5.1 Installing the TEMS Investigation software: section 5.3 Installing and using HASP software protection: chapter 6

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

Installing device drivers: chapter 7 Running the Computer Diagnostics utility: section 8.1 Configuring the PC for TEMS Investigation: section 8.2 Installing the Call Generator: chapter 9 Connectable external devices: chapter 10 Configuring the PC for use with various devices: chapters 1115 Preparations for audio quality measurement with ACU: chapter 16

Cell Data and Maps The following tasks may also be regarded as preliminary ones: Importing network cell data Importing map files

These procedures, however, are not covered here but in the Users Manual, since they are handled from within the TEMS Investigation software application. Chapter 18 gives the appropriate references. Equipment Cases The TEMS equipment cases, designed to accommodate phones and other equipment during drive tests, are not covered here but have their own manuals. These, however, sometimes refer to TEMS Investigation documentation. Installation of drivers for TEMS equipment cases is explained in section 7.6. TEMS Pocket Certain phones that are connectable in TEMS Investigation have TEMS Pocket functionality. For these phones, a separate Users Manual deals with the TEMS Pocket functions. However, when the phone is activated in TEMS Investigation, the Pocket functions are disabled. Nonetheless, it is possible to purchase such phones with fully enabled TEMS Pocket software; see section 3.4. Release Note Some technical issues not addressed in this manual are dealt with in the file ReleaseNote.pdf which is found in the TEMS Investigation installation folder.

Chapter 1. Introduction

FAQ Many questions regarding TEMS Investigation are answered in the FAQ sections found on the Web at www.ascom.com/en/index/support/supporttems/technical-support/tems-investigation.htm. Technical Support If you have a question about TEMS Investigation which is not answered in any of the manuals nor in any of the other sources mentioned above, please contact technical support. Contact information is given on the Web at www.ascom.com/networktesting under the link TEMS Support. TEMS Bulletins TEMS Bulletins contain updates on new TEMS product releases, events, and general information about the TEMS portfolio. You can also obtain up-to-date details on patch releases. To sign up for this free service, go to www.ascom.com/networktesting and, under the heading TEMS Bulletins, click the link Register for TEMS Bulletins. Along with this material you will also receive our customer magazine, TEMS News.

1.3.

Definitions

This section explains a number of central concepts in TEMS Investigation which are frequently referred to in this manual. Phone The term phone covers user terminals from all supported technologies. When a subset is meant, a suitable qualifier is prefixed, and/or a more precise term is used (GSM phone, Sony Ericsson GSM phone, LG UE, Samsung LTE modem, Sierra Wireless CDMA data card, etc.). Some user terminals supported by TEMS Investigation are in fact data cards, USB modems, etc. rather than phones. The word terminal is therefore sometimes used instead of phone, without any difference in meaning from the point of view of TEMS Investigation. Scanner The term scanner denotes a device dedicated to scanning, for example a PCTel scanner. Phones with scanning capabilities are not referred to as scanners.

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

Data Services This term refers to services requiring a data connection (either circuitswitched or packet-switched), as opposed to voice calls.

Chapter 2. Read This Before You Start Drive Testing

2.

Read This Before You Start Drive Testing

This chapter sums up some especially important prerequisites and necessary preparations for drive testing with TEMS Investigation. Make sure that all external devices have adequate power supply. Further information: See section 5.1.1, Note.

Make sure that appropriate drivers are installed for all external devices. Further information: See chapter 7.

When doing data collection in LTE networks or in other scenarios that entail a high CPU load, it is critically important for performance reasons to disable non-vital PC functions that consume a lot of processing power, especially visual effects. Further information: See section 8.2 and particularly sections 8.2.14.4, 8.2.15.4, 8.2.16.2 regarding visual effects.

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

3.

Product Packaging

TEMS Investigation 14.1 is offered in the following types of package: Base Software Packages Replay Packages

For Base Software Packages, support for an arbitrary subset of the supported cellular technologies can be purchased. The only dependency is that WCDMA always comes with GSM support included. For packages that include GSM but not WCDMA, the following holds: Any GSM data collected with equipment that is supported by the product can be analyzed. This means that TEMS Investigation logfiles recorded with WCDMA-capable devices can be loaded in the application, and any GSM data contained in such files can be studied. Replay Packages always have support for all technologies.

3.1.

Base Software Packages

The following contents are part of all Base Software Packages: TEMS Investigation 14.1 CD with TEMS Investigation PC software, including user documentation in electronic format (*.chm, *.pdf) CD with PC device drivers TEMS Investigation license, perpetual

Other USB hub, 4-port USB hardware key (HASP HL) or electronic software key (HASP SL) holding the TEMS Investigation license

Chapter 3. Product Packaging

Base Software Packages encompass all TEMS Investigation functionality, including data collection and realtime presentation. However, they do not in themselves include any licenses for connecting particular external devices; all of these devices require a separate license option as detailed in section 3.3.1. Further license options are offered for collecting data with multiple phones concurrently as well as for AQM; again, see section 3.3.1. Within the technologies selected in the package, the Base Software Package license permits loading of logfiles recorded with any equipment that is supported by the product, as well as logfiles from a number of other sources; see the Users Manual, section 11.3. No device-specific license options are ever required for this.

3.2.

Replay Packages

These packages give access only to a small part of the TEMS Investigation functionality: a Replay Package license allows loading of TEMS Investigation logfiles. It is not possible to do data collection or present data in real time, nor is it possible to load logfiles from sources other than TEMS Investigation. These contents are included in all Replay Packages: CD with TEMS Investigation PC software, including user documentation in electronic format (*.chm, *.pdf) USB hardware key (HASP HL) or electronic software key (HASP SL) holding the TEMS Investigation license

3.3.

Further Licensing Options

See chapter 4 about how the licensing applies in practice.

3.3.1.

Licensing for External Devices

A separate license option is required for connecting each of the following categories of equipment in TEMS Investigation: Sony Ericsson phones and SRUs (Scanning Receiver Units) Nokia phones Devices based on Altair TD-LTE-capable chipsets Devices based on GCT LTE-capable chipsets Devices based on Hisilicon LTE-capable chipsets

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

Devices based on Qualcomm HSDPA-capable chipsets (not supporting HSUPA) Devices based on Qualcomm HSPA+ and HSPA-capable chipsets (i.e. supporting at least HSDPA and HSUPA, and possibly HSPA+ as well) Devices based on Qualcomm LTE-capable chipsets Devices based on Qualcomm TD-LTE-capable chipsets Devices based on Qualcomm CDMA-capable chipsets (up to EV-DO Rev. A) Devices based on Qualcomm EV-DO Rev. B capable chipsets Devices based on Sequans TD-LTE-capable chipsets Devices based on ST-Ericsson chipsets Devices based on Via chipsets (CDMA/EV-DO) Datang phones (TD-SCDMA) LG USB modems (LTE) Samsung USB modems (LTE) PCTel scanners DRT scanners Anritsu scanners Andrew scanners Rohde & Schwarz scanners Transcom scanners

For user terminals, the set of license options purchased grants permission to collect data with one device at a time, belonging to one of the selected equipment categories. Further license options are offered for data collection with multiple user terminals concurrently. No restriction on the number of connectable devices applies to scanners (or to GPS units, for which no special license is required).

3.3.2.

Licensing for AQM (PESQ/POLQA)

A separate license option is offered for calculating PESQ/POLQA and making other audio quality measurements. The same license option covers all of the

Chapter 3. Product Packaging

following AQM solutions (see the Users Manual, chapter 35 and section 20.16.7.4): Mobile-to-fixed AQM with AQM module and Call Generator Service Control option M2F DL + UL Mobile-to-mobile AQM with AQM module and MRU Service Control option M2M DL Mobile-to-mobile AQM with ACU Service Control option M2M DL + UL.

AQM for VoIP is licensed as part of VoIP testing; see section 3.3.3.

3.3.2.1.

Notes on AQM Module Based Solutions

Downlink AQM modules are either stand-alone or installed in an equipment case. In the Call Generator AQM configuration, the uplink AQM module is housed in the Call Generator. The license permits connecting any number of downlink AQM modules in the application. All equipment required for AQM, including a cable kit and other accessories, is sold separately. The AQM option is also required for merging AQM uplink data (from Call Generator) into logfiles, which is done using the logfile export function described in the Users Manual, section 11.7.

3.3.3.

Licensing for VoIP

A separate license option is offered for VoIP testing, including AQM for VoIP.

3.3.4.

Network (Floating) Licenses

Instead of fixed single-user licenses, the customer can purchase network licenses that can be shared among multiple users. See chapter 4 regarding the practical use and scope of network licenses.

3.4.

Accessories

In addition to the standard packages and separately purchased user terminals and scanners, the following optional items can be delivered: GPS units TEMS Pocket-enabled phones

NT12-6999 ver 1.0

TEMS Investigation 14.1 Getting Started Manual

Equipment cases Indoor backpack including battery solution

The indoor backpack contains everything needed to operate phones and scanners in indoor and pedestrian environments. The backpack comes in two sizes, of which the larger accommodates both phones and a scanner, while the smaller is intended for phones only. Please contact Ascom for further information on the available accessories.

10

Chapter 4. Licensing

4.

Licensing

This chapter describes the fundamentals of the licensing in TEMS Investigation 14.1. Regarding the permissions granted by the basic TEMS Investigation licenses, see sections 3.1 and 3.2. Regarding the range of additional license options, see section 3.3. The installation of licensing-related drivers, as well as all procedures involved in software-based licensing, are covered in chapter 6.

4.1.

Licensing Solutions

Licensing for TEMS Investigation is based on the HASP technology. Both hardware-based (HASP HL) and software-based (HASP SL) licensing can be used. See sections 6.1 and 6.2 respectively. Further, licenses associated with TEMS Investigation can be either local or network licenses. The technical implementation of each license type naturally differs between HASP HL and HASP SL: A local license is embodied (HASP HL) in a hardware key which is inserted into the PC, or (HASP SL) in a software key that is installed on it. (HASP SL) by connecting to a license server and checking out a software key from that server.

A network license is obtained on the client machine1

4.2.

Local vs. Network Licenses

If HASP SL is used, either a local license or a network license can be used for all TEMS Investigation functions.

1. HASP HL is not used in network license configurations.

NT12-6999 ver 1.0

11

TEMS Investigation 14.1 Getting Started Manual

For HASP HL only local licenses exist, as stated in section 4.1.

4.3.

License Requirements

A license is always required to run TEMS Investigation. Without a license you cannot launch the application. Device Connect and Logfile Recording For a device to be connectable (possible to activate) in TEMS Investigation, it must be covered by your license options. See section 3.3.1. Logfile Load Within the confines of the cellular technologies supported in the package, it is possible in TEMS Investigation to load and analyze logfiles recorded with devices for which you have no license. For example, even if you have not purchased the license option for data collection with Qualcomm devices, you can still load logfiles recorded with Qualcomm devices. However, loading of logfiles recorded with software other than TEMS Investigation (e.g. TEMS Automatic) requires a Base Software Package license. See section 3.1.

4.4.

Drivers for HASP Key

The HASP key drivers (for HASP HL and SL alike) are installed automatically along with TEMS Investigation. If you are going to use HASP SL network licensing, you must install the HASP driver on the license server PC; see section 6.2.2 for instructions. Note: Do not use any other HASP driver than the one delivered with TEMS Investigation. Do not update the HASP driver via Windows Update; the driver thus obtained is not identical and does not contain certain features necessary for using software-based licensing with TEMS Investigation.

12

Chapter 4. Licensing

4.5.

Inspecting the Scope of Your License

You can check what is covered by your (local or network) license in the HASP Admin Control Center, accessed from Help Hasp Admin Control Center Features. The meanings of the HASP key Feature Ids are given in the table that follows. It includes certain Feature Ids used only with older versions of TEMS Investigation.
Feature Id 35 41 42 43 47 48 51 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 Release/Option TEMS Investigation 10.1 TEMS Investigation 11.0 TEMS Investigation 12.0 TEMS Investigation 12.1 TEMS Investigation 13.0 TEMS Investigation 13.1 TEMS Investigation 14.x ST Ericsson A (Reserved) (Reserved) Nokia C Qualcomm B Qualcomm C Qualcomm D PCTel scanner Anritsu scanner DRT scanner Datang A EMP A Motorola A Motorola B PESQ (Reserved) MTU/Pocket logfiles, reading EFEM/Netmon logfiles, reading

NT12-6999 ver 1.0

13

TEMS Investigation 14.1 Getting Started Manual

Feature Id 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 136 138 139 140 141 142 143 144 145 146 147 148 149 151 152 153

Release/Option MDM logfiles, reading Connect of 1 device Connect of 3 devices Connect of 6 devices General (Reserved) WiMAX technology CDMA technology GSM technology WCDMA technology LTE technology TD-SCDMA technology Samsung A Connect of 2 devices Connect of 4 devices Connect of 5 devices Qualcomm E LG A Andrew scanner A (Reserved) VoIP Rohde & Schwarz scanner A Iperf SSH2 ST Ericsson B Qualcomm F GCT A Sequans A Qualcomm G Altair A Via A Compound Logfile Reader (reading pre-14.0 logfiles) TRP TI Reader (reading *.trp logfiles)

14

Chapter 4. Licensing

Feature Id 154 156 158 159 160 163

Release/Option TRP Writer (writing *.trp logfiles) Sony A Transcom scanner A Hisilicon A POLQA, 12 devices Anritsu scanner B

NT12-6999 ver 1.0

15

TEMS Investigation 14.1 Getting Started Manual

5.

Installing TEMS Investigation

This chapter covers requirements on the PC, installation of the TEMS Investigation software, and other installation issues.

5.1.
5.1.1.

PC Hardware and Software Requirements


Hardware

TEMS Investigation 14.1 is designed to run on a standard PC and interfaces with the connected devices mainly through USB or serial ports. If network licenses (see section 4.1) are to be used, the PC hosting the license server must have at least one free USB port. Processor and RAM requirements are strongly dependent on what external devices are connected and what tasks they perform. The recommended minimum configuration is: Pentium T7200 or AMD TL-58 class CPU, preferably with dedicated graphics card from ATI or nVidia; 1 GB RAM. Please note that it is not advisable to collect data with more than one device, or to collect data in an LTE or HSPA network, using this configuration. LTE data service testing at high throughput rates (above 50 Mbit/s) with a Qualcomm chipset based device requires a very powerful PC processor, for example a 2nd generation Intel Core i5 or comparable Intel Core i7. For testing with a large array of connected devices (for example, 68 devices plus GPS), an Intel Core i7-nnnQM/XM, Intel Core i7-2nnnQM/XM, or equivalent processor is necessary. Other hardware requirements: One USB port for each user terminal One USB port for each stand-alone AQM module One or two USB port(s) for SRU (see the Users Manual, section 8.1.3) USB port for PCTel SeeGull MX/EX/LX MM2/PCTel PCT scanner USB port for Anritsu ML8780A scanner

16

Chapter 5. Installing TEMS Investigation

USB port for Transcom scanner USB port for equipment case USB port for HASP HL SRM hardware key USB port, Bluetooth port, or serial port for GPS Serial port for PCTel SeeGull LX dual-band/single-band scanner Serial port for Anritsu ML8720 scanner Ethernet port for Andrew scanner Ethernet port for DRT scanner Ethernet port for Rohde & Schwarz scanner ExpressCard/34 slot or PC Card slot for any data card user terminals Sound card and loudspeakers for event audio indications Graphics: 1024 768 (SVGA) with at least 16 bit colors (High Color) Enough disk space to accommodate temporary files created during logfile recording and logfile analysis Note: During drive testing, it must be ensured that the PC and all devices connected to it have adequate power supply for the duration of the test. This is especially important to bear in mind if you are using a USB hub that is not self-powered (i.e. has no external power supply). With multiple devices connected, it may even be necessary to take the precaution of providing extra power via UPS or extra batteries during drive testing. If the power provided is insufficient, problems may arise with device drivers, which in turn may cause malfunctions in Windows and possibly data loss. Ascom takes no responsibility for such data loss.

5.1.2.

Operating System

The following operating systems are supported: Windows 7 with Service Pack 1 (x86, x64) Windows Vista with Service Pack 2 (x86) Windows XP with Service Pack 3 (x86)

In addition, all the latest Windows updates should always be installed.

NT12-6999 ver 1.0

17

TEMS Investigation 14.1 Getting Started Manual

Supported languages are English (U.S.), Chinese (simplified characters), and Japanese. Be sure to use the appropriate drivers for the operating system used. See also chapter 7.

5.1.3.

Software

Below is a list of other third-party software that is required for various tools and actions in TEMS Investigation. When installing third-party software, administrator rights are required, and possibly (depending on UAC settings) the installation must be run using the Run as administrator option. .NET Framework version 4.0 must be installed on the PC. It is included on the TEMS Investigation installation CD. Internet Explorer 6 or higher required for Report Generator and online help. Internet Explorer 9 required for HTTP download testing with Internet Explorer: see the Users Manual, section 20.16.3.11. Microsoft Core XML Services (MSXML) 6.0 required for support of XMLformat cell files if Windows XP is used. (In Windows 7 and Windows Vista, MSXML 6.0 is included.) Microsoft DirectX 9.0c required for video streaming measurements.

5.2.
5.2.1.

Other Hardware Requirements


HASP License Server

Supported operating systems are: Windows 7, Windows Vista, Windows XP, Windows 2000; Windows 2008 Server, Windows 2003 Server (32-bit versions throughout). Hardware requirements do not need to be stated since running the HASP License Manager is not a CPU-intensive task.

5.2.2.

Audio Quality Measurements

For CS voice audio quality measurements, one of the following additional hardware components is needed. Compare the Users Manual, chapter 35:

18

Chapter 5. Installing TEMS Investigation

AQM module(s) and either Call Generator (see chapter 9 of this document) or Mobile Receiving Unit, MRU Audio Capturing Unit, ACU.

5.2.3.

VoIP Testing

VoIP testing requires two PCs, each running an instance of TEMS Investigation. See the Users Manual, section 20.16.7.9, and the technical paper VoIP Testing with TEMS Investigation, found on the installation CD in the subdirectory Documents.1

5.2.4.

Video Streaming

For video streaming measurements a streaming server is needed: Darwin Streaming Server (version 5.5.5) or Helix Mobile Server (version 10 or 11).

5.2.5.

UDP Testing with TEMS UDP Server

UDP testing makes use of the TEMS UDP Server application, which is installed on the PC acting as server. Requirements on the PC where TEMS UDP Server is going to be run are stated in the document TEMS UDP Server Users Manual, found on the TEMS Investigation installation CD. Please note that the UDP client in TEMS Investigation 14.1 requires a TEMS UDP Server from TEMS Investigation 12.0 or later; the client is not compatible with older TEMS UDP Servers. Multiple TEMS UDP Servers from TEMS Investigation 12.0 or later cannot coexist on the same machine. One such server can however coexist with one from TEMS Investigation 11.x.

5.2.6.

Network Bandwidth (UDP/TCP) Testing with Iperf

Network Bandwidth testing uses the Iperf software. Iperf is not supplied with TEMS Investigation but can be downloaded from sourceforge.net/projects/ iperf (version 2.0.5 or later).

1. Two TEMS Investigation licenses are thus required for VoIP testing, as well as the VoIP license option (see section 4.5).

NT12-6999 ver 1.0

19

TEMS Investigation 14.1 Getting Started Manual

Iperf can be installed on a Linux, Unix, or Windows platform. The TEMS Investigation functionality has been verified with Iperf installed under: Windows Server 2008 R2, Windows 7 OpenSUSE 11.2

Installation for SSH2 If you wish to do Iperf testing over the secure SSH2 protocol, you must install TEMS Investigation by executing a special MSI file named TEMS_Investigation_13.0_SSH2.msi (instead of following the usual procedure described in section 5.3). To run the Network Bandwidth activity over SSH2, the PC must have a HASP key installed with the SSH2 license option encoded. Network-to-terminal Mapping (Linux/Unix) Under Linux/Unix, the Network Bandwidth activity requires that the server map the network port to terminal vt100. Map the port by editing a line in /etc/profile: tset -I -Q -m network:vt100 An incorrect mapping will cause the following error: tset: unknown terminal type network Terminal type?

5.3.

Installing TEMS Investigation

You must have administrator rights on the PC to be able to install TEMS Investigation. Insert the installation CD and follow the on-screen instructions. If for some reason the installation does not start automatically, run the file SetupTEMSInvestigation.exe. TEMS Investigation will now be installed, by default to the directory C:\Program Files\Ascom\TEMS Products\TEMS Investigation 14.1. A number of utilities are also installed: HASP SRM Remote Update, used to update license options in HASP keys. See the document TEMS HASP SRM Key Information which is found on the installation CD in the subdirectory Documents.

20

Chapter 5. Installing TEMS Investigation

Manual UE Configuration, used to assist TEMS Investigation in detecting certain types of devices. See section 7.1 of this volume and section 8.3.4 of the Users Manual. TEMS Pocket Positioning Tool, used to assign geographical coordinates to TEMS Pocket logfiles recorded by pinpointing (no GPS). See the TEMS Pocket Positioning Tool Users Manual, included on the installation CD in the subdirectory Documents. TEMS Investigation Computer Diagnostics, used to rate the capabilities of the PC and check its current settings, matching the findings with the requirements posed by TEMS Investigation. This utility is launched in the course of the installation. See chapter 8 for full coverage of TEMS Investigation Computer Diagnostics.

Once installed, the applications and utilities can be run by choosing Start [All] Programs Ascom TEMS Products.

5.4.

Automatic Check for TEMS Investigation Software Updates

Note: UAC must be turned off for this feature to work. When starting TEMS Investigation for the first time after installation, you are invited to connect to an Ascom server and find out if there is a newer TEMS Investigation software version available. A web page opens. If a newer version exists, you are asked whether or not to install it. If you accept the update, it will be downloaded, whereupon TEMS Investigation terminates automatically and the update is installed. The update check prompt also appears on application start-up if no update check has been performed over the last 28 days. Alternatively, you can manually initiate the update check from the about box (Help menu About TEMS Investigation 14.1) by clicking the button Tech Support and then Check for updates:

NT12-6999 ver 1.0

21

TEMS Investigation 14.1 Getting Started Manual

Because of the automatic shutdown that takes place, be sure to save your work before accepting an update.

5.5.

Uninstalling TEMS Investigation

To uninstall TEMS Investigation software, follow the steps below. Windows 7, Windows Vista Open the Windows Control Panel and select Programs and Features. Select TEMS Investigation 14.1 in the list of installed programs. Click Uninstall and confirm removal if prompted to do so. The software will now be uninstalled.

Windows XP Open the Windows Control Panel and select Add/Remove Programs. Select TEMS Investigation 14.1 in the list of installed programs. Click Change/Remove and confirm removal if prompted to do so. The software will now be uninstalled.

22

Chapter 6. Installing and Using HASP Software Protection

6.

Installing and Using HASP Software Protection

This chapter covers in detail how HASP software protection is applied to TEMS Investigation and how to handle it in practice. Either hardware-based licensing (HASP HL, section 6.1) or software-based licensing (HASP SL, section 6.2) can be used. Regarding general aspects of licensing for TEMS Investigation, see chapter 4.

6.1.

Hardware-based Licensing: HASP HL

The HASP SRM driver is installed automatically on the PC along with TEMS Investigation. Only local (as opposed to network) licenses exist, and no further configuration is required.

6.2.

Software-based Licensing: HASP SL

For HASP SL, too, there is a choice between local licenses (section 6.2.1) and network licenses (section 6.2.2).

6.2.1.

HASP SL Local License Installation

Here is how to install a local HASP SL license on a client machine. Install TEMS Investigation. In the process, the HASP SRM driver is installed automatically on the PC. Run the file hasprus.exe which is also found on the TEMS Investigation installation CD. From this session you obtain a file with extension .c2v. See also the document TEMS HASP SRM Key Information which is found on the installation CD in the subdirectory Documents. Send the .c2v file to TEMS support. You will receive a .v2c file in return. Run hasprus.exe again to apply the .v2c file to your PC.

NT12-6999 ver 1.0

23

TEMS Investigation 14.1 Getting Started Manual

6.2.2.
6.2.2.1.

Using HASP SL Network Licenses


TCP Port Usage

By default, TCP port 1947 is used between server and client. Due to firewall restrictions or other issues, you might need to change this port. If necessary, do as follows: Under HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\ hasplms\Parameters, create a registry entry Port on both server and client. Type: REG_DWORD or REG_SZ. The preferred type is REG_SZ since the default display of REG_DWORD is hexadecimal, which may be misleading. Value: Set the value to the desired port number.

Restart the LLM Server (Sentinel HASP License Manager) or reboot the machine.

The port assignment can be verified with the command netstat -a. If applicable, substitute your own TCP port number for 1947 when following the instructions below.

6.2.2.2.

HASP SL License Server Installation

If you are going to use HASP SL network licenses, you must first configure the machine that is going to act as license server: Install the HASP SRM driver supplied on the TEMS Investigation installation CD. Run the file hasprus.exe which is also found on the TEMS Investigation installation CD. From this session you obtain a file with extension .c2v. See the document TEMS HASP SRM Key Information which is found on the installation CD in the subdirectory Documents. Send the .c2v file to TEMS support. You will receive a .v2c file in return. Run hasprus.exe again to apply the .v2c file to the license server machine. Now configure the server using the Admin Control Center web page at Help Hasp Admin Control Center. Go to Configuration Detachable Licenses tab and check the option Enable Detaching of Licenses.

24

Chapter 6. Installing and Using HASP Software Protection

By adjusting the parameter Max. Detach Duration, you can control the maximum duration for which a license may be detached. After this time, the license will be automatically disabled on the client machine and restored to the license server. It is advisable to keep the maximum detach duration fairly short, since if a client computer crashes the license will be unavailable until the expiry date. The minimum value is 1 day. Then switch to the Access from Remote Clients tab and enter whatever is suitable under Access Restrictions. By default, a license can be detached from any machine; if you want to restrict the set of machines and/or users that should have access to the HASP License Manager, proceed according to the help provided for this tab (Help link in lower right corner).

6.2.2.3.

HASP SL Network License: Online Detach/Attach

Once the license server has been configured, it can send out licenses to client machines. Here are the steps to perform on the client PC in order to check out (detach) a license online from the license server, and to return (attach) a license to the server. Configure the client PC using the Admin Control Center web page, Help Hasp Admin Control Center. Go to Configuration Detachable Licenses tab and check the option Enable Detaching of Licenses. Then go to the Access to Remote License Managers tab. Under Specify Search Parameters, enter the IP address or name of the license server machine. Regarding the other settings, see the help provided for this tab (Help link in lower right corner).

On the ACC web page, under Products, locate TEMS Investigation in the list. Click the Detach button for that product.

Note: For practical examples of how to work with HASP SL licenses when multiple TEMS products and product options are involved, please turn to section 6.2.2.5.

NT12-6999 ver 1.0

25

TEMS Investigation 14.1 Getting Started Manual

Online is the default detach method when the client has a network connection to the license server. (No action needed.) Specify an expiration date for the detach operation. This setting controls how long the license can be detached at a time, and it is configurable within the limit imposed by the Max. Detach Duration setting on the license server; compare section 6.2.2.2. Click the Detach/Attach button.

You should now receive a message License Detached Successfully:

Furthermore, the Products page should now be updated with the information that a license has been detached for TEMS Investigation. The license will expire after the period specified at detach time; after this time you will need to detach the license again. Alternatively, you can actively return (attach) the license to the server before it expires. This is done as follows:

26

Chapter 6. Installing and Using HASP Software Protection

Navigate to the Products page and click the Cancel License button for the relevant product.

On the next screen, confirm by again clicking the Cancel License button.

This message will appear:

The information on the Products page will also be updated once more to reflect the reattach of the TEMS Investigation license:

NT12-6999 ver 1.0

27

TEMS Investigation 14.1 Getting Started Manual

6.2.2.4.

HASP SL Network License: Offline Detach/Attach

License detach and attach can alternatively be done offline, without the client and server ever communicating directly over a network connection. Configure the client PC using the Admin Control Center web page, Help Hasp Admin Control Center. Go to Configuration Detachable Licenses tab and check the option Enable Detaching of Licenses. Then go to the Access to Remote License Managers tab. Under Specify Search Parameters, enter the IP address or name of the license server machine. Regarding the other settings, see the help provided for this tab (Help link in lower right corner). If the client PC is not yet known to the HASP license server, you need to identify it to the server the first time around.1 On the Admin Control Center web page, go to Diagnostics, and click the button Create ID File. This generates a diagnostics file (with extension .id) identifying your machine.

Send the diagnostics file to the HASP license server admin. Here is how the server admin proceeds in order to detach a license. The admin selects the Update/Attach option:

The admin then clicks the Detach button next to the relevant product:

1. If (for example) you have detached a license online to this client PC at some point, the PC will already be known to the server, and the identification step is not needed. The license server admin can then send you an .h2r file directly.

28

Chapter 6. Installing and Using HASP Software Protection

The admin selects your client PC as recipient machine and sets an expiration date for the license.

Finally the admin saves the detached license as a file with extension .h2r and sends it to you. Save the .h2r file on your client PC, then open the Admin Control Center web page, go to Update/Attach, and browse for the .h2r file. Then click the Apply File button. (This is the same dialog that the admin used to process your .id file.)

NT12-6999 ver 1.0

29

TEMS Investigation 14.1 Getting Started Manual

A confirmation message will appear, and the Product page will be updated with the information that a license has been detached for TEMS Investigation. See below.

Note: For practical examples of how to work with HASP SL licenses when multiple TEMS products and product options are involved, please turn to section 6.2.2.5. The license will expire after the period specified by the HASP license server admin at detach time. After this time you will need to detach the license again. Alternatively, you can actively return (attach) the license to the server before it expires. This is done as follows: Navigate to the Products page and click the Cancel License button for the relevant product.

30

Chapter 6. Installing and Using HASP Software Protection

On the next screen, again click the Cancel License button:

A file with extension .r2h is created; save this file.

Send the .r2h file to the HASP license server admin. The server admin will then apply the .r2h file to the server, thereby reattaching the license. (The same Apply File procedure is used as for offline detach, which was covered earlier in this section.)

The information of the Product page will again be updated to reflect the reattach of the TEMS Investigation license.

6.2.2.4.1.

Disabling Offline Detach

It is possible to disable offline detach of licenses. This may be desirable in order to decrease the risk of detaching licenses to non-existing clients. To disable offline detach, do as follows:

NT12-6999 ver 1.0

31

TEMS Investigation 14.1 Getting Started Manual

In the file C:\Program Files (x86)\Common Files\Aladdin Shared\HASP\hasplm.ini, add the line disable_offline_detach = 1 (it does not matter in which section this line is entered). Then restart Sentinel Local License Manager.

When detaching a software-based license, the offline option should now be disabled, and this text should be displayed: (Offline Detach is disabled by configuration).

6.2.2.5.

Handling HASP SL Network Licenses for TEMS Products: Examples

For simplicity the instructions given so far in section 6.2.2 have assumed that it is immediately obvious what type of license to detach. If you have purchased multiple TEMS products, and/or multiple TEMS product packages with different options, things are slightly more complicated. This section clarifies how to proceed in typical configurations of this kind. Consider the following set of TEMS product packages (Products 13) with different combinations of products and license options:

32

Chapter 6. Installing and Using HASP Software Protection

Each of these packages will appear as a product in ACC, as indicated in the diagram. You always check out entire products in the ACC interface, not individual license options. These products, however, do not necessarily correspond in one-to-one fashion to TEMS PC applications, as can be seen in the diagrams just given. If you want to do LTE or CDMA drive testing or both, you check out Product 1. If you want to do both LTE and WiMAX testing, you need to check out both Product 1 and Product 2; but note that you will still only be running one TEMS Investigation application. (You cannot just check out Product 1 and then somehow add only the WiMAX option from Product 2.)

Another fact to keep in mind is that each TEMS product user always needs to check out his or her own license. Suppose that Product 1 has been purchased, and user A wants to use TEMS Investigation while user B wants to use TEMS Discovery. The two users then need one license each; it is not possible to check out just one license and share it between users A and B. Or suppose that Product 3 has been purchased, and user C wants to study LTE data whereas user D wishes to work with CDMA data. Each of these users must likewise have his or her own license.

NT12-6999 ver 1.0

33

TEMS Investigation 14.1 Getting Started Manual

6.2.2.6.

Monitoring HASP SL License Usage

You can monitor how many licenses are currently checked out and who is using those licenses. This is particularly useful when the number of available licenses is running low. Go to Help Hasp Admin Control CenterProducts. The Products page in Admin Control Center lists all products that are available on all accessible HASP License Managers on the network. In the Detached column is indicated the number of licenses that are currently detached from the HASP SL key to which the product is locked. Click on a cell in the Detached column to view data about the recipient machines to which the detached licenses have been allocated. In the Available column is indicated the number of licenses that are currently available for detachment from the HASP SL key to which the product is locked.

6.3.

Updating HASP Keys (HL/SL)

When updating a HASP key of any type (i.e. whether HL or SL), you proceed much in the same way as when first obtaining a HASP SL (software-based) key. HL and SL are described separately below for maximum clarity. For further information, see the document TEMS HASP SRM Key Information which is found on the installation CD in the subdirectory Documents.

6.3.1.

Updating HASP HL Keys

1. Make sure you have installed TEMS Investigation. 2. Plug your HASP HL key into the PC. 3. Navigate to the Application folder beneath the TEMS Investigation installation directory and run the file hasprus.exe. This dialog box opens:

34

Chapter 6. Installing and Using HASP Software Protection

4. Now collect the key information by clicking the Collect information button. 5. If you also have a HASP SRM SL (i.e. software-based) key installed on the machine, a dialog will appear at this point prompting you to choose which key to update. Select the HASP HL key.

6. A file with extension .c2v is created. Choose a suitable file name and save the file. 7. E-mail the .c2v file to customer support. Contact information is found at www.ascom.com/networktesting under the link TEMS Support. 8. From customer support you will receive a file with extension .v2c. Once you have that file, navigate to the TEMS Investigation folder and run the file hasprus.exe. The Remote Update System dialog opens. 9. Select the Apply License Update tab. 10. Browse to locate the .v2c file, and click the Apply update button:

NT12-6999 ver 1.0

35

TEMS Investigation 14.1 Getting Started Manual

11. The result of the operation will be displayed in the main window of the dialog. When you have successfully applied the HASP license, exit the Remote Update System application.

6.3.2.

Updating HASP SL Keys

1. Make sure you have installed TEMS Investigation. 2. Navigate to the Application folder beneath the TEMS Investigation installation directory and run the file hasprus.exe. The HASP SRM RUS dialog opens to the Collect Key Status Information tab (as in section 6.3.1, step 3). 3. Click the Collect information button. What this operation does in the HASP SL case is to take a digital fingerprint of your hard drive, uniquely identifying the drive. 4. If you also have a HASP SRM HL hardware key plugged into the PC at this point, a dialog will appear prompting you to choose which key to update. Select the HASP SL key. 5. Just as for HASP SRM HL, a file with extension .c2v is created. Save this file. 6. E-mail the .c2v file to customer support. Contact information is found at www.ascom.com/networktesting under the link TEMS Support. 7. From customer support you will receive a file with extension .v2c. Once you have that file, navigate to the TEMS Investigation folder and run the file hasprus.exe. The Remote Update System dialog opens. 8. Select the Apply License Update tab. 9. Browse to locate the .v2c file, and click the Apply update button. 10. The result of the operation will be displayed in the main window of the dialog. When you have successfully applied the HASP license, exit the Remote Update System application.

36

Chapter 6. Installing and Using HASP Software Protection

6.4.

Sentinel HASP Runtime Network Activity

Note: This information is reproduced from SafeNets Sentinel HASP documentation. This section describes the type of network activity that occurs in the communication between: an application (protected using Sentinel HASP) and the local HASP License Manager (referred to as local communications). the local HASP License Manager and one or more remote HASP License Managers (referred to as remote communications).

Details regarding local communications and remote communications are provided on the pages that follow. This section is intended to assist IT managers who want to understand how runtime activity on the network may impact the way they set up their network rules and policies. Sentinel HASP communicates via TCP and UDP on socket 1947. This socket is IANA-registered exclusively for this purpose.

6.4.1.

Local Communications

This section describes communication between a protected application and the local HASP License Manager service. A protected application communicates only with HASP License Manager on the computer where the application is running, regardless of whether the HASP HL or SL Key is located on the same computer or on a remote computer.

NT12-6999 ver 1.0

37

TEMS Investigation 14.1 Getting Started Manual

Note: Under Windows, HASP License Manager is a service that is launched automatically by hasplms.exe. Under Mac OS and Linux, the HASP License Manager is a process launched automatically by hasplmd. HASP License Manager service opens socket 1947 for listening (both for UDP packets and TCP packets). IPv4 sockets are always opened (HASP License Manager currently does not work without IPv4 installed). IPv6 sockets are opened if IPv6 is available.

A protected application tries to connect to 127.0.0.1:1947 TCP to communicate with HASP License Manager. If an application uses multiple sessions, multiple concurrent TCP connections may exist. If a session is unused for a certain number of minutes (at least seven minutes, but the exact number depends on several factors), the session may be closed and automatically re-opened later in order to limit resources used by the application. These local communications currently use IPv4 only. The communication uses binary data blocks of varying size.

6.4.2.

Remote Communications

This section describes communication between the local HASP License Manager service and a remote HASP License Manager service. This type of communication occurs when the protected application is running on a different computer from the computer where the HASP HL or SL Key is installed. The protected application communicates only with the local HASP License Manager on the computer where the application is running, as described in section 6.4.1. The local HASP License Manager discovers and communicates with the License Manager on the computer containing the HASP Key using one of the following methods: The local HASP License Manager issues a UDP broadcast to local subnets on port 1947 using: IPv4 (always) IPv6 (if available)

38

Chapter 6. Installing and Using HASP Software Protection

You can disable this broadcast by clearing the Broadcast Search for Remote Licenses checkbox in the Admin Control Center Configuration screen. The local License Manager issues a UDP ping packet to port 1947 for all addresses specified in the Admin Control Center field Specify Search Parameters. These addresses may be individual machine addresses or broadcast addresses.

All License Managers found by the discovery process are then connected via TCP port 1947, using IPv4 or IPv6 as detected during discovery, and data regarding the remote HASP Keys are transferred. This discovery process is repeated at certain intervals. (The interval size depends on a number of factors, but it is generally not less than five minutes.) UDP packets sent and received in the discovery process contain the License Manager GUID (40 bytes of payload data). When starting or stopping a License Manager, and when adding or removing a HASP Key, a UDP notification packet is sent, containing the License Manager GUID and a description of the changes encountered. This is done to allow other License Managers to update their data before the next scheduled discovery process. TCP packets between two License Managers on different computers use HTTP with base-64 encoded data in the body section.

NT12-6999 ver 1.0

39

TEMS Investigation 14.1 Getting Started Manual

7.

Installation of Device Drivers

Note: The drivers are delivered on a separate CD in a ZIP archive. You must insert this CD manually after installing TEMS Investigation and unpack the ZIP archive to a location of your choice. That location is referred to as ...\Drivers below.

7.1.

Installation of USB Drivers for User Terminals

USB drivers are provided for all UMTS terminals that can be purchased with TEMS Investigation. For other UMTS terminals and for all CDMA terminals, drivers must be obtained from the supplier. The first time you plug in a terminal, you will be prompted to locate its drivers by browsing to the correct directory. On your doing so the drivers will be installed. Supplier- and device-specific details follow below. If other drivers are already installed on the PC, make sure that the correct drivers become associated with the device modem. Also make sure that you do not install other (non-TEMS-compatible) drivers from the same supplier later on.

7.1.1.

Sony Ericsson Phones

When prompted, point to ...\Drivers\Sony Ericsson\<model name>. Regarding W995 phones with firmware version R1F or later, see section 10.4.

40

Chapter 7. Installation of Device Drivers

Android Phones (Qualcomm Chipset Based): How to Install Drivers 1. Connect the phone to the PC. Windows will try to find drivers; when the automatic driver installation fails, open the Device Manager on your computer. 2. Locate the phone with missing drivers under Device Manager Other devices. 3. Right-click the first SEMC HSUSB Device and select Update Driver Software Browse my computer for driver software. 4. Browse all the way to the directory where the applicable driver for your operating system is stored; note that 32-bit and 64-bit Windows must be distinguished. Example of path: ...\Drivers\Sony Ericsson\x10\Win64. 5. Click Next. 6. Repeat the procedure for the remaining SEMC HSUSB Device items.

7.1.2.

Datang Phones

Before plugging in the phone, do as follows: Install the driver delivered with the Datang phone. After completing the driver installation, go to the directory <TEMS Investigation install dir>\Application and run the file DatangPostInstall.exe. This EXE writes the AT command AT+CGDCONT=1,"IP","cmnet",,,;+CGEQREQ=1,4 to the registry, thereby accomplishing two things: Changing the number of available Datang ports from 3 (default) to 4 (the number of ports needed by TEMS Investigation). Setting the APN to the string cmnet for all Datang data modems. If you want to name the APN differently, run DatangPostInstall.exe from a Windows command prompt with the desired APN name as argument, for example: DatangPostInstall myapn. Compare section 10.6.1.

Now plug in the phone. Finally, run the file ManualUEConfig.exe which is also found under <TEMS Investigation install dir>\Application. A window titled TEMS Investigation Manual UE Configuration opens. Select the Port Configuration tab.

NT12-6999 ver 1.0

41

TEMS Investigation 14.1 Getting Started Manual

Click the New button. The Manage Device dialog appears:

Name Type Air Interface Port Data Port AT Port Control Port UE Id Port

Enter a name for the phone. (The string does not show anywhere else in TEMS Investigation.) Select TD-SCDMA Datang. Select the port to use for air interface measurements. (Consult Datang documentation to find this out.) Select the port to use for data service measurements. Select the port to use for AT commands. Select the port to use for video call setup. Select the physical USB port here.

7.1.3.

Hisilicon Chipset Based Devices

To be able to activate a Hisilicon chipset based device in TEMS Investigation, you need to have a software utility called Hisilicon UE Agent installed and running on the PC. This software is available in the directory ...\Drivers\Huawei\E398s. Note: The Mobile Partner software delivered with the Hisilicon device is not compatible with TEMS Investigation and must be turned off.

42

Chapter 7. Installation of Device Drivers

7.1.4.

Nokia Phones

Before plugging in the phone, you must run the MSI file found in the directory ...\Drivers\Nokia. This installs the driver files to the directory C:\Program Files\Nokia\Connectivity Cable Driver. After plugging in the phone, point to this directory when prompted. You must also select PC Suite in the menu that appears in the phone display.

7.1.5.

Qualcomm Chipset Based Devices

This applies to all supported Qualcomm chipset based devices. Before plugging the device into the PC, use the software application delivered with the device to install the requisite drivers. Regarding the possible use of the Manual UE Configuration utility, see the Users Manual, section 8.3.4. (Normally it is not needed.)

7.1.6.

Samsung Galaxy S 4G, Samsung Infuse 4G

When prompted, point to ...\Drivers\Samsung\Galaxy S4G\edisonV5_22_1_0-customer-checked.

7.2.

Installation of Driver for SRU

Before plugging the SRU into the PC, install the driver by executing the file ...\Drivers\TEMS SRU\Install.bat. For further instructions, see the readme document which is supplied in the same directory. Drivers are also available on the internal SSD drive. However, to ensure that the latest version is installed, use the driver installation CD.

7.2.1.

Installing Drivers from Driver Installation CD

1. When you run the file ...\Drivers\TEMS SRU\Install.bat, a script window will open:

NT12-6999 ver 1.0

43

TEMS Investigation 14.1 Getting Started Manual

2. Some warnings will pop up during the installation. Choose to Install device software from Ericsson AB.

3. Choose to Install device software from Ascom Network Testing AB.

4. Connect the red and black USB connectors, or the black USB connector and the additional power cable (special 12 V adapter needed), to the computer. Windows will detect the F3607 module and install drivers.

5. When the installation is finished, some AutoPlay dialogs may open. Close any such dialogs.

44

Chapter 7. Installation of Device Drivers

7.2.1.1.

Extra Steps for Windows 7

To prevent problems detecting the SRU scanner in TEMS Investigation, terminate the Mobile Broadband Service process mini_WMCore.exe. 1. To check if the process mini_WMCore.exe is running, open Windows Task Manager Processes.

2. Stop the process by choosing Windows Task Manager Services and clicking the Services button.

NT12-6999 ver 1.0

45

TEMS Investigation 14.1 Getting Started Manual

3. Right-click the Mobile Broadband Service item and choose Properties.

4. Configure the settings as shown below. That is, set Startup type to Manual, and under Service status click the Stop button to stop the service if it is running.

5. TEMS Investigation is now able to detect the SRU scanner.

46

Chapter 7. Installation of Device Drivers

7.2.2.
7.2.2.1.

Installing Drivers from Internal SSD Drive


Installing Drivers in Windows 7

1. Plug in the red and black USB connectors. The internal SDD drive is automatically detected, and two AutoPlay windows will open: TEMSDRIVERS and TEMSUSER.

2. Close the TEMSUSER window. 3. In the TEMSDRIVERS window, choose Open folder to view files.

4. Right-click on install.bat and choose to Run as Administrator. A script will install the necessary drivers. When the installation has finished, press any key to close the script window.

NT12-6999 ver 1.0

47

TEMS Investigation 14.1 Getting Started Manual

5. Disconnect the SRU scanner, wait a short while, and then plug in the USB connectors again. Windows will detect the F3607 module and install drivers.

7.2.2.2.

Installing Drivers in Windows XP

1. Plug in the red and black USB connectors. Three windows will open: Found New Hardware Wizard, TEMSUSER, and TEMSDRIVERS. (The windows may open on top of each other.) 2. Close the TEMSUSER window. 3. In the TEMSDRIVERS window, choose Install TEMS drivers and TEMS device manager. Click OK. This will start the installation of the drivers.

48

Chapter 7. Installation of Device Drivers

4. Ignore all warnings that pop up during the installation. Choose Continue Anyway in each case. 5. The installation is finished when the text TEMS Drivers and TEMS Device Manager installed shows. Press any key to continue.

6. In the window Found New Hardware Wizard, choose No, not this time and then Next. If you cannot find the window, disconnect the black connector and then reconnect it after a while.

NT12-6999 ver 1.0

49

TEMS Investigation 14.1 Getting Started Manual

7. Choose Install the software automatically, and click Next. Continue to ignore all warnings that pop up during the installation, clicking Continue Anyway on each occasion.

8. Click Finish to finish the installation. 9. The guide Found New Hardware Wizard will now start for one of the F3607 modules. Choose No, not this time and then Next. If the guide does not start, disconnect the black connector and then reconnect it after a while. 10. Continue to ignore all warnings that pop up during the installation, clicking Continue Anyway. 11. Click Finish to finish the installation. 12. When Windows starts new hardware wizards, just continue with the instructions from step 9.

7.3.

Installation of USB Driver for Anritsu Scanners


Anritsu ML8780A

7.3.1.

Use the driver files delivered with the scanner. On plugging the scanner into the PC, when prompted to locate the scanner driver, point to the file ML8780USB.inf.

50

Chapter 7. Installation of Device Drivers

7.4.
7.4.1.

Installation of USB Driver for PCTel Scanners


PCTel SeeGull LX MM2

PCTel SeeGull LX MM2 scanners use an Edgeport USB driver. The first time you plug in the scanner, you will be prompted to locate its driver. Point to the directory ...\Drivers\PCTEL\LX\MM2\Edgeport.

7.4.2.

PCTel SeeGull EX/MX, PCTel PCT

These scanners use PCTel-specific USB drivers, found in the directory ...\Drivers\PCTEL under EX, MX, and PCT respectively. For instructions on how to install these drivers, see the readme document which is supplied in each directory.

7.5.

Installation of USB Driver for GPS Units

The first time you plug in the GPS, you will be prompted to locate its driver. Point to the appropriate directory (e.g. ...\Drivers\Garmin, ...\Drivers\Globalsat).

7.6.

Installation of Driver for USB-to-RS232 Serial Converter in Equipment Cases/Backpack

This section applies to: the equipment cases TC-1520/1520B/1520C/1520D/1520E the TEMS Indoor Backpack.

The section does not apply to older equipment cases, for which different drivers are used. In order for the PC to detect the COM port of the USB-to-RS-232 serial converter in the equipment case or backpack, some driver files must be installed on the PC. These drivers are always delivered along with the case; they are also found in the directory ...\Drivers\TEMS Case USB to RS232. The first time you connect the case or backpack to the PC, you will be prompted to locate the driver directory; on your doing so the driver will be installed.

NT12-6999 ver 1.0

51

TEMS Investigation 14.1 Getting Started Manual

The TC-1520C case also uses a standard driver for the Moxa hub. This driver is not supplied with the case.

7.7.

Installation of Drivers for AQM Modules

AQM modules, whether stand-alone or mounted in an equipment case, need to be initialized by dedicated driver files. The AQM module does not have any non-volatile memory, so all requisite software and settings must be downloaded to the AQM module each time it is powered on. The first time you connect the case or backpack to the PC, you will be prompted to locate the drivers. For detailed instructions, see the document Driver install instructions.txt stored in the directory ...\Drivers\AQM. Note: AQM drivers supplied with TEMS Investigation versions older than 12.0 cannot be used with the present version of the application.

7.7.1.

General Advice on Driver Installation for AQM Equipment Case/Backpack

When preparing a TC-1520B/1520C/1520D equipment case for use, we recommend that you proceed in the steps described below. The same advice applies to a TEMS Indoor Backpack with AQM modules installed. Before plugging the case into the PC, make sure that you have installed TEMS Investigation (section 5.3) that you have installed all driver files from the separate driver CD (section 7.1) that you have rebooted the PC.

Connect the case to the PC while the case is turned off and does not have any phones installed. Power on the case. Locate all of the drivers in sections 7.6 and 7.7. After the drivers for AQM have been activated, install one phone at a time in the case. For each phone, you will be prompted to locate the phone driver (see section 7.1). Wait each time until the phone driver has been activated before you install the next phone.

52

Chapter 7. Installation of Device Drivers

7.8.

Installation of Drivers for Audio Capturing Unit (TerraTec)

Drivers for the TerraTec box are found under ...\Drivers\TerraTec. The same drivers are used for all supported Windows versions. The installation proceeds in two steps: first run the EXE in the Initial driver folder, then the one under Additional driver. Note: Do not install any of the drivers found on the CD enclosed with the TerraTec box by the supplier. (These drivers are too old.)

NT12-6999 ver 1.0

53

TEMS Investigation 14.1 Getting Started Manual

8.

TEMS Investigation Computer Diagnostics

For TEMS Investigation to operate properly, your computer must be appropriately configured in a variety of respects. With the product is delivered a utility called Computer Diagnostics, which evaluates the current status of the PC and determines how well it is prepared for running TEMS Investigation. Specifically, the utility does the following: Checks a variety of PC settings that have a significant impact on TEMS Investigation performance, particularly with regard to data collection. Feedback in plain text is given on these settings, complete with recommendations for changes. Suitable settings are detailed in section 8.2. Checks hardware capabilities (processor and RAM) and matches them against the requirements of TEMS Investigation. See section 8.1.2.2 for further discussion.

8.1.

Running TEMS Investigation Computer Diagnostics

Launch the Computer Diagnostics utility by choosing Start [All] Programs Ascom TEMS Products Utilities TEMS Investigation Computer Diagnostics.

8.1.1.

Setting Up Test Cases

The Computer Diagnostics utility has a user interface with the following layout:

54

Chapter 8. TEMS Investigation Computer Diagnostics

You can run all listed test cases or a subset of them. To select what items to run, check the boxes on the left as appropriate. To select all items, right-click in the grid and choose Select All from the context menu. To deselect all items, right-click in the grid and choose Deselect All from the context menu.

After deciding what test cases to run: Click the Run Testcases button on the window toolbar. The results of the session are presented in the user interface. See section 8.1.2. A plain-text report with additional detail can also be generated; how to produce this report is explained in section 8.1.3.

8.1.2.
8.1.2.1.

Diagnostics Presentation in User Interface


Windows Settings

The color coding in the Status column has the following interpretation:

NT12-6999 ver 1.0

55

TEMS Investigation 14.1 Getting Started Manual

Green: The setting is OK and does not need changing. Orange: The setting is not OK but can be changed. Red: The setting is not OK and is not editable.

Further details on the outcome appear on the status bar when you select a diagnostic in the window grid. These text strings also appear in the diagnostics report; see section 8.1.3.

8.1.2.2.

Hardware

The PC hardware is evaluated with respect to two sets of criteria: Minimum configuration. These are the minimum requirements for doing data collection with TEMS Investigation. Maximum configuration. These are the requirements for maintaining: (GSM, WCDMA Rel. 99, and CDMA/EV-DO) Up to six concurrent voice calls or up to four concurrent data service sessions. (HSPA, LTE) A maximum of four concurrent data service sessions. Limitations apply according to device driver performance and the data rates attained in the network. Note also that the NDIS driver implementation for some devices might limit the number of data service sessions to only one.

A set of Windows Experience Index (WEI) scores are computed as an assessment of the hardware capabilities, and these scores are compared to predefined thresholds to determine whether they are high enough. The Status column uses colors as follows to indicate the result: Green: All WEI part scores are OK. Red: At least one WEI part score is not OK.

Further details on the outcome, as well as the WEI score thresholds that apply, are indicated on the status bar when you select a hardware configuration diagnostic. These text strings also appear in the diagnostics report; see section 8.1.3.

8.1.2.3.

Further Columns in the Computer Diagnostics Window

The Impact column indicates the relative importance of the various items tested. (The weighting shown does not form the basis for a composite score of any kind; it is just a visual indication.) The Read-only column is currently not used.

56

Chapter 8. TEMS Investigation Computer Diagnostics

8.1.3.

Diagnostics Report

You can obtain a plain-text summary of the diagnostics session by generating a diagnostics report. To produce the report, click the Generate Report button. A window named Diagnostics Report appears. You can save the report as a text file.

8.1.4.

Iterating the Diagnostics Procedure

After you have made adjustments to PC settings, you can run the Computer Diagnostics utility once more to see how the status of the machine has improved. Just click the Run Testcases button again to repeat the diagnostics procedure. If you install TEMS Investigation on a brand new PC, the Documents and Screen Saver diagnostics may be evaluated differently the first time around than on subsequent occasions (even if you do not change any PC settings). The reason is that on the first occasion, the relevant registry keys have not yet been initialized.

8.2.

Suitable PC Settings for TEMS Investigation

This section is a survey of the PC settings that are inspected by the TEMS Investigation Computer Diagnostics utility. It also includes a few further items. Further PC configuration, required for data service testing in specific circumstances, is described in section 10.6. General third-party software requirements are listed in section 5.1.3. Note: Please read this section carefully, since inappropriate PC settings may seriously impair the performance of TEMS Investigation, or even render certain functions unusable. If you have not purchased the data collection functionality, you can disregard most of this section.

NT12-6999 ver 1.0

57

TEMS Investigation 14.1 Getting Started Manual

8.2.1.

Administrator Rights

A number of user actions in TEMS Investigation require that the user have administrator rights on the PC: Running multiple concurrent data service sessions. In the course of such testing, TEMS Investigation must be able to modify Windows routing tables, which requires admin privileges. Use of the IP sniffer. See the Users Manual, section 20.16.3.7 and Information Elements and Events, section 8.8.

8.2.2.

Automatic Updating of Software

Software that uses an auto update function to receive automatic updates from a web site over a dial-up connection should be disabled.

8.2.3.

AutoPlay

Automatic launching of a PC application following device connect must be avoided. Therefore, make sure that for all connected devices used with TEMS Investigation, AutoPlay is disabled. How to disable AutoPlay is explained at support.microsoft.com/kb/967715 under the heading How to disable or enable all Autorun features in Windows 7 and other operating systems. The value that should be used to get a green light in the Computer Diagnostics tool is 0xFF, which means Disables AutoRun on all kinds of drives.

8.2.4.

Intel SpeedStep

If the PC is equipped with Intels SpeedStep technology regulating the processor speed, choose the setting Maximum Performance for all types of operation (Plugged in, Running on batteries).

8.2.5.

IR Port

The IR port on your PC may need to be disabled, since it may interfere with the ordinary COM ports. Please consult the user manual for your computer regarding how to disable the IR port.

58

Chapter 8. TEMS Investigation Computer Diagnostics

8.2.6.

My Documents Folder

TEMS Investigation places certain files under My Documents (or Documents) in a subfolder called TEMS Product Files. If your My Documents folder is located on a network drive, be sure to make the folder available offline before disconnecting from the network (for example, when going drive testing).

8.2.7.

Port-scanning Software

You should not have any software installed that periodically scans COM or USB ports, for instance Microsoft Outlook synchronization software such as Sony Ericsson PC Suite or Nokia PC Suite. The reason is that such software may cause difficult device connect problems in TEMS Investigation.

8.2.8.

RTP (UDP) Ports for Video Streaming

By default TEMS Investigation uses RTP (UDP) ports 50045007 for video streaming. If you intend to accept this default setting, you must make sure that the ports have not been reserved by some other application. You can specify a different port usage in a Streaming activity in a script; see the Users Manual, section 20.16.6.4.

8.2.9.

Security Products

Please note that hard disk encryption software, firewalls, virus scanners, and other security products may prevent multiple RAS sessions from being maintained concurrently, thus interfering with data service testing. Contact your IS/IT department for assistance in these matters. The realtime scanning feature of antivirus software is prone to generate considerable CPU load. If you find the overall CPU load excessive, it may be a good idea to try turning off the realtime scanning feature.

8.2.10.

Sleep Mode, Screen Savers, Energy Saving Features

You should make sure that the computer used for measurement and recording does not go into any kind of standby mode: Never put the PC in Sleep mode.

NT12-6999 ver 1.0

59

TEMS Investigation 14.1 Getting Started Manual

Disable the Windows screen saver: Windows 7, Windows Vista: Open the Control Panel and select Personalization Screen Saver. Under Screen saver, select (None). In the same dialog, make appropriate settings under Power management so that these features are never activated during measurement. Windows XP: Open the Control Panel and select Display Screen Saver. Under Screen saver, select (None). In the same dialog, make appropriate settings under Energy saving features... so that these features are never activated during measurement.

Disable any other screen savers.

(If the PC does go into standby, it may be necessary to unplug your data collection devices and plug them in again.)

8.2.11.

USB Legacy Support

USB Legacy Support must be turned off in BIOS. For information on how to do this, please consult the user manual for your computer.

8.2.12.

Windows Firewall

The built-in software firewall must be disabled in all Windows versions.

8.2.13.

Windows Media Player

Windows Media Player and other applications that attempt to synchronize to removable mass storage devices (such as mobile phones) must be disabled. They may otherwise interfere with data collection. For Windows XP, see also section 8.2.16.3 (deletion of registry keys).

8.2.14.

Windows 7 Specific Settings

8.2.14.1. IPv6
It is recommended to disable IPv6 for the modem of each connected device. If this is not done, the CPU load will rise appreciably, and dial-ups will take considerably longer to complete.

60

Chapter 8. TEMS Investigation Computer Diagnostics

Disabling of IPv6 needs to be done in the Windows registry; for instructions, see support.microsoft.com/kb/929852. To get a green light in the Computer Diagnostics tool, use the value 0xFFFFFFFF, which means Disable all IPv6 components, except the IPv6 loopback interface.

8.2.14.2. Power Management


Power management settings should be configured as described below. In Windows Explorer, right-click Computer and select Properties. Click Performance Information and Tools and then Adjust power settings. Click the down arrow button next to Show additional plans. Select High performance. Click Change plan settings, then click Change advanced power settings. Hard disk Turn off hard disk after: Never Sleep Sleep after: Never Power buttons and lid Lid close action: Do nothing Multimedia settings When sharing media: Prevent idling to sleep.

Advanced settings should be as follows:

8.2.14.3. User Access Control (UAC)


In Windows 7, there are four UAC levels. UAC should be set to the lowest level, Never notify. For running multiple concurrent data service sessions or logging IP data, as well as for the automatic software update function, this is strictly necessary.

8.2.14.4. Visual Effects


For performance reasons, it is strongly recommended that you disable the Windows Aero color scheme (making window frames translucent and producing other visual effects). To obtain the best possible TEMS Investigation performance, configure visual effects as follows (this will among other things turn Windows Aero off): Open the Control Panel and select System. Click Advanced system settings. The System Properties dialog opens.

NT12-6999 ver 1.0

61

TEMS Investigation 14.1 Getting Started Manual

Select the Advanced tab. In the Performance section, click the Settings button. Select the Visual Effects tab. The default setting here is Let Windows choose whats best for my computer. Change this to Adjust for best performance.

8.2.15.

Windows Vista Specific Settings

8.2.15.1. IPv6
It is recommended that you disable IPv6 for the modem of each connected device. The procedure is the same as in Windows 7; follow the instructions in section 8.2.14.1.

8.2.15.2. Power Management


Power management settings should be configured as described below. In Windows Explorer, right-click Computer and select Properties. Click Performance and then Adjust power settings. Select High performance. Click Change plan settings, then click Change advanced power settings. Sleep Sleep after: Never Power buttons and lid Lid close action: Do nothing Hard disk Turn off hard disk after: Never Multimedia settings When sharing media: Prevent idling to sleep.

Advanced settings should be as follows:

8.2.15.3. User Access Control (UAC)


UAC should be turned off. For running multiple concurrent data service sessions or logging IP data, as well as for the automatic software update function, this is strictly necessary.

62

Chapter 8. TEMS Investigation Computer Diagnostics

8.2.15.4. Visual Effects


For performance reasons, it is strongly recommended that you disable the Windows Aero color scheme. This is done in the same way as in Windows 7; follow the instructions in section 8.2.14.4.

8.2.16.

Windows XP Specific Settings

8.2.16.1. Power Management


Do the following: On the Control Panel, select Power Options. Go to the Power Schemes tab. Under Power schemes, select Always On.

8.2.16.2. Visual Effects


Visual effects and other bells and whistles in the Windows XP user interface should be disabled.

8.2.16.3. Windows Media Player


The following keys have to be deleted from the registry in order to disable Windows Media Player: \\localmachine\SOFTWARE\Microsoft\Windows Media Device Manager\Plugins\SP\MSPMSP \\localmachine\SOFTWARE\Microsoft\Windows Media Device Manager\Plugins\SP\WMDMCESP

NT12-6999 ver 1.0

63

TEMS Investigation 14.1 Getting Started Manual

9.

Installing the Call Generator

To perform audio quality measurements (AQM) with AQM modules, you need either a Call Generator or an MRU (Mobile Receiving Unit). See the Users Manual, chapter 36. How to install a Call Generator is described in the document Call Generator Installation Guide, which is included in the Call Generator sales package. This document also states PC hardware and operating system requirements posed by the Call Generator installation. How to use an MRU is explained in the MRU Users Manual accompanying that product.

64

Chapter 10. External Equipment

10.

External Equipment

This chapter gives an overview of the external devices that can interact with TEMS Investigation.

10.1.
10.1.1.

Connectable Equipment
User Terminals

10.1.1.1. UMTS
UMTS Devices Offered for Sale with TEMS Investigation 14.1 The following user terminals (supporting both GSM and WCDMA unless otherwise stated) can be delivered with TEMS Investigation 14.1: Sony Ericsson Xperia arc LT15a Sony Ericsson Xperia arc LT15i Sony Ericsson Xperia arc S LT18a Sony Ericsson Xperia arc S LT18i HTC Vivid (PH39100) Nokia C7-00 Samsung Galaxy S 4G (SGH-T959V) Samsung Infuse 4G (SCH-I997) Sierra Wireless AirCard 319U

Other Connectable UMTS Devices Sony Ericsson C702 Sony Ericsson C905 Sony Ericsson C905a

NT12-6999 ver 1.0

65

TEMS Investigation 14.1 Getting Started Manual

Sony Ericsson K600i Sony Ericsson K600i Sony Ericsson TM506 Sony Ericsson W760i Sony Ericsson W995 Sony Ericsson W995a Sony Ericsson W995 EDGE (GSM only) Sony Ericsson Xperia X10 Sony Ericsson Z750i LG CU320 LG CU500 LG U960 Nokia C5 Nokia 6120 Nokia 6121 Nokia 6720 Nokia N95 Nokia N96 EU Nokia N96 US Sharp 943SH Certified devices based on Qualcomm HSDPA chipsets, including: MSM6246/6260/6275/6280/6281 Certified devices based on Qualcomm HSPA chipsets (supporting both HSDPA and HSUPA), including: MSM6290/7200/7201/7201A/7225 Certified devices based on Qualcomm HSPA+ chipsets, such as MDM8200

If a Qualcomm chipset based device that you want to connect is not detected by TEMS Investigation, run the Manual UE Configuration utility to assist the application in recognizing the device. See the Users Manual, section 8.3.4 for details.

66

Chapter 10. External Equipment

Other Connectable GSM Phones Sony Ericsson K790a Sony Ericsson K790i Sony Ericsson W600i

10.1.1.2. LTE
A range of LG LTE USB modems A range of Samsung LTE USB modems Certified devices based on Qualcomm LTE or TD-LTE chipsets, including: MDM9200, MDM9600, MDM9800 Certified devices based on Sequans TD-LTE chipset SQN3010 Certified devices based on Altair TD-LTE chipset DC-E3100 Certified devices based on GCT LTE chipset Certified devices based on Hisilicon LTE chipset Balong 700

Some of these devices also have UMTS and/or EV-DO capability.

10.1.1.3. TD-SCDMA
Datang LC8130E Datang LC8143

10.1.1.4. CDMA
Certified devices based on Qualcomm 1x (cdma2000) chipsets: MSM5100 Certified devices based on Qualcomm EV-DO Rel. 0 chipsets: MSM6125/ 65x0 Certified devices based on Qualcomm EV-DO Rev. A chipsets, including: MSM6800/6800A, QSC6085 Certified devices based on Qualcomm EV-DO Rev. B chipsets, including: MSM7850 Certified devices based on Via CDMA/EV-DO chipset

If a Qualcomm chipset based device that you want to connect is not detected by TEMS Investigation, run the Manual UE Configuration utility to help the

NT12-6999 ver 1.0

67

TEMS Investigation 14.1 Getting Started Manual

application recognize the device. See the Users Manual, section 8.3.4 for details.

10.1.2.
W21 W25

Fixed Wireless Terminals

The following Ericsson Fixed Wireless Terminals can be connected:

10.1.3.

AQM Components

AQM modules (either stand-alone or mounted in an equipment case) can be connected. An ACU can be connected.

10.1.4.

Scanners

A wide range of scanner models are offered for sale with TEMS Investigation. Below a quick overview is given of scanner brands and their supported technologies.

10.1.4.1. GSM, WCDMA, LTE


SRUs WCDMA, GSM

Sony Ericsson Sony Ericsson phones with scanning capability (special option required)

PCTel Scanners PCTel PCT: WCDMA, GSM PCTel SeeGull LX: GSM PCTel SeeGull EX: LTE, WCDMA, GSM PCTel SeeGull EX mini: LTE PCTel SeeGull MX: LTE, WCDMA, GSM

68

Chapter 10. External Equipment

Notes on PCTel scanners: BSIC scanning is included in all GSM scanner licenses. GSM C/I scanning requires the purchase of an additional option. DRT Scanners DRT4301A+ LTE

Rohde & Schwarz Scanners R&S TSMW Universal Network Analyzer LTE technology option UMTS technology option

Transcom Scanners Transcom LTE

10.1.4.2. TD-SCDMA
PCTel SeeGull EX: TD-SCDMA, GSM PCTel SeeGull EX mini: TD-SCDMA

10.1.4.3. CDMA
PCTel SeeGull LX: 1x, EV-DO PCTel SeeGull MX: 1x, EV-DO PCTel SeeGull EX: 1x, EV-DO PCTel SeeGull EX mini: 1x, EV-DO

10.1.4.4. WiMAX
DRT4301A+

10.1.5.

GPS Units

TEMS Investigation supports the NMEA-0183 GPS protocol. Some other GPS units using a different protocol are also compatible with TEMS Investigation, including the GPS built into the supported PCTel scanners. This is the full list of recommended GPS units:

NT12-6999 ver 1.0

69

TEMS Investigation 14.1 Getting Started Manual

Garmin 10 Mobile Bluetooth (NMEA-0183) Garmin 12XL (NMEA-0183) Garmin 18 USB Garmin 18x USB Garmin 35 (NMEA-0183) Garmin 60 CSx USB GlobalSat BT-359 (NMEA-0183) GlobalSat BT-368 (NMEA-0183) GlobalSat BU-303 (NMEA-0183) GlobalSat BU-353 (NMEA-0183) Holux GPSlim 236 (NMEA-HS; Bluetooth or USB) Magnetti Marelli RoutePlanner NAV200 Nokia LD-3W Bluetooth (NMEA-0183) Sanav GM-44 (NMEA-0183) Sanav GM-158 (NMEA-0183)

For poor receiving conditions, a GPS unit with dead reckoning facilities is useful, such as Trimble Placer Gold Dead Reckoning Unit Plus.

10.2.

Capabilities of User Terminals Sold with TEMS Investigation

This section is restricted to user terminals that can be delivered with TEMS Investigation 14.1.

70

Chapter 10. External Equipment

SE Xperia arc S LT18a

SE Xperia arc S LT18i

WCDMA 800 (Band VI) WCDMA 850 (Band V) WCDMA 900 (Band VIII) WCDMA 1700 (Band X) WCDMA 1900 (Band II) WCDMA 2100 (Band I) WCDMA 2100 AWS (Band IV) GSM 850 GSM 900 GSM 1800 GSM 1900 HSDPA Category HSUPA Category GPRS Class EDGE Class Control functionality AQM capable
1

Nokia C7-00

Device/Feature

Samsung Infuse 4G 14 6 10 10 A

Samsung Gal. S 4G

8 6 10 10

8 6 10 10

10 6 12 12 A

10 6 12 12 A

14 6 12 12

9 5 32 32 B

14 6 10 10 A

24 6 12 10

(CG/MRU)2

AQM capable (ACU TerraTec) TEMS Pocket 1. A = Advanced; B = Basic. See the Users Manual, chapter 21. 2. Capable devices are listed in section 10.3.1.

NT12-6999 ver 1.0

Sierra Wirel. AC319U 71

SE Xperia arc LT15a

SE Xperia arc LT15i

HTC Vivid

TEMS Investigation 14.1 Getting Started Manual

10.3.
10.3.1.

Supported AQM Capable Devices


AQM with Call Generator/MRU

10.3.1.1. UMTS
Sony Ericsson W995, W995a, W995 EDGE Sony Ericsson Z750i Sony Ericsson K790a, K790i, K800i LG CU500

10.3.1.2. CDMA
Kyocera KX5 Samsung SPH-M320, SPH-M330

10.3.2.

AQM with ACU (TerraTec)

Both PESQ and POLQA can be obtained with all of the listed devices.

10.3.2.1. UMTS
Sony Ericsson Xperia arc LT15a, LT15i Sony Ericsson Xperia arc S LT18a, LT18i Sony Ericsson W995, W995a Sony Ericsson W995 EDGE (GSM only) Nokia C7-00

10.3.2.2. CDMA
Huawei C8600

72

Chapter 10. External Equipment

10.4.

Basic Configuration of User Terminals

Sony Ericsson W995 Models Sony Ericsson W995 TEMS phones have a special setting USB Speed, found under Menu Settings Connectivity tab USB. The choices are High Speed (upper limit: 480 Mbit/s) and Full Speed (upper limit: 12 Mbit/s). Select High Speed when running HSDPA in order to achieve the best possible throughput. (This is not applicable to W995 EDGE, for obvious reasons.) Select Full Speed when the phone is using GSM 850 or 900 in an area where it is forced to transmit at maximum power. If High Speed is used in such situations, the GSM transmissions will interfere with the USB connection, so that logfiles may be lost and the USB connection may possibly break down, necessitating a reboot of both phone and PC.

Before changing the setting, make sure the USB cable is disconnected from the phone. After you make the change, the phone will reboot automatically. This takes some time (about 15 s). Sony Ericsson W995 Models with Firmware Version R1F Or Later You need to execute the autorun application (Startup.exe) supplied with the phone. However, you must not install everything that comes with this application; rather, you must limit the installation to the drivers: In the interface of the autorun application, click the Advanced button. Select the Drivers only option.

Make sure AutoPlay in Windows is not disabled when you connect the phone to the PC. (On the other hand, AutoPlay should be disabled when running TEMS Investigation; see section 8.2.3.) Also turn off searching for drivers through Windows Update, or abort the search manually (otherwise, this will take a very long time). Sony Ericsson Android Phones (Qualcomm Chipset Based) You need to activate USB debugging so that all relevant ports become visible: Press the Menu button, then choose Settings Applications Development, and make sure USB debugging is enabled.

NT12-6999 ver 1.0

73

TEMS Investigation 14.1 Getting Started Manual

For Xperia arc and X10, no APN must be set in the phone. Press the Menu button, then choose Settings Wireless & networks Mobile networks Access Point Names, and make sure nothing is set. (This procedure is not needed on the Xperia arc S.)

Hisilicon Chipset Based Devices A software utility called Hisilicon UE Agent must be running on the PC to be able to activate a Hisilicon chipset based device in TEMS Investigation. The utility is included on the driver CD; see section 7.1.3. Nokia Phones The Net Monitor function in Nokia phones (if present) must be turned off. Qualcomm Chipset Based Devices Some commercial Qualcomm chipset derived user terminals may not have diagnostics reporting enabled by default, and Ascom is not at liberty to distribute information on how to enable this function. Customers desiring to use such devices with TEMS Investigation therefore need to contact the relevant supplier or operator in each case. Sequans Devices The driver delivered by Sequans along with their device also installs a daemon service sequansd (to C:\Program Files\Sequans Communications) which must be running in order to enable communication between device and PC. The required version of the Sequans driver package is sqn_setup_2.3.1.0-8786.exe. TEMS Investigation manages the daemon service automatically. However, as a TEMS Investigation user you need to manually point out the LTE frequency band and EARFCN on which the device should start searching. This is done by editing an XML file sequansd.xml which resides in the same directory as the daemon (see path above). The XML file is reproduced in full below; the band and frequency are specified in the <script> section: <?xml version="1.0" ?> <sequansd> <server> <ip>127.0.0.1</ip> <port>7771</port> <host></host>

74

Chapter 10. External Equipment

<maxClients>5</maxClients> </server> <!-- Define the log file name --> <debug> <logfilter>finer:*</logfilter> <logfile>SequansdLog.txt</logfile> </debug> <ffh> <!-- Windows --> <repository>Firmwares</repository> </ffh> <!-- Startup script --> <script> <cli>setUsimmode 0</cli> <cli>clearScanConfig</cli> <cli>addScanFreq 40 39150</cli> </script> </sequansd> If you edit the sequansd.xml file while the daemon service is running, you must restart the service. This is most easily done from the Windows Task Manager: Go to the Services tab and locate the sequansd service. Right-click sequansd and select Stop Service. Right-click sequansd once more and select Start Service.

10.5.

Connecting External Antennas to Phones

An external monopole antenna is connected to a phone by means of a coaxial cable (and possibly an adapter) supplied with the phone. Phone-specific details are as follows: Sony Ericsson W995*, Z750i When ordering an external antenna with one of these phones, the phone is delivered with the antenna adapter already mounted. Just connect the antenna to the adapter.

NT12-6999 ver 1.0

75

TEMS Investigation 14.1 Getting Started Manual

A Sony Ericsson phone with an external antenna mounted cannot use its internal antenna. Nokia N96 Press the antenna adapter into the hole provided for it, then connect the antenna to the adapter.

10.6.
10.6.1.

Configuring Devices for Data Services


Setting Up the Device APN (UMTS)

To run packet-switched data services in UMTS, the Access Point Name (APN) must be configured for the device. For most devices, this can be done from within TEMS Investigation by defining a Network Connect configuration set; see the Users Manual, section 20.16.3.1. Some exceptions to this rule are covered below. Nokia Phones For Nokia phones you need to set the APN directly in the phones user interface. For example, on the Nokia N96, navigate to Tools Settings Connection Destinations. Datang Phones The APN configuration is accomplished when you run the Datang PostInstall utility as described in section 7.1.2. If you want to change the APN later on, it is most convenient to run DatangPostInstall.exe again (with argument). Devices Using an NDIS Connection A device that is going to use an NDIS connection must have an APN preconfigured. If an APN is not already present on the device on delivery, you need to enter one using a software application delivered with the device. Please consult documentation from the vendor for specifics.

76

Chapter 10. External Equipment

10.7.
10.7.1.

Scanners
Anritsu

Anritsu ML8720: Basic Configuration The serial port baud rate must be set to 115200 in the scanner. Proceed as follows: From the scanner main menu, select System Configuration, then select Interface and Behavior. Set the COM1 protocol to Direct. Set the COM1 baud rate to 115200. Set COM1 stop bit(s) to 1. Set COM1 data length to 8. Set COM1 parity to None. From the side menu (operated with buttons on the side of the scanner), select OK.

Anritsu ML8720: Cable A null modem cable must be used to connect the Anritsu ML8720 to the PC.

10.7.2.

PCTel

Any PCTel scanner can be mounted into a TC-1520, TC-1520B, TC-1520C, TC-1520D, or TC-1520E equipment case (the mounting kit accompanies the case). Any PCTel scanner can be carried in a TEMS Indoor Backpack (see section 3.4), which includes a battery pack. A battery pack is also obtainable as a separate add-on. The scanner is equipped with an SMA connector for the GPS antenna; besides, an SMASMB adapter is supplied with the scanner.

10.7.2.1. PCTel SeeGull LX


All PCTel SeeGull LX scanners have an RF antenna included in the package. WCDMA scanner packages furthermore contain a GPS antenna.

NT12-6999 ver 1.0

77

TEMS Investigation 14.1 Getting Started Manual

MM2 scanners are equipped with a USB power cable. Dual- and single-band scanners are powered through a serial cable. The following functions can be added as options for GSM-capable scanners: GSM C/I measurement GSM System Information (BCCH) decoding

10.7.2.2. PCTel SeeGull EX


The PCTel SeeGull EX scanner has two RF antennas included in the package, as well as a USB cable, a power cable, and a GPS antenna. The EX Mini has only one RF component and hence only one RF antenna. The following functions can be added as options: GSM C/I measurement (for GSM-capable scanners) GSM and WCDMA System Information (Layer 3) decoding Spectrum analysis

10.7.2.3. PCTel SeeGull MX


The PCTel SeeGull MX scanner has two RF antennas included in the package, as well as a USB cable, a power cable, and a GPS antenna. The following functions can be added as options: Spectrum analysis Enhanced Power scanning

10.7.2.4. PCTel PCT


The PCTel PCT scanner has one or two RF antennas included in the package, as well as a USB cable and a power cable. The following function can be added as options: Spectrum analysis

10.7.2.5. Technical Notes on PCTel Scanners 10.7.2.5.1. Reference Point for Signal Level Measurement
This section applies to all supported PCTel SeeGull LX and EX scanners.

78

Chapter 10. External Equipment

The signal level reported by the scanner is that measured at the scanners antenna connector. No adjustment is made in the scanner to compensate for antenna or cable loss.

10.7.2.5.2. Antenna Cable Attenuation


PCTel OP216 Antenna This is a magnetic mount antenna with +4 dBi gain. It covers the frequency range 1700 to 2700 MHz. The antenna is delivered with a 12 ft (3.66 m) coaxial cable called Pro Flex Plus 195. In the table below is shown the total cable attenuation at various frequencies: Frequency (MHz) 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 Smarteq Minimag Antenna This is a magnetic mount antenna with 0 dBd gain. It covers the frequencies 890 to 960 MHz and 1710 to 2170 MHz. The antenna is delivered with a Smarteq RG-174 cable whose loss at 2100 MHz is specified at 1.47 dB per meter cable maximum. The total length Total Attenuation of Cable (dB) 2.15 2.22 2.22 2.33 2.50 2.50 2.55 2.78 2.82 2.82 2.90

NT12-6999 ver 1.0

79

TEMS Investigation 14.1 Getting Started Manual

of the cable is 2.6 m. In the following table is shown the total cable attenuation at various frequencies: Frequency (MHz) 900 1800 1900 2000 2100 Total Attenuation of Cable (dB) 2.34 3.46 3.61 3.70 3.82

10.7.3.

Andrew i.Scan

The Andrew i.Scan package contains a GPS antenna (Mighty Mouse II), a data cable, an AC power cable, a cigarette lighter power cord and a serial configuration cable. The single RF antenna must be purchased separately. Multiple Andrew i.Scan units can be connected in a daisy chain.

10.7.4.

Rohde & Schwarz TSMW

The Rohde & Schwarz TSMW package contains two antennas (820960 MHz, 17002170 MHz) with an SMA-to-N adapter, a GPS antenna, an AC power cable, a cigarette lighter power cord, a universal AC power adapter, and a data cable.

10.7.5.

DRT

The DRT4301A+ scanner package includes: LTE/WiMAX antenna suitable for the selected technology and frequency band(s) GPS antenna Power cable with vehicle power termination Universal AC power adapter 100Base-T crossover RJ-45 male data cable

80

Chapter 11. PC and Device Configuration for Ericsson Fixed Wireless Terminal

11.

PC and Device Configuration for Ericsson Fixed Wireless Terminal

Ericsson Fixed Wireless Terminals (FWTs) are routers offering wireless access to broadband Internet and telephony. The FWT constitutes a gateway to a network. Regarding FWT operation in general, please consult the documentation delivered with the product.

11.1.

PC Configuration

If an FWT is to be used with TEMS Investigation, the following must be observed: The PC must not be connected to any other network. (The default gateway must be unambiguously defined in the PC OS.) The default IP address of the FWT is 192.168.1.1. It is possible to change this address to any value; however, TEMS Investigation requires that the IP address fall within the private address space ( IETF RFC 1918). If a firewall or other security product is installed, you must make sure that port 1895 is open, since the TEMS service uses this port.

11.2.

FWT Configuration

The FWT itself must be configured as follows: Connect the PC and FWT with a LAN cable. Configure the network interface on the PC with either a static IP address in the range 192.168.1.0/241 or DHCP. Using Telnet2, log in to the FWT (192.168.1.1)1 as root. The root password will be different in each custom configuration. Please contact your supplier or operator for assistance.

NT12-6999 ver 1.0

81

TEMS Investigation 14.1 Getting Started Manual

Run the following commands: # cf set tems.enabled true # cf commit The TEMS service will now always be running on the FWT whenever it is turned on. There is no need to restart the TEMS service after the FWT has been rebooted. To disable the TEMS service, run these commands: # cf set tems.enabled false # cf commit

1. This is the default network on the FWT LAN, though it is possible that the FWT has been configured differently. 2. In Windows 7/Vista, the Telnet client is by default not activated. To activate it, do as follows: Open the Control Panel and navigate to Programs and Features. Click Turn Windows features on or off. In the feature list that appears, check Telnet Client.

82

Chapter 12. PC and Device Configuration for DRT Scanner

12.

PC and Device Configuration for DRT Scanner

This chapter applies to all currently supported DRT scanners (models listed in section 10.1.4). A DRT scanner can either be connected directly to the PC by means of a cable, or it can be accessed over a local area network. The instructions that follow tell how to configure the PC in each case. See also the Users Manual, section 8.1.3.

12.1.

Direct Connection

The DRT scanner is shipped configured for a direct connection and is assigned the static IP address 192.168.5.2. The PCs Ethernet adapter must likewise have its TCP/IP address configured as static and equal to 192.168.5.1. Follow these steps: 1. Access the Windows user interface showing your network connections: (Windows 7) Start Control Panel Network and Sharing Center Change Adapter Settings (Windows Vista) Start Settings Network Connections (Windows XP) Start Connect To Show All Connections.

2. Double-click Local Area Connection. 3. Click the Properties button. (Not applicable for Windows 7.) 4. In the box below This connection uses the following items:, select: (Windows 7/Vista) Internet Protocol Version 4 (TCP/IPv4) (Windows XP) Internet Protocol (TCP/IP).

5. Then click the Properties button.

NT12-6999 ver 1.0

83

TEMS Investigation 14.1 Getting Started Manual

6. Select Use the following IP address. Under IP address, enter 192.168.5.1. Under Subnet mask, enter 255.255.255.0. Then click OK. 7. Connect the scanner to the PCs Ethernet port with a crossover 100Base-T cable.

12.2.

Local Area Network Connection

For this setup, the scanner must be reconfigured to acquire a dynamic IP address from the network. Follow these steps: 1. Assuming the scanning receiver and the laptop are both configured for static IP addressing, and the scanner is connected to the remote PC via a crossover 100Base-T cable, connect to the scanner with a web browser by entering the URL http://drt4301snaaaa, where aaaa is the serial number of the device. 2. On the web page that appears, under Wired Ethernet configuration, clear the Static IP Address field. 3. Click Save Changes. 4. Access the Windows user interface showing your network connections: (Windows 7) Start Control Panel Network and Sharing Center Change Adapter Settings (Windows Vista) Start Settings Network Connections (Windows XP) Start Connect To Show All Connections.

5. Double-click Local Area Connection and click the Properties button. 6. In the box below This connection uses the following items:, select: (Windows 7/Vista) Internet Protocol Version 4 (TCP/IPv4) (Windows XP) Internet Protocol (TCP/IP).

7. Select Obtain an IP address automatically. 8. Select Obtain DNS server address automatically. Then click OK. 9. Connect the PC and the scanner to available Ethernet ports on the same subnet of the LAN with normal (non-crossover) 100Base-T cables. If the remote location is not on the same subnet, then a VPN connection may be used to create an extended virtual subnet that can host the scanner as if it were on a local subnet.

84

Chapter 12. PC and Device Configuration for DRT Scanner

12.3.

Verifying the Configuration

Here is how to confirm and troubleshoot the connection to the scanner. Before you begin, make sure your firewall is disabled; see sections 8.2.9 and 8.2.12. 1. Connect the Ethernet cable or cables as described in sections 12.1 and 12.2. 2. Open a Windows command prompt (select Start Run, enter cmd, and press Enter). 3. Ping the unit by typing the command ping drt4301snaaaa, where aaaa is the serial number of the device, and observe if responses are received. 4. If no response occurs, you may use Wireshark to capture the Ethernet traffic and determine the units current IP address. Enter the filter term nbns.flags == 0x2910 to isolate the Netbios Naming Service registration messages sent out by the scanner. The IP address will be included in the message from the scanner.

12.4.

Scanner Antenna Connection

On DRT scanners that have two RF inputs, the RF antenna must be connected to the RF IN B port.

NT12-6999 ver 1.0

85

TEMS Investigation 14.1 Getting Started Manual

13.

PC and Device Configuration for Andrew i.Scan

The Andrew i.Scan can be equipped with one or two modules, which are available in many frequency band configurations. Bands and technologies are independent.

13.1.

Prerequisites

Terminal emulator application installed on the PC (for example Putty, which can be downloaded free of charge from www.putty.org). Serial cable with 9-pin male connector (plugged into the Andrew scanner via the accompanying serial port adapter cable) and 9-pin female connector (plugged into the PC). Network cable with an RJ-45 connector at either end. Note that if the cable connects the PC and scanner directly, i.e. if there is no intervening router or switch, then the cable should be cross-connected.

13.2.
13.2.1.

Instruction
Setting Up the Serial Connection

Start your terminal emulator program.

Configure the serial line between scanner and PC as shown in the screenshot below, taken from Putty (Configure the serial line section):

86

Chapter 13. PC and Device Configuration for Andrew i.Scan

(The COM port should of course be replaced by the one to which the scanner is connected.) In Putty you establish the connection between scanner and PC by pressing the Return key. If you are using a different terminal emulator, perform the corresponding operation.

13.2.2.

Configuring the Andrew Scanner

Once the connection has been established between scanner and PC, the terminal emulator should display information looking something like this (Putty again used as example): Flash data ---------Mainframe name = Andrew Corporation IP address = 192.168.003.253 Subnet mask = 255.255.255.000 Gateway address = 000.000.000.000 Interface type = 1 Enter a number to change an item -------------------------------0 = done 1 = mainframe name 2 = IP address 3 = subnet mask

NT12-6999 ver 1.0

87

TEMS Investigation 14.1 Getting Started Manual

4 = gateway address 5 = interface type (1 = Invex, 2 = OEM) The one thing that has to be changed is the interface type (5). Press 5 and Return, then change the interface type to 2 (OEM). Save by pressing 0 and Return, then y. Flash data ---------Mainframe name = Andrew Corporation IP address = 192.168.003.253 Subnet mask = 255.255.255.000 Gateway address = 000.000.000.000 Interface type = 2 Enter a number to change an item -------------------------------0 = done 1 = mainframe name 2 = IP address 3 = subnet mask 4 = gateway address 5 = interface type (1 = Invex, 2 = OEM) > OK to update Flash (y/n)? y Note: Do not change the mainframe name; TEMS Investigation uses that name to autodetect the scanner.

13.2.3.

Manual Input of IP Address If Autodetect Fails

If autodetection does not work properly, you can set the IP address manually in this file: <TEMS Investigation install dir>\Application\Settings\ TEMS.Equipment.Andrew.Settings.AndrewSettings.config With full autodetect and scanner response:

88

Chapter 13. PC and Device Configuration for Andrew i.Scan

<setting name="UseDetector" serializeAs="String"> <value> true </value> </setting> <setting name="ScannerIPs" serializeAs="String"> <value></value> </setting> With semi-autodetect and no scanner response: (In this example two scanners are identified. If UseDetector is false, the setting ScannerIPs will be checked for scanner IP addresses. In this setting, multiple IP addresses are separated by semicolons.) <setting name="UseDetector" serializeAs="String"> <value>false</value> </setting> <setting name="ScannerIPs" serializeAs="String"> <value>192.168.1.253;192.168.1.250</value> </setting>

13.2.4.

Configuring the PC Network Adapter (for Direct ScannerPC Connection)

If the Andrew scanner is connected directly to the PC, a fixed IP address should be selected at the PC end. Configure the local area connection as shown in the following screenshot, selecting the option Use the following IP address. Note that the IP address selected here (192.168.3.252) is adjacent to the scanners IP address in the example in section 13.2.2 (192.168.3.253). This is not a requirement, but the two addresses do have to be on the same subnet (first nine digits identical).

NT12-6999 ver 1.0

89

TEMS Investigation 14.1 Getting Started Manual

13.2.5.

Connecting the Scanner

Connect the network cable to the A or B slot on the scanner. Connect the other end of the cable to the PC either directly or via a switch or router. Look for a network icon in the bottom right-hand corner of the PC screen (if it is configured to show up). When you have a connection, you are done. Now start TEMS Investigation. The Andrew scanner should autodetect in a matter of seconds once TEMS Investigation is up and running.

90

Chapter 14. PC and Device Configuration for R&S TSMW Scanner

14.

PC and Device Configuration for R&S TSMW Scanner

The Rohde & Schwarz TSMW scanner is connected directly to the PC by means of a cable. The instructions that follow tell how to configure the PC for that connection. See also the Users Manual, section 8.1.3. The R&S TSMW scanner is shipped configured for a direct connection and is assigned the static IP address 192.168.0.2. The PCs Ethernet adapter must likewise have its TCP/IP address configured as static and equal to 192.168.0.1. Follow these steps: 1. Connect the scanner to the PCs Ethernet port with a crossover 100Base-T cable. 2. Access the Windows user interface showing your network connections: (Windows 7) Start Control Panel Network and Sharing Center Change Adapter Settings (Windows Vista) Start Settings Network Connections (Windows XP) Start Connect To Show All Connections.

3. Double-click Local Area Connection. 4. Click the Properties button. (Not applicable for Windows 7.) 5. In the box below This connection uses the following items:, select: (Windows 7/Vista) Internet Protocol Version 4 (TCP/IPv4) (Windows XP) Internet Protocol (TCP/IP)

6. Then click the Properties button. 7. Select Use the following IP address. Under IP address, enter 192.168.0.1. Under Subnet mask, enter 255.255.255.0.

NT12-6999 ver 1.0

91

TEMS Investigation 14.1 Getting Started Manual

8. Click the Advanced... button and disable NetBIOS over TCP/IP under the WINS tab. Click OK. 9. After booting the TSMW, double-check if the connection is successfully established by pinging the scanner. In a Command Prompt, type ping 192.168.0.2.

92

Chapter 15. PC and Device Configuration for DRT Transmitter

15.

PC and Device Configuration for DRT Transmitter

TEMS Investigation with connected external devices can be used in conjunction with a DRT test transmitter which the devices can camp on. The transmitter then needs some configuration, the steps of which are detailed here for easy reference. The DRT transmitter is controlled from a PC, to which it can be connected directly by means of a cable, over a local area network, or via Wi-Fi. The instructions that follow tell how to configure the transmitter and the PC in each case. This chapter applies to the DRT4302A+ transmitter model.

15.1.

Setting Up the Transmitter

Before you begin, you need to install the Nome application, which functions as the transmitters user interface. Along with it, another application Yukon4k is installed which is used for configuring the transmitters network connection. 1. After installing the above software, start Yukon4k. This application will find the DRT transmitter automatically and present its name as shown in the screenshot below.

NT12-6999 ver 1.0

93

TEMS Investigation 14.1 Getting Started Manual

2. On the IP Address tab you can set IP addresses for Ethernet and Wi-Fi. The adapter for Ethernet is eth0 and by default uses the IP address 192.168.1.100. The Wi-Fi adapter is called eth1 and uses the default IP address 192.168.2.100. 3. If you are going to connect to the transmitter via Ethernet, then for Adapter = eth0 you need to select Obtain an IP Address automatically and click the Set Unit IP Configuration button. Compare section 15.3. 4. To be able to access the transmitter over Wi-Fi, enter appropriate settings on the WiFi Settings tab: ESSID: Wi-Fi network name. Channel: Select an unused channel in the range 1 ... 10. Mode: Always Ad-Hoc. The transmitters Wi-Fi (802.11b/g) interface operates in an ad-hoc (peer-to-peer) configuration; the interface currently does not support the Wi-Fi infrastructure mode of operation. Control is determined when the unit is powered on. Note that any device that is going to receive signals from the DRT transmitter must support the ad-hoc mode of operation. Security: None or WEP. Key: If WEP is used, enter the WEP key here.

When you are done entering the parameters, click the Set Wireless Configuration button.

94

Chapter 15. PC and Device Configuration for DRT Transmitter

5. If you want to change between Ethernet and Wi-Fi connection mode, you must reboot the transmitter. See section 15.1.1 below.

15.1.1.

Changing between Ethernet and Wi-Fi Network Configuration Modes

On power-up or boot, the transmitter checks to see if there is an Ethernet cable connected to the DATA connector. If an Ethernet cable is present, the unit is configured to use that cable for control; if not, it selects Wi-Fi for communications. To switch between these modes, it is necessary to turn off power to the transmitter and plug in or plug out the Ethernet cable as appropriate. Then power on the unit again, and the networking mode will be selected as just described.

15.2.

Configuring the PC for Direct Connection

The DRT transmitter is shipped configured for a direct connection, with the static IP address 192.168.1.100 assigned to its Ethernet (eth0) adapter. The PCs Ethernet adapter must likewise have its TCP/IP address configured as static and in the range 192.168.1.nnn, where nnn is any number between 1 and 255 except 100. Follow these steps:

NT12-6999 ver 1.0

95

TEMS Investigation 14.1 Getting Started Manual

1. Access the Windows user interface showing your network connections: (Windows 7) Start Control Panel Network and Sharing Center Change Adapter Settings (Windows Vista) Start Settings Network Connections (Windows XP) Start Connect To Show All Connections.

2. Double-click Local Area Connection. 3. Click the Properties button. (Not applicable for Windows 7.) 4. In the box below This connection uses the following items:, select: (Windows 7/Vista) Internet Protocol Version 4 (TCP/IPv4) (Windows XP) Internet Protocol (TCP/IP).

5. Then click the Properties button. 6. Select Use the following IP address. Under IP address, enter 192.168.1.100. Under Subnet mask, enter 255.255.255.0. Then click OK. 7. Connect the transmitter to the PCs Ethernet port with a crossover 100Base-T cable.

15.3.

Configuring the PC for LAN Connection

As explained in section 15.1, step 3, the Ethernet adapter of the DRT transmitter needs to be set to obtain an IP address automatically. You need to change this setting on the PC as well. Follow these steps: 1. Access the Windows user interface showing your network connections: (Windows 7) Start Control Panel Network and Sharing Center Change Adapter Settings (Windows Vista) Start Settings Network Connections (Windows XP) Start Connect To Show All Connections.

2. Double-click Local Area Connection and click the Properties button. 3. In the box below This connection uses the following items:, select: (Windows 7/Vista) Internet Protocol Version 4 (TCP/IPv4) (Windows XP) Internet Protocol (TCP/IP).

96

Chapter 15. PC and Device Configuration for DRT Transmitter

4. Select Obtain an IP address automatically. 5. Select Obtain DNS server address automatically. Then click OK. 6. Connect the PC and the transmitter to available Ethernet ports on the same subnet of the LAN with normal (non-crossover) 100Base-T cables. If the remote location is not on the same subnet, then a VPN connection may be used to create an extended virtual subnet that can host the transmitter as if it were on a local subnet.

15.4.

Verifying the Configuration

Here is how to confirm and troubleshoot the connection to the transmitter. Before you begin, make sure your firewall is disabled; see sections 8.2.9 and 8.2.12. 1. Connect the Ethernet cable or cables as described in sections 12.2 and 12.3. 2. Open a Windows command prompt (select Start Run, enter cmd, and press Enter). 3. Ping the unit by typing the command ping drt4302snaaaa, where aaaa is the serial number of the device, and observe if responses are received. 4. If no response occurs, you may use Wireshark to capture the Ethernet traffic and determine the units current IP address. Enter the filter term nbns.flags == 0x2910 to isolate the Netbios Naming Service registration messages sent out by the transmitter. The IP address will be included in the message from the transmitter.

15.5.

Configuring Transmitter Cell Information

There are two ways to connect to the DRT transmitter and set up its cell information: through Nome or through a web interface.

15.5.1.

Configuring the Transmitter Using Nome

1. Start Nome and wait for the application to find the DRT transmitter. When found, it appears in the list box.

NT12-6999 ver 1.0

97

TEMS Investigation 14.1 Getting Started Manual

2. Select the DRT transmitter in the list, and click Connect. A new screen appears where you configure transmitter settings.

D E

Technology = GSM

Technology = WCDMA

3. In the top section highlighted in the screenshot above, you can configure the following (letters refer to labels added in red):

98

Chapter 15. PC and Device Configuration for DRT Transmitter

A: Cellular technology, GSM or WCDMA. B: Modulation On or Off. Mod On means that the transmitter mimics a GSM or WCDMA downlink channel. Mod Off means that a CW signal is transmitted. C: RF Off = transmission turned off; RF On = transmission turned on. D: Output power, configurable in the range 20 ... +21 dBm.

4. Protocol Specific section (E): Here you set what band and (U)ARFCN to use, along with other cell parameters.

15.5.2.

Configuring the Transmitter Using Web Interface

The web browser used to access the DRT transmitter interface must support Ajax, for example: Internet Explorer 8 or later, Firefox 3.0.17, Firefox 3.6.3. 1. Connect to the transmitter with a web browser by entering the URL http://drt4302snaaaa, where aaaa is the serial number of the device. Alternatively, you can also enter the IP address for the transmitter: by default http://192.168.1.100 for Ethernet or http://192.168.2.100 for Wi-Fi. 2. The web browser interface looks somewhat different from the Nome application. Click the Tx Configuration link to set transmission parameters (left-hand screenshot below); compare section 15.5.1, step 3. Clicking the Unit Status link displays device status information, as shown in the screenshot on the right.

NT12-6999 ver 1.0

99

TEMS Investigation 14.1 Getting Started Manual

100

Chapter 16. Preparations for AQM with Audio Capturing Unit (ACU)

16.

Preparations for AQM with Audio Capturing Unit (ACU)

This chapter describes necessary preparations for conducting audio quality measurement using an Audio Capturing Unit (ACU) in the form of a TerraTec DMX 6Fire USB box. Regarding this AQM solution in general, refer to the Users Manual, chapter 37.

16.1.

Installing Drivers for ACU

See section 7.8 of this document.

16.2.

Adjusting ACU Physical Controls

On the rear panel of the ACU, turn all five knobs (HEADPHONE, GAIN 1, GAIN 2, PHONO IN, MONITOR) to minimum.

The GAIN 1 and MONITOR knobs must not be adjusted. Doing so will compromise the PESQ score.

NT12-6999 ver 1.0

101

TEMS Investigation 14.1 Getting Started Manual

16.3.

Connecting Equipment to the ACU

1. To each phone, connect the proper audio cable (these are phone model specific). 2. Connect an audio adaptor (generic for all phone models) to the other end of each audio cable. 3. For each phone, connect the audio adaptor RCA plugs (white and red) to the ACU as indicated below. Note that the channels on the TerraTec box must always be paired as shown here (12 and 34), and not in any other manner. Phone No. First pair of phones (#1, #2) 1 RCA Plug White Red 2 White Red Second pair of phones (#3, #4) 3 White Red 4 White Red Connect To LINE IN 1 LINE OUT 1 LINE IN 2 LINE OUT 2 LINE IN 3 LINE OUT 3 LINE IN 4 LINE OUT 4

4. Connect each phone to the USB hub included in the ACU package. 5. Connect the USB cable between the ACUs USB port and the PC. 6. Connect the ACU power cable to the POWER inlet and to a power source.

102

Chapter 16. Preparations for AQM with Audio Capturing Unit (ACU)

16.4.

Settings in the TerraTec PC User Interface

A user interface, mimicking a panel of physical controls, is installed along with the TerraTec driver. It is loaded into the Windows system tray by default and represented by this icon:

The user interface has three tabs. The tabs you need to edit are MIXER and OUTPUT & SETTINGS. Throughout the user interface, text labels on buttons are color-coded thus: Yellow color means enabled. White color means disabled.

MIXER Tab

Make sure the settings are as follows: LINK disabled in all columns. INPUT 1/2 column: MONO disabled. INPUT 3/4 column: LINE enabled, PHONO disabled. DIGITAL IN column: (The OPT/COAX setting does not matter.) WAVEPLAY 1/2 column: 1/2 enabled in bottom row. WAVEPLAY 3/4 column: 3/4 enabled in bottom row. WAVEPLAY 5/6 column: All buttons disabled in bottom row (these outputs are not used). DIGITAL PLAY column: All buttons disabled in bottom row.

NT12-6999 ver 1.0

103

TEMS Investigation 14.1 Getting Started Manual

On this tab, you also need to adjust the WAVEPLAY volume sliders in order to achieve suitable volume levels. Controlling the volume is essential in order to obtain correct AQM scores. Note that if the two phones in a pair are different models, each requires a different volume setting, as tabulated below. The LINK button must then be disabled for that pair of sliders; otherwise the sliders will be coupled and always set identically.

In this example, the devices used are: Phone 1: Sony Ericsson W995 Phone 2: Sony Ericsson Xperia arc Phone 3: Nokia C7 Phone 4: Nokia C7

2 3 Phone no.

The appropriate settings are phone-specific:


Phone Model Sony Ericsson W995 Sony Ericsson Xperia arc Sony Ericsson Xperia arc S Nokia C7 Huawei C8600 WAVEPLAY Volume Setting 20 dB 35 dB 25 dB 30 dB 27 dB

104

Chapter 16. Preparations for AQM with Audio Capturing Unit (ACU)

OUTPUT & SETTINGS Tab

On this tab, required settings are as follows: All volume sliders set to 0 dB. LINK disabled in all columns. MASTER column: MUTE disabled. DEVICE SETTINGS section: MULTIDEVICE enabled.

16.5.

Configuration of Windows Settings

Volume settings must also be kept fixed in Windows for each of the devices representing the TerraTec box there. (The instructions below refer to Windows 7 user interface designations.) Open the Control Panel and select Sound. On the Playback tab, under Select a playback device ..., three DMX 6Fire Waveplay devices appear (with channel suffixes 1/2, 3/4, 5/6). For devices DMX 6Fire Waveplay 1/2 and DMX 6Fire Waveplay 3/4, do as follows: Select the device. Click the Properties button. The default settings should be kept on all tabs: On the Levels tab, the Speakers volume slider should be set to maximum. On the Enhancements tab, the box Disable all enhancements should be checked.

NT12-6999 ver 1.0

105

TEMS Investigation 14.1 Getting Started Manual

The Advanced tab should look like this:

To prevent interruptions from any other sound sources (e.g. spoken messages from TEMS Investigation), neither DMX 6Fire Waveplay 1/2 nor DMX 6Fire Waveplay 3/4 should be selected as default playback device. The 5/6 device, on the other hand, can be selected since it is not used.

16.6.

Calibration of Phones

To control volume levels throughout the measurement configuration, there is also a need to calibrate the volume in the devices themselves. Specifics are as follows:
Phone Model Sony Ericsson W995 Sony Ericsson Xperia arc Sony Ericsson Xperia arc S Nokia C7 Huawei C8600 Volume Setting in Phone GUI 5 steps Max Max Max 4 steps

These settings still apply if phones of different models call each other.

106

Chapter 16. Preparations for AQM with Audio Capturing Unit (ACU)

16.7.

Speech Samples for Audio Quality Measurement

The default speech samples used for AQM (WAV files) are stored under My Documents\TEMS Product Files\TEMS Investigation 14.1\PESQ. Different samples are used for PESQ and POLQA. It is possible to exchange these samples for others by editing the file Investigation.QualityMeasurement.config which is found under <TEMS Investigation install dir>\Application\Configuration. Any other samples used must also reside in the directory given above. Note: Bear in mind that replacing the default speech samples could impact the accuracy of AQM scores, since the default samples have been designed to exhibit specific characteristics with regard to speech content, speech volume level, speech distribution within the sample, and more. The number of samples should always be four. At least this many samples must be provided; on the other hand, if more samples are listed in Investigation.QualityMeasurement.config, only the first four will be used. Samples should not be longer than 8 seconds; the default speech samples are of length 5.5 s. The speech activity in the samples should be between 40% and 80%, and there should be a minimum of 3.2 s of active speech in each sample ( ITU-T Recommendation P.862.3, section 7.2). Sample rates must conform to those of the default speech samples; note that these differ between AQM algorithms as well as between the playback samples and those fed as references into the AQM algorithm. As far as languages are concerned, the following applies: PESQ is expected to work for speech in any language; but since it has been tested, validated and calibrated with a limited number of languages, the accuracy of PESQ for other languages is poorly known. In practice, this means that using samples in languages other than Western European ones (e.g. British or American English, German, Dutch, Swedish, French) cannot be recommended. POLQA has been validated with a wider range of languages: American English and British English, Chinese (Mandarin), Czech, Dutch, French, German, Swiss German, Italian, Japanese, and Swedish.

NT12-6999 ver 1.0

107

TEMS Investigation 14.1 Getting Started Manual

17.

Connecting and Activating External Equipment

See the Users Manual, chapter 8.

108

Chapter 18. Cell Data and Maps

18.

Cell Data and Maps

Two aspects of the data presentation in TEMS Investigation require some preparation: Presenting cell data Displaying background maps How to load cell files is described in the Users Manual, section 6.3. How to load map files is the subject of sections 31.331.4 of the Users Manual.

These things are addressed in the Users Manual:

NT12-6999 ver 1.0

109

TEMS Investigation 14.1 Getting Started Manual

110

Index

Index

Symbols
.NET Framework 18

A
Access Point Name (APN) 76 accessories 9 ACU 19, 68 adjusting physical controls 101 configuring Windows settings for 105 connecting equipment to 102 driver installation 53 settings in the TerraTec user interface 103 administrator rights on PC, actions requiring 58 Aero Glass 61, 63 Altair chipset based devices connectable (LTE) 67 Andrew scanners 80 configuration of 86 Anritsu scanners 77 basic configuration of ML8720 model 77 cable to use with ML8720 model 77 USB driver for ML8780A 50 APN (Access Point Name) 76 AQM licensing for 8 with ACU calibrating phones 106 devices capable of 72 driver installation 53 preparations for collecting AQM data 101 speech samples 107 with Call Generator/MRU devices capable of 72 drivers for AQM modules 52 AQM modules 68

NT12-6999 ver 1.0

111

TEMS Investigation 14.1 Getting Started Manual

Audio Capturing Unit 19 See ACU automatic updating of software 58 AutoPlay 58

B
backpack (TEMS Indoor Backpack) 51 Base Packages 6

C
Call Generator 19 installing 64 cell data importing 109 Computer Diagnostics utility 21, 54 running 54 connectable phones and data cards, list of CDMA 67 LTE 67 TD-SCDMA 67 UMTS 65 contents of Getting Started Manual 1

D
data service testing configuring devices for 76 data services 4 Datang LC8130E 67 Datang LC8143 67 Datang phones USB drivers for 41 Datang PostInstall utility 41, 76 definitions of TEMS Investigation concepts 3 detach/attach of software-based license offline 28 online 25 Documents folder 59 DRT4301A+ scanners 80 configuration of 83 configuring for local area network connection 84 connecting RF antenna to 85 DRT4302 transmitters configuration of 93

112

Index

E
energy saving features in Windows 59 equipment cases 2 Ericsson Fixed Wireless Terminals 68 configuration of 81 PC configuration for 81 external antennas connecting to phones 75 external equipment 65 connecting in TEMS Investigation 108

F
FAQ (on TEMS website) 3 firewall in Windows 60

G
GCT chipset based devices connectable (LTE) 67 GPS protocols, supported 69 GPS units list of supported 69 USB drivers for 51

H
hardware requirements for installing TEMS Investigation 16, 18 hardware-based licensing 23 HASP HL 11, 23 HASP key driver for 12 updating 34 HASP license server hardware requirements 18 HASP runtime network activity 37 HASP SL 11, 23 HASP software protection 23 HASP SRM Remote Update utility 20 Hisilicon chipset based devices connectable (LTE) 67 Hisilicon UE Agent 42, 74 HTC Vivid 65 Huawei C8600 72

I
indoor backpack 10, 77 Information Elements and Events volume 1

NT12-6999 ver 1.0

113

TEMS Investigation 14.1 Getting Started Manual

installing TEMS Investigation 16, 20 Internet Explorer 18 Iperf 19 IPv6 60, 62 IR port 58

K
Kyocera KX5 72

L
LG CU320 66 LG CU500 66, 72 LG U960 66 licensing in TEMS Investigation 11 floating license 9, 11 for AQM 8 for external devices 7 inspecting the scope of your license 13 license requirements 12 licensing solutions 11 local license 11 network license 9, 11

M
Manual UE Configuration utility 21, 41, 43 maps, importing 109 Microsoft Core XML Services 18 Microsoft DirectX 18 Mobile Receiving Unit 19 MRU 19 MSXML 18 My Documents folder 59

N
Network Bandwidth testing, hardware requirements and preparations 19 Nokia 6120 66 Nokia 6121 66 Nokia 6720 66 Nokia C5 66 Nokia C7-00 65, 71, 72 Nokia GSM phones Net Monitor function 74 USB driver for 43 Nokia N95 66

114

Index

Nokia N96 66 using external antenna with 76 Nokia PC Suite 59 Nokia UEs Net Monitor function 74 USB driver for 43

O
operating system requirements for installing TEMS Investigation 17

P
PC configuration for Andrew scanners 86 for DRT scanner 83 for DRT transmitter 93 for Ericsson Fixed Wireless Terminal 81 for Rohde & Schwarz TSMW scanner 91 PC settings for TEMS Investigation, recommended 57 PCTel PCT scanners 78 USB driver for 51 PCTel scanners antenna cable attenuation 79 reference point for signal level measurement 78 PCTel SeeGull EX scanners 78 USB driver for 51 PCTel SeeGull LX scanners 77 USB driver for LX MM2 51 PCTel SeeGull MX scanners 78 USB driver for 51 phones 3 list of connectable (CDMA) 67 list of connectable (LTE) 67 list of connectable (TD-SCDMA) 67 list of connectable (UMTS) 65 port-scanning software 59 power management in Windows 7 61 in Windows Vista 62 in Windows XP 63 product packaging 6

Q
Qualcomm chipset based devices connectable (CDMA) 67

NT12-6999 ver 1.0

115

TEMS Investigation 14.1 Getting Started Manual

connectable (LTE) 67 connectable (UMTS) 66 enabling diagnostics reporting 74 USB driver for 43

R
Release Note 2 Replay Packages 7 Rohde & Schwarz TSMW scanner 80 configuration of 91 RTP ports for video streaming 59

S
Samsung Galaxy S 4G 65, 71 USB driver for 43 Samsung Infuse 4G 65 USB driver for 43 Samsung SPH-M320 72 Samsung SPH-M330 72 scanners 3, 68 screen savers 59 security products 59 Sequans chipset based devices basic configuration of 74 connectable (LTE) 67 Sierra Wireless AC319U 65, 71 sleep mode in Windows 59 software requirements for installing TEMS Investigation 18 software updates, automatic check for 21 software-based licensing 23 Sony Ericsson Android phones basic configuration of 73 driver installation for 41 Sony Ericsson C702 65 Sony Ericsson C905 65 Sony Ericsson C905a 65 Sony Ericsson K600i 66 Sony Ericsson K790a 67, 72 Sony Ericsson K790i 67, 72 Sony Ericsson K800i 66, 72 Sony Ericsson PC Suite 59 Sony Ericsson phones USB drivers for 40

116

Index

Sony Ericsson TM506 66 Sony Ericsson W600i 67 Sony Ericsson W760i 66 Sony Ericsson W995 66, 72 Sony Ericsson W995 EDGE 66, 72 Sony Ericsson W995 models configuring USB speed 73 using external antenna with 75 Sony Ericsson W995a 66, 72 Sony Ericsson Xperia arc LT15a 65, 71, 72 Sony Ericsson Xperia arc LT15i 65, 71, 72 Sony Ericsson Xperia arc S LT18a 65, 72 Sony Ericsson Xperia arc S LT18i 65, 72 Sony Ericsson Xperia X10 66 Sony Ericsson Z750i 66, 72 using external antenna with 75 SpeedStep technology 58 SRUs USB driver for 43 support contact information 3

T
TC-1520 equipment case 51, 77 TC-1520B equipment case 51, 77 TC-1520C equipment case 51, 77 TC-1520D equipment case 51, 77 TC-1520E equipment case 51, 77 Technical Reference volume 1 TEMS Bulletins 3 TEMS Indoor Backpack 51 TEMS Pocket 2 TEMS Pocket Positioning Tool 21 terminals 3 TerraTec DMX 6Fire USB 101

U
UAC in Windows 7 61 in Windows Vista 62 UDP ports for video streaming 59 UDP testing hardware requirements 19 uninstalling TEMS Investigation 22 updating HL keys 34

NT12-6999 ver 1.0

117

TEMS Investigation 14.1 Getting Started Manual

updating SL keys 34 USB drivers for user terminals 40 USB Legacy Support 60 USB-to-RS232 serial converter in equipment cases/backpack, driver for 51 User Access Control in Windows 7 61 in Windows Vista 62 user terminals 3 basic configuration of 73 capabilities of terminals sold with TEMS Investigation 70 Users Manual 1

V
Via chipset based devices connectable (LTE) 67 video streaming hardware requirements on streaming server 19 video streaming, RTP (UDP) ports for 59 visual effects in Windows Vista 61, 63 in Windows XP 63 VoIP hardware requirements 19

W
WiMAX configuring PC for DRT scanner 83 Windows 7 settings required 60 Windows Aero color scheme 61, 63 Windows firewall 60 Windows Media Player 60 deleting registry keys for (Windows XP) 63 Windows Vista settings required 62 Windows XP settings required 63

118

www.ascom.com/tems

The TEMS Portfolio offers a complete set of trusted solutions for drive testing, benchmarking, monitoring,andanalyzingnetworkperformance. These state-of-the-art offerings facilitate the deployment,optimization,andmaintenanceofmobile networks. Wearetheindustryleader,andourproductsare suppliedtotheworldstopmobileoperators,equipmentvendors,andprofessionalserviceproviders.

Ascomreservestherighttochangespecificationswithoutnotice.Ascomacknowledgesallregisteredtrademarksappearingherein.

AscomNetworkTestingInc. 1943IsaacNewtonSquare Reston,Virginia20190|USA www.ascom.com/tems

04.2012 Ascom 2012. All rights reserved. TEMS is a trademark of Ascom . All other trademarks are the property of their respective holders.

AScoM NETwork TESTiNg lEAdS ThE world iN providiNg bEST-iN-clASS SoluTioNS To MEASurE, ANAlyzE, ANd opTiMizE MobilE NETworkS.

S-ar putea să vă placă și