Sunteți pe pagina 1din 3

4200 Holland Boulevard Chesapeake, VA 23323

Tel (757) 485-3355 Fax (757) 485-4441


www.sumitomodrive.com

LOAD CALCULATION SHEET


All calculations are general and do not take into account coefficients or other factors that may effect the load calculations.
*Please have your customers confirm and agree with any calculations you do from this sheet.
(All calculations have been taken from the CYCLO 6000 Catalog [General Engineering Section])
ENTER NUMBERS IN ALL THE BLUE AREAS AND DO NOT CHANGE THE RED NUMBERS.

FORMULA
VELOCITY (FPM) LINEAR OR
ROTATIONAL

RPM

DIAM OR P.D. OF WHEEL(IN.)

HORSEPOWER

TORQUE ( IN. LB)

RPM OF SHAFT

FORMULA

REQUIRED
DIAM. AND
RPM

RESULT

.262 X

PITCH DIA. X

RPM=

FPM
VELOCITY

0.262
0.262

17.0
17

20.0
20

89.08
89.08

FPM /

.262 X

DIAM =

RPM

100.0
100

0.262
0.262

16.5
16.5

23.13
23.13

Feet per min


(FPM)

.262 X

RPM

DIA.

1.0
1

0.262
0.262

0.62
0.62

6.16
6.16

TORQUE
(IN.LB)

TORQUE

X RPM

63025

HP REQ.

FINAL RPM

48,037
48037

17.18
17.18

63,025
63025

13.09
13.09

HP, RPM OF
SHAFT

HP X

63025

/ RPM=

TORQUE

3.0
3

63,025
63025

12.2
12.2

15,498
15498

HP X

63025

/ TQ. =

RPM

3.0
10

63,025
63025

12.2
378000

15,498
1.67

V, DIAM, RPM

FPM/.262X
RPM

HP, TQ

TORQUE REQ. IN.LB

F=FORCE,OR
PULL (LB'S)

FORCE LB X

RADIUS=

TORQUE

Coeff.

Req. Torque

7,040
7040

8.5
8.5

59,840
59840

0.250
0.25

14,960
14960

FPM /

33000=

HP

3,000
3000

12
12

33,000
33000

1.09
1.09

HP X

33000 /

VEL =

FORCE

0.50
0.5

33,000
33000

94.0
94

175.5
176

HP X

33000/

FORCE =

FPM

Friction Coefficient (f)


HP REQUIRED

EFFECTIVE
FORCE (F) LBS

VELOCITY (FPM)

EFF. TENSION (LBS)

EFF. TENSION/ LBS


BASED HP

3 PHASE MOTOR HP

LBS RADIUS

HP, VEL,

HP, FORCE

1.00
1
HP, RPM, RAD.

33,000
3,000.0
33000
3000

Belt/Rollers = 0.25
Fabric/Steel = 0.27
Plastic/Steel = 0.35
Rubber/Steel = 0.50
Leather/Steel = 0.56

11.0
11

TQ. IN.LB

/ RADIUS

LBS

36,685
36685

88

4,585.625
4585.625

HP X

33000 /

FPM =

TENSION

10.00
10

33,000
33000

55.0
55

6,000.0
6000

VOLTS X

AMPS X

EFF.MTR

x PF

X 1.73

/ 746

HP

480
480

2.80
2.8

0.825
0.825

0.756
0.756

1.73
1.73

746
746

1.94
1.94

HP, FPM

TAKE ALL INFORMATION OFF THE MOTOR NAMEPLATE OR USE MOTOR SPEC. SHEET

DC MOTOR HP

Nm TO LB.IN.

KW TO HP

VOLTS

X AMPS

X %EFF

/ 746

HP

480
480

4.00
4

0.870
0.87

746
746

2.24
2.24

NEWTON
METER

X 8.8507=

LB.IN.

390.0
390

8.8507
8.8507

3,452
3452

KW X

1.341 =

HP

37.0
37

1.3410
1.341

49.62
49.62