Electronics line (E.L) Ltd.

- Summit 3208GLD Household Burglary and Fire Alarm Panel

Connector for plug-in relay module

Electronics line (E.L) recommends testng the system at least once a week. Rafer to the testing procedure found in the installation manual Receiver communication must be tested monthly. For maximum current calculation, add keypad consumption (approx. 60mA per keypad) t the total current drawn from the AUX power output. 1 2 3 4 5
BLACK Telephone Line Connections

PROTECTION FUSES F1 (BATT): 3A/250V (bel 5MF3) F2 (AUX): 1.6A/250V (bel 5MF1.6) F3 (BELL): 3A/250V (bel 5MF3) Install F3 horizontally to supply 12v nominal regulated power to bell. Install vertically to supply 9-18V unregulated to bell and terminal 28. AUXILIARY POWER OUTPUT Regulated 12VDC nominal. Fire: Supplies 220mA for 24 hours Burglary: Supplies 1A for 4 hours (inclding 100mA to smoke detector. terminasl 24 and 25) 14 15 16 17

F1

12V 7Ah BATTERY Charging current 700mA max. Replace the battery every 3 - 5 years

F3

F2 RED BLACK

System Bus Connector

LED SYSTEM STATUS INDICATOR On = Telephone Tone Detection Off = System in Communication Flashing = Dialing Flashing (1 pulse/sec) = Standby

6
RED

7
GREEN

8
WHITE

10 11 12 13

18 19 20 21 22 23 24 25 26 27 28 29 30

Mic Input

Connect to Earth

Z1

Z2

Z3

Z4

Z5

Z6

Z7

Z8 (+) (-) Smoke Detector Output AUX Power Output

Siren Audio Output 600mA

Transformer 15VAC/30VA

Zone Connections

3108/3118/3126 LCD Keypad N.C. Typical End of Line Resistr Zone Connections (EOLR)

12V nominal max. 100mA N.C.

Unregulated Power Output (9-18V)

Power connection to the unit should be according to the national electrical code for permanent installation

2.2K 2.2K 3106 LED Keypad System Bus