Sunteți pe pagina 1din 3

[nasadmin@NNcloud1-CS0 var]$ uname -a Linux NNcloud1-CS0 2.6.18-128.1.1.6007.

EMC #1 Fri Jun 17 15:14:41 EDT 2011 i686 i686 i386 GNU/Linux [nasadmin@NNcloud1-CS0 var]$ nas_version 7.1.65-8 [nasadmin@NNcloud1-CS0 var]$ nas_storage -i id=1 | grep -i microcode microcode_version = 05.32.000.5.201 microcode_version = 05.32.000.5.008 [nasadmin@NNcloud1-CS0 var]$ nas_storage -l id acl name serial_number 1 0 CKM00125200822 CKM00125200822 [nasadmin@NNcloud1-CS0 var]$ /nas/sbin/navicli -h spa getagnet Management Server - Feature software is not installed or the command may have be en typed incorrectly Possible commands are, migrate Security modepassthru nqm alpa bind clearstats uration failovermode getagent g getcontrol getlun getsptime nfig luncache port nfig managedby powersaving managefiles rebootpeersp mirrorview rebootSP ndu remoteco compression spcollect networkadmin mirror arraycommpath cachecard convertemlog faults getall getcrus getresume getunusedluns connection arrayconfig server sancopy arrayname chglun createrg firmware getarrayuid getdisk getrg initializearray isns EventMonitor metalun clone backendbus chgrg copytohotspare flashleds getcache getlog getsniffer inserttestevent Domain ntp analyzer

baseuuid clearlog emconfig flash getconfi getloop getsp ioportco

removerg re setloop e setstats roup systemtype

resetandhold setraid5 shutdown spportspeed

responsetest setsniffer shutdownSP trespass lun

setcache setspstime shutdownpeerSP unbind cache

setfeatu setsptim storageg unitseri storagep snapview

alnumber environment snap

ool thin thinlun autotiering reserved [nasadmin@NNcloud1-CS0 var]$ /nas/sbin/navicli -h spa getagent Agent Rev: Name: Desc: Node: Physical Node: Signature: Peer Signature: Revision: SCSI Id: Model: Model Type: Prom Rev: SP Memory: Serial No: SP Identifier: Cabinet: 7.32.25 (1.56) K10 A-CKM00125200822 K10 3354970 3355092 05.32.000.5.201 0 VNX5300 Rackmount 7.00.00 8192 CKM00125200822 A DPE7

[nasadmin@NNcloud1-CS0 var]$ /nas/sbin/navicli -h spb getagent Agent Rev: Name: Desc: Node: Physical Node: Signature: Peer Signature: Revision: SCSI Id: Model: Model Type: Prom Rev: SP Memory: Serial No: SP Identifier: Cabinet: 7.32.25 (1.56) K10 B-CKM00125200822 K10 3355092 3354970 05.32.000.5.201 0 VNX5300 Rackmount 7.00.00 8192 CKM00125200822 B DPE7

[nasadmin@NNcloud1-CS0 var]$ nas_version 7.1.65-8 [nasadmin@NNcloud1-CS0 var]$ nas_storage id=1 | grep microcode [nasadmin@NNcloud1-CS0 var]$ nas_storage id=1 | grep -i microcode

[nasadmin@NNcloud1-CS0 var]$ nas_storage -info id=1 | grep -i microcode microcode_version = 05.32.000.5.201 microcode_version = 05.32.000.5.008 [nasadmin@NNcloud1-CS0 var]$ nas_storage -sync -all done [nasadmin@NNcloud1-CS0 var]$ nas_storage -check -all Discovering storage on NNcloud1-CS0 (may take several minutes) done [nasadmin@NNcloud1-CS0 var]$ nas_storage -info id=1 | grep -i microcode microcode_version = 05.32.000.5.201 microcode_version = 05.32.000.5.201 [nasadmin@NNcloud1-CS0 var]$