Sunteți pe pagina 1din 1

M88

PLANT NO.

NOM. SCH.
TYPE PIPE OR
NOS. SIZE THK.
(IN.)
3E
3H
3M

DB-950055 001 00

J
INDEX

X"

"

DRAWING NUMBER

SHT. NO.

REV. NO.

"Z"

Z
4

Z
4
PLATE "Y"

Z
4

ALL INTERSECTIONS
SHALL BE TACK WELDED
AT BOTH ENDS

Z
4

PLATE "Z"

4H
4K

3-31/32

27/32

3-3/16

3-3/4

13/16

3-9/16

80
120

15

5-11/16

1-9/32

4-5/8

5-7/16

1-7/32

160

4-11/32

5-1/8

1-5/32

30
40

6-27/32

1-7/8

6-25/32

7-29/32

1-27/32

60
80

6-5/8

7-3/4

1-13/16

6-15/32

7-9/16

1-3/4

6-5/16

7-3/8

1-23/32

80
120

100

21

25

120
140

6-3/32

7-1/8

1-21/32

5-15/16

6-15/16

1-19/32

160

5-3/4

6-3/4

1-9/16

30
40

8-21/32

10-1/16

2-3/8

8-17/32

9-15/16

2-11/16

8-5/16

9-11/16

2-9/32

8-5/32

9-1/2

2-1/4

ISOMETRIC VIEW OF VANE

10E
10G

VANES SHALL BE TAGGED WITH


TYPE NUMBER

10H

80

10J
10K

100
120

7-15/16

9-1/4

2-3/16

7-23/32

2-1/8

12C

30

10-11/32

12

2-7/8

12G
12H

M
M

Z
4

Z
4

Z
4

Z
4

1/8 1/8
"
1/8
"
"

"X"

"Z"

3-11/32

4-27/32

8J
8K

1/8 " 1/8 " 1/8 "

40

10

1/8 "
SLIDING
FIT FOR
INTERSECTING
THICK PLATES

X
2
1/8 " THICK
PLATE

PLATE "Y" DETAIL

1/8 "
SLIDING
FIT FOR
INTERSECTING
PLATES

PLATE "Z" DETAIL

(4 REQUIRED PER UNIT)

(2 REQUIRED PER UNIT)

60

26

10-1/4

3/8 "

12

40

10-3/16

1/2 "
29
60
80

10-1/16

11-11/16 2-23/32

9-15/16

11-9/16

2-3/4

9-11/16

11-5/16

2-11/16

11

2-5/8

11-7/8

9-7/16
9-3/16

10-11/16 2-17/32

14A
14B

10
20

11-9/16

13-7/16

3-7/32

11-7/16

13-5/16

3-3/16
3-5/32

14C

30

11-11/32

13-3/16

16A
16B

10

13-9/32

15-7/16 3-23/32

13-3/16

15-5/16

16 OD

20

37

22

1-1/2

PRACTICABLE AT BOTH ENDS.


26

27

2-1/2

30

33

3-1/2

38

3-11/32

16C

30

13-1/16

15-3/16 3-21/32

18A
18B

10
20

15-1/32

17-7/16

4-7/32

14-29/32

17-5/16

4-3/16 43

14-13/16

17-3/16

4-5/32

18 OD

42

3/8 "

18C
20A
20B

20 OD

10
20

24B
24F

24 OD

20
57
1/2 "

47

16-3/4
16-17/32
20-1/32

4. ALL OTHER NON-MAXIMUM ACCURACY GAS


METERS, ORIFICE RUNS, OR SMALLER SIZE
TURBINE METER INSTALLATIONS MAY APPLY
STRAIGHTENING VANES MADE UP OF
PLATES WHEN THE UPSTREAM METER RUN
AVAILABLE IS LESS THAN THE LENGTH
REQUIRED FOR BETA RATIO OF 0.75.

2-27/32

100
120
32

16

3. ALL GAS SALES METERS, MAXIMUM


ACCURACY ORIFICE RUNS AND 6 INCH OR
LARGER TURBINE METERS WITH LESS THAN
50 PIPE DIAMETERS OF UPSTREAM METER
RUN SHALL USE STRAIGHTENING VANES
MADE UP OF BUNDLES OF SMALL TUBES
WELDED TOGETHER. THE AREA OF
1/16 TH
INDIVIDUAL TUBES MUST NOT EXCEED
THE
INSIDE
AREA
OF
THE
PIPE.
OF
THE LENGTH OF THE TUBES MUST BE AT
LEAST 10 TIMES THE I.D. OF TUBES. ALL
TUBES SHOULD BE REAMED AS THIN AS

11-15/16 2-27/32

12J
12K
14 OD

1. MATERIAL SHALL BE WELDABLE QUALITY


CARBON STEEL.

2. TOLERANCE ON DIMENSIONS "Y" AND


"Z" : +0, 1-32 IN.
1
TOLERANCE ON DIMENSION "M" :+
- 32 IN.
OTHER DIMENSIONS NOMINAL.
3/4

1/2

1-3/8

8G

"X"

2-9/16

12F

Z
4

2-1/8

5-1/8

12E

Z
4

160

9/16 14

40

12D

"Y"

2-13/16

13

6E
6H

10C

1/8 "
PLATE

2-3/8

80

SPOOL PIECE
DIM. LG. OF
"V" WELD "W"
(IN.) (IN.)

5/8

3-3/8

8L
8M

X
2

2-27/32

8H

STRAIGHTENING VANE
ASSEMBLY

2-1/2

160

8E

"Y"

(IN.)

4M

8C

PLATE "Z"

DIM.
"M"

3/4
23/32

6K
6M

PLATE "Y"

WIDTH "Y" WIDTH "Z"


LG.
FOR
FOR
"X" PLATE "Y" PLATE "Z"
(IN.)
(IN.)
(IN.)

40

4E
( I.D. OF PIPE- 1/16 " )

Z
4

"Y"

( I.D. OF PIPE- 1/16 " )

"Z"

( I.D. OF PIPE- 1/16 " )


Z
4

NOTES:

VANE AND SPOOL PIECE DIMENSIONS

19-7/16 4-23/32
19-3/16

4-21/32

23-3/16 5-21/32

19-25/32 22-15/16 5-19/32

4-1/2

48

58

"X"
VANE WELDED TO
SPOOL PIECE

(I)

FORMERLY STD. DWG. NO. AB-036965, SHT. 001, REV. 04

VANE WELDED TO
SPOOL PIECE

(I)

REV.
DATE
NO.

BY JO/EWO

SAUDI
RCR

DRAWN BY

DESCRIPTION

ARABIAN

1/2 "
APPROX.

OIL COMPANY

CHECKED BY

SCALE

DATE COMPLETED

DATE STARTED

FLANGE TYPE SHOWN


IS TYPICAL ONLY

CHKD. CERT. APPD.

NONE

NOV96

ENG. DEPT.

OPRG. DEPT.
APPD FOR CONSTR.

W
"V"

CERTIFIED

CONSTRUCTION OR FOR ORDERING


MATERIAL UNTIL CERTIFIED AND DATED

APPROX.

VIEW SHOWING VANE INSTALLED IN A PIPE SPOOL PIECE


SPOOL PIECES SHALL BE TAGGED WITH TYPE NUMBER

THIS DRAWING IS NOT TO BE USED FOR

1/2 "
(I) THE BUTT WELD SHALL BE
SUBSTANTIALLY FULL PENETRATION
AND WITH ANY PROJECTIONS
INSIDE THE PIPE GROUND SMOOTH
AND FLUSH WITH THE INSIDE
SURFACE OF THE PIPE.

BY

DATE

STANDARD STRAIGHTENING VANE


AND PIPE SPOOL PIECE FOR
FLOW METER ORIFICE RUNS
SAUDI ARABIA

LIB. DWG.
PLANT NO.

M88

INDEX

DRAWING NUMBER

DB-950055

SHT. NO.

REV. NO.

001 00

Saudi Aramco 2634 ENG. (3/91)

CADD-02