Jumper cable. VSWR WRFU Rx attenuation (huawei) MHA settings (NSN) issue from transmission frequencies

NSN Case: 1. NPO or performance team can check on which date high noise floor appeare d, if it s related to NIP migration NI will have to go back and trouble shoot. 2. In case the noise floor was high before NIP migration, power levels of a ll neighbor sites need to be checked and reduced temporarily to see to impact on noise floor level. 3. Site master measurement for affected cell for complete feeder line & MHA & antennas. 4. Over the air measurements with pilot scanner too many strong sectors at the s ame location creates pilot pollution. This leads to low data rate, low capacity and excessive soft handoffs. 5. Change or swap MHA s between sectors or sites.