Sl. No.
Type
Dia. (mm)
Service
Location
Operation
22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41
106UV-0126 106UV-0123 106UV-0125 106UV-0124 106UV-0128 106UV-0151 106UV-0155 106UV-0153 106UV-0152 106UV-0154 106UV-0131 106UV-0129 106UV-0132 106UV-0130 106UV-0133 106UV-0166 106UV-0168 106UV-0165 106UV-0164 106UV-0171
BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV
Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type
BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05
150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150
RWR TW RWR RWR WA RWR TW RWR RWR WA RWR TW RWR RWR WA RWR WA RWR TW RWR
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 5
Softener A to backwash Outlet (Stage 1) Softener Vessel A to Header line to Softener Vessel Stage 2. (Stage 1) Softener Vessel A to DGT Tower. (Stage 1) Softener Vessel A to Slow rins out (Stage 1) Softener Vessel A to Softener Regeneration Waste Sump. (Stage 1) Softener B to backwash Outlet (Stage 1) Softener B to Header line to Softener Vessel B Stage 2. (Stage 1) Softener Vessel B to DGT Tower. (Stage 1) Softener Vessel B to Slow rins out (Stage 1) Softener Vessel B to Softener Regeneration Waste Sump. (Stage 1) Softener C to backwash Outlet (Stage 1) Softener C to Header line to Softener Vessel C Stage 2. (Stage 1) Softener Vessel C to DGT Tower. (Stage 1) Softener Vessel C to Slow rins out (Stage 1) Softener Vessel C to Softener Regeneration Waste Sump. (Stage 1) Softener Vessel A Stage 2 to backwash outlet Softener Vessel A Stage 2 to Softener Regeneration Waste Sump Softener Vessel A Stage 2 to slow rins out Softener Vessel A Stage 2 to Header Line to RO MCF Softener Vessel B Stage 2 to backwash outlet
Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic
Close Open Close Close Close Close Open Close Close Close Close Open Close Close Close Close Close Close Open Close
Page 1 of 2
Valve Schedule for Butterfly Valve Description of Valves VMS Specification P&ID Sheet No. Air Fail to Close/Open
Sl. No.
Type
Dia. (mm)
Service
Location
Operation
42 43 44 45 46 47 48 66 93 104 106 108 111 112 115 121 126 130 132 139
106UV-0172 106UV-0169 106UV-0170 106UV-0176 106UV-0177 106UV-0175 106UV-0174 UV-0139 UV 0138 UV 0148 Tag Miss FV 0109 UV 0160 UV 0149 Tag Miss Tag Miss Tag Miss Tag Miss FV 0118 FV 0129
BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV BFV
Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type Wafer Type
BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-04 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-05 BFV-04 BFV-04
5 5 5 5 5 5 5 6 8 8 8 8 8 8 9 9 10 10 14 16
Softener Vessel B Stage 2 to Softener Regeneration Waste Sump Softener Vessel B Stage 2 to slow rins out Softener Vessel B Stage 2 to Header Line to RO MCF Softener Vessel C Stage 2 to backwash outlet Softener Vessel C Stage 2 to Softener Regeneration Waste Sump Softener Vessel C Stage 2 to slow rins out Softener Vessel C Stage 2 to Header Line to RO MCF Service Water to CIP system Service Water for Flush in outlet of DTRO Feed Pump 1 ERT discharge Line to DTRO Stage 1 Bypass to Evaporator Feed Tank DTRO Module permeate Header line to Permeate Storage Tank (Stage 1) Bypass line between ERT DTRO Module Permeate line to DTRO Feed Tank ERT Discharge Line to DTRO Feed Tank 2 Service water for Flush to discharge of DTRO Feed pump (Stage 2) DTRO Module permeate Header line to Permeate Storage Tank (Stage 2) DTRO CIP Pump outlet CIP Pump discharge line DTRO CIP tank for Bypass Service water to at mixing Tee of Softener Regeneration Pump Outlet . Alkali Regeneration Pump Outlet at mixing Tee from Service water pump
Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Flow Control Valve Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Pneumatic Flow Control Valve Flow Control Valve
Close Close Open Close Close Close Open Close Close Close Open Close Close Close Close Open Close Close Close Close
Page 2 of 2