Sunteți pe pagina 1din 2

Drop Cable

6 Series
Construction Code

Bonded Foil Standard Construction


Shipping Wt. (Lbs.) /1000'

60% BRAID
F660BV F660BVV F660BVM F660BEF F2-660BVV F660BVV-APD F660BVV-CRD

Product Description

Bonded foil, 60% braid, PVC jacket. Bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, PVC jacket, .051 inch messenger. Bonded foil, 60% braid, flooded for underground, PE jacket. Dual cable, bonded foil, 60% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, flame retardant PVC jacket, amorphous polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, flame retardant PVC jacket, hydrophobic dry powder moisture repellent. Meets NEC Article 820 V Rating. (UL listed)

33 34 48 30 71 34 34

90% BRAID
F690BV F690BVV F690BVM F690BEF
Bonded foil, 90% braid, PVC jacket. Bonded foil, 90% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 90% braid, PVC jacket, .051 inch messenger. Bonded foil, 90% braid, flooded for underground, PE jacket. Dual cable, bonded foil, 90% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) 34 34 49 31 73

F2-690BVV

60% BRAID
Construction Code

Bonded Foil Tri-Shield Construction


Product Description Shipping Wt. (Lbs.) /1000'

F6TSV F6TSVV F677TSVV F6TSVM F6TSEF F2-6TSVV F6TSVV-APD F6TSVV-CRD

Bonded foil, 60% braid, non-bonded tape, PVC jacket. Bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 77% braid, non-bonded tape, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, PVC jacket, .051 messenger.

34 34 34 53

Bonded foil, 60% braid, non-bonded tape, flooded for underground, PE jacket. 36 Dual cable, bonded foil, 60% braid, non-bonded tape, flame retardant PVC jacket. Meets Article 68 820 V Rating. (UL listed) Bonded tape, 60% braid, non-bonded tape, flame retardant PVC jacket, amorphous 32 polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded tape, 60% braid, non-bonded tape, flame retardant vinyl jacket, hydrophobic dry powder moisture repellent. Meets NEC Article 820 V Rating. (UL listed) 32

Construction Code

60% + 42% BRAID


F6SSV F6SSVV F6SSVM F6SSEF F2-6SSVV F6SSVV-APD F6SSVV-CRD

Bonded Foil Super-Shield Construction


Shipping Wt. (Lbs.) /1000'

Product Description

Bonded foil, 60% braid, non-bonded tape, 42% braid, PVC jacket. Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 42% braid, PVC jacket, .051 messenger. Bonded foil, 60% braid, non-bonded tape, 42% braid, flooded for underground, PE jacket. Dual cable, bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket. Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket, amorphous polypropylene flooding compound (non-flowing). Meets NEC Article 820 V Rating. (UL listed) Bonded foil, 60% braid, non-bonded tape, 42% braid, flame retardant PVC jacket, hydrophobic dry powder moisture repellent. Meets NEC Article 820 V Rating. (UL listed)

44 44 62 38 87 45 45

6 Series Specifications
Standard Construction
18 gauge [0.040 in. (1.02 mm)] copper covered steel center conductor; gas expanded polyethylene dielectric; inner shield aluminum-polypropylene-aluminum laminated tape with overlap bonded to dielectric; outer shield of 34 AWG bare aluminum braid wire; jacket of black polyvinylchloride or polyethylene (flooded). Nominal O.D. 0.272 in. (6.91 mm).

Physical Dimensions
Component

Standard Shield Inches mm

Tri-Shield Inches mm

Super-Shield Inches mm

Nominal Center Conductor Diameter Nominal Diameter Over Dielectric Nominal Diameter Over First Shield (Tape) Nominal Diameter Over Jacket Nominal Jacket Wall Thickness Nominal Diameter of Steel Messenger

0.040 0.180 0.187 0.272 0.030 0.051 0.072


(single) (dual)

1.02 4.57 4.75 6.91 0.76 1.30 1.83

0.040 0.180 0.187 0.278 0.030

1.02 4.57 4.75 7.06 0.76

0.040 0.180 0.187 0.300 0.034 0.051 0.072


(single) (dual)

1.02 4.57 4.75 7.62 0.86 1.30 1.83

0.051 (single) 1.30 0.072 (dual) 1.83

Mechanical Characteristics
Minimum Breaking Strength of Messenger 0.051 0.072 180 lbs. 365 lbs. 82kgf 166kgf

Attenuation [@ 68 F. (20 C.)]


Frequency (MHz) Maximum (dB/100 ft.) Maximum (dB/100 m)

5 55 / Channel 2 83 / Channel 6 187 / Channel 9

0.58 1.60 1.95 2.85 3.05 3.30 3.55 3.85 4.15 4.40 4.66 4.90 5.10 5.65 6.10 6.55

1.90 5.25 6.40 9.35 10.00 10.82 11.64 12.63 13.61 14.43 15.09 16.08 16.73 18.54 20.01 21.49

Electrical Characteristics
Nominal Impedance Nominal Velocity of Propogation 75 Ohms 85%

211 / Channel 13 250 300 350 400 450 500 550 600 750 865 1000

Corrosion Resistant Drops (APD & CRD)


Additional products may be available with the corrosion resistant treatment. Contact our sales and marketing office for additional information