Sunteți pe pagina 1din 3

Given values:

Pressure

Temperature

Compressor inlet

1.0325 bar

300K

Turbine outlet

1.0325 bar

815K

Pressure ratio

cycle =

28MW

= 18.6
= 87kg/s (see Figure X in Apendix)

Assumptions:

Constant Pressure
100% Theoretical Air (Combustion)

P (bar)

T (K)

h (KJ/Kg)

Pr

18.84645

1672.37

1846.14

955.67

1.01325

815

838.47

51.38

1.01325

300

300.14

1.3860

18.84645

679.5

691.28

25.78

Table 1: Calculated values states 1 - 4


Calculations leading to values in Table 1:
)(

)(

)(

(
(

)(

)(

)(

)(

(
(

)(

)
)

in
in

)
)

in

out
out

)
)

out

------------------------------------------------P (bar)

T (K)

h (KJ/Kg)

20

293

85.83

20

912

3777.91

Table 2: Joes table for scenario 1 (replace boiler o some shit)

S-ar putea să vă placă și