FOSTER WHEELER USA CORPORATION FIRED HEATER DIVISION

ENGINEERED PRODUCTS, SERVICES AND REPLACEMENT PARTS

DRAFT PROFILE
ATMOSPHERIC PRESSURE LINE

STACK DAMPER
OOOOOO OOOOOO OOOOOO OOOOOO OOOOOO OOOOOO O OOO O O O O O O O O O O O O O OOO O OOOOOO O O O O O O O

O O O O O O

BURNER NEGATIVE PRESSURE DRAFT INCHES H 2 O


ADJUSTMENT STACK DAMPER OPEN MORE CLOSE MORE BURNER REGISTER OPEN MORE CLOSE MORE DECREASES INCREASES DRAFT INCREASES DECREASES

BURNER

POSITIVE PRESSURE INCHES H 2 O


EFFECT O2 INCREASES DECREASES INCREASES DECREASES

Note: For Proper Heater Control - Control Draft with Stack Damper - Control O 2 with Burner Register

FOSTER WHEELER USA CORPORATION FIRED HEATER DIVISION


ENGINEERED PRODUCTS, SERVICES AND REPLACEMENT PARTS

OPERATION CHECKLIST
START CHECK DRAFT HIGH (1) ON TARGET CHECK O2 HIGH (3) CLOSE STACK DAMPER LOW (4) OPEN BURNER REGISTERS HIGH (3) CLOSE BURNER REGISTERS CHECK O2 LOW (4) OPEN STACK DAMPER LOW (2)

RETURN TO START CHECK O2 HIGH ON TARGET CLOSE BURNER REGISTERS RETURN TO START

RETURN TO START

LOW

OPEN BURNER REGISTERS RETURN TO START

GOOD OPERATION
Note: (1) High Draft - Means Fire Box Pressure More Negative than Target (2) Low Draft - Means Fire Box Pressure More Positive than Target (3) High O2 - Means O2 is Above the Target (4) Low O2 - Means O2 is Below the Target