ER 288 Widening of CTE from CTE to Braddell Road Interchange Waterproofing Membrane/Liquid Polymer Membrane Pg./Ref. MW/14/7 Pg.

348 Clause 14.3.2 Title W/P Membrane Description Total Membrane Thickness: 2.5mm minimum dry film thickness applied in two coat, second coat applied after first coat is dried Pg.1/1 Remarks/Test Test to be Done a.Check wet film thickness b.Check dry film thickness c.Test Elongation Break d.Pull Off Test e.Puncture Resistance test

Tensile strength: 4.0 Mpa Minimum in any of three orthogonal plane Membrane Elongation Break:130% minimum Peel adhesion to concrete: 2 Mpa minimum Puncture Resistance: 2N/mm tear of backing film

Parapet and Railings Pg./Ref. MW/13/6 Pg.338 Clause 13.5.5 Title Parapet Railings Description Remarks/Test Test to be Done a. Static Load Test b.Material Test

1% of parapet railings shall be chosen by engineer for Static Load and Material testing in accordance with BS6779 and BD52/93 at accredited Lab