AM-MIO

Input-Output Expansion Interface


For Use With the AM-3, AE-1000, & AE-2000 Access Control Systems

PRODUCT DESCRIPTION
The AM-MIO is an expandable input/output interface designed for use with Linears AM-3, AE-1000, & AE-2000 access control systems. Housed in a lockable cabinet, the basic AM-MIO consists of two modules: a power supply module (PSM) and a relay/loop module (RLM). Up to three additional RLM modules can be added to ll the ve-position module rack. Each RLM module provides six Form C (normally open & normally closed) 5-amp relays for outputs and eight supervised loop terminals for inputs. With four RLM modules, the AM-MIO is capable of controlling 24 relay outputs and 32 loop inputs. Each module has a rotary switch to select its unique remote device address. The device address identies each module to the system. Each module is interconnected to the controller by daisy-chained cables. Pushbuttons on the RLM module are provided for manually triggering each relay for testing. Each relay has a red LED light to show when its energized. A two-color red/ green LED on the RLM module displays the status of the loop inputs. If all eight loops are normal (not shorted or open) the indicator is green. If any of the eight loops are abnormal (shorted or open) the indicator is red. The power supply module distributes power to the RLM module(s). An external 16 VAC transformer powers the supply and provides charging current for a 12-volt backup battery (up to 7 amp/hour capacity). Indicators on the power supply module display its status. The green indicator lights when AC power is present and blinks when AC power is absent. The yellow indicator lights when the backup battery is low. Special power circuitry prevents fully discharging the backup battery. The status of the power supply is checked regularly by the controller. The red DATA indicator lights when data transfers. The red TAMPER indicator lights and the controller is signaled when the optional magnetic tamper switch detects that the cabinet has been opened.

CABINET COMPONENTS
POWER SUPPLY MODULE (PSM)

RELAY/LOOP MODULES (RLM) (FOUR MODULES MAXIMUM)

MODULE MOUNTING RACKS

Installation Instructions

(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com

BACKUP BATTERY 12 VOLT 7 AMP/HOUR MAXIMUM (NOT INCLUDED)

NOTE: ILLUSTRATION SHOWS FOUR RELAY/LOOP MODULES, ONLY ONE MODULE IS INCLUDED WITH THE AM-MIO

MODULE FEATURES
LOOP STATUS INDICATOR
DEVICE ADDRESS SELECTOR
MODULE CONNECTORS

KEY LOCK INSTALLATION (OPTIONAL)


RELAY/LOOP MODULE (RLM)
RELAY OUTPUT TERMINALS LOOP INPUT TERMINALS

REMOVING MODULES
1
CAREFULLY ROUTE THE BATTERY LEADS UNDER MODULE RACK AS SHOWN

RELAY STATUS INDICATORS

PLACE COVER ON CARPET AND PUNCH OUT KEY LOCK KNOCKOUT

RELAY TRIGGER PUSHBUTTONS

DEVICE ADDRESS SELECTOR


POWER SUPPLY STATUS INDICATORS DATA
TAMPER LOW BATTERY AC POWER

BACKUP BATTERY LEADS POWER SUPPLY MODULE (PSM)

PSM

RLM

2
POWER TERMINALS AUXILIARY PBUS TERMINALS

SLIDE MODULES OUT OF THE RACK

INSERT LOCK INTO COVER

MODULE TAMPER CONNECTOR SWITCH CONTROLLER CONNECTOR CONNECTOR

TIGHTEN NUT

MOUNTING CABINET
FOR CONDUIT WIRING, REMOVE ANY CABINET KNOCKOUTS BEFORE MOUNTING THE CABINET

SETTING DEVICE ADDRESSES


NOTE: PSM DEFAULT ADDRESS IS "5"

CONNECTING MODULES
CONNECT POWER SUPPLY TO RELAY/LOOP MODULE WITH THE 10-WIRE CABLE

USE THE CABINET BOTTOM AS A TEMPLATE TO MARK THE FOUR KEYHOLE MOUNTING HOLES

SET EACH MODULE TO A DIFFERENT DEVICE ADDRESS (ONLY REQUIRED IF ADDRESS OTHER THAN DEFAULT IS DESIRED)

FOR RECESSED WIRING, MARK WIRING SLOT, THEN CUT OUT HOLE WITH DRYWALL SAW USE THE APPROPRIATE HARDWARE TO MOUNT THE CABINET

THE ARROW IN THE SELECTOR SWITCH SLOT POINTS TO THE ADDRESS NUMBER (ADDRESS NUMBERS 1-6 ARE VALID)

NOTE: RLM DEFAULT ADDRESS IS "4"

RELAY/LOOP MODULE

POWER SUPPLY MODULE

INSTALLING MODULES
1
TO KEEP THE BATTERY LEADS AWAY FROM THE POWER SUPPLY HEAT SINK, ROUTE THE BATTERY LEADS UNDER MODULE RACK AS SHOWN

CONNECTING TAMPER SWITCH (OPTIONAL)


1
REMOVE THE OPTIONAL JUMPER FROM THE TAMPER SWITCH CONNECTOR

CONNECT TO ACCESS CONTROLLER

PSM

RLM

INSTALL THE TAMPER SWITCH IN THE BOTTOM CORNER OF CABINET AND CONNECT THE WIRE TO THE TAMPER SWITCH CONNECTOR

TO AM-MIO PSM

2
SLIDE MODULES INTO RACK

3
PRESS THE MODULES IN UNTIL THEY SNAP INTO PLACE

PLUG CABLE FROM AM-MIO PSM CONTROLLER CONNECTOR INTO THE CONTROLLER'S AM-MIO INTERFACE CONNECTOR (MODEL AM-3 CONTROLLER SHOWN)

ATTACH THE MAGNET TO THE CABINET COVER SO IT WILL ALIGN WITH THE TAMPER SWITCH WHEN THE COVER IS CLOSED

OPTIONAL: USE THE PSM AUXILIARY PBUS TERMINALS TO CONNECT TO THE CONTROLLER'S AUXILIARY PBUS TERMINALS. REFERENCE THE PSM WIRING DIAGRAM. CABLE TYPE IS BELDEN 9931 (300 FEET MAX. CABLE RUN) OR WEICO 9405 (500 FEET MAX. CABLE RUN).

CONNECT RELAY OUTPUTS


CONNECT RELAY OUTPUTS TO THE CONTROLLED DEVICES RELAY RATING: 5 AMPS @ 14 VDC MAXIMUM

CONNECT LOOP INPUTS


CONNECT ANY INPUTS TO THE LOOP INPUT TERMINALS EACH LOOP INPUT CAN BE TRIGGERED WITH A NORMALLY OPEN OR NORMALLY CLOSED SWITCH ALL LOOP INPUTS MUST BE TERMINATED WITH A 2.2K END-OF-LINE RESISTOR
LOOP 1 1 COM 2 LOOP 2 3 LOOP 3 4 COM 5 LOOP 4 6

CONNECT AC POWER
CONNECT 16 VAC POWER FROM PLUG-IN TRANSFORMER TO POWER TERMINALS 1&2 CONNECT A GOOD EARTH GROUND TO POWER TERMINAL 3

CHANNEL 1
1 N.O. 2 COM 3 N.C. 4

CHANNEL 2
5 COM 6 N.C. 7

CHANNEL 3
8 COM 9 N.C.

EXAMPLE OF LOOPS 1-4 WITH NORMALLY CLOSED SWITCHES

POWER TERMINALS

2.2K
LOOP 5 7

2.2K
LOOP 6 9

2.2K
LOOP 7 10

2.2K
LOOP 8 12

N.O.

N.O.

COM 8

COM 11

16 VAC, 24 VA MIN. POWER TRANSFORMER

AC IN 1

AC IN 2

CHANNEL 4
10 N.O. 11 COM 12 N.C. 13

CHANNEL 5
14 COM 15 N.C. 16

CHANNEL 6
17 COM 18 N.C.

NOTE: DATA GROUND TERMINAL IS USED ONLY EARTH DATA WHEN CONNECTING GND GND TO THE CONTROLLER 3 4 THROUGH THE CONTROLLER AUXILIARY PBUS TERMINALS

N.O.

N.O.

EXAMPLE OF LOOPS 5-8 WITH NORMALLY OPEN SWITCHES

2.2K

2.2K

2.2K

2.2K

UNIFIED EARTH GROUND

CONNECT BACKUP BATTERY


PLACE THE BACKUP BATTERY IN THE CABINET

TEST RELAYS
CAUTION! DEVICES CONNECTED TO THE RELAYS WILL ACTIVATE
THE RELAY STATUS INDICATOR WILL LIGHT WHEN THE RELAY IS ENERGIZED

TEST LOOPS
WATCH THE LOOP STATUS INDICATOR WHILE TESTING THE LOOPS GREEN = ALL LOOPS NORMAL RED = ANY LOOP OPEN OR SHORTED

CONNECT THE RED LEAD TO BATTERY POSITIVE (+) CONNECT THE BLACK LEAD TO BATTERY NEGATIVE (-)

PRESS THE RELAY TRIGGER BUTTONS TO TEST EACH RELAY CONNECTED

WIRING DIAGRAM
AM-MIO PSM WIRING DIAGRAM
+ RED WIRE
AC IN AC IN EARTH DATA GND GND

AM-MIO RLM WIRING DIAGRAM


RELAY OUTPUT TERMINALS
CHANNEL 1 COM N.C. N.O.
CHANNEL 2 N.O. COM N.C. CHANNEL 3 N.O. COM N.C.
LOOP 1

- BLACK WIRE

POWER TERMINALS

LOOP INPUT TERMINALS


COM LOOP 2 LOOP 3 COM LOOP 4

16 VAC, 24 VA MINIMUM TRANSFORMER

12 VDC BACKUP BATTERY


EARTH GROUND STAKE
PCLK

CONTROLLED DEVICE "1"

CONTROLLED DEVICE "2"

CONTROLLED DEVICE "3"

2.2K

2.2K

2.2K

2.2K

DAT1

AUXILIARY PBUS TERMINALS


DAT0 DVAL

POWER SUPPLY RELAY/LOOP MODULE (PSM) MODULE (RLM)


CHANNEL 4 N.O. COM N.C. 10
11

ALL LOOP INPUTS MUST BE TERMINATED WITH A 2.2K END-OF-LINE RESISTOR

RELAY OUTPUT TERMINALS


CHANNEL 5 N.O. COM N.C.
13

LOOP INPUT TERMINALS


CHANNEL 6 N.O. COM N.C.
16
LOOP 5 COM LOOP 6 LOOP 7 COM LOOP 8

12

14

15

17

18

10

11

12

CONTROLLER PBUS TERMINALS

TEST SYSTEM

NOTE: OPTIONAL AM-MIO PSM TO CONTROLLER WIRING SHOWN WHEN NOT USING THE INCLUDED CABLE

CONTROLLED DEVICE "4"

CONTROLLED DEVICE "5"

CONTROLLED DEVICE "6"

2.2K

2.2K

2.2K

2.2K

LINEAR LIMITED WARRANTY


This Linear product is warranted against defects in material and workmanship for twenty four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linears normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealers warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or prot, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Service at 1-800421-1587 for an RPA# and other important details.

IMPORTANT !!!
Linear radio controls provide a reliable communications link and ll an important need in portable wireless signalling. However, there are some limitations which must be observed. For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. Changes or modications to the device may void FCC compliance. Infrequently used radio links should be tested regularly to protect against undetected interference or fault. A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

1. PROGRAM THE ACCESS CONTROL SYSTEM. BE SURE TO PROGRAM THE SYSTEM FOR THE DEVICE ADDRESS OF EACH OF THE AM-MIO MODULES. 2. USE ENTRY CODES OR TRANSMITTERS TO TEST ACTIVATE EACH OF THE AM-MIO OUTPUTS 3. TEST TO SEE IF EACH OF THE AM-MIO LOOP INPUTS (IF USED) ARE RECOGNIZED BY THE ACCESS CONTROL SYSTEM

Copyright 2004 Linear LLC

218307 B