NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES (mm) UNLESS OTHERWISE NOTED. 2. THE ARCHITECTURAL BACKGROUNDS ARE DRAWN TO SCALE HOWEVER MEP SYMBOLS & DATA ARE NOT NECESSARILY DRAWN TO SCALE. IF IN DOUBT, REQUEST FURTHER INFORMATION. 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH THE MAIN CONTRACT CONDITIONS, THE BUILDING SERVICES SPECIFICATIONS AND SCHEDULES, AND ALL OTHER CONTRACT DOCUMENTATION.

4. REFER TO THE ARCHITECTS DRAWINGS FOR DETAILS OF ALL SETTING OUT

s
s s

STANDARD SWITCH (g = No. OF GANGS)

a. b.kva c.V d.P e.W f.

EQUIPMENT CALLOUT a. EQUIPMENT DESIGNATION b. EQUIPMENT LOADING IN KVA c. EQUIPMENT VOLTAGE d. NUMBER OF POLES e. NUMBER OF WIRES

CCTV

1 X RJ45 JACK FOR CCTV CAMERA ON SECURITY NETWORK

CONTAINMENT SIZES AS INDICATED ON DRAWINGS. CCTV CAMERA DOME STATIC

BREAK GLASS UNIT BREAK GLASS UNIT POINT FOR SMOKE VENT

AFFL - ABOVE FINISHED FLOOR LEVEL AHU - AIR HANDLING UNIT ASP - ASPIRATING UNIT ATS - AUTOMATIC TRANSFER SWITCH

SCS - STRUCTURED CABLING SYSTEM

INFORMATION. NO DIMENSIONS SHALL BE MEASURED FROM THIS DRAWING.

3 WAY SWITCH (g = No. OF GANGS)

SB - SMART BOARD (AV)

5. REFER TO THE ARCHITECTS REFLECTED CEILING PLANS (HA-161617-083 TO 155 & 161633-001, 002, 003 & 005) FOR THE SETTING OUT OF ALL SOFFIT MOUNTED SERVICES COMPONENTS.

3 g

DC

1 X RJ45 JACK FOR DOOR CONTROLLER ON SECURITY NETWORK

STRUCTURED CABLING BASKET (DOUBLE LINE) SUB-MAINS CABLE LADDER SUB-MAINS CABLE TRAY CCTV CAMERA PTZ SECURITY BASKET ELV CABLE TRAY PAVA TRAY CCTV CAMERA PTZ WITH INFRARED STRUCTURED CABLING BASKET FIRE ALARM CABLE TRAY M (UNLESS OTHERWISE NOTED) CCTV MONITOR D CCTV CAMERA STATIC WITH INFRARED CCTV CAMERA DOME PTZ

K KEY OPERATED BREAK GLASS UNIT

4 WAY SWITCH (g = No. OF GANGS)

4 g

W2

2 X RJ45 JACKS MOUNTED FLUSH ON WALL @ 380mm FOR GENERAL PURPOSE

6. REFER TO THE ARCHITECTS DRAWINGS FOR DETAILS OF ALL BUILDING SEC - SECURITY COMPARTMENTATION. ALL SERVICES SHALL BE FIRE STOPPED USING THE APPROVED PENETRATION DETAILS, FULLY IN ACCORDANCE WITH THE COMPARTMENT RATING. SF - SUPPLY FAN 7. THE CONSTRUCTION CONTRACTOR SHALL PROVIDE CO-ORDINATED INSTALLATION SS - SCENE SETTING DRAWINGS FOR REVIEW AND PRIOR TO INSTALLATION ON SITE AS DEFINED IN CONTRACT PRELIMS. THE CONSTRUCTION CONTRACTOR SHALL BE RESPONSIBLE FOR T/C - TIME CLOCK VERIFYING ALL ROUTES SHOWN AND MODIFY WHERE NECESSARY ON THE INSTALLATION DRAWINGS PRIOR TO COMMENCING INSTALLATION ON SITE. ALL TA - TO ABOVE INFORMATION SHALL BE ISSUED IN A TIMELY MANNER TO ALLOW THE REVIEW AND APPROVAL PROCESS WITHOUT AFFECTING THE CONSTRUCTION SCHEDULE. T-B - TOP TO BOTTOM 8. THE CONTRACTOR SHALL CARRY OUT ALL WORKS, SYSTEMS, ETC. TO A METHOD, STANDARD AND SCHEDULE APPROVED BY THE COMPANY.

CCTV CAMERA STATIC

s
s

DIMMER SWITCH (g = No. OF GANGS)

f. RELEVANT NOTES

HEAT DETECTOR AV - AUDIO VISUAL

D # p g

PULLCORD SWITCH (# = No. OF GANGS) DUPLEX RECEPTACLE, 20A, 12OV

W3

3 X RJ45 JACKS MOUNTED FLUSH ON WALL @ 380mm FOR GENERAL PURPOSE

Co

CARBON MONOXIDE DETECTOR

AWG - AMERICAN WIRE GAUGE CE - CONTROLS ENCLOUSURE CL - CLEANERS

COMBINED HEAT/SMOKE DETECTOR

s
s s

KEY SWITCH (g = No. OF GANGS) QUAD RECEPTACLE, 20A, 12OV W4 4 X RJ45 JACKS MOUNTED FLUSH ON WALL @ 380mm FOR GENERAL SCENE SETTING SWITCH (# = No. OF SCENES) J JUNCTION BOX WT 1500 WATER PROOF SWITCH (g = No. OF GANGS) SB SPLITTER BOX 2 X RJ45 JACKS MOUNTED FLUSH ON WALL @ 1500mm FOR TELEPHONY & OTHER PURPOSE

COMBINED HEAT/SMOKE DETECTOR WITHIN VOID

ss g

CCTV - CLOSED CIRCUIT TELEVISION (SECURITY) A FV A ASPIRATING POINT WITHIN FLOOR VOID CV A DT LR DUAL TECHNOLOGY PIR DETECTOR LONG RANGE PIR DETECTOR S DUCT SMOKE DETECTOR C/W REMOTE LAMP DTB - DROP TO BELOW E - EMERGENCY EF - EXTRACT FAN UPS - UNINTERRUPTIBLE POWER SUPPLY ASPIRATING POINT WITHIN CEILING VOID DFA - DROP FROM ABOVE TVSS - TRANSIENT VOLTAGE SURGE PROTECTION D - DIMMABLE ASPIRATING POINT CV - CEILING VOID TB - TO BELOW

WP g

RL

LIGHTING/POWER/RECEPTACLE PANEL

WAV 1500

AS ABOVE BUT FOR DISPLAY (AV) EQUIPMENT E.G. DIGITAL SIGNAGE SCREEN OR INTERACTIVE WHITEBOARD

DISTRIBUTION BOARD BOUNDARY WALL MOUNTED RACEWAY C/W RECETACLES AS INDICATED

DC - DOOR CONTROLLER (SECURITY)

TEF - TOILET EXTRACT FAN

ARAMCO STANDARDS. PLEASE REFER TO DRAWINGS HA-162371-001, HA-162372-001 & 002 & HA-162373-001 AND ALL MEP SPECIFICATIONS WHICH DETAILS THE SPECIFIC SAUDI ARAMCO STANDARDS APPLICABLE TO EACH MEP DISCIPLINE. 10. THE DESIGN DRAWINGS DO NOT NECESSARILY SHOW ALL COMPONENTS WHICH MAY

s
PD

MOMENTARY PUSH BUTTON (g = No. OF GANGS) MAIN LV SWITCH PANEL WL PRESENCE DETECTOR MECHANICAL CONTROL CENTRE (MCC)

PB

2 X RJ45 JACKS CEILING MOUNTED FOR WIRELESS ACCESS POINT

CABLE BUS ROUTE

PD LR

DT LONG RANGE PRESENCE DETECTOR HD PHOTO ELECTRIC CELL FH EMERGENCY EXIT SIGN. ARROWS AS INDICATED FAN HEATER F2 2 X RJ45 JACKS MOUNTED IN FLOOR BOX FOR GENERAL USE CONTAINMENT SIZES AS INDICATED ON DRAWINGS. WH WATER HEATER F3 3 X RJ45 JACKS MOUNTED IN FLOOR BOX FOR GENERAL USE HALOGEN TWIN SPOT EMERGENCY LUMINAIRE C/W 3 HOUR. BATTERY DURATION. F4 PSU POWER SUPPLY UNIT 4 X RJ45 JACKS MOUNTED IN FLOOR BOX FOR GENERAL USE 3 COMPARTMENT RACEWAY TRUNKING C/W PRESETS AT SPECIFIED CENTRES L2 L3 CR1 RACEWAY RISER CR2 3 COMPARTMENT RACEWAY JUNCTION BOX C/W SQUARE COVER PLATE # CR3 GBU RTE MC FLOOR SOCKET. # DENOTES FLOOR SOCKET TYPE FM OUTLET SB GROUND FAULT SENSOR TV TV OUTLET G
AS

EXTERNAL DUAL TECHNOLOGY PIR DETECTOR EXTERNAL LONG RANGE PIR DETECTOR

C2 HAND DRYER

2 X RJ45 JACKS CEILING MOUNTED FOR GENERAL PURPOSE USE LR

Rx

BEAM SMOKE DETECTOR RECEIVER

VA - VOICE ANNUNCIATION

BE REQUIRED TO FORM A COMPLETE INSTALLATION. THE CONTRACTOR SHALL PROVIDE ALL ACCESSORIES AND FITTINGS AS NECESSARY FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH THE MEP SPECIFICATIONS. 11. REFER TO DRAWING HA-162371-001 FOR ALL HVAC SYMBOLS, ABBREVIATIONS AND

PC

ELV - EXTRA LOW VOLTAGE ( = 50V ac OR 120V DC) INTERNAL SECURITY SOUNDER BEAM REFLECTOR EO - ELECTRICALLY OPERATED EXTERNAL SECURITY SOUNDER 3 COMPARTMENT RACEWAY TRUNKING L1 MAG LOCK SOLENOID BOLT Co SHEAR LOCK THUMB/PIN/PROXIMITY READER D PIN/PROXIMITY READER PROXIMITY CARD READER H GREEN BREAK GLASS UNIT REQUEST TO EXIT Co MAGNETIC DOOR CONTACT DOOR CONTROLLER D SLAB BOX. # DENOTES SLAB BOX TYPE LC I IH LIFT CONTROLLER INTERCOM CALL POINT INTERCOM RECEIVE POINT ALARM KEYPAD REMOTE INPUT/OUTPUT RADIO FREQUENCY IDENTIFICATION RECEIVER RFID RECEIVER HUB UNIT INT INTERFACE MODULE JB - JUNCTION BOX LTG - LIGHTING LL - LOW LEVEL LP - LIGHTING PANEL L-R - LEFT TO RIGHT LR - LONG RANGE SMS SECURITY MANAGEMENT SYSTEM SECURITY MANAGEMENT SYSTEM SERVER OVERDOOR VISUAL INDICATOR FAP FIRE ALARM PANEL Co COMBINED CARBON MONOXIDE DETECTOR, SOUNDER & BEACON ICT - INFORMATION COMMUNICATION TECHNOLOGY IL - INDUCTION LOOP H COMBINED CARBON MONOXIDE DETECTOR & BEACON GFI - GROUND FAULT INTERRUPTER DC COMBINED HEAT/SMOKE DETECTOR, SOUNDER & BEACON COMBINED HEAT DETECTOR, SOUNDER & BEACON HV - HIGH VOLTAGE (> 1000V) GND - GROUND HL - HIGH LEVEL COMBINED HEAT DETECTOR & BEACON FLC - FULL LOAD CURRENT FV - FLOOR VOID COMBINED CARBON MONOXIDE DETECTOR & SOUNDER FB - FROM BELOW FCU - FAN COIL UNIT FFL - FIXED FLOOR LEVEL H COMBINED HEAT DETECTOR & SOUNDER FA - FIRE ALARM FA - FROM ABOVE D COMBINED HEAT/SMOKE DETECTOR & SOUNDER EWH - ELECTRIC WATER HEATER

WP - WEATHERPROOF

STANDARD HVAC NOTES. 12. REFER TO DRAWINGS HA-162372-001 & 002 FOR ALL ELECTRICAL SYMBOLS, ABBREVIATIONS AND STANDARD ELECTRICAL NOTES.

EXIT

ON DRAWINGS. TWO ARROWS INDICATE DOUBLE SIDED SIGN.

XFR - TRANSFORMER

ZCV - ZONE CHECK VALVE 13. REFER TO DRAWING HA-162373-001 FOR ALL PLUMBING & FIRE PROTECTION SYMBOLS, ABBREVIATIONS & STANDARD PLUMBING & FIRE PROTECTION NOTES.

ELECTRIC FAN

MS

DAYLIGHT AND OCCUPANCY MULTI SENSOR CAV 2 X RJ45 JACKS CEILING MOUNTED FOR A.V. EQUIPMENT E.G. PROJECTOR.

MW

CEILING MOUNTED MICROWAVE OCCUPANCY SENSOR

UPS

UNINTERRUPTIBLE POWER SUPPLY

COMBINED HEAT/SMOKE DETECTOR & BEACON

LCP

LIGHTING CONTROL PANEL XFR STEP DOWN TRANSFORMER F0 DRAWOUT CONNECTION DUPLEX 5m FIBRE OPTIC OUTLET FOR FUTURE USE. JB

LIGHTING DESIGNATIONS FOR ALL LUMINAIRES

FB
MOULDED CASE CIRCUIT BREAKER

FLOOR BOX. # DENOTES FLOOR BOX TYPE #

AUDIO VISUAL
FM

FS

"ASO1"

INDICATES LUMINAIRE TYPE 1. FIRST LETTER INDICATES AREA OF BUILDING 2. SECOND LETTER INDICATES IF LUMINAIRE IS SURFACE MOUNTED (S), RECESSED (R), SUSPENDED OR PENDANT (P). TRANSFORMER SOLIDLY GROUNDED #

FLOOR GROMMET

"E"

DENOTES LUMINAIRES C/W 3 HOUR BATTERY PACK. E.G. AS01E REFER TO LUMINAIRE SCHEDULE XXXXXXX FOR FULL LUMINAIRE SPECIFICATION. REFER TO ARCHITECTURAL DRAWINGS AND

AMMETER SWITCH

SAT

SATELLITE/CABLE TV OUTLET

ACCESSIBLE TOILET ALARM


VS

KP RIO RFID

VOLTMETER SWITCH

FTS

FM/TV/SAT TRIPLEX OUTLET

SYSTEMS

REFERENCE DRAWINGS DWG. CONTROL FOR J.O. 10-07575-0001 MECHANICAL STANDARD SYMBOL SHEET ELECTRICAL STANDARD SYMBOL SHEET PUBLIC HEALTH STANDARD SYMBOL SHEET HD 161614 001 HA 162371 001 HA 162372 001 HA 162373 001

50

PULLCORD SWITCH AMPLIFIER R RESET UNIT

ASO1 LUMINAIRE. SURFACE MOUNTED, RECESSED OR SUSPENDED ASO1 FLUORESCENT BATTON LUMINAIRE. SURFACE OR SUSPENDED AS01 CIRCULAR LUMINAIRE. SURFACE MOUNTED, RECESSED OR SUSPENDED AS01 WALL MOUNTED LUMINAIRE. SURFACE MOUNTED OR RECESSED GROUNDING
G R A

AMBER INDICATING LAMP (BREAKER TRIP) RED INDICATING LAMP (BREAKER CLOSED) GREEN INDICATING LAMP (BREAKER OPEN)

PA1

FLUSH MOUNTED CEILING LOUDSPEAKER. 135 MM CIRCULAR WHITE EPOXY COATED METAL GRILLE DAP DAR DISABLED ALARM CONTROL PANEL DISABLED ALARM REPEATER PANEL

VR SAP V-IP NVR UPS

VIDEO RECORDER SECURITY ALARM PANEL

FARP SS

FIRE ALARM REPEAT PANEL SYSTEM STATUS INDICATOR PANEL ELECTRO MAGNETIC DOOR RELEASE RELAY PANEL

VIDEO IP ENCODER NETWORK VIDEO RECORDER UNINTERRUPTABLE POWER SUPPLY POWER SUPPLY UNIT PATCH PANEL SCI EQUIPMENT RACK SHORT CIRCUIT ISOLATOR M - MECHANICAL PLANT
MAKKAH
S65^45W

PA2

FLUSH MOUNT 2-WAY COAXIAL CEILING LOUDSPEAKER. 265 MM CIRCULAR PURE WHITE METAL GRILLE

EDR RP

LOCATION REFERENCE:

FUSE PA3 POTENTIAL TRANSFORMER PA4 CURRENT TRANSFORMER PA5


A

DISABLED REFUGE SYSTEMS


SURFACE MOUNTED WALL LOUDSPEAKER DRAP BIDIRECTIONAL SURFACE MOUNTED WALL SPEAKER DRI DISABLED REFUGE INTERCOM DISABLED REFUGE ALARM PANEL

PSU DPP

ASPIRATOR SAMPLING DETECTION SYSTEM

LV - LOW VOLTAGE (<1000V)

MCC - MOTOR CONTROL CENTRE CCTV MOUNTING COLUMN MEDIA CONVERTER BUZZER

FIRE INDICATORS

MO - MECHANICALLY OPERATED MP - MECHANICAL PANEL NC - NORMALLY CLOSED

15WATT COLUMN LOUDSPEAKER

AMMETER PA6 30WATT COLUMN LOUDSPEAKER

LIGHTNING PROTECTION
LIGHTNING PROTECTION AIR FINIAL

NETWORK SWITCH ELECTRIC BELL PANIC ALARM BUTTON PERSONAL ATTACK BUTTON VBCP VBCU ERP VEHICLE BLOCKER CONTROL POINT (CONTROL ROOM) VEHICLE BLOCKER CONTROL UNIT (AT BLOCKER) EQUIPMENT RECHARGING POINT VIDEO WALL COMPUTER WORKSTATION VISUAL DISPLAY UNIT VIDEO TRANSCEIVER PANEL POWER SUPPLY INTEGRATOR CAMERA BALUN ADVANCED CENTRAL CONTROLLER (ACS) HVM BOLLARD FIXED HQ HIGH QUALITY BI-DIRECTIONAL VOICE ALARM LOUD SPEAKER FIRE ALARM SOUNDER HVM BLOCKER AUTOMATED S VOICE ALARM LOUD SPEAKER S INDICATES SURFACE MOUNTED CBAL R VOICE ALARM LOUD SPEAKER. R INDICATES RECESSED SPEAKER. W EXTERNAL BELL & BEACON

VOLTMETER PA7 SOLID STATE TRIP UNIT 50WATT COLUMN LOUDSPEAKER P BOND (Notation: S - STRUCTURE/STEEL P - PLANT) IC INTERCOM STATION COMMUNICATION

REMOTE LED INDICATOR PA - PUBLIC ADDRESS FIRE ALARM SIREN PP - POWER PANEL XENON FLASHING BEACON/STROBE PR - PROJECTOR (AV) F FIRE TELEPHONE CALL POINT R/L - RAISE/LOWER RFB - RISE FROM BELOW

LT ST GF SST

LONG TIME SHORT TIME GROUND FAULT

EARTH TERMINATION POINT

CLOCK/TIMER
PFC

VW

SATELLITE DIGITAL MULTI-METER. AS A MINIMUM V,


M

FP TV TELEVISION FLY V VOLUME CONTROL PS AERIAL

EXTERNAL SERVICES FEEDER PILLAR

VDU VTP

A, FREQ, KVA, KW, PF, KWH, MAX DEMAND.

INSECT CONTROL UNIT

PSI

RIO - REMOTE INPUT / OUTPUT UNIT (SECURITY) RMC - RIGID METAL CONDUIT RTA - RISE TO ABOVE

VACUUM CIRCUIT BREAKER PUMPING STATION

SPEAKER.

AIR CIRCUIT BREAKER PA


RT

REMOTE TRIP UNIT VARP VA RELAY PANEL CT RATED TRAFFIC ISLAND / DIVIDER

1.0

2.0

3.0

4.0

5.0

10.0

FIRE ALARM SOUNDER/BEACON


METERS

L N

AUTOMATIC TRANSFER SWITCH


E

NTS

SP NON-FUSEABLE (2 POLE) SWITCH DISCONNECT AA AUDIO ATTENUATOR

TRAFFIC CONTROL LIGHTS RISING ARM BARRIER HVM RISING ARM BARRIER PA CHANGEOVER PANEL
MC

W T D

WHITE STROBE BEACON PANIC DUCT TEST STATION

SCALE:

TP NON-FUSEABLE (3 POLE) SWITCH DISCONNECT SP (2 POLE) FUSED SWITCH DISCONNECT

REVISION VALIDATION

AUTO DIALLER
THIS REVISION NO.

HEAVY DUTY MAGNETIC CONTACT EOL TOUCH SCREEN SCENE SELECT PANEL SYM ANN DH SYNCHRONISATION MODULE ANNUNICIATOR FIRE ALARM DOOR HOLD FIRE ALARM RELAY FIRE ALARM END OF LINE RESISTOR

00

IS COVERED, FOR ALL APPROVAL AND CERTIFICATION

SS

10-07575-0001-001
DESIGN CERTIFICATION
(DESIGN AGENCY)
ENGG./DATE

TP (3 POLE) FUSED SWITCH DISCONNECT

Pm

AV PROJECTOR - MOBILE UNIT

REVIEW FOR KEY DRAWINGS


x REQUIRED (SAUDI ARAMCO)
OPERATIONS/DATE

OTHER

CERTIFIED BY/DATE CONST. AGENCY/DATE

BY/DATE

J
2

JUNCTION BOX FOR DOOR CONTROLLER

AV PROJECTION SCREEN IN CEILING VOID R

SGC 04/15/10
REV.NO. DATE

GRH 04/15/10
REVISION DESCRIPTION

NAH 04/15/10

FFT 04/15/10

JUNCTION BOX FOR COMBINED FIRE/SMOKE DAMPER

AV PROJECTION SCREEN - MOBILE UNIT

00

04/15/10

IFC

JOB ORDER/EWO NO. THIS REVISION IS NOT TO BE USED FOR

10-07575-0001

CONSTRUCTION UNTIL CERTIFIED AND DATED

DRAWING TYPE

ELECTRICAL PLAN/LAYOUT/DETAIL ELECTRICAL SYMBOLS LIST K.A.C.K.C (ITHRA) DHAHRAN


PLANT NO. INDEX

EDT

SAUDI ARABIA
DRAWING NUMBER
SHT. NO. REV. NO.

H75

HA-162372 001 00
Saudi Aramco 2615 ENG. (05/05)

CONFIDENTIAL

VECTOR

CADD-01

THI S

DRAWI NG

AND

SAUDI ARABIAN OIL COMPANY

THE

I NFORMATI ON

AV PROJECTOR

TS

REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

CONTAI NED

AVP

AUDIO VISUAL PANEL

GROUND INDUCTION LOOP

BLUE STROBE BEACON PANIC

HEREI N

PUBLIC ADDRESS PANEL/RACK

HVM AUTOMATED RISING BOLLARD

ARE

ACC

THE

SOLE

POWER FACTOR CORRECTION

MISCELANEOUS

WS

PROPERTY

NO - NORMALLY OPEN

OF

SAUDIARAMCO.NO

REPRODUCTI ON

SPECIFICATIONS FOR MOUNTING HEIGHTS

GS

GROUND FAULT RELAY

LOUDSPEAKER

FIRE PANELS

IS - INTERACTIVE SCREEN (AV)

I N

FULL,OR

I N

PART,SHALL

BE

OBTAI NED

FROM

CONTAINMENT (UNDERFLOOR)

Tx

BEAM SMOKE DETECTOR TRANSMITTER

VAV - VARIABLE AIR VOLUME BOX

THI S

DRAWI NG

RAISE/LOWER SWITCH (g = No. OF GANGS)

SECURITY GENERAL

9. THESE GENERAL NOTES SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT SAUDI

WI THOUT

THE

WRI TTEN

SD - SECURITY DOOR

CONSENT

LIGHTING

POWER

ICT

CONTAINMENT (GENERAL)

SECURITY CCTV

FIRE DETECTORS

ABBREVIATIONS

OF

SAUDIARAMCO.