Sunteți pe pagina 1din 1

CORIOLIS MASS FLOWMETERS DATASHEET

Project : B193 FIELD DEVELOPMENT PROJECT

Document No. : B193(R)-DS-IN-4019A Sheet No. 1 of 1 Rev. Q1 Item / Tag No. AS LISTED BELOW Process Data Rev. :

10FT-2000 10FT-2005 1. Tag Number B193AP(R)-DR-PR-1314 B193AP(R)-DR-PR-13145 2. P&ID Number 10"-P-E1N-1129 10"-P-E1N-1129 3. Line No. Line Insulation 10" 120 10" 120 4. Line Size Schedule GENERAL MAIN OIL LINE PUMP MAIN OIL LINE PUMP 5. Service CLASS 1 , DIV. 1 , GROUP C & D , T3 CLASS 1 , DIV. 1 , GROUP C & D , T3 6. Area Classification INTRINSICALLY SAFE / WEATHERPROOF INTRINSICALLY SAFE / WEATHERPROOF 7. Enclosure Class TO IP 65 / NEMA 4X TO IP 65 / NEMA 4X 8. 9. SS 316L (NACE) SS 316L (NACE) 10. Sensor Material FLANGED SMOOTH FINISH FLANGED SMOOTH FINISH 11. End Connection Face Finish SS 316L (NACE) SS 316L (NACE) 12. End Connection Flange Material 600# , RF 600# , RF 13. Flange Rating and Facing (#) (#) 14. Sensor Nominal Bore Size SS 316L (NACE) SS 316L (NACE) 15. Sensor Spool Piece Material SS 316L (NACE) SS 316L (NACE) 16. Other Wetted Parts Material SS 316L (NACE) SS 316L (NACE) 17. Enclosure Material METER Note 5 Note 5 18. Measuring Range Note 5 Note 5 19. Adjustable Range 0.2% OF FLOW RATE 0.2% OF FLOW RATE 20. Accuracy (#) (#) 21. Sensitivity 0.2% 0.2% 22. Repeatability (#) (#) 23. Effect of Temperature (#) (#) 24. Minimum Detection Limit 25. 26. 24 VDC LOOP POWERED 24VDC LOOP POWERED 27. Power Supply 4 - 20 mA WITH LOCAL INDICATOR 4 - 20 mA WITH LOCAL INDICATOR 28. Output CLASS 1 , DIV. 1 , GROUP C & D , T3 CLASS 1 , DIV. 1 , GROUP C & D , T3 29. Electrical Area Class INTRINSICALLY SAFE , NEMA 4X / IP65 INTRINSICALLY SAFE , NEMA 4X / IP65 30. Enclosure TRANSMITTER SS 316 SS 316 31. Enclosure Material 1/2" NPTF 1/2" NPTF 32. Cable Entry FM / UL / BASEEFA / CSA / DGMS / CMRS FM / UL / BASEEFA / CSA / DGMS / CMRS 33. Certifications 34. 35. Units : FLOW (liquid) - m/hr FLOW (gas) - Nm/hr / PRESSURE - kg/cmg / TEMPERATURE - C 36. Fluid State Note 6 Note 6 37. Minimum Flow Note 6 Note 6 38. Normal Note 6 Note 6 39. Maximum Note 6 40. Inlet Pressure Operating Maximum Note 6 41. Temperature Operating Maximum kg/cm kg/cm kg/cm kg/cm SERVICE 42. S.G. at Oper. Temp. Molecular Weight CONDITIONS Note 6 Note 6 43. Design Pressure Note 6 cP Note 6 cP 44. Operating Viscosity (cP) Note 5 kg/cmg Note 5 kg/cmg 45. Max. Allowable Pressure Drop Across Meter Note 6 kg/m Note 6 kg/m 46. Density Note 6 Note 6 47. Maximum Water Content Note 6 Note 6 48. Normal Note 6 Note 6 49. Minimum 50. (#) (#) 51. Manufacturer OTHERS (#) (#) 52. Model No. 53. Notes : 1. All weldings shall be 100% radiographed. 2. All Wetted Parts Material shall comply with latest edition of NACE MR 01-75 requirement. 3. Flange Facing shall be Smooth Finish 125 to 250 microinch AARH. 4. Vendor shall advise required straight run for each flowmeter. 5. Vendor to advise. 6. Refer to Process Data

(#) - VENDOR TO ADVISE. REV DATE DESCRIPTION MADE BY CHECKED BY APPROVED BY

Q1

19/09/08

Issued For Enquiry (IFE)

MHN

PMM

PMM

S-ar putea să vă placă și