Sunteți pe pagina 1din 2

CT - Oil Current Transformer

115 kV

Trench proposal #... M12Z-1120-50

Item #...

Quantity..................................................... 6
Product type............................................. IOSK 123
Standard................................................... IEC 60044-1
Maximum altitude........ 1000 m
Ambient temperature..... 0 C to +45 C
Rated voltage (between phases)..............
Maximum voltage (between phases)........
Frequency.......................................
Power frequency withstand voltage dry.....
Power frequency withstand voltage wet...
Lightning impulse withstand voltage (BIL)
Switch impulse withstand voltage to earth
Rated primary current...............................
Rated continuous thermal current factor..
Thermal short time current ......................
Dynamic short time current.......................
Ratio.........................................................
Ratio change mean..................................
- Core 1,
- Core 2,3,4

115
123
50
230
230
550
N/A
800
1.2
31.5
63

kV
kV
Hz
kV
kV
kV
kV
A
In
kA rms /3 sec
kA peak

200-400-600-800/1-1-1-1
Secondary taps
0.2
30VA
@ all ratio
5P20
30VA @ all ratio

Porcelain insulator..................................... Brown


Creepage distance.................................
3075 mm
1200 mm
Flashover distance....................................
Primary terminal.........................................
Primary connector..................................
Grounding terminal.................................
Grounding connector.................................
Secondary terminals..

Aluminum NEMA 4 holes


Not supplied
Aluminum flat pad 2 holes
Not supplied
Terminal blocks Phoenix OTTA6

Dimensions as per drawing......................

0MWB.99A.662

- Lifting lugs
- Oil indicator (bellows position indicator)
- Secondary terminal box - cable lead ingress sealed by a removable plate
- Stainless Steel Name plate and Connection diagram plate
- Oil sampling valve

Page 1 of 2

CT - Oil Current Transformer

35 kV

Trench proposal #... M12Z-1120-50

Item #...

Quantity..................................................... 2
Product type............................................. IOSK 40.5
Standard................................................... IEC 60044-1
Maximum altitude........ 1000 m
Ambient temperature..... 0 C to +45 C
Rated voltage (between phases)..............
Maximum voltage (between phases)........
Frequency.......................................
Power frequency withstand voltage dry.....
Power frequency withstand voltage wet...
Lightning impulse withstand voltage (BIL)
Switch impulse withstand voltage to earth
Rated primary current...............................
Rated continuous thermal current factor..
Thermal short time current ......................
Dynamic short time current.......................
Ratio.........................................................
Ratio change mean..................................
- Core 1,

35
40.5
50
70
70
170
N/A
30
1.2
25
63

kV
kV
Hz
kV
kV
kV
kV
A
In
kA rms /3 sec
kA peak

30/1
Secondary taps
5P20
30VA

@ all ratio

Porcelain insulator..................................... Brown


Creepage distance.................................
1256 mm
700 mm
Flashover distance....................................
Primary terminal.........................................
Primary connector..................................
Grounding terminal.................................
Grounding connector.................................
Secondary terminals..

Aluminum NEMA 4 holes


Not supplied
Aluminum flat pad 2 holes
Not supplied
Terminal blocks Phoenix OTTA6

Dimensions as per drawing......................

0MWB.99A.670

- Lifting lugs
- Oil indicator (bellows position indicator)
- Secondary terminal box - cable lead ingress sealed by a removable plate
- Stainless Steel Name plate and Connection diagram plate
- Oil sampling valve

Page 2 of 2