Sunteți pe pagina 1din 1

Solar Power

Solarrouter On-grid Inverter with Energy Storage


2KW/4.5KW/5KW on-grid inverter with energy storage Pure sinewave output Microprocessor controlled to guarantee stable charging system Multiple operations: Grid tie, Off grid, and grid-tie with backup Built-in MPPT solar charger LCD display panel for comprehensive information Multiple communication Green substitution for generators User-adjustable battery charging current

Solar

Pow e r

Selection Guide
RATED OUTPUT POWER GRID-TIE OPERATION PV INPUT (DC) Maximum DC Power Nominal DC Voltage / Maximum DC Voltage Start-up Voltage / Initial Feeding Voltage MPP Voltage Range Number of MPP Trackers / Maximum Input Current GRID OUTPUT (AC) Nominal Output Voltage Output Voltage Range Nominal Output Current Power Factor EFFICIENCY

MODEL

Solarrouter 2KW
2000 W

Solarrouter 4.5KW
3000 W

Solarrouter 4.5KW plus


3000 W

Solarrouter 5KW
5000 W

2250W 300 VDC / 350 VDC 80 VDC / 120 VDC 150 VDC ~ 320 VDC 1 / 1 x 15 A 101/110/120/127 VAC 88 - 127 VAC* 18 A 2000W

3200W

4500W 360 VDC / 500 VDC 116 VDC / 150 VDC 250 VDC ~ 450 VDC 1 / 1 x 18 A 208/220/230/240 VAC 184 - 264.5 VAC* 19.5 A* 4500W > 0.99

7500W

1 / 1 x 13 A

2 / 2 x 15 A

19.5 A* 4500W

21.7 A 5000W

95% 94% OFF-GRID OPERATION AC INPUT AC Start-up Voltage/Auto Restart Voltage Acceptable Input Voltage Range Number of MPP Trackers / Maximum Input Current PV INPUT (DC) Maximum DC Voltage MPP Voltage Range Maximum Input Current BATTERY MODE OUTPUT (AC) Nominal Output Voltage Output Waveform HYBRID OPERATION PV INPUT (DC) Nominal DC Voltage / Maximum DC Voltage Start-up Voltage / Initial Feeding Voltage MPP Voltage Range Maximum Input Current GRID OUTPUT (AC) Nominal Output Voltage Output Voltage Range Nominal Output Current AC INPUT AC Start-up Voltage / Auto Restart Voltage Acceptable Input Voltage Range Maximum AC Input Current BATTERY MODE OUTPUT (AC) Nominal Output Voltage BATTERY & CHARGER Nominal DC Voltage Maximum Charging Current GENERAL PHYSICAL Dimension, D X W X H (mm) Net Weight (kgs) INTERFACE Communication Port Intelligent Slot ENVIRONMENT Humidity Operating Temperature Altitude
*AC voltage range may vary depending on different AC voltage * Power derating 1% every 100 m when altitude is over 1000m.

96% 95%

96% 95%

96% 95%

60 - 70 VAC / 85 VAC 85 - 130 VAC* 30 A 350 VDC 150 VDC ~ 320 VDC 1 / 1 x 15 A 101/110/120/127 VAC 90%

120 - 140 VAC / 180 VAC 170 - 280 VAC 25 A

120 - 140 VAC / 180 VAC 170 - 280 VAC 30 A 500 VDC 250 VDC ~ 450 VDC 1 / 1 x 18 A

120 - 140 VAC / 180 VAC 170 - 280 VAC 40 A

1 / 1 x 13 A

2 / 2 x 15 A

93%

208/220/230/240 VAC Pure Sinewave 93%

91%

300 VDC / 350 VDC 80 VDC / 120 VDC 150 VDC ~ 320 VDC 1 / 1 x 15 A 101/110/120/127 VAC 88-127 VAC 18 A 60 - 70 VAC / 85 VAC 80 - 130 VAC* 30 A 101/110/120/127 VAC 90% 1 / 1 x 13 A

360 VDC / 500 VDC 116 VDC / 150 VDC 250 VDC ~ 450 VDC 1 / 1 x 18 A 208/220/230/240 VAC 184 - 264.5 VAC 19.5 A* 120 - 140 VAC / 180 VAC 170 - 280 VAC 30 A 208/220/230/240 VAC 93% 48 VDC 25A 60A 2 / 2 x 15 A

19.5 A* 120 - 140 VAC / 180 VAC 170 - 280 VAC 25 A

21.7 A* 120 - 140 VAC / 180 VAC 170 - 280 VAC 40 A

93%

91%

170 x 415 x 420 21 RS-232/USB Optional SNMP, Modbus, and AS-400 cards available 0 ~ 90% RH (No condensing) 0 to 40C 0 ~ 1000 m**

135 x 440 x 505 24.5

0 to 40C

-10 to 55C
VDE-AR-N 4105 VDE 0126-1-1

47 www.revosolar.com