Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
U/G System
Number of
Number of
ID
Cable Raceways
Soil
Temperature Limits
RHO
Ambient Temperature
Alarm
Warning
Type
C-cm/Watt
Clay Dry
90.0
35.0
90.0
88.0
Not Considered
Not Considered
100 %
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Fill
cm
cm
cm
cm
Type
C-cm/Watt
Number
of
Conduits
0.00
45.00
76.00
198.00
Heavy Aggregate
85.0
48
Horizontal
RW2-DB-01
Dimension
Vertical
Height
Width
RHO
Number
of
Cables
Average Distance
Center-to-Center
17
17.41
cm
Conduit Data:
Reference Distance
ID
Horizontal
Vertical
cm
cm
Type
Size
Thickness
OD
RHO
Thermal R
Fill
mm
cm
cm
C-cm/Watt
Ohm-m
DB101
8.25
13.25
PVC__40
103
0.602
11.430
600.0
DB113
8.25
29.75
PVC__40
103
0.602
11.430
600.0
0.347
9.97
2.00
DB125
8.25
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
3.00
DB137
8.20
62.70
PVC__40
103
0.602
11.430
600.0
0.347
15.07
4.00
DB102
24.75
13.25
PVC__40
103
0.602
11.430
600.0
5.00
DB103
41.25
13.25
PVC__40
103
0.602
11.430
600.0
6.00
DB104
57.75
13.25
PVC__40
103
0.602
11.430
600.0
7.00
DB105
74.25
13.25
PVC__40
103
0.602
11.430
600.0
8.00
DB106
90.75
13.25
PVC__40
103
0.602
11.430
600.0
9.00
DB107
107.30
13.25
PVC__40
103
0.602
11.430
600.0
10.00
DB108
123.80
13.25
PVC__40
103
0.602
11.430
600.0
11.00
DB109
140.30
13.25
PVC__40
103
0.602
11.430
600.0
12.00
DB110
156.80
13.25
PVC__40
103
0.602
11.430
600.0
13.00
DB111
173.30
13.25
PVC__40
103
0.602
11.430
600.0
14.00
DB112
189.80
13.25
PVC__40
103
0.602
11.430
600.0
DB114
24.75
29.75
PVC__40
103
0.602
11.430
600.0
0.347
20.64
16.00
DB115
41.25
29.75
PVC__40
103
0.602
11.430
600.0
0.347
26.17
17.00
DB116
57.75
29.75
PVC__40
103
0.602
11.430
600.0
18.00
DB117
74.25
29.75
PVC__40
103
0.602
11.430
600.0
19.00
DB118
90.75
29.75
PVC__40
103
0.602
11.430
600.0
DB119
107.30
29.70
PVC__40
103
0.602
11.430
600.0
0.347
30.97
21.00
DB120
123.80
29.75
PVC__40
103
0.602
11.430
600.0
0.347
26.19
22.00
DB121
140.30
29.75
PVC__40
103
0.602
11.430
600.0
23.00
DB122
156.70
29.70
PVC__40
103
0.602
11.430
600.0
24.00
DB123
173.30
29.75
PVC__40
103
0.602
11.430
600.0
25.00
15.00
20.00
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Study Case: CD
Filename:
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Conduit Data:
Reference Distance
Horizontal
Vertical
cm
cm
ID
Size
Thickness
OD
RHO
Thermal R
Fill
Type
mm
cm
cm
C-cm/Watt
Ohm-m
DB124
189.80
29.75
PVC__40
103
0.602
11.430
600.0
DB126
24.75
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
2.00
DB127
41.25
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
3.00
DB128
57.75
46.25
PVC__40
103
0.602
11.430
600.0
DB129
74.25
46.25
PVC__40
103
0.602
11.430
600.0
0.347
28.74
DB130
90.75
46.25
PVC__40
103
0.602
11.430
600.0
DB131
107.30
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
7.00
DB132
123.80
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
8.00
DB133
140.30
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
DB134
156.80
46.25
PVC__40
103
0.602
11.430
600.0
DB135
173.30
46.25
PVC__40
103
0.602
11.430
600.0
11.00
DB136
189.80
46.25
PVC__40
103
0.602
11.430
600.0
12.00
DB138
24.75
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
13.00
DB139
41.25
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
14.00
DB140
57.75
62.75
PVC__40
103
0.602
11.430
600.0
15.00
DB141
74.25
62.75
PVC__40
103
0.602
11.430
600.0
16.00
DB142
90.75
62.75
PVC__40
103
0.602
11.430
600.0
DB143
107.30
62.70
PVC__40
103
0.602
11.430
600.0
0.347
15.07
18.00
DB144
123.80
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
19.00
DB145
140.30
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
20.00
DB146
156.80
62.75
PVC__40
103
0.602
11.430
600.0
21.00
DB147
173.30
62.75
PVC__40
103
0.602
11.430
600.0
22.00
DB148
189.80
62.75
PVC__40
103
0.602
11.430
600.0
23.00
4.00
5.00
6.00
9.00
10.00
17.00
Cable Data:
0.00
Rated
ID
Individual
Growth
Load
Current Factor
Factor
Conductor
Insulation
0.00
Thickness
Thermal R
No.
Type
Per
Phase
47.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
3.0
5.000
662.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
4.8
2.00
0.313 2.00
1.000
78.20
100
100
1/C
CU
ConRnd-NT
RUBBER610
3.7
3.00
0.367 3.00
1.000
108.30
100
100
1/C
CU
ConRnd-NT
RUBBER610
3.7
4.00
0.296 4.00
Size
kV
PC-28-PLLN-SS4-E-04
2/0
1.000
MP-GM-2803
750
MP-GM-2805A
300
MP-GM-2808A
500
Amp
Construction
Type
mm
Ohm-m
0.439
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Study Case: CD
Filename:
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Cable Data:
0.00
Rated
Individual
Growth
Load
Current Factor
Factor
Conductor
Insulation
0.00
No.
Type
34.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.5
1.000
6.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
2.00
1.156 2.00
1.000
12.03
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
3.00
1.156 3.00
1.000
1.50
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
4.00
1.156 4.00
PC-28-AH-EDH-01A
1.000
5.35
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
5.00
1.156 5.00
SSW-GM-2807B
1.000
3.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
6.00
1.156 6.00
MP-GM-2830A
1.000
34.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.5
7.00
0.911 7.00
PC-28-PLCP-SS4-E-01
1.000
13.36
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
8.00
1.156 8.00
ID
Size
kV
MP-GM-2830B
1.000
MP-GM-2843B
PC-28-AH-AC-01A
PC-28-AH-AH-01A
MP-GM-2809A
Amp
Thickness
Thermal R
Per
Phase
Construction
Type
mm
Ohm-m
0.911
1/0
1.000
46.00
100
100
3/C
CU
ConRnd-NT
RUBBER
3.0
9.00
0.881 9.00
PC-28-AH-HCP-01
1.000
5.21
100
100
3/C
CU
ConRnd-NT
RUBBER
2.5
10.00
1.151 10.00
MP-SSW-GM-2808B
1.000
3.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
11.00
1.156 11.00
1.000
3.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
12.00
1.156 12.00
350
5.000
105.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
4.8
13.00
0.430 13.00
MP-SSW-GM-2805B
Cable133
Shielding
ID
PC-28-PLLN-SS4-E-04
MP-GM-2803
Status
Type
None
Yes
End
Connection
Thickness
mm
Open
Copper
Open
0.00
Jacket
0.1
Sheath
Type
Armor
Type
Type
Thickness
Rdc
@ 25C
Outside
Diameter
mm
Ohm/m
cm
NONE
266.02
NONE
47.04
1.86
3.97 2.00
MP-GM-2805A
None
Open
NONE
118.02
2.68 3.00
MP-GM-2808A
None
Open
NONE
70.97
3.02 4.00
MP-GM-2830B
None
Open
NONE
533.69
2.85 5.00
MP-GM-2843B
None
Open
NONE
2140.27
1.80 6.00
PC-28-AH-AC-01A
None
Open
NONE
2140.27
1.80 7.00
PC-28-AH-AH-01A
None
Open
NONE
2140.27
1.80 8.00
PC-28-AH-EDH-01A
None
Open
NONE
2140.27
1.80 9.00
SSW-GM-2807B
None
Open
NONE
2140.27
1.8010.00
MP-GM-2830A
None
Open
NONE
533.69
2.8511.00
PC-28-PLCP-SS4-E-01
None
Open
NONE
2140.27
1.8012.00
MP-GM-2809A
None
Open
NONE
335.62
3.5513.00
PC-28-AH-HCP-01
None
Open
NONE
1350.73
2.2614.00
MP-SSW-GM-2808B
None
Open
NONE
2140.27
1.8015.00
MP-SSW-GM-2805B
None
NONE
2140.27
1.8016.00
NONE
100.96
3.1617.00
Cable133
Yes
Open
Copper
Open
0.1
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
No.
Cable ID
Conduit/Location ID
Conductor
per
Cable
Energized
Conductor
per Cable
Rdc @
Final Temp.
Dielectric
Losses
Ohm/m
Watt/m
0.00
Yc
Ys
Conductor
Losses
Current
Watt/m
Temp.
Amp
Cable133-1A
DB129
110.11
0.078
0.022
0.004
1.241
105.00
48.51
Cable133-1B
DB129
110.11
2.00
0.078
0.022
0.004
1.241
105.00
48.51
Cable133-1C
DB129
110.11
3.00
0.078
0.022
0.004
1.241
105.00
48.51
MP-GM-2803-1A
DB137
50.77
4.00
0.108
0.048
0.001
1.458
165.50
45.58
MP-GM-2803-1B
DB138
50.94
5.00
0.108
0.048
0.001
1.462
165.50
46.49
MP-GM-2803-1C
DB139
51.01
6.00
0.108
0.048
0.001
1.464
165.50
46.91
MP-GM-2803-2A
DB143
51.22
7.00
0.108
0.047
0.001
1.469
165.50
48.04
MP-GM-2803-2B
DB144
51.23
8.00
0.108
0.047
0.001
1.470
165.50
48.11
MP-GM-2803-2C
DB145
51.15
9.00
0.108
0.048
0.001
1.468
165.50
47.69
10
MP-GM-2803-3A
DB125
50.76
10.00
0.108
0.048
0.001
1.457
165.50
45.50
11
MP-GM-2803-3B
DB126
50.94
11.00
0.108
0.048
0.001
1.462
165.50
46.51
12
MP-GM-2803-3C
DB127
51.01
12.00
0.108
0.048
0.001
1.464
165.50
46.91
13
MP-GM-2803-4A
DB131
51.24
13.00
0.108
0.047
0.001
1.470
165.50
48.18
14
MP-GM-2803-4B
DB132
51.24
14.00
0.108
0.047
0.001
1.470
165.50
48.15
15
MP-GM-2803-4C
DB133
51.10
15.00
0.108
0.048
0.001
1.466
165.50
47.41
16
MP-GM-2805A-1A
DB114
127.45
16.00
0.004
0.018
0.000
0.794
78.20
45.73
17
MP-GM-2805A-1B
DB114
127.45
17.00
0.004
0.018
0.000
0.794
78.20
45.73
18
MP-GM-2805A-1C
DB114
127.45
18.00
0.004
0.018
0.000
0.794
78.20
45.73
19
MP-GM-2808A-1A
DB115
76.79
19.00
0.005
0.059
0.000
0.954
108.30
46.27
20
MP-GM-2808A-1B
DB115
76.79
20.00
0.005
0.059
0.000
0.954
108.30
46.27
21
MP-GM-2808A-1C
DB115
76.79
21.00
0.005
0.059
0.000
0.954
108.30
46.27
22
MP-GM-2809A
DB120
365.88
22.00
0.000
0.002
0.000
2.328
46.00
48.40
23
MP-GM-2830A
DB119
582.83
23.00
0.000
0.001
0.000
1.349
34.00
48.89
24
MP-GM-2830B
DB119
582.83
24.00
0.000
0.001
0.000
2.023
34.00
48.89
25
MP-GM-2843B
DB119
2333.06
25.00
0.000
0.000
0.000
0.252
6.00
48.38
26
MP-SSW-GM-2805B
DB120
2327.82
26.00
0.000
0.000
0.000
0.042
3.00
47.74
27
MP-SSW-GM-2808B
DB120
2327.82
27.00
0.000
0.000
0.000
0.042
3.00
47.74
28
PC-28-AH-AC-01A
DB119
2335.48
28.00
0.000
0.000
0.000
1.014
12.03
48.67
29
PC-28-AH-AH-01A
DB119
2332.30
29.00
0.000
0.000
0.000
0.016
1.50
48.28
30
PC-28-AH-EDH-01A
DB119
2332.89
30.00
0.000
0.000
0.000
0.200
5.35
48.36
31
PC-28-AH-HCP-01
DB120
1469.21
31.00
0.000
0.000
0.000
0.080
5.21
47.76
32
PC-28-PLCP-SS4-E-01
DB120
2331.59
32.00
0.000
0.000
0.000
1.249
13.36
48.20
33
PC-28-PLLN-SS4-E-04-1A
DB113
286.35
33.00
0.003
0.004
0.000
0.635
47.00
44.83
34
PC-28-PLLN-SS4-E-04-1B
DB113
286.35
34.00
0.003
0.004
0.000
0.635
47.00
44.83
35
PC-28-PLLN-SS4-E-04-1C
DB113
286.35
35.00
0.003
0.004
0.000
0.635
47.00
44.83
36
SSW-GM-2807B
DB119
2332.45
36.00
0.000
0.000
0.000
0.063
3.00
48.30
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
No.
36
Cable ID
SSW-GM-2807B
Conduit/Location ID
Conductor
per
Cable
Energized
Conductor
per Cable
DB119
Yc = Increment of AC/DC resistance ratio due to AC current skin and proximity effect
Ys = Increment of AC/DC resistance ratio due to losses of circulation and eddy current effect in shield , sheath and armor
Rdc @
Final Temp.
Dielectric
Losses
Ohm/m
Watt/m
2332.45
0.000
0.00
Yc
Ys
0.000
0.000
Conductor
Losses
Current
Watt/m
0.063
Amp
3.00
Temp.
C
48.30
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Summary (RW2-DB-01)
0.00
Current
No.
Cable ID
Conduit/Location ID
Size
Temp.
Amp
Cable133-1A
DB129
350
105.00 F
48.51
Cable133-1B
DB129
350
105.00
48.51
2.00
Cable133-1C
DB129
350
105.00
48.51
3.00
MP-GM-2803-1A
DB137
750
165.50
45.58
4.00
MP-GM-2803-1B
DB138
750
165.50
46.49
5.00
MP-GM-2803-1C
DB139
750
165.50
46.91
6.00
MP-GM-2803-2A
DB143
750
165.50
48.04
7.00
MP-GM-2803-2B
DB144
750
165.50
48.11
8.00
MP-GM-2803-2C
DB145
750
165.50
47.69
9.00
10
MP-GM-2803-3A
DB125
750
165.50
45.50
10.00
11
MP-GM-2803-3B
DB126
750
165.50
46.51
11.00
12
MP-GM-2803-3C
DB127
750
165.50
46.91
12.00
13
MP-GM-2803-4A
DB131
750
165.50
48.18
13.00
14
MP-GM-2803-4B
DB132
750
165.50
48.15
14.00
15
MP-GM-2803-4C
DB133
750
165.50
47.41
15.00
16
MP-GM-2805A-1A
DB114
300
78.20
45.73
16.00
17
MP-GM-2805A-1B
DB114
300
78.20
45.73
17.00
18
MP-GM-2805A-1C
DB114
300
78.20
45.73
18.00
19
MP-GM-2808A-1A
DB115
500
108.30
46.27
19.00
20
MP-GM-2808A-1B
DB115
500
108.30
46.27
20.00
21
MP-GM-2808A-1C
DB115
500
108.30
46.27
21.00
22
MP-GM-2809A
DB120
1/0
46.00
48.40
22.00
23
MP-GM-2830A
DB119
34.00
48.89
23.00
24
MP-GM-2830B
DB119
34.00
48.89
24.00
25
MP-GM-2843B
DB119
6.00
48.38
25.00
26
MP-SSW-GM-2805B
DB120
3.00
47.74
26.00
27
MP-SSW-GM-2808B
DB120
3.00
47.74
27.00
28
PC-28-AH-AC-01A
DB119
12.03
48.67
28.00
29
PC-28-AH-AH-01A
DB119
1.50
48.28
29.00
30
PC-28-AH-EDH-01A
DB119
5.35
48.36
30.00
31
PC-28-AH-HCP-01
DB120
5.21
47.76
31.00
32
PC-28-PLCP-SS4-E-01
DB120
13.36
48.20
32.00
33
PC-28-PLLN-SS4-E-04-1A
DB113
2/0
47.00
44.83
33.00
34
PC-28-PLLN-SS4-E-04-1B
DB113
2/0
47.00
44.83
34.00
35
PC-28-PLLN-SS4-E-04-1C
DB113
2/0
47.00
44.83
35.00
36
SSW-GM-2807B
DB119
3.00
48.30
36.00
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Indicates fixed cable size in cable sizing calculations or fixed cable ampacity in uniform ampacity calculation
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Fill
cm
cm
cm
cm
Type
C-cm/Watt
Number
of
Conduits
396.00
45.00
76.00
198.00
Heavy Aggregate
85.0
48
Horizontal
RW3
Dimension
Vertical
Height
Width
RHO
Number
of
Cables
Average Distance
Center-to-Center
15
16.49
cm
Conduit Data:
Reference Distance
ID
Horizontal
Vertical
cm
cm
Type
Size
Thickness
OD
RHO
Thermal R
Fill
mm
cm
cm
C-cm/Watt
Ohm-m
DB301
8.25
13.25
PVC__40
103
0.602
11.430
600.0
DB302
24.75
13.25
PVC__40
103
0.602
11.430
600.0
2.00
DB303
41.25
13.25
PVC__40
103
0.602
11.430
600.0
3.00
DB304
57.75
13.25
PVC__40
103
0.602
11.430
600.0
4.00
DB305
74.25
13.25
PVC__40
103
0.602
11.430
600.0
5.00
DB306
90.75
13.25
PVC__40
103
0.602
11.430
600.0
6.00
DB307
107.30
13.25
PVC__40
103
0.602
11.430
600.0
7.00
DB308
123.80
13.20
PVC__40
103
0.602
11.430
600.0
8.00
DB309
140.30
13.25
PVC__40
103
0.602
11.430
600.0
9.00
DB310
156.80
13.25
PVC__40
103
0.602
11.430
600.0
10.00
DB311
173.30
13.25
PVC__40
103
0.602
11.430
600.0
11.00
DB312
189.80
13.25
PVC__40
103
0.602
11.430
600.0
12.00
DB313
8.25
29.75
PVC__40
103
0.602
11.430
600.0
13.00
DB314
24.75
29.75
PVC__40
103
0.602
11.430
600.0
14.00
DB315
41.25
29.75
PVC__40
103
0.602
11.430
600.0
15.00
DB316
57.75
29.75
PVC__40
103
0.602
11.430
600.0
16.00
DB317
74.25
29.75
PVC__40
103
0.602
11.430
600.0
17.00
DB318
90.75
29.75
PVC__40
103
0.602
11.430
600.0
18.00
DB319
107.30
29.75
PVC__40
103
0.602
11.430
600.0
19.00
DB320
123.80
29.75
PVC__40
103
0.602
11.430
600.0
20.00
DB321
140.30
29.75
PVC__40
103
0.602
11.430
600.0
21.00
DB322
156.80
29.75
PVC__40
103
0.602
11.430
600.0
DB323
173.30
29.75
PVC__40
103
0.602
11.430
600.0
0.347
30.27
23.00
DB324
189.80
29.75
PVC__40
103
0.602
11.430
600.0
0.347
32.49
24.00
DB325
8.25
46.20
PVC__40
103
0.602
11.430
600.0
22.00
25.00
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Study Case: CD
Filename:
10
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Conduit Data:
Reference Distance
Horizontal
Vertical
cm
cm
Size
Thickness
OD
RHO
Thermal R
Fill
Type
mm
cm
cm
C-cm/Watt
Ohm-m
DB326
24.75
46.25
PVC__40
103
0.602
11.430
600.0
DB327
DB328
41.25
46.25
PVC__40
103
0.602
11.430
600.0
57.75
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
3.00
DB329
74.25
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
4.00
DB330
90.75
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
5.00
DB331
107.30
46.25
PVC__40
103
0.602
11.430
600.0
6.00
DB332
123.80
46.25
PVC__40
103
0.602
11.430
600.0
7.00
DB333
140.30
46.25
PVC__40
103
0.602
11.430
600.0
8.00
DB334
156.80
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
9.00
DB335
173.30
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
10.00
DB336
189.80
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
DB337
8.25
62.75
PVC__40
103
0.602
11.430
600.0
12.00
DB338
24.75
62.75
PVC__40
103
0.602
11.430
600.0
13.00
DB339
41.25
62.75
PVC__40
103
0.602
11.430
600.0
DB340
57.75
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
15.00
DB341
74.25
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
16.00
DB342
90.75
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
17.00
DB343
107.30
62.75
PVC__40
103
0.602
11.430
600.0
18.00
DB344
123.80
62.75
PVC__40
103
0.602
11.430
600.0
19.00
DB345
140.30
62.75
PVC__40
103
0.602
11.430
600.0
20.00
DB346
156.80
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
21.00
DB347
173.30
62.75
PVC__40
103
0.602
11.430
600.0
0.347
15.07
22.00
DB348
189.80
62.70
PVC__40
103
0.602
11.430
600.0
0.347
15.07
23.00
ID
2.00
11.00
14.00
Cable Data:
0.00
Rated
ID
Size
kV
PC-28-PLLN-SS4-E-03
1/0
1.000
PC-28-PLCO-SS4-E-02
Individual
Growth
Load
Current Factor
Factor
Amp
46.78
Conductor
No.
Type
Per
Phase
100
100
3/C
CU
Insulation
0.00
Thickness
Thermal R
mm
Construction
Type
ConRnd-NT
RUBBER
3.0
Ohm-m
0.881
1/0
1.000
40.09
100
100
3/C
CU
ConRnd-NT
RUBBER
3.0
2.00
0.881 2.00
MP-GM-G2834B
1.000
18.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
3.00
1.156 3.00
MP-GM-G2835
1.000
3.80
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
4.00
1.156 4.00
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Study Case: CD
Filename:
11
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Cable Data:
0.00
Rated
Individual
Growth
Load
Current Factor
Factor
Conductor
Insulation
0.00
No.
Type
18.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
1.000
8.90
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
2.00
1.156 2.00
1.000
11.60
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
3.00
1.156 3.00
1.000
3.80
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
4.00
1.156 4.00
MP-GM-G2833
1.000
5.90
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
5.00
1.156 5.00
MP-GM-G2836
1.000
5.90
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
6.00
1.156 6.00
PC-28-BH-2817
1.000
44.10
100
100
3/C
CU
ConRnd-NT
RUBBER
2.5
7.00
0.911 7.00
PC-SSW-GM-2804C
1.000
3.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
8.00
1.156 8.00
ID
Size
kV
MP-GM-G2831B
1.000
MP-GM-G2840A
MP-GM-G2841B
MP-GM-G2832
PC-SSW-GM-2801B
Amp
Thickness
Thermal R
Per
Phase
Construction
Type
mm
Ohm-m
1.156
1.000
3.00
100
100
3/C
CU
ConRnd-NT
RUBBER
2.0
9.00
1.156 9.00
Cable206
750
5.000
166.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
4.8
10.00
0.313 10.00
MP-GM-2801A.
750
5.000
524.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
4.8
11.00
0.313 11.00
Shielding
ID
Status
Type
End
Connection
0.00
Jacket
Thickness
mm
Sheath
Type
Armor
Type
Type
Thickness
Rdc
@ 25C
Outside
Diameter
mm
Ohm/m
cm
PC-28-PLLN-SS4-E-03
None
Open
NONE
335.62
3.55
PC-28-PLCO-SS4-E-02
None
Open
NONE
335.62
3.55 2.00
MP-GM-G2834B
None
Open
NONE
2140.27
1.80 3.00
MP-GM-G2835
None
Open
NONE
2140.27
1.80 4.00
MP-GM-G2831B
None
Open
NONE
2140.27
1.80 5.00
MP-GM-G2840A
None
Open
NONE
2140.27
1.80 6.00
MP-GM-G2841B
None
Open
NONE
2140.27
1.80 7.00
MP-GM-G2832
None
Open
NONE
2140.27
1.80 8.00
MP-GM-G2833
None
Open
NONE
2140.27
1.80 9.00
MP-GM-G2836
None
Open
NONE
2140.27
1.8010.00
PC-28-BH-2817
None
Open
NONE
533.69
2.8511.00
PC-SSW-GM-2804C
None
Open
NONE
2140.27
1.8012.00
PC-SSW-GM-2801B
None
NONE
2140.27
1.8013.00
Cable206
Yes
Copper
Open
Open
0.1
NONE
47.04
3.9714.00
MP-GM-2801A.
Yes
Copper
Open
0.1
NONE
47.04
3.9715.00
ETAP
Project:
Page:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
12
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
No.
Cable ID
Conduit/Location ID
Conductor
per
Cable
Energized
Conductor
per Cable
Rdc @
Final Temp.
Dielectric
Losses
Ohm/m
Watt/m
0.00
Yc
Ys
Conductor
Losses
Current
Watt/m
Temp.
Amp
Cable206-1A
DB328
50.70
0.108
0.048
0.001
1.465
166.00
45.18
Cable206-1B
DB329
50.75
2.00
0.108
0.048
0.001
1.466
166.00
45.44
Cable206-1C
DB330
50.73
3.00
0.108
0.048
0.001
1.465
166.00
45.35
MP-GM-2801A.-1A
DB334
51.01
4.00
0.108
0.048
0.001
1.631
174.67
46.88
MP-GM-2801A.-1B
DB335
51.14
5.00
0.108
0.048
0.001
1.634
174.67
47.63
MP-GM-2801A.-1C
DB336
51.06
6.00
0.108
0.048
0.001
1.632
174.67
47.16
MP-GM-2801A.-2A
DB342
50.87
7.00
0.108
0.048
0.001
1.626
174.67
46.11
MP-GM-2801A.-2B
DB341
50.89
8.00
0.108
0.048
0.001
1.627
174.67
46.24
MP-GM-2801A.-2C
DB340
50.85
9.00
0.108
0.048
0.001
1.626
174.67
46.00
10
MP-GM-2801A.-3A
DB346
50.99
10.00
0.108
0.048
0.001
1.630
174.67
46.81
11
MP-GM-2801A.-3B
DB347
51.04
11.00
0.108
0.048
0.001
1.632
174.67
47.07
12
MP-GM-2801A.-3C
DB348
50.94
12.00
0.108
0.048
0.001
1.629
174.67
46.53
13
MP-GM-G2831B
DB324
2345.61
13.00
0.000
0.000
0.000
2.280
18.00
49.90
14
MP-GM-G2832
DB324
2338.68
14.00
0.000
0.000
0.000
0.101
3.80
49.06
15
MP-GM-G2833
DB324
2339.14
15.00
0.000
0.000
0.000
0.244
5.90
49.11
16
MP-GM-G2834B
DB323
2348.06
16.00
0.000
0.000
0.000
2.282
18.00
50.19
17
MP-GM-G2835
DB323
2341.13
17.00
0.000
0.000
0.000
0.101
3.80
49.35
18
MP-GM-G2836
DB324
2339.14
18.00
0.000
0.000
0.000
0.244
5.90
49.11
19
MP-GM-G2840A
DB324
2340.13
19.00
0.000
0.000
0.000
0.556
8.90
49.23
20
MP-GM-G2841B
DB324
2341.36
20.00
0.000
0.000
0.000
0.945
11.60
49.38
21
PC-28-BH-2817
DB324
585.22
21.00
0.000
0.001
0.000
3.417
44.10
50.06
22
PC-28-PLCO-SS4-E-02
DB323
367.74
22.00
0.000
0.002
0.000
1.777
40.09
49.84
23
PC-28-PLLN-SS4-E-03
DB323
367.99
23.00
0.000
0.002
0.000
2.421
46.78
50.03
24
PC-SSW-GM-2801B
DB324
2338.56
24.00
0.000
0.000
0.000
0.042
3.00
49.04
25
PC-SSW-GM-2804C
DB324
2338.56
25.00
0.000
0.000
0.000
0.042
3.00
49.04
Yc = Increment of AC/DC resistance ratio due to AC current skin and proximity effect
Ys = Increment of AC/DC resistance ratio due to losses of circulation and eddy current effect in shield , sheath and armor
ETAP
Project:
Page:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
13
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Summary (RW3)
0.00
Current
No.
Cable ID
Conduit/Location ID
Size
Temp.
Amp
Cable206-1A
DB328
750
166.00 F
45.18
Cable206-1B
DB329
750
166.00
45.44
2.00
Cable206-1C
DB330
750
166.00
45.35
3.00
MP-GM-2801A.-1A
DB334
750
174.67
46.88
4.00
MP-GM-2801A.-1B
DB335
750
174.67
47.63
5.00
MP-GM-2801A.-1C
DB336
750
174.67
47.16
6.00
MP-GM-2801A.-2A
DB342
750
174.67
46.11
7.00
MP-GM-2801A.-2B
DB341
750
174.67
46.24
8.00
MP-GM-2801A.-2C
DB340
750
174.67
46.00
9.00
10
MP-GM-2801A.-3A
DB346
750
174.67
46.81
10.00
11
MP-GM-2801A.-3B
DB347
750
174.67
47.07
11.00
12
MP-GM-2801A.-3C
DB348
750
174.67
46.53
12.00
13
MP-GM-G2831B
DB324
18.00
49.90
13.00
14
MP-GM-G2832
DB324
3.80
49.06
14.00
15
MP-GM-G2833
DB324
5.90
49.11
15.00
16
MP-GM-G2834B
DB323
18.00
50.19
16.00
17
MP-GM-G2835
DB323
3.80
49.35
17.00
18
MP-GM-G2836
DB324
5.90
49.11
18.00
19
MP-GM-G2840A
DB324
8.90
49.23
19.00
20
MP-GM-G2841B
DB324
11.60
49.38
20.00
21
PC-28-BH-2817
DB324
44.10
50.06
21.00
22
PC-28-PLCO-SS4-E-02
DB323
1/0
40.09
49.84
22.00
23
PC-28-PLLN-SS4-E-03
DB323
1/0
46.78
50.03
23.00
24
PC-SSW-GM-2801B
DB324
3.00
49.04
24.00
25
PC-SSW-GM-2804C
DB324
3.00
49.04
25.00
Indicates fixed cable size in cable sizing calculations or fixed cable ampacity in uniform ampacity calculation
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Filename:
14
Page:
Study Case: CD
5195REPL2 Metric Unit3
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Fill
cm
cm
cm
cm
Type
C-cm/Watt
Number
of
Conduits
198.00
45.00
76.00
198.00
Heavy Aggregate
85.0
48
Horizontal
Section B1
Dimension
Vertical
Height
Width
RHO
Number
of
Cables
Average Distance
Center-to-Center
16.50
cm
Conduit Data:
Reference Distance
ID
Horizontal
Vertical
cm
cm
Type
Size
Thickness
OD
RHO
Thermal R
Fill
mm
cm
cm
C-cm/Watt
Ohm-m
DB201
8.25
13.25
PVC__40
103
0.602
11.430
600.0
DB202
24.75
13.25
PVC__40
103
0.602
11.430
600.0
2.00
DB203
41.25
13.25
PVC__40
103
0.602
11.430
600.0
3.00
DB204
57.75
13.25
PVC__40
103
0.602
11.430
600.0
4.00
DB205
74.25
13.25
PVC__40
103
0.602
11.430
600.0
5.00
DB206
90.75
13.25
PVC__40
103
0.602
11.430
600.0
6.00
DB207
107.30
13.25
PVC__40
103
0.602
11.430
600.0
7.00
DB208
123.80
13.25
PVC__40
103
0.602
11.430
600.0
8.00
DB209
140.30
13.25
PVC__40
103
0.602
11.430
600.0
9.00
DB210
156.80
13.25
PVC__40
103
0.602
11.430
600.0
10.00
DB211
173.30
13.25
PVC__40
103
0.602
11.430
600.0
11.00
DB212
189.80
13.25
PVC__40
103
0.602
11.430
600.0
12.00
DB213
8.25
29.75
PVC__40
103
0.602
11.430
600.0
13.00
DB214
24.75
29.75
PVC__40
103
0.602
11.430
600.0
14.00
DB215
41.25
29.75
PVC__40
103
0.602
11.430
600.0
15.00
DB216
57.75
29.75
PVC__40
103
0.602
11.430
600.0
16.00
DB217
74.25
29.75
PVC__40
103
0.602
11.430
600.0
17.00
DB218
90.75
29.75
PVC__40
103
0.602
11.430
600.0
18.00
DB219
107.30
29.75
PVC__40
103
0.602
11.430
600.0
19.00
DB220
123.80
29.75
PVC__40
103
0.602
11.430
600.0
20.00
DB221
140.30
29.75
PVC__40
103
0.602
11.430
600.0
21.00
DB222
156.80
29.75
PVC__40
103
0.602
11.430
600.0
22.00
DB223
173.30
29.75
PVC__40
103
0.602
11.430
600.0
23.00
DB224
189.80
29.75
PVC__40
103
0.602
11.430
600.0
24.00
DB225
8.25
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
25.00
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Study Case: CD
Filename:
15
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Conduit Data:
Reference Distance
Horizontal
Vertical
cm
cm
Size
Thickness
OD
RHO
Thermal R
Fill
Type
mm
cm
cm
C-cm/Watt
Ohm-m
DB226
24.75
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
DB227
DB228
41.25
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
57.75
46.25
PVC__40
103
0.602
11.430
600.0
3.00
DB229
74.25
46.25
PVC__40
103
0.602
11.430
600.0
4.00
DB230
90.75
46.25
PVC__40
103
0.602
11.430
600.0
5.00
DB231
107.30
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
6.00
DB232
123.80
46.25
PVC__40
103
0.602
11.430
600.0
0.347
15.07
7.00
DB233
140.30
46.20
PVC__40
103
0.602
11.430
600.0
0.347
15.07
8.00
DB234
156.80
46.25
PVC__40
103
0.602
11.430
600.0
9.00
DB235
173.30
46.25
PVC__40
103
0.602
11.430
600.0
10.00
DB236
189.80
46.25
PVC__40
103
0.602
11.430
600.0
DB237
8.25
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
12.00
DB238
24.75
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
13.00
DB239
41.25
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
14.00
DB240
57.75
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
15.00
DB241
74.25
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
16.00
DB242
90.75
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
17.00
DB243
107.30
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
18.00
DB244
123.80
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
19.00
DB245
140.30
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
20.00
DB246
156.80
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
21.00
DB247
173.30
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
22.00
DB248
189.80
62.75
PVC__40
103
0.602
11.430
600.0
0.347
20.23
23.00
ID
2.00
11.00
Cable Data:
0.00
Rated
Individual
Growth
Load
Current Factor
Factor
Conductor
Insulation
0.00
Thickness
Thermal R
Size
kV
Amp
No.
Type
Per
Phase
MP-GM-2803-LOT02
750
5.000
331.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
4.8
MP-2804B
750
15.000
287.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
7.5
2.00
0.450 2.00
MP-2804A
750
15.000
287.00
100
100
1/C
CU
ConRnd-NT
RUBBER610
7.5
3.00
0.450 3.00
ID
Construction
Type
mm
Ohm-m
0.313
ETAP
Project:
12.5.0C
Location:
Contract:
Engineer:
Study Case: CD
Filename:
16
Page:
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Shielding
0.00
Jacket
Armor
Type
Thickness
mm
Ohm/m
cm
Type
End
Connection
MP-GM-2803-LOT02
Yes
Copper
Open
0.1
NONE
47.04
3.97
MP-2804B
Yes
Copper
Open
0.1
NONE
47.04
4.60 2.00
MP-2804A
Yes
Copper
Open
0.1
NONE
47.04
4.60 3.00
mm
Sheath
Type
Outside
Diameter
Status
ID
Thickness
Rdc
@ 25C
Type
ETAP
Project:
Page:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
17
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
No.
Cable ID
Conduit/Location ID
Conductor
per
Cable
Energized
Conductor
per Cable
MP-2804A-1A
DB243
MP-2804A-1B
DB244
MP-2804A-1C
DB245
MP-2804A-2A
DB246
MP-2804A-2B
MP-2804A-2C
7
8
Rdc @
Final Temp.
Dielectric
Losses
Ohm/m
Watt/m
0.00
Yc
Ys
Conductor
Losses
Current
Watt/m
Temp.
Amp
51.12
0.673
0.048
0.001
1.103
143.50
47.48
51.11
2.00
0.673
0.048
0.001
1.102
143.50
47.42
51.06
3.00
0.673
0.048
0.001
1.102
143.50
47.17
50.99
4.00
0.673
0.048
0.001
1.100
143.50
46.76
DB247
50.91
5.00
0.673
0.048
0.001
1.099
143.50
46.34
DB248
50.83
6.00
0.673
0.048
0.001
1.097
143.50
45.90
MP-2804B-1A
DB237
51.10
7.00
0.673
0.048
0.001
1.102
143.50
47.36
MP-2804B-1B
DB238
51.14
8.00
0.673
0.048
0.001
1.103
143.50
47.62
MP-2804B-1C
DB239
51.14
9.00
0.673
0.048
0.001
1.103
143.50
47.62
10
MP-2804B-2A
DB240
51.12
10.00
0.673
0.048
0.001
1.103
143.50
47.49
11
MP-2804B-2B
DB241
51.10
11.00
0.673
0.048
0.001
1.102
143.50
47.40
12
MP-2804B-2C
DB242
51.10
12.00
0.673
0.048
0.001
1.102
143.50
47.41
13
MP-GM-2803-LOT02-1A
DB225
50.93
13.00
0.108
0.048
0.001
1.462
165.50
46.48
14
MP-GM-2803-LOT02-1B
DB226
50.97
14.00
0.108
0.048
0.001
1.463
165.50
46.69
15
MP-GM-2803-LOT02-1C
DB227
50.96
15.00
0.108
0.048
0.001
1.463
165.50
46.63
16
MP-GM-2803-LOT02-2A
DB231
50.93
16.00
0.108
0.048
0.001
1.462
165.50
46.47
17
MP-GM-2803-LOT02-2B
DB232
50.93
17.00
0.108
0.048
0.001
1.462
165.50
46.46
18
MP-GM-2803-LOT02-2C
DB233
50.88
18.00
0.108
0.048
0.001
1.460
165.50
46.16
Yc = Increment of AC/DC resistance ratio due to AC current skin and proximity effect
Ys = Increment of AC/DC resistance ratio due to losses of circulation and eddy current effect in shield , sheath and armor
ETAP
Project:
Page:
12.5.0C
Location:
Contract:
Engineer:
Filename:
Study Case: CD
5195REPL2 Metric Unit3
18
Date:
03-12-2013
SN:
TOYOINDIA
Revision:
Base
Study:
Steady-State Temperature
Current
No.
Cable ID
Conduit/Location ID
Size
Temp.
Amp
MP-2804A-1A
DB243
750
143.50 F
47.48
MP-2804A-1B
DB244
750
143.50
47.42
2.00
MP-2804A-1C
DB245
750
143.50
47.17
3.00
MP-2804A-2A
DB246
750
143.50
46.76
4.00
MP-2804A-2B
DB247
750
143.50
46.34
5.00
MP-2804A-2C
DB248
750
143.50
45.90
6.00
MP-2804B-1A
DB237
750
143.50
47.36
7.00
MP-2804B-1B
DB238
750
143.50
47.62
8.00
MP-2804B-1C
DB239
750
143.50
47.62
9.00
10
MP-2804B-2A
DB240
750
143.50
47.49
10.00
11
MP-2804B-2B
DB241
750
143.50
47.40
11.00
12
MP-2804B-2C
DB242
750
143.50
47.41
12.00
13
MP-GM-2803-LOT02-1A
DB225
750
165.50
46.48
13.00
14
MP-GM-2803-LOT02-1B
DB226
750
165.50
46.69
14.00
15
MP-GM-2803-LOT02-1C
DB227
750
165.50
46.63
15.00
16
MP-GM-2803-LOT02-2A
DB231
750
165.50
46.47
16.00
17
MP-GM-2803-LOT02-2B
DB232
750
165.50
46.46
17.00
18
MP-GM-2803-LOT02-2C
DB233
750
165.50
46.16
18.00
Indicates fixed cable size in cable sizing calculations or fixed cable ampacity in uniform ampacity calculation