: UNIT :
03-May-13 S.Rahimi 0
Input Data Emergency Case Required Relieving Rate Gas Specific Heat Ratio Gas MW Gas Compressibility Factor Relieving Temperature --Nm3/hr ---------C PV-27008B Fully Close 100.2 1.4 28 1 50 PV-27008A Fully Open 760.0 1.4 28 1 50 Gas Blowby (LV-27005 FO) 1568.0 1.4 20 1 65 Fire 7250.0 1.4 18 1 100
Relief Valve Inputs Set Pressure Overpressure Backpressure Atmospheric Pressure Effective Discharge Coeff (Kd) Calculation Results Required Relieving Rate Relieving Pressure Relieving Temperature Backpressure F Coefficient Calculated Area Relief Valve Calculated ID
40 10 0 1.01 0.65
40 10 0 1.01 0.65
40 10 0 1.01 0.65
40 10 0 1.01 0.65
Valve Specification Relief Valve Selected ID Selected Area Actual Relieving Rate Actual Relieving Rate Note
www.chemwork.org
03-May-13 S.Rahimi 0
Input Data Relieving Rate (Inbreathing) Air Specific Heat Ratio Air MW Air Compressibility Factor
Nm3/hr ----------
137.1 1.4 29 1
Relief Valve Inputs Set Pressure Overpressure Ambient Temperature Atmospheric Pressure Effective Discharge Coeff (Kd)
Calculation Results Required Relieving Rate Relieving Pressure Relieving Temperature Backpressure (tank) F coefficient Calculated Area Relief Valve Calculated ID
Valve Specification Relief Valve Selected ID Selected Area Actual Relieving Rate Actual Relieving Rate
Note