Product Overview The NetEngine40E series universal service router (NE40E) is a family of high-end network products that are usually deployed at the edges of Internet Protocol (IP) backbone networks, IP Metropolitan Area Networks (MANs), and other large-scale IP networks. The NE40E, ME60, NE20E-S and NE5000E together provide a complete, layered IP network solution. The NE40E can be flexibly deployed at the edge or core of IP or MPLS networks, simplifying the network structure. With its ability to provide an extensive range of services with reliable service quality, the NE40E is enabling IP and MPLS bearer networks to develop greater broadband capacity and to become more secure, intelligent, and service-oriented. Based on distributed hardware forwarding and non-blocking switching technologies, the NE40E features line-rate forwarding capability, a well designed Quality of Service (QoS) mechanism, strong service processing capability, and excellent expansibility. The NE40E is based on a 400G platform and provides 100G line cards to satisfy increased demand for bandwidth. Compatible with all line cards currently in use, the NE40E minimizes the need for additional investments. Ordering NE40E Router Configuration Flow: Basic Configuration - Services Boards Special Service BoardsSoftware, LicenseElectrical or Optical Modules Cabinet Cables Accessories

1 Basic Configuration
1Chassiswith power Select a chassis based on the number of service boards required.
BOM Number SBOM Type Description Main Control Switc hing Servic e Slots 02351596 CR52-BKPE-4 U-DC NetEngine40E-X3,C R5Z1BKPE,Integrate d DC Chassis In the chass 1+1 Backup is, no need to config ure 3 2 <=1100W <=1100W Power Slots Maximum Power Consumption

Components(NE40E -X3)-4U

02351597 CR52-BKPE-5 U-AC

NetEngine40E-X3,C R5Z2BKPE,Integrate d AC Chassis

Components(NE40E -X3)-5U

02351930 CR5B0BKP08 70

NetEngine40E,CR5Z 1BKP08A,NE40E-X8 Integrated Chassis 1+1 Backup

<=3300W

Components(Includi ng 4 DC Power)

02351931 CR5B0BKP16 70

NetEngine40E,CR5Z 1BKP16A,NE40E-X1 6 Integrated Chassis Components(Includi ng 8 DC Power)-32U 1+1 Backup

<=6500W

16

02400376

CR5B0PWRB X60

Power Distribution Cabinet,220V,50/60 HZ,72000mA,None, EPS200-4850A Power module--33degC-65 degC-90VAC-290VA C-(-53.5)VDC/54.2AAC/DC rectifier Monitor and Alarm Cable,3m,D9M,CC4 P0.48B(S),D9M

NE40E-X8/X16 AC must configure1 for X82 for X16 NE40E-X8/X16 AC must configure4 for X88 for X16

02130872

WPSU50A00

04080076

None

NE40E-X8/X16 AC must configure1 for X82 for X16

2Main control and SFUSelect a main control board according to the chassis, bandwidth and backup requirements.
BOM Number 03030KKR SBOM Type Description Applicable Chassis 1:1 Backup Remarks

CR52-MPUD

NetEngine40E,CR5 2MPUD0,Main Processing Unit D(Including 1*2G Memory and 1*1G CF Card)

NE40E-X3

Mandatory and not preferred. Each device is configured with one MPUD or two MPUDs. Memory cards and CF cards need to be prepared additionally. Each MPUD can be configured with two CF cards and one DDR2 memory card. Mandatory and preferred. Each device is configured with 1 or 2 pcs. It contains a 2 G DDR3 memory card and a 2 G EUSB, which are not quoted independently. It is supported only in V6R5C00 and later versions. Not preferred. It supports only 40 G LPUs. Each device is configured with one or two pcs. It can be configured with two CF

03054206

CR5D0MPUD 170

NetEngine40E,CR5 2MPUD2,Main Processing Unit D2(Including 2G Memory and 2G USB) NetEngine40E,CR5 7SRU40A4,Switch and Route Processing Unit

1:1

NE40E-X3

03030KSR CR5D0SRUA4 70

1:1 NE40E-X8

A4(Including 1*2G Memory and 1*1G CF Card)

cards, two DDR2 memory cards, and two USB disks. By default, it contains one 1 GB CF card and one 2 GB memory card. The other CF card, memory card, and USB disks need to be prepared and quoted additionally.
1:1

03053549

CR5D0SRUA5 70

NetEngine40E,CR5 7SRU200A5,Switch and Route Processing Unit A5(Including One 2G Memory and One 1G CF Card)

NE40E-X8

Preferred. It is optional for supporting 100 Gbit/s LPUs and supported in V600R003 or later versions. Each device is equipped with one or two pcs. It can be configured with two CF cards, two DDR2 memory cards, and two USB disks. By default, it contains one 1 GB CF card and one 2 GB memory card. The other CF cards, memory card, and USB disks need to be prepared and quoted additionally.
Not preferred

03030KSY

CR5DSFUI407 C

NetEngine40E-CR5 7SFU40C0-40Gbps Switch Fabric Unit C NetEngine40E-CR5 7SFU200C0-200Gb ps Switch Fabric Unit C

2+1 NE40E-X8

03053548 CR5DSFUIE0 7C

2+1 NE40E-X8

Preferred. It is used to replace the SFU with the BOM number as 03030KSY. Mandatory and preferred. Each device is configured with one MPUD or two MPUB4s. Each MPUB4 can be configured with two CF cards, two DDR2 memory cards, and two USB disks. By default, each MPUB4 is attached with one 1 GB CF card and one 2 GB memory card. The other CF card, memory card, and USB disks need to be prepared and quoted additionally. Not preferred

03030JTW

1:1

CR5D0MPUB 460

NetEngine40E,CR5 6MPUB4,Main Processing Unit B4(Including 1*2G Memory and 1*1G CF Card)

NE40E-X1 6

03030KSX

CR5DSFUI407 B

NetEngine40E-CR5 7SFU40C0-40Gbps Switch Fabric Unit B NetEngine40E-CR5 7SFU200B0-200Gb

NE40E-X1 6 NE40E-X1 6

3+1

03053547

CR5DSFUIE0 7B

3+1

Preferred. It is used to replace the 03030KSX. It is optional for

ps Switch Unit B

Fabric

supporting 100 Gbit/s LPUs and mandatory for supporting 200 Gbit/s LPUs. It is used together with the SRU200A5 and supported in V600R003C00 or a later version.

3CF Card, Memory card and USB Disks Configuration notes of the CF card, memory card and USB disks
BOM Number SBOM Type CF-512M CF-1G MEM-1G-184pin Model CF Card CF Card Memory Card SDRAM type. This type of memory cards is applied to the MPUs on the NE40E-X3 and NE40E-X16 and SRU on the NE40E-X8. 02316431 MEM-2G-240pin Memory Card 2GB 240pin memory module It is mandatory and of DDR2 SDRAM type. This type of memory cards is applied to the MPUs on the NE40E-X3 and NE40E-X16 and SRU on the NE40E-X8. Description Remarks

02315064 02316042
02315063

512 MB CF card 1 GB CF card


MEM-1G-184pin

Mandatory. Mandatory.
It is mandatory and of DDR

06010171

NUSBDSK01

USB Disk

Storage,

USB

Optional. It is applied to the SRU40A4 on the NE40E-X8 and the MPUB4 of the

disk,4GB/USB2.0

NE40E-X16.

NE40E-X3 The CR52MPUD (03030KKR) of the NE40E-X3 can be configured with two CF cards and the maximum capacity of a single CF card can be 1 GB. By default, the CR52MPUD is already attached with one 1 GB CF card. During

configuration, you must configure another CF card. The CF card with the BOM number being 02316042 is recommended. The CR52MPUD2 contains CF cards. Customers do not need to purchase additionally. The CR52MPUD (03030KKR) of the NE40E-X3 has one memory slot and supports single DDR2 memory cards of a maximum of 2 GB. By default, the CR52MPUD is already attached with a 2 GB memory card. You do not need to purchase the memory card independently during the contract configuration. The CR52MPUD2 contains 2 GB DDR3 memory cards. Customers do not need to purchase additionally. CR52-MPUD does not support USB disks. CR5D0MPUD170 supports 2G USB and it is contained and need not to be configured. NE40E-X8 The CR57SRU40A4 (03030KSR) of the NE40E-X8 can be configured with two CF cards and the maximum capacity of a single CF card can be 1 GB. By default, the CR57SRU40A4 is already attached with one 1 GB CF card. During configuration, you must configure another CF card. The CF card with the BOM number being 02316042 is recommended. he CR57SRU40A4 (03030KSR) of the NE40E-X8 supports 2 GB DDR2 SDRAM memory cards and can be configured with a maximum of two such memory cards. The CR57SRU40A4 is already attached with one 2 GB memory card. It is recommended that the CR57SRU40A4 be configured with another memory card of the BOM number 02316431 during the contract configuration. The CR57SRU40A4 (03030KSR) of the NE40E-X8 supports two USB2.0 interfaces. Each SRU40A4 supports a maximum of two USB disks, and each NE40E-X8 supports a maximum of four USB disks. By default, no USB disk is configured. How many USB disks (06010161 or 06010171) needs to be configured depend on customers' requirements. The USB disk is used to upgrade the system software package. It is recommended that each device be configured with one USB disk. After the upgrade, you need to copy the system software package to the CF card.

NE40E-X16 The CR56MPUB4 (03030JTW) of the NE40E-X16 can be configured with two CF cards and the maximum capacity of a single CF card can be 1 GB. By default, the CR56MPUB4 is already attached with one l GB CF card. During configuration, you must configure another CF card. The CF card with the BOM number as 02316042 is recommended. The CR56MPUB4 (03030JTW) of the NE40E-X16 supports 2 GB DDR2 SDRAM memory cards and can be configured with a maximum of two such memory cards. The CR56MPUB4 is already attached with one 2 GB memory card. It is recommended that the CR56MPUB4 be configured with another memory card of the BOM number 02316431 during the contract configuration. In 1:1 mode of MPUs or SRUs, the capacity of the memory cards of the MPUs or SRUs must be the same. The memory cards configured for one board must share the same BOM number, and it is better to have them supplied by the same manufacturer. The CR56MPUB4 (03030JTW) of the NE40E-X16 supports two USB2.0 interfaces. Each MPUB4 supports a maximum of two USB disks, and each NE40E-X16 supports a maximum of four USB disks. By default, no USB disk is configured. You can determine the number of USB disks with the BOM number being 06010161 or 06010171 according to customers' requirements. The USB disk is used to upgrade the system software package. It is recommended that each device be configured with one USB disk. After the upgrade, you need to copy the system software package to the CF card.

2 Service Slots
1 Configuration Notes of the LPUF-10: The LPUF-10 (03038461) is a 10 Gbit/s platform for flexible cards. It provides four slots for flexible cards of the same type or different types, and supports hot swap of flexible cards. The LPUF-10 supports a maximum of 10-Gbit/s bandwidth. When the total bandwidth of ports in the four slots exceeds 10 Gbit/s, the line-rate forwarding performance is not ensured.
BOM Number 03038461 SBOM Type CR53-LPUF-10 Description Flexible Card Line Processing Unit(LPUF-10,four slots) Remarks The LPUF-10 (03038461) is a 10 Gbit/s platform for flexible cards. It provides four slots for flexible cards of the same type or

different types, and supports hot swap of flexible cards. 03030FSL CR53-P10-1xPOS /STM64-XFP 1-Port OC-192c/STM-64c POS-XFP Flexible Card(Occupy two slots) Each flexible card occupies two subcard slots on the LPUF-10. It is strongly recommended that only P1XX be configured for each LPUF-10. The XFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of one XFP optical module. Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules. All interfaces support the sending of Ethernet synchronous clock signals and meanwhile only the interface 0/1 supports the receiving of Ethernet synchronous clock signals. SFP optical modules with electrical interfaces can be inserted into the interfaces of each flexible card. 03030GBV CR53-P10-1xPOS /STM16-SFP 1-Port OC-48c/STM-16c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of one SFP optical module. 03030GUG CR53-P10-2xATM /STM4-SFP 2-Port OC-12c/STM-4c ATM-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of two SFP optical modules. 03030GBR CR53-P10-4xATM /STM1-SFP 4-Port OC-3c/STM-1c ATM-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four SFP optical modules. 03030HNJ CR53-P10-2xPOS /STM16-SFP 2-port OC-48c/STM-16c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of two SFP optical modules. Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four SFP optical modules. 03030JCY CR53-P10-4xPOS /STM4-SFP 4-port OC-12c/STM-4c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four

03030EYA

CR53-P10-8x100/ 1000Base-X-SFP

8-Port 100/1000Base-X-SFP Flexible Card

03030JCX

CR53-P10-4xPOS /STM16-SFP

4-port OC-48c/STM-16c POS-SFP Flexible Card

SFP optical modules. 03030JTY CR53-P10-4xPOS /STM1-SFP 4-port OC-3c/STM-1c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of four SFP optical modules. 03030JUB CR53-P10-8xPOS /STM4-SFP 8-port OC-12c/STM-4c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules. 03030JUA CR53-P10-8xPOS /STM1-SFP 8-port OC-3c/STM-1c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules. 03030KBB CR53-P10-2xcPO S/STM1-SFP 2-Port Channelized OC-3c/STM-1c POS-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of two SFP optical modules. Each flexible card occupies one subcard slot on the LPUF-10. Coaxial cables are used as user cables. Each flexible card occupies one subcard slot on the LPUF-10 and needs to be connected to a conversion box through the cable (04070064). If the cable is a coaxial cable with SMB connectors, the conversion box (02351608) is used. If the cable is a twisted-pair cable with RJ48 connectors, the conversion box (02351606 or 02351607) is used. Each flexible card occupies one subcard slot on the LPUF-10. The SFP optical module needs to be prepared additionally and each LPUF-10 can be configured with a maximum of eight SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. In addition to IEEE 1588v2, all interfaces support the sending and receiving of Ethernet synchronous clock signals. 02351606 02351607 02351608 DB100-24xRJ48E1/T1-Box DB100-48xRJ48E1/T1-Box DB100-24xSMB-E 24*E1/T1 DB100 to RJ48 Port Conversion Box 48*E1/T1 DB100 to RJ48 Port Conversion Box 24*E1 DB100 to SMB Port Each flexible card (03030KHP) is configured with one conversion box. Every two flexible cards (03030KHP) are configured with one conversion box. Each flexible card (03030KHP) is

03030HNE

CR53-P10-4xE3/c T3-SMB

4-Port Clear Channel E3/Channelized T3-SMB Flexible Card 24-Port Channelized E1/T1-DB100 Flexible Card (Supporting 1588v2)

03030KHP

CR53-P10-24xcE 1/cT1-DB100

03030KNE

CR5M0E8GFA30

8-Port 100/1000Base-X-SFP Flexible Card A(P10-A,Supporting 1588v2)

1-Box 04070064 DB100-DB100-Ca ble-4m

Conversion Box Signal cable ,24E1 Transit Cable,4m,D100M-I,3*CC16P0. 4P430U(S)-I,D100M-I

configured with one conversion box. Each flexible card (03030KHP) is configured with one cable.

2 Configuration Notes of the LPUF-21: The LPUF-20 and LPUF-21 are newly increased in NE80E/40E V300R003. Adopting the SD588 processors, the LPUF-20 and LPUF-21 are 20 Gbit/s platforms for flexible cards and support a maximum bandwidth of 20 Gbit/s. When the total bandwidth of the interfaces on the LPUF-20 and LPUF-21 in two slots exceeds 20 Gbit/s, the line-rate forwarding performance is not ensured on all interfaces. The LPUF-20/21 provides two slots for flexible cards of the same type or different types. According to the support for hot swap of the flexible card, the LPUF-20 can be classified into the LPUF-20 supporting hot swap (03030HVN and 02316416) and the LPUF-20 that does not support hot swap (02315504 and 02315756). The LPUF-21 supports hot swap of the flexible card. In the case of the LPUF-20 that does not support hot swap of the flexible card, before installing the LPUF-20, you need to first insert flexible cards into the LPUF-20, and before removing flexible cards, you need to first remove the LPUF-20. In the case of the LPUF-20 that supports hot swap of the flexible card and the LPUF-21, you can install the LPUF-20/21 and insert or remove the flexible cards in any order. The LPUF-20/-21-A supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number 03030KJY SBOM Type CR52-LPUF-21-A Description Flexible Card Line Processing Unit(LPUF-21,2 sub-slots) A (L3VPN,MVPN,IPV6 Enhanced) Remarks Supports hot swap of the flexible card and is preferred. Supports services such as L3VPN, MVPN, and enhanced IPV6. Supports full-width and half-width flexible cards. Supports hot swap of subcards. Supports services such as L3VPN, MVPN, and IPV6 enhanced. Supports both half-width subcards and full-width subcards. Supports the traffic management function. Supports PPPoE users access. The board is supported since V600R005C00. 03030GSG CR52-P20-12x10/100/ 1000Base-TX-RJ45 CR52-P20-1x10GBas e WAN/LAN-XFP 12-Port 10/100/1000Base-RJ45 Flexible Card 1-Port 10GBase WAN/LAN-XFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-20/21. Each flexible card occupies one subcard slot on the LPUF-20/21. The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of one XFP optical module. It supports the sending and receiving of

03053989

CR5DLPUF202E

Flexible Card Line Processing Unit(LPUF-21,2 sub-slots) E

03030GSK

Ethernet synchronous clock signals. 03030GSH CR52-P20-12x100/10 00Base-X-SFP 12-Port 100/1000Base-SFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-20/21. The SFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 12 optical modules. All interfaces support the sending of Ethernet synchronous clock signals and meanwhile only the interface 0/1 supports the receiving of Ethernet synchronous clock signals. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. 03030HND CR52-P20-1xPOS/ST M64-XFP 1-Port OC-192c/STM-64c POS-XFP Flexible Card Each flexible card occupies one subcard slot on the LPUF-20/21. The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of one XFP optical module. 03030JUJ CR52-P21-40x10/100/ 1000Base-TX-RJ45 40-Port 10/100/1000Base-RJ45 Flexible Card(Occupy two sub-slots) 40-Port 100/1000Base-SFP Flexible Card(Occupy two sub-slots) It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21. It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21. The SFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 40 SFP optical modules. All interfaces of the flexible card support the sending of Ethernet synchronous clock signals but each time only one interface supports the receiving of Ethernet synchronous clock signals. The interface supporting the receiving of Ethernet synchronous clock signals is selected through software among the 40 interfaces on the flexible card. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. 03030JUK CR52-P21-4x10GBas e WAN/LAN-XFP 4-port 10GBase WAN/LAN-XFP Flexible Card(Occupy two sub-slots) It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21. The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of four XFP optical modules. All interfaces of the flexible card support the sending of Ethernet synchronous clock signals but each time only one interface supports the receiving of Ethernet synchronous clock signals. The interface supporting the receiving of Ethernet synchronous clock signals is selected

03030JUL

CR52-P21-40x100/10 00Base-X-SFP

through software among the four interfaces on the flexible card. 03030FDY CR52-P20-48x10/100 Base-TX-RJ45 2-Port 10GBase LAN/WAN-XFP+20-Port 100/1000Base-X-SFP Flexible Card(P20,Occupy two sub-slots) It can be inserted into only the LPUF-21 and each flexible card occupies two subcard slots on the LPUF-21. The XFP and SFP optical modules need to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 2 XFP optical modules and 20 SFP optical modules. All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. 03030KKP CR52-P20-12x100/10 00Base-X-SFP-A 1-Port 10GBase WAN/LAN-XFP Flexible Card A(Supporting 1588v2) Each flexible card occupies one subcard slot on the LPUF-20/21. Interfaces on the flexible card support the sending and receiving of Ethernet synchronous clocks and IEEE 1588v2. The XFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of one XFP optical module. Each flexible card occupies one subcard slot on the LPUF-20/21. The SFP optical module needs to be prepared additionally and each LPUF-20/21 can be configured with a maximum of 12 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software. All interfaces support IEEE 1588v2. 12-Port 100/1000Base-X-SFP Flexible Card B(P20-B) 03030HVJ CR5M0EBGFB20 Each flexible card occupies one subcard slot on the LPUF-21 and supports PPPoE and IPoE. The SFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of 12 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. Each flexible card occupies one subcard slot on the LPUF-21 and supports PPPoE and IPoE. The XFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of one XFP optical module.

03030KKQ

CR5ML2XEEG20

12-Port 100/1000Base-SFP Flexible Card A(Supporting 1588v2)

03030HVH

CR5M0L1XXB20

1-Port 10GBase LAN/WAN-XFP Flexible Card B(P20-B)

03030LVG

CR5M0L1XXE20

1-Port 10GBase LAN/WAN-XFP Flexible Card E(P20-E)

Each flexible card occupies one subcard slot on the LPUF-21 and supports downstream TM. The XFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of one XFP optical module. Each flexible card occupies one subcard slot on the LPUF-21 and supports downstream TM. The XFP optical module needs to be prepared additionally and each LPUF-21 can be configured with a maximum of 10 XFP optical modules. XFP optical modules with 1000M electrical interfaces can be inserted into the interfaces of each flexible card.

10-Port 1000Base-X-SFP Flexible Card E(P20-E)

03030LVF

CR5M0EAGFE20

3Configuration Notes of the LPUF-40: The LPUF-40 is a 40 Gbit/s platform for flexible cards and supports a maximum bandwidth of 40 Gbit/s. The LPUF-40 provides two slots for flexible cards of the same type or different types, and supports hot swap of the flexible card. The LPUF-40-A supports services such as L3VPN, MVPN, and enhanced IPV6.
BOM Number 03030KWD CR5MLPUF402A SBOM Type Description Flexible Card Line Processing Unit(LPUF-40,2 sub-slots) A (L3VPN,MVPN,IPv6 Enhanced) Flexible Card Line Processing Unit(LPUF-40,2 sub-slots) E CR5DLPUF402E Remarks Supports hot swap of the flexible card and is preferred. Supports services such as L3VPN, MVPN, and enhanced IPV6. Supports hot swap of subcards. Supports services such as L3VPN, MVPN, and IPV6 enhanced. Supports the traffic management function. Supports PPPoE users access. The board is supported since V600R005C00. 03036967 CR5M00EEGF20 20-Port 100/1000Base-X-SFP Flexible Card(P40) Each flexible card occupies one subcard slot on the LPUF-40. All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software. The SFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of 20 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. The 100M SFP optical module is supported and a maximum of 20 100M SFP optical modules can be inserted into

03053990

each flexible card. 03037070 CR5M0EEGFA20 20-Port 100/1000Base-X-SFP Flexible Card A(P40-A,Supporting 1588v2) Each flexible card occupies one subcard slot on the LPUF-40. All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software. The SFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of 20 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. All interfaces on the flexible card support IEEE 1588v2. The 100M SFP optical module is supported and a maximum of 20 100M SFP optical modules can be inserted into each flexible card. 03036752 CR5M00L2XX20 2-Port 10GBase LAN/WAN-XFP Flexible Card(P40) Each flexible card occupies one subcard slot on the LPUF-40. All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software. The XFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of two XFP optical modules. 03038466 CR5M0L2XXA20 2-Port 10GBase LAN/WAN-XFP Flexible Card A(P40-A,Supporting 1588v2) Each flexible card occupies one subcard slot on the LPUF-40. All interfaces support the sending of Ethernet synchronous clocks and meanwhile only one interface supports the receiving of Ethernet synchronous clocks through software. The XFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of two XFP optical modules. All interfaces on the flexible card support IEEE 1588v2. 03030MDK CR5M0L2XXB20 2-Port 10GBase LAN/WAN-XFP Flexible Card B(P40-B,Supporting PPPoE and IPoE) Each flexible card occupies one subcard slot on the LPUF-40 and supports PPPoE and IPoE. The XFP optical module needs to be prepared additionally and each LPUF-40 can be configured with a maximum of two XFP optical modules. The flexible card is supported in V600R002C02 and later versions. 03030MDS CR5M0EEGFB20 20-Port 100/1000Base-X-SFP Flexible Card B(P40-B,Supporting PPPoE Each flexible card occupies one subcard slot on the LPUF-40 and supports PPPoE and IPoE. The SFP optical module needs to be

and IPoE)

prepared additionally and each LPUF-40 can be configured with a maximum of 20 SFP optical modules. SFP optical modules with 10M/100M/1000M electrical interfaces can be inserted into the interfaces of each flexible card. The 100M SFP optical module is supported and a maximum of 20 100M SFP optical modules can be inserted into each flexible card. The flexible card is supported in V600R002C02 and later versions.

03030MLA CR5D00EEGE70

20-Port 10/100/1000Base-RJ45 Flexible Card(P40)

Each subcard requires an LPUF-40 subcard slot. The board is supported by NE40E since V600R005C00. Each subcard requires an LPUF-40 subcard slot. At most four XFP optical modules can be configured additionally for each card. The board is supported by NE40E since V600R005C00.

03030LXH CR5D00L4XX70

4-Port 10GBase LAN/WAN-XFP Flexible Card(P40,Occupy one sub-slot)

03030LYU

20-Port 1000Base-X-SFP Flexible Card E(P40-E)

Each subcard requires an LPUF-40 subcard slot. Supports traffic control management. The SFP optical module is required additionally. At most 20 SFP optical modules can be configured for each subcard. SFP modules with electrical interfaces can be configured. SFP modules with 10M/100M/1000M electrical interfaces can be inserted into ports. The LPUF-40 board with 5A configuration can be equipped with 10 electrical interface SFP modules at most. The LPUF-40 board with 7A configuration supports full 20 electrical interface SFP modules. The 100M SFP optical module is supported and each subcard can be installed with 20 100M SFP optical modules. The board is supported by NE40E since V600R005C00.

CR5D0EEGFE70

03030MGC

2-Port 10GBase LAN/WAN-XFP Flexible Card E(P40-E) CR5D0L2XXE70

Each subcard requires an LPUF-40 subcard slot. Supports traffic control management. At most two XFP optical modules can be prepared additionally for each card. The board is supported by NE40E since V600R005C00.

4 Configuration Notes of the LPUF-100: The LPUF-100 is a 100G flexible card platform and supports a maximum bandwidth of 100 Gbit/s.The LPUF-100 provides four subcard

slots and supports the mixed configuration of subcards of various types. In addition, the LPUF-10 supports hot swap of subcards. The LPUF-100 supports services such as L3VPN, MVPN, and IPV6 enhanced.
BOM Number 03053589 CR5DLPUFA070 SBOM Type Description NetEngine40E,CR57LPUF10 1A0,100Gbps Flexible Card Line Processing Unit(LPUF-100,4 sub-slots) 5-Port 10GBase LAN/WAN-XFP Flexible Card A(P100-A,Supporting 1588v2,Occupy two sub-slots) Remarks Provides four subcard slots and supports the hot swap of subcards. Preferred; Supports services such as L3VPN, MVPN, and IPV6 enhanced. It occupies two LPUF-100 subcard slots. The XFP optical module is required additionally. At most five XFP optical modules can be installed on each board. All interfaces support 1588v2. The board is supported by NE40E since V600R003. 03030MXA CR5D00EMGF72 48-Port 100/1000Base-X-CSFP Flexible Card(P100,Occupy two sub-slots) It occupies two LPUF-100 subcard slots. The CSFP single-fiber bidirectional optical module(34060525)is required additionally. At most 24 CSFP single-fiber bidirectional optical modules can be installed on each board. The board is supported by NE40E since V600R003. 03030NCF CR5D00EFGF70 24-Port 100/1000Base-X-SFP Flexible Card(P100,Occupy two sub-slots) It occupies two LPUF-100 subcard slots. The SFP optical module is required additionally. At most 24 SFP optical modules can be installed on each board. SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard. Supported by V600R003 and later versions. The board is supported by NE40E since V600R003. 03030MXC CR5D0L5XFB70 5-Port 10GBase LAN/WAN-SFP+ Flexible Card B(P100-B,Occupy two sub-slots) 1-Port OC-768c/STM-256c POS-2KM-LC Flexible Card(P100,2 sub-slots) 2-Port OC-192c/STM-64c POS-XFP Flexible Card(P100,Occupy one sub-slot) It occupies two LPUF-100 subcard slots. SFP+ optical module is required additionally. At most five SFP+ optical modules can be installed on each board. No need SFP modules.

03030MXM

CR5D0L5XXA70

03030MXN

CR5D00P1MZ70

03030MXQ

CR5D00P2XX70

It occupies one LPUF-100 subboard slot. XFP optical modules need to be configured additionally and it can be equipped with a maximum of two XFP optical modules. The subboard needs to be configured with guide rails and blank fillers. BOM No. of the 1/4-width blank filler: 21136332 BOM number of the guide rail: 21122042

55.5.5 Configuration Notes of the LPUI: The integrated LPU is not a flexible LPU. The integrated LPU includes the 100G LPUI-100 and 40G LPUI-41.

BOM Number 03053481

SBOM Type CR5D0LAXXA70

Description NetEngine40E,CR57L5XFA0 ,5-Port 10GBase LAN/WAN-SFP+ Flexible Card B(P100-B,Occupy two sub-slots) NetEngine40E,CR57EDXFB 0,16-Port 10GBase LAN-SFP+ Integrated Line Processing Unit (LPUI-100)

Remarks The line-rate forwarding capability is 100 Gbit/s; The XFP optical module is required additionally. At most 10 XFP optical modules can be installed on each board. Converge the 160G board to the 80G board; The SFP+ optical module is required additionally. At most 16 SFP+ optical modules can be installed on each board. The line-rate forwarding capability is 40 Gbit/s; The XFP optical module is required additionally. At most eight XFP optical modules can be installed on each board. The line-rate forwarding capability is 40 Gbit/s; The XFP optical module is required additionally. At most four XFP optical modules can be installed on each board. The line-rate forwarding capability is 50 Gbit/s; The SFP optical module is required additionally. At most 48 SFP optical modules can be installed on each board. SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard. The CR57EMGFB0 supports 100M SFP optical modules and each board can be installed with 48 100M SFP optical modules.

03053480

CR5D00EDXF70

03053421

CR5D00L8XX70

NetEngine40E,CR57L8XXB0 ,8-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41) NetEngine40E,CR57L4XXB0 ,4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41) NetEngine40E,CR57EMGFB 0,48-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41)

03053422

CR5D00L4XX71

03053423

CR5D00EMGF70

03053420

CR5DL2XEFG70

NetEngine40E,CR57L2XEF GB0,2-Port 10GBase LAN/WAN-XFP+24-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41)

The line-rate forwarding capability is 50 Gbit/s; The XFP optical module is required additionally. At most two XFP optical modules can be installed on each board. The SFP optical module is required additionally. At most 24 SFP optical modules can be installed on each board. SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.

03053542

CR5D0L4XXA70

NetEngine40E,CR57L4XXC 0,4-Port 10GBase LAN/WAN-XFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)

The line-rate forwarding capability is 50 Gbit/s; The XFP optical module is required additionally. At most four XFP optical modules can be installed on each board.

03053543

CR5D0EKGFA70

NetEngine40E,CR57EKGFC 0,40-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)

The line-rate forwarding capability is 50 Gbit/s;The SFP optical module is required additionally. At most 40 SFP optical modules can be installed on each board. SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard. The line-rate forwarding capability is 50 Gbit/s; The XFP optical module is required additionally. At most two XFP optical modules can be installed on each board. The SFP optical module is required additionally. At most 20 SFP optical modules can be configured for each board. SFP modules with 10M/100M/1000M electrical interfaces can be installed on the subcard.

03053544

CR5DL2XEEG7A

NetEngine40E,CR57EKGFC 0,40-Port 100/1000Base-X-SFP Integrated Line Processing Unit (LPUI-41,Supporting 1588v2)

The LPUI-100 can only be used on the NE40E-X8/X16, and must be used with the 200G MPU and 200G SFU. CR5D0SRUA570(03053549) and CR5DSFUIE07C (03053548) are needed on NE40E-X8; CR5DSFUIE07B (03053547) is needed on the NE40E-X16.

3 Special Service Boards


NE40E provides multiple types of services boards.
BOM Number 03030LXJ SBOM Type CR53-SPU-C Description Remarks

NetEngine80E,CR53SPUCC0,Versatile The SPU does not provide Service Process Unit C interfaces to connect to external interfaces. You can configure different licenses for different services.

03053128

CR5MVSUF1010 NetEngine80E, CR52VSUF10, Flexible The VSUF does not provide Card Versatile Service Unit interfaces to connect to external 10(VSUF-10) interfaces. You can configure different licenses for different services. The flexible card is supported in V600R002C02 and later versions. CR5DVSUI201A (VSUI-20-A) The board is supported since V600R005C00.

0305G062

4 Software, License
DescriptionStarting from V300R003, the NE40E/80E adopts the License-based sale strategy. The general principle is as follows: 1. Base package The base package is mandatory item to be purchased for the NE40E/80E of each version, especially at a new site.

2. Feature license Feature licenses are controlled and are sold according to the features required by customers. Feature licenses of the NE40E/80E are classified into device licenses and board licenses. For device licenses, each device needs to be configured with one device license, for example, a 1588v2 Function License for the 1588v2 feature. For board licenses, each board needs to be configured with one license, for example, the LPUF-40-B Upgrade to LPUF-40-A License. 3. Upgrade fee If customers attempt to upgrade the earlier versions to use new features, they need to pay the upgrade fee. For upgrades on Huawei's account, such as bug fixing or contract obligation, the upgrade fee is charged as required. Software sale strategies may be adjusted. For detailed information about licenses on sale, refer to the latest Quoter-d system.
BOM Number 88030YTE 81400135 88030BUW SBOM Type CR5S40BS6500 SWP-CR53LIC-V3R3Update CR5S40EF0000 Description NetEngine40E&80E basic software,VRP5, V600R005 Remarks Must be purchased for a new site.

SWP-CR53LIC-V3R3Update NetEngine80E/40E V300R003 upgrade CR5S40EF0000 Software enhancement fee for upgrading the NE40E/80E from Rn to R(n+1).

81400189 82400144

CR5S40CLCK00 CR5S40BTOA00

NetEngine40E&80E 1588v2 It is a device license. Function License NetEngine40E&80E It is a board license. LPUF-40-B Upgrade to LPUF-40-A License (L3VPN, Ability of MVPN, IPv6 Enhanced) NetEngine80E/40E LPUF-21/20-B Upgrade to LPUF-21/20-A License (IPv6, L3VPN, MVPN) It is a board license.

82400189

SWP-CR52LIC-21BToA

82400137

SWP-CR53LIC-NetStream-SPUC NetEngine80E/40E NetStream License for SPUC SWP-CR53LIC-MVPN-SPUC SWP-CR53LIC-Tunnel-SPUC NetEngine80E/40E MVPN License for SPUC

Each SPUC requires one.

82400141 82400140

Each SPUC requires one.

NetEngine80E/40E Tunnel Each SPUC requires one. (GRE, Lawful interception, 4 over 6, etc.) License for SPUC Resource, NetEngine40E&80E, LCR5VIDE00, NetEngine40E&80E Video Enhanced Function License NE40E&80E NAT License for SPUC Each VSUF-10 requires one.

82400204

CR5S40VIDE00

82400205

CR5S40SNAT00

Each SPUC requires one.

81400208 82400207

CR5S40MHAG00 CR5S40BRAS00

NE40E&80E Cross-chassis HAG Function License NE40E&80E PPPoE/IPoE Function License for LPUF-21 NE40E&80E PPPoE/IPoE Function License for LPUF-40 NetEngine40E&80E L2TP Function License NetEngine40E&80E Lawful Interception Function License NetEngine40E&80E DAA Function License

It is a device license. Each LPUF-21 requires one.

82400208

CR5S40BRAS01

Each LPUF-40 requires one.

81400210 81400281

CR5S40L2TP00 CR5S4000LI00

It is a device license. It is a device license.

81400279 81400285 82400240 82400220

CR5S400DAA00 CR5S400MDI00 CR5S40NATS00 CR5S400DPI00

It is a device license.

NetEngine40E&80E Video It is a device license. Monitoring Function License NetEngine40E&80E 2M NAT Session License NetEngine40E&80E DPI Function License for VSUF-10 NetEngine40E&80E DPI Signature Database Upgrading Annual Fee It is a device license. Each VSUF-10 requires one

82400247

CR5S40DUAF00

It is a device license.

5 Electrical or Optical Modules


NE40E provides multi electrical and optical Modules.
Bom 3406028 7 3406027 6 3406028 1 3406028 2 3406028 7 3406029 9 3406030 0 3406030 1 Description Optical Transceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km Optical Transceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km Optical Transceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km Optical Transceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km Optical Transceiver,SFP,1310nm,STM1,-19~-14dBm,-30dBm,LC,MM,2km Optical Transceiver,eSFP,1310nm,STM1,-15~-8dBm,-31dBm,LC,SM,15km Optical Transceiver,eSFP,1310nm,STM1,-5~0dBm,-37dBm,LC,SM,40km Optical Transceiver,eSFP,1550nm,STM1,-5~0dBm,-37dBm,LC,SM,80km Mode Multimo de Single mode Single mode Single mode Multimo de Single mode Single mode Single mode Remarks Recommended Recommended Recommended Recommended Recommended Recommended Recommended Recommended

3406055 5 3406030 2 3406030 3 3406030 4 3406028 6 3406021 9 3406029 8 3406006 9 3406027 4 3406029 5 3410008 0 3406047 3 3406036 0 3406035 1 3406035 0 3406031 5 3406033 2 3406034 6 3406034 7 3406034 8

BiDi Transceiver,CSFP,1550(Tx) / 1310(Rx)nm,125~155Mbps,-14dBm,-8dBm,-28.2dBm,LC,SM,10km Optical Transceiver,eSFP,1310nm,STM4,-15~-8dBm,-31dBm,LC,SM,15km Optical Transceiver,eSFP,1310nm,STM4,-3~2dBm,-30dBm,LC,SM,40km Optical Transceiver,eSFP,1550nm,STM4,-3~2dBm,-30dBm,LC,SM,80km Optical Transceiver,eSFP,850nm,2.125Gb/s(Multi rate) ,-9.5~-2.5dBm,-17dBm,LC,MM,0.5km Optical transceiver,eSFP,1310nm,1.25Gb/s,-9.5~-3dBm,-20dBm,LC,SM,10k m Optical Transceiver,eSFP,1310nm,1.25Gb/s,-5~0dBm,-23dBm,LC,SM,40km Optical Transceiver,SFP,1550nm,1.25Gb/s,1dBm,-4dBm,-21dBm,LC(-40~85) ,40km Optical Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km Optical Transceiver,eSFP,1550nm,1.25Gb/s,0~5dBm,-30dBm,LC,SM,100km Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFP Module, Auto Negotiate, Maximum Transmission Distance 100m Optical transceiver,eSFP,1310nm,1.25Gb/s,-9~-3dBm,-20dBm,LC,Single Mode,10km Optical Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,LC,SM,80km Optical transceiver,eSFP,1471nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical transceiver,eSFP,1491nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical transceiver,eSFP,1511nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical transceiver,eSFP,1531nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical transceiver,eSFP,1551nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical transceiver,eSFP,1571nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical transceiver,eSFP,1591nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m

Single mode Single mode Single mode Single mode Multi-m ode Single mode Single mode Single mode Single mode Single mode

Recommended Recommended Recommended Recommended Recommended Sales restricted

Recommended Recommended

Sales restricted Recommended Recommended

Single mode Single mode Single mode Single mode Single mode Single mode Single mode Single mode Single mode

Recommended

Recommended

3406034 9 3410008 0 3406047 0

Optical transceiver,eSFP,1611nm,1.25Gb/s,5dBm,0dBm,-23dBm,LC,SM,70k m Optical Function Module,1000BASE-T,RJ45 Electrical Interface SFP Module, Auto Negotiate, Maximum Transmission Distance 100m Optical Transceiver,ESFP,Tx1310/Rx1490,1.25Gb/s,-3dBm,-9dBm,-19.5dBm ,LC,Single Mode,10km

Single mode RJ45 Single mode Recommended It must be used with the optical module with the BOM number being 34060475. It must be used with the optical module with the BOM number being 34060470. It must be used with the optical module with the BOM number 34060470. Recommended Recommended Recommended Sales restricted. Recommended Applied to the 10 GBase LAN only Applied to the 10 G POS, 10 GBase LAN, and 10 GBase WAN Applied to the 10 G POS, 10 GBase LAN, and 10 GBase WAN Applied to the 10 G POS, 10 GBase LAN, and 10 GBase WAN Can only be used in the 10GBase LAN. Can only be

3406047 5

Optical Transceiver,ESFP,Tx1490/Rx1310,1.25Gb/s,-3dBm,-9dBm,-19.5dBm ,LC,Single Mode,10km

Single mode

3406052 5

Integrated Optical Transmitting and Receiving Module,CSFP,Transmitting:1490nm,Receiving:1310nm,1.25Gb/s,-9.0 dBm,-3.0dBm,-19.5dBm,LC,10km

Single mode

3406028 8 3406027 8 3406028 9 3406027 9 3406048 8 3406036 2 3406031 3

Optical Transceiver,eSFP,1310nm,STM16,-10~-3dBm,-21dBm,LC,SM,2km Optical Transceiver,eSFP,1310nm,STM16,-5~0dBm,-21dBm,LC,SM,15km Optical Transceiver,eSFP,1310nm,STM16,-2~3dBm,-29dBm,LC,SM,40km Optical Transceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km Optical Transceiver,eSFP,1550nm,STM16,-2~3dBm,-30dBm,LC,SM,80km Optical Transceiver,XFP,850nm,10.3Gb/s,-7.3dBm,-1.3dBm,-7.5dBm,LC,MM, 0.3km Optical Transceiver,XFP,1310nm,9.95~10.71Gb/s,-6dBm~-1dBm,-14.4dBm,L C,SM,10km

Single mode Single mode Single mode Single mode Single mode Multimo de Single mode

3406032 2

Optical Transceiver,XFP,1550nm,9.95Gb/s to 11.1Gb/s,+2dBm,-1dBm,-15dBm,LC,Single-mode,40km

Single mode

3406036 1

Optical transceiver,XFP,1550nm,9.95Gb/s to 11.1Gb/s,0~4dBm,-24dBm,LC,Single-mode,80km

Single mode

3406049 4 3406049

XFP|SFP+ Optical transceiver,SFP+,850nm,10Gb/s,-7.3~-1dBm,-11.1dBm,LC, MM,0.3km XFP|SFP+ Optical

Multi-m ode Single

5 3406051 8

transceiver,SFP+,1310nm,10Gb/s,-8.2~0.5dBm,-12.6dBm,LC,SM,10k m XFP|SFP+ Optical transceiver,SFP+,1550nm,9.95~11.1Gb/s,-4.7~4dBm,-14.1dBm,LC,S M,40km

mode Single mode

used in the 10GBase LAN. Can be used in the 10G POS, 10GBase LAN, and 10GBase WAN.. Can only be used in 10GBase-CFP interfaces..

3406057 0

High Speed Transceiver,CFP-1295nm 1300nm 1304nm 1309nm-103.125Gbps--4.3dBm-4.5dBm--8.6dBm-SC-SMF-10km

singlemode

6 Combinet
1 Combinet An assembly cabinet is optional. According to customers' requirements, an NE40E/80E can be installed in an assembly cabinet or in the cabinet provided by the customer, or directly used without being installed in a cabinet.
BOM 02113041 SBOM Type CR52-22-D Description NE80E,CR5B2N68E,2. 2m Router Assembly Cabinet with Double Swing Doors,N68E-22 Remarks Applicable for NE40E-X3, NE40E-X16, and NE40E-X8

7 External Cable Suites


1 Configuration Notes of Power Cables Configuration notes of external cables and terminals of the NEPS3000-D
Length in Site Survey BOM Number Equal to or shorter than 25 m 25030101 Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV)25mm^2,Blue,110A Configuration Notes Each power module is equipped with one cable of this type. The cable length is determined by the site survey result. Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.

25030432

Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A

14170121

Naked Crimping Each cable is equipped with one connector,JG2,25mm^2,M8,150A,Si terminal of this type, which is lver Plated used to connect to the power module. Naked Crimping Terminal,OT,25mm^2,M8,Tin Each cable is equipped with one terminal of this type, which is

14170060

Length in Site Survey BOM Number

Configurations of External Cables and Terminals Description Plating,Naked Ring Terminal Configuration Notes used to connect to the power distribution frame. Each power module is equipped with one cable of this type. The cable length is determined by the site survey result. Each power module is equipped with one cable of this type. The cable length is determined by the site survey result.

Longer than 25 m and equal to or shorter than 35 m

25030199

Wire,450/750V,227 IEC 02(RV),35mm^2,Blue,135A

25030420

Wire,450/750V,227 IEC 02(RV),35mm^2,Black,135A

14170128

Naked Crimping Each cable is equipped with one Connector,JG2,35mm^2,M8,210A,T terminal of this type, which is in Plating,For OEM used to connect to the power module. Naked Crimping Terminal,OT,35mm^2,M8,Tin Plating,Naked Ring Terminal Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.

14170063

Longer than 35 m

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NEPS5000-D


Length in the Site Survey BOM Number Equal to or shorter than 25 m 25030430 Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A Naked Crimping Terminal,OT,16mm^2,M6,Tin Plating,Naked Ring Terminal Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A Naked Crimping Terminal,OT,25mm^2,M6,Tin Plating,Width Less Than 12.4mm,For OEM Naked Crimping Terminal,OT,25mm^2,M8,Tin Configuration Notes Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power module. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame. Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power module. Each cable is equipped with one terminal of this type, which is used to connect to the

25030428

14170020

14170024

Longer than 25 m and shorter than 35 m

25030101

25030432

14170147

14170060

Plating,Naked Ring Terminal Longer than 35 m

power distribution frame.

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NEPS8000-D


Length in the Site Survey BOM Number Equal to or shorter than 25 m 25030430 Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A Naked Crimping Terminal,OT,16mm^2,M6,Tin Plating,Naked Ring Terminal Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A Naked Crimping Terminal,OT,25mm^2,M6,Tin Plating,Width Less Than 12.4mm,For OEM Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal Configuration Notes Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power module. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame. Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each power module is equipped with three cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power module. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.

25030428

14170020

14170024

Longer than 25 m and shorter than 35 m

25030101

25030432

14170147

14170060

Longer than 35 m

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the AC power NEPS3000-A


BOM Number 25030422 Description Power Cable,300/500V,227IEC10(BVV),Black(Cores: Blue,Brown,Yellow/Green),36A,3*6mm^2 Naked Crimping Terminal,OT,6mm^2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow Naked Crimping Terminal,OT,6mm^2,M4,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow Configuration Notes Each power module is equipped with one cable of this type. The cable length is determined by the site survey result. Each cable is equipped with three terminals of this type, which are used to connect to the power distribution frame. Each cable is equipped with three terminals of this type, which are used to connect to the power module.

14170013

14170017

Configuration notes of external cables and terminals of the AC power NEPS5000-A


BOM Number 25030463 Description Power Cable,300/500V,227IEC10(BVV),10mm^2,Black Jacket(Cores: Blue,Brown,Black,Yellow/Green),46A,4 Equivalent Cores Chinese AC Power Cable 220V16A,3m,3*2.5mm^2,Black,I-Type Angle Plug,227IEC53-2.5^2(3C),C19 Straight Connector Configuration Notes Each power module is equipped with one cable of this type, which is used to connect the AC power distribution frame and power distribution box. Each power module is equipped with three cables of this type, which are used to connect the power distribution box and the input terminal of the AC power module. Each device is equipped with 1 pcs. The price of this item needs to be separately quoted. Each cable (25030463) is equipped with three terminals of this type, which are used to connect the input terminal of the power distribution box. Each cable (25030463) is equipped with three terminals of this type, which are used to connect the AC power distribution frame. Each cable (04043396) is equipped with three terminals of this type, which are used to connect the output terminal of the power distribution box.

04043396

02120415

NetEngine5000E,CR5E3TSR,AC Distribution Frame for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2 Poles 20A Air Switch Common Terminal,Single Cord End Terminal,Conductor Cross Section 10mm^2,50A,Insertion Depth 18mm,Ivory Naked Crimping Terminal,OT,10mm^2,M6,Tin Plating,Naked Ring Terminal

14170146

14170016

14170098

Common Terminal,Single Cord End Terminal,Conductor Cross Section 2.5mm^2,12.5A,Insertion Depth 8mm,Blue

Configuration notes of external cables and terminals of the NE40E-X3 DC chassis


Length in the Site Survey BOM Number Equal to or shorter than 15 m 25030430 Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A Configuration Notes Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.

25030428

14170116

Naked Crimping Each cable is equipped with one Connector,JG2,16mm^2,M6,95A,T terminal of this type, which is used to in Plated,for OEM connect to the PEM. Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame. Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.

14170024

Longer than 15 m 25030101 and shorter than 35 m

Length in the Site Survey BOM Number 25030432

Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A Configuration Notes Each DC chassis is equipped with two cables of this type. The cable length is determined by the site survey result.

14170119

Naked Crimping Each cable is equipped with one Connector,JG2,25mm^2,M6,150A, terminal of this type, which is used to Tin Plating,For OEM connect to the PEM. Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.

14170060

Longer than 35 m

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables of the NE40E-X3 AC chassis


BOM Number 04000104 Description External Suite, Power Cords All Over The World, Class I Equipment With Connector C13,External Cable Set Configuration Notes Different cables are used in different countries. Each AC chassis is equipped with 2 pcs.

Rules for selecting the AC power cable for the NE40E-X3 are as follows: 1. AC power cables are selected according to local cable standards in the country where the device is deployed. 2. The required length of the power cables is determined based on the length in the site survey. 3. The following formulas are used to calculate the number of required power cables: Number of power cables of each type = 2 pcs x Number of devices In the 100V/110V/120V AC power supply system, input of double live wires is required. In this case, the input voltage ranges from 176 VAC to 275 VAC, and any two phases can be input to the AC power module. In the external cable suite (04000104), the C13-end of the three-core power cable has three terminals marked L, N, and PE. L stands for live wire 1; N stands for live wire 1; PE stands for the ground wire. The other end of the three-core power cable must be cut off for cable making. The terminal is specified in the site survey. In the 100V/110V/120V AC power supply system, if input of double live wires cannot be provided, the NE40E-X3 AC chassis is not recommended.

Configuration notes of external cables and terminals of the NE40E-X8 DC chassis

Length in the Site Survey BOM Number Equal to or shorter than 15 m 25030430

Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A Configuration Notes Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame. Each cable is equipped with one terminal of this type, which is used to connect to the PEM. Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame. Each cable is equipped with one terminal of this type, which is used to connect to the PEM. Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.

25030428

Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A

14170024

Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal Naked Crimping Connector,JG2,16mm^2,M6,95A,Tin Plated,for OEM Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A

14170116

Longer than 15 m and shorter than 25 m

25030101

25030432

Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A

14170060

Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM Wire,450/750V,227 IEC 02(RV),35mm^2,Blue,110A

14170119

Longer than 25 m and shorter than 35 m

25030199

25030420

Wire,450/750V,227 IEC 02(RV),35mm^2,Black,110A

14170159

Naked Crimping Each cable is equipped with one Connector,JG2,34.3mm^2,M6(1/4"),13 terminal of this type, which is used 4A,Tin Plated,2AWG,Hole Center to connect to the PEM. Distance 15.875mm(5/8"),Short Tube,for North American Naked Crimping Terminal,OT,35mm^2,M8,Tin Plating,Naked Ring Terminal Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.

14170063

Longer than 35 m

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NE40E-X8 in AC

power supply mode


Length in the Site Survey BOM Number The distance between the NE40E-X8 chassis and the AC-DC converter is equal to or shorter than 3 m. 25030430 Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A Configuration Notes Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with four cables of this type. The cable length is determined by the site survey result.

25030428

14170116

Naked Crimping Each cable is equipped with two Terminal,JG2,16mm^2,M6,95A, terminals of this type, which are used to Tin Plated,for OEM connect the PEM and AC-DC converter. Monitor and Alarm Each NE40E-X8 that adopts the AC Cable,3m,D9M,CC4P0.48B(S), power supply mode is equipped with D9M one monitor and alarm cable, which is used to connect the AC-DC converter and the NE40E-X8 DC chassis.

04080076

The distance between (1) the NE40E-X8 chassis (2) and the AC-DC converter is longer than 3 m. The distance between the AC-DC converter and the AC power distribution frame is equal to or shorter than 50 m.

It is recommended to deploy the AC-DC converter near the DC chassis. If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment of the AC power cable in the DC power supply system. In this case, the DC chassis cannot manage the AC-DC converter. Power Each AC chassis is equipped with Cable,300/500V,227IEC10(BVV),6 four cables of this type. mm^2,Black Jacket(Cores:Blue,Brown),43A,2 Equivalent Cores Naked Crimping Terminal,OT,6mm^2,M6,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow Naked Crimping Terminal,OT,6mm^2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC-DC converter. Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC power distribution frame.

25030461

14170023

14170013

The distance between the AC-DC converter and the AC power distribution frame is longer than 50 m.

An AC power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NE40E-X16 DC chassis

Length in the Site Survey BOM Number Equal to or shorter than 15 m 25030430

Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC 02(RV),16mm^2,Blue,85A Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A Naked Crimping Terminal,OT,16mm^2,M8,Tin Plating,Naked Ring Terminal Configuration Notes Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.

25030428

14170024

14170116

Naked Crimping Each cable is equipped with one terminal Terminal,JG2,16mm^2,M6,95A,T of this type, which is used to connect to in Plated,for OEM the PEM. Wire,450/750V,227 IEC 02(RV),25mm^2,Blue,110A Wire,450/750V,227 IEC 02(RV),25mm^2,Black,110A Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal Naked Crimping Connector,JG2,25mm^2,M6,150 A,Tin Plating,For OEM Wire,450/750V,227 IEC 02(RV),35mm^2,Blue,135A Wire,450/750V,227 IEC 02(RV),35mm^2,Black,135A Naked Crimping Connector,JG2,34.3mm^2,M6(1/ 4"),134A,Tin Plated,2AWG,Hole Center Distance 15.875mm(5/8"),Short Tube,for North American Naked Crimping Terminal,OT,35mm^2,M8,Tin Plating,Naked Ring Terminal Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame. Each cable is equipped with one terminal of this type, which is used to connect to the PEM. Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result. Each cable is equipped with one terminal of this type, which is used to connect to the PEM.

Longer than 15 m 25030101 and shorter than 35 m 25030432

14170060

14170119

Longer than 25 m 25030199 and shorter than 35 m 25030420

14170159

14170063

Each cable is equipped with one terminal of this type, which is used to connect to the power distribution frame.

Longer than 35 m

A power distribution frame or the first power cabinet of a row should be placed near the device.

Configuration notes of external cables and terminals of the NE40E-X16 in AC power supply mode
Length in the Site Survey BOM Number The distance between the 25030430 Configurations of External Cables and Terminals Description Wire,450/750V,227 IEC Configuration Notes Each DC chassis is equipped with

Length in the Site Survey BOM Number NE40E-X16 chassis and the AC-DC converter is equal to or shorter than 3 m. 25030428

Configurations of External Cables and Terminals Description 02(RV),16mm^2,Blue,85A Configuration Notes eight cables of this type. The cable length is determined by the site survey result. Each DC chassis is equipped with eight cables of this type. The cable length is determined by the site survey result.

Wire,450/750V,227 IEC 02(RV),16mm^2,Black,85A

14170116

Naked Crimping Each cable is equipped with two Terminal,JG2,16mm^2,M6,95A, terminals of this type, which are used Tin Plated,for OEM to connect the PEM and AC-DC converter. Monitor and Alarm Cable,3m,D9M,CC4P0.48B(S), D9M Each NE40E-X16 that adopts the AC power supply mode is equipped with two monitor and alarm cables, which are used to connect the AC-DC converter and the NE40E-X16 DC chassis.

04080076

The distance between the (1) It is recommended to deploy the AC-DC converter near the DC chassis. NE40E-X16 chassis and the AC-DC converter is (2) If it is difficult to deploy the AC-DC converter near the DC chassis, see the deployment longer than 3 m. of the AC power cable in the DC power supply system. In this case, the DC chassis cannot manage the AC-DC converter. The distance between the 25030461 AC-DC converter and the AC power distribution frame is equal to or shorter than 50 m. 14170023 Power Cable,300/500V,227IEC10(BVV),6 mm^2,Black Jacket(Cores:Blue,Brown),43A,2 Equivalent Cores Naked Crimping Terminal,OT,6mm^2,M6,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow Naked Crimping Terminal,OT,6mm^2,M8,Tin Plating,Insulated Ring Terminal,12~10AWG,yellow Each AC chassis is configured with four cables of this type.

Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC-DC converter. Each AC power cable is equipped with two terminals of this type on the two cores, which are used to connect to the binding post of the AC power distribution frame.

14170013

The distance between the An AC power distribution frame or the first power cabinet of a row should be placed near the AC-DC converter and the device. AC power distribution frame is longer than 50 m.

Configuration Notes of Ground Cables Configuration notes of the ground cable and terminals used on the NE40E-X3

BOM Number 25030431

Description Wire,450/750V,60227 IEC 02(RV)25mm^2,yellow green,110A

Configuration Notes Each device is equipped with one such power cable. The length of the power cable is based on the site survey result. If the device is grounded through a cabinet, the

BOM Number

Description

Configuration Notes length of the ground cable is a1 shown in ; if the device is grounded through a chassis, the length of the ground cable is a3 shown in .

14170119

Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal

One such terminal is used to connect to the ground terminal on the chassis. When a device is grounded through a chassis, one such terminal is used to connect to the ground bar in the equipment room. If a device is grounded through a cabinet, one such terminal is used to connect to the ground point on the cabinet.

14170060

Configuration notes of the ground cable and terminals used on the NE40E-X8/NE40E-X16
BOM Number 25030431 Description Wire,450/750V,60227 IEC 02(RV)25mm^2,yellow green,110A Configuration Notes Each device is equipped with one such power cable. The length of the power cable is based on the site survey result. If the device is grounded through a cabinet, the length of the ground cable is a1 shown in ; if the device is grounded through a chassis, the length of the ground cable is a3 shown in . One such terminal is used to connect to the ground terminal on the chassis. When a device is grounded through a chassis, one such terminal is used to connect to the ground bar in the equipment room. If a device is grounded through a cabinet, one such terminal is used to connect to the ground point on the cabinet.

14170119

Naked Crimping Connector,JG2,25mm^2,M6,150A,Tin Plating,For OEM Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal

14170060

Configuration Notes of Ground Cable of the EPS200-4850A The external AC-DC converter EPS200-4850A of the NE40E-X8/NE40E-X16 needs to be separately grounded. Therefore, the 25 mm^2 ground cable is needed. The below lists the configuration notes of the ground cable and terminals used on the EPS200-4850A. Configuration notes of the ground cable and terminals used on the EPS200-4850A
BOM Number 25030431 Description Wire,450/750V,60227 IEC 02(RV)25mm^2,yellow green,110A Configuration Notes Each device is equipped with one such power cable. The length of the power cable is based on the site survey result. If the device is grounded through a cabinet, the length of the ground cable is a1 shown in

; if the device is grounded through a chassis, the length of the ground cable is a3 shown in . 14170119 Naked Crimping One such terminal is used to connect to the ground Connector,JG2,25mm^2,M6,150A,Tin terminal on the chassis. Plating,For OEM Naked Crimping Terminal,OT,25mm^2,M8,Tin Plating,Naked Ring Terminal When a device is grounded through a chassis, one such terminal is used to connect to the ground bar in the equipment room. If a device is grounded through a cabinet, one such terminal is used to connect to the ground point on the cabinet.

14170060

Configuration Notes of Clock Cables List of clock cables that can be used in NE40E&80E V600R005C00

No. 1

BOM Number 04022629

Description

Length

Cable Type Cable with one SMB connector which is used to connect to the MPU/SRU. The connector on the other end of the cable must be provided by the customer.

Configuration Notes These cables are not supported on the CR52MPUD. Each CR52MPUA0/CR52SR UA0/CR52MPUB0/CR 52SRUA1 can have 0 to 4 pcs. Each CR52MPUB2/CR52SR UA3/CR56MPUB4/CR 57SRU40A4 can have 0 to 2 pcs.

Trunk 20 m Cable,20.00m,75ohm,2.2mm,SMB 75SF-V,SYFVZ75-1.2/0.25,HONE T,DL2526 Trunk 30 m Cable,30.00m,75ohm,2.2mm,SMB 75SF-V,SYFVZ75-1.2/0.25,Wirele ss Intelligent Network Trunk 40 m Cable,40.00m,75ohm,2.2mm,SMB 75SF-V,SYFVZ75-1.2/0.25,C&C0 8B,DL3133 Trunk 50 m Cable,50.00m,75ohm,2.2mm,SMB 75SF-V,SYFVZ75-1.2/0.25,C&C0 8B,DL3134 Trunk Cable,155M 5m Self-Loop,5m,75ohm,4.0mm,SMB 75SF-IV,SYV75-2/0.34(S),SMB75 SF-IV,OptiX Trunk 3m Cable,3m,120ohm,1E1,0.4mm,MP 8-II,120CC4P0.4P430U(S),MP8-II, Expert 2.0 Trunk 15 m Cable,15m,120ohm,1E1,0.4mm,M P8-II,120CC4P0.4P430U(S),MP8II Trunk 30 m Cable,30m,120ohm,1E1,0.4mm,M P8-II,120CC4P0.4P430U(S),MP8II,Expert 2.0 Trunk Cable,60.00m,120ohm,1E1,0.4m m,MP8-II,120CC4P0.4P430U(S), 60 m

04060205

04023971

04023972

04060171

Cable with two SMB connectors

04040497

Cable with RJ48 connectors

Each CR52MPUD/CR52MP UB2/CR52SRUA3/CR5 6MPUB4/CR57SRU40 A4 can have 0 to 2 pcs. These cables are not supported on the CR52MPUA0/CR52SR UA0/CR52MPUB0/CR 52SRUA1.

04040261

04040496

04040494

No.

BOM Number

Description MP8-II,Expert 2.0

Length

Cable Type

Configuration Notes

10

04040493

Trunk 80 m Cable,80m,120ohm,1E1,0.4mm,M P8-II,120CC4P0.4P430U(S),MP8II,Expert 2.0 Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014 Twisted-Pair Cable,100ohm,Category 5e UTP,0.51mm,24AWG,8Cores,PA NTONE 430U,Use with Plug:14080082 2 pcs Cable with RJ45 connectors Balanced cable These cables are optional when the clock interfaces on the CR52MPUD/CR52MP UB2/CR52SRUA3/CR5 6MPUB4/CR57SRU40 A4 support 1PPS+TOD or DCLS.

11

14080082

12

25050014

Based on the site survey result

Configuration Notes of E1/T1 Interface Cables Configurations of the conversion box and cables for the CR5M1CFE1

BOM Number 02351606

Description

Configuration Notes

NetEngine80E,CR5Z1DCRF,24*E1/T1 The conversion box of this type corresponds to one DB100 to RJ48 Port Conversion Box CR5M1CFE1 LPU. The LPU and the conversion box are connected through the 04070064 cable. The conversion box is separately packaged. NetEngine80E,CR5Z1DCRM,48*E1/T1 The conversion box of this type corresponds to two DB100 to RJ48 Port Conversion Box CR5M1CFE1 LPUs. The LPU and the conversion box are connected through two sets of 04070064 cables. The conversion box is separately packaged. NetEngine80E,CR5Z1DCSF,24*E1 DB100 to SMB Port Conversion Box The conversion box of this type corresponds to one CR5M1CFE1 LPU. The LPU and the conversion box are connected through the 04070064 cable. The conversion box is separately packaged.

02351607

02351608

04070064

Signal cable,24E1 Transit It is used to connect the E1 conversion box and E1 LPU. Cable,4m,D100M-I,3*CC16P0.4P430U Each LPU is equipped with one cable of this type. (S)-I,D100M-I

If coaxial cables with SMB connectors are used, the conversion box 02351608 must be selected. If twisted pair cables with RJ48 connectors are used, the conversion box 02351606 or 02351607 must be selected. When the interface on the CFE1 board needs to be connected to the E1 interface on another device, you need to take the matching between cable impedances into consideration when selecting a cable. 1. The peer interface (RJ48) uses the 120-ohm balanced cable.

When the remote interface uses the balanced 120-ohm twisted cable and RJ48 connector, select the E1 trunk cable from Table 8-26 based on the site survey length. The listed cables are with RJ48 connectors at both ends. E1 trunk cable list (RJ48 interface)

No. 1

BOM Number 04040497

Description

Quantity

Unit pcs

Trunk One for each E1 Cable,3m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P4 interface 30U(S),MP8-II,Expert 2.0 Trunk One for each E1 Cable,15m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P interface 430U(S),MP8-II Trunk One for each E1 Cable,30m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P interface 430U(S),MP8-II,Expert 2.0 Trunk One for each E1 Cable,60.00m,120ohm,1E1,0.4mm,MP8-II,120CC4P0. interface 4P430U(S),MP8-II,Expert 2.0 Trunk One for each E1 Cable,80m,120ohm,1E1,0.4mm,MP8-II,120CC4P0.4P interface 430U(S),MP8-II,Expert 2.0

04040261

pcs

04040496

pcs

04040494

pcs

04040493

pcs

2. The peer interface (SMB) uses the 75-ohm unbalanced cable. When the remote interface uses the SMB connector, the conversion box 02351608 should be selected for the CFE1 LPU, providing 24 SMB interfaces. Select corresponding cables from Table 8-28 based on the site survey length. In addition, the SMB trunk cable has one connector on one end, used to connect to the conversion box. The other end of the cable connected to the customer device does not have any connector, and the customers must prepare the connector themselves. In this application, the maximum transmission distance is shorter than 200 m. List of E1 trunk cables with SMB connectors
No. 1 BOM Number 04026814 Description Single Cable,120ohm,75ohm Converter Box(With SMB Socket 14040127),PCB03022834+Box Body 21210634) 1 Quantity Unit pcs

04022627

Trunk 2 Cable,10.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,HONET,W2524 Trunk 2 Cable,20.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,HONET,DL2526 Trunk 2 Cable,30.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,Wireless Intelligent Network Trunk 2 Cable,40.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,C&C08B,DL3133 Trunk 2 Cable,50.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25,C&C08B,DL3134 Trunk 2 Cable,65.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ751.2/0.25

pcs

04022629

pcs

04060205

pcs

04023971

pcs

04023972

pcs

04043079

pcs

No. 8

BOM Number 04042130

Description Trunk 2 Cable,70m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2 /0.25 Trunk 2 Cable,80m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2 /0.25 Trunk 2 Cable,90m,75ohm,2.2mm,SMB75SF-V,SYFVZ75-1.2 /0.25 Trunk Cable,100.00m,75ohm,2.2mm,SMB75SF-V,SYFVZ7 5-1.2/0.25 Trunk Cable,155M Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/ 0.34(S),SMB75SF-IV,OptiX 2

Quantity

Unit pcs

04042131

pcs

10

04042132

pcs

11

04043080

pcs

12

04060171

pcs

Configuration Notes of the E3/T3 Interface Cable List of E3 trunk cables with SMB connectors

No. 1

BOM Number 04060171

Description Trunk Cable,155M 2 Self-Loop,5m,75ohm,4.0mm,SMB75SF-IV,SYV75-2/0.34( S),SMB75SF-IV,OptiX Trunk 2 Cable,155M/Clock/Lightning,10m,75ohm,3.9mm,SMB75S F-IV,SYV75-2/0.34(S) Trunk 2 Cable,155M/Clock/Lightning,20m,75ohm,3.9mm,SMB75S F-IV,SYV75-2/0.34(S) Trunk 2 Cable,155M/Clock/Lightning,30m,75ohm,3.9mm,SMB75S F-IV,SYV75-2/0.34(S)

Quantity

Unit pcs

04044335

pcs

04044336

pcs

04044337

pcs

8 External Optical Fiber Suites


List of commonly used optical fibers in the optical fiber suite (04100069)
No. 1 2 3 4 BOM Number 14130296 14130222 14130295 14130195 Description Patch Cord,LC/PC-LC/PC,Multimode,A1b,2mm,5m Patch Cord,LC/PC-LC/PC,Multimode,2mm,10m Patch Cord,LC/PC-LC/PC,Multimode,2mm,20m Patch Cord,LC/PC-LC/PC,Singlemode,2mm,5m Quantity The type and the number of fibers depend on the site survey result. Unit pcs pcs pcs pcs

5 6 7 8 9 10 11 12 13

14130199 14130251 14130248 14130197 14130221 14130196 14130223 14130375 14130335

Patch Cord,LC/PC-LC/PC,Singlemode,2mm,10m Patch Cord,LC/PC-LC/PC,Singlemode,2mm,20m Adapter,LC/PC-LC/PC,2,Blue,Shell:Plastic,Sleeve:Zirco nia,Square Patch Cord,FC/PC,LC/PC,Singlemode,2mm,10m Patch Cord,FC/PC,LC/PC,Multimode,2mm,10m Patch Cord,LC/PC-SC/PC,Singlemode,2mm,10m Patch Cord,LC/PC-SC/PC,Multimode,2mm,10m Patch Card,MPO-MPO,Multimode,0.3m,8 Cores Ribbon Fiber Optic Fiber Connector,LC/PC,LC/PC,Multi-mode,2mm,1m

pcs pcs pcs pcs pcs pcs pcs pcs pcs

9 Accessories
List and configuration description of accessories of the NE40E-X16
No. 0 Code 21100144 Description Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire Clip-300*3.6mm-Strength 18.2kg Configuration Notes Each NE40E-X16 is configured with 200 pcs. It is not required on the NE80E. 1 21100015 Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire Strip,150*3.6mm,Strength 18.2kg Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire Strip,100*2.5mm,Strength 8.1kg It is mandatory. Each NE80E/NE40E-X16 is configured with 100 pcs. It is mandatory. Each NE80E/NE40E-X16 is configured with 100 pcs.

21100041

28010026

Insulation Material,Fireproof PVC Corrugated Tube,D2 It is optional and is provided for the NE40E/80E-16 to be delivered only outside China. It is selected based on the site survey result. By default, a 30 m tube is provided. Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014 Twisted-Pair Cable,100ohm,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Used with Plug:14080082 It is provided based on the site survey result. By default, it is not provided. It is provided based on the site survey result. By default, it is not provided.

14080082

25050014

29041060

Engineering/Blank label,Engineering label,Signal Cable It is mandatory. Each label,30 Groups,10 Array,3 Row,Height 22.0,Width NE80E/NE40E-X16 is configured 84.0,Matte White,1Pcs/Group with 6 pcs. DKBA4.150.0999MX,Cabinet LOGO,Router,90mm*30mm,Plastic It is mandatory when a cabinet is delivered. Each NE80E/NE40E-X16 is configured with 2 pcs.

29042491

No. 8

Code 02234474

Description NetEngine5000E,Engineering Required Delivery Accessory Per Integrated Chassis

Configuration Notes It is mandatory. Each NE80E/NE40E-X16 is configured with 1 pcs.

21500093

Q/DKBA4.127.0355MX,Side Hang FMTs,NGN Cabinet It is mandatory when a cabinet is delivered. Each NE80E/NE40E-X16 is configured with 4 pcs. Cross Recessed Pan Head Thread forming Screws,M5*10,Zinc Electroplating, iridescent yellow,GB6560-86 It is mandatory when a cabinet is delivered. Each NE80E/NE40E-X16 is configured with 8 pcs. The NE80E with the AC power supply are configured with 16 pcs. The screws are used to fix the slide rails of the AC power distribution cabinet. Each slide rail is configured with 4 pcs. There are four slide rails; therefore, the NE80E needs to be configured with 16 pcs. It is quoted separately. Each NE40E, NE40E-X3, NE40E-X8, or NE40-X16 to be delivered outside China is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required. It is quoted separately. Each NE80E is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required. It is quoted separately. Each NE80E to be delivered in China is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required. It is quoted separately. Each NE80E to be delivered outside China is configured with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required. It is quoted separately. It is mandatory when an NE40E-X16 with the AC power supply is delivered. Each NE40E-X16 is configured with 2 pcs.

10

26010552

11

31185644

HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)

12

31185645

HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)

13

31185648

HUAWEI NetEngien80E Core Router Product Documentation-(V600R005C00_01)

14

31185649

HUAWEI NetEngien80E Core Router Product Documentation-(V600R005C00_01)

15

02400376

Power Distribution Cabinet,220V,50/60HZ,72000mA,None,EPS200-4850 A

16

02130872

Power It is quoted separately. It is module--33degC-65degC-90VAC-290VAC-(-53.5)VDC mandatory when an NE80E/NE40E-X16 with the AC

No.

Code

Description /54.2A-AC/DC rectifier

Configuration Notes power supply is delivered. Each NE80E/NE40E-X16 is configured with 8 pcs. It is mandatory when an NE40E-X16 with two AC power supply cabinets is to be delivered. Each NE40E-X16 is configured with 4 pcs, with each AC power supply cabinet configured with with 2 pcs. It is quoted separately. It is mandatory when an NE80E with the AC power supply is delivered. Each NE80E is configured with 1 pcs.

17

21240150

DKBA8.201.1797,Standard Guide Rail,N68E Cabinet

18

02120415

NetEngine5000E,CR5E3TSR,AC Distribution Frame for Cabinet,2 or 6 Input,6(2*3) Output,6 Group of 2 Poles 20A Air Switch

19

05116036 05116037

NetEngine40E&80E-4/8/16, It is provided for the NE40E-8, NetEngine40E&80E-4/8/16_C V600R005C00,Physical NE40E-4, or NE80E to be Software Package,DVD China delivered outside China. Each NE40E-8, NE40E-4, or NE80E is NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_O V600R005C00,Physical configured with 1 pcs. By default, it is not provided. Software Package,DVD Oversea NetEngine40E-X8/X16,NetEngine40E-X8/X16_C V600R005C00,Physical Software Package, DVD China NetEngine40E-X8/X16,NetEngine40E-X8/X16_O V600R005C00,Physical Software Package, DVD Oversea It is mandatory. Each NE80E is configured with 1 pcs.

20

05116038 05116039

21 22 23 25

28040011 28040009 28040013 02120641

Heat shrink tube/D11/Radial Shrinkage Ratio>50%/Black Heat shrink tube,D14,Radial Shrinkage Ratio>50%,Black Heat Shrink Tube/D18/Radial Shrink Rate>50%/Black

The insulated heat shrink tube is selected according to 0. The insulated heat shrink tube is selected according to 0. The insulated heat shrink tube is selected according to 0.

Power Distribution Box,NE40E,DPD300-4-12,Dual-two It is configured based on the site Inputs .Dual-six outputs ,High Power DC Distribution survey result. When customers Box,per output 80A cannot provide 12 power channels for the NE40E/80E-X16/-16, a power distribution is required. Customers need to purchase power cables for the power distribution box. Each Power distribution box can support one NE40E/80E-X16/-16. DKBA61533919,X8 Mount_19inch,NE40E DKBA61532828,X8 Mount_23inch,NE40E It is mandatory for the NE40E-X8 (02354085) and NE40E-X16(02354084) to be delivered to the North America market. An NE40E-X8 is configured with 1 pcs and an NE40E-X16 is configured with 2 pcs.

26

21240446 21240447

List and configuration description of NE40E-X3/NE40E-X8 accessories

No. 0

Code 21100144

Description Nonmetal Parts,DKBA0.480.0457-GT-300I- Wire Clip-300*3.6mm-Strength 18.2kg Nonmetal Parts,DKBA0.480.0457-GT 150I,Wire Strip,150*3.6mm,Strength 18.2kg Nonmetal Parts,DKBA0.480.0457-GT 100M,Wire Strip,100*2.5mm,Strength 8.1kg Network Interface Connector,8Bit 8Pin,Crystal Plug,Matching 25050014 Twisted-Pair Cable,100ohm,Category 5e UTP,0.51mm,24AWG,8Cores,PANTONE 430U,Use with Plug:14080082 Insulation Material,Fireproof PVC Corrugated Tube,D25

Configuration Notes Each NE40E-X8 is configured with 100 pcs. It is not required by other devices. It is mandatory. Each NE40E-X8 is configured with 100 pcs. It is mandatory. Each NE40E-X8 is configured with 100 pcs. It is provided based on the site survey result. By default, it is not provided. It is provided based on the site survey result. By default, it is not provided. It is optional and is provided for the NE40E-X8 to be delivered only outside China. It is selected based on the site survey result. By default, a 30 m tube is provided. It is mandatory. Each NE40E-X8 is configured with 4 pcs. It is mandatory when a cabinet is delivered. Each NE40E-X8 is configured with 2 pcs. It is quoted separately. Each NE40E, NE40E-X3, NE40E-X8, or NE40-X16 to be delivered inside China is provided with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required. It is quoted separately. Each NE40E, NE40E-X3, NE40E-X8, or NE40-X16 to be delivered outside China is provided with 1 pcs. This CD-ROM applies to only a router running V600R005C00; for a router running another version, an appropriate CD-ROM is required. It is mandatory. Each NE40E-X8 is configured with 1 pcs. It is mandatory when a cabinet is delivered. Each NE40E-X8 is configured with 2 pcs. It is mandatory when a cabinet is delivered. Each NE40E-X8 with the DC power supply is configured with 4 pcs. Each NE40E-X8 with the AC power supply is configured with 8 pcs.

1 2 3

21100015 21100041 14080082

25050014

28010026

29041060

Engineering/Blank label,Engineering label,Signal Cable label,30 Groups,10 Array,3 Row,Height 22.0,Width 84.0,Matte White,1Pcs/Group DKBA4.150.0999MX,Cabinet LOGO,Router,90mm*30mm,Plastic HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)

29042491

31185644

31185645

HUAWEI NetEngien40E Universal Service Router Product Documentation-(V600R005C00_01)

10 11

02234474 21500093

NetEngine5000E,Engineering Required Delivery Accessory Per Integrated Chassis Q/DKBA4.127.0355MX,Side Hang FMTs,NGN Cabinet Cross Recessed Pan Head Thread forming Screws,M5*10,Zinc Electroplating, iridescent yellow,GB6560-86

12

26010552

13

02400376

Power Distribution It is quoted separately. It is Cabinet,220V,50/60HZ,72000mA,None,EPS200-485 mandatory on an NE40E-X8 with

No.

Code 0A

Description

Configuration Notes the AC power supply. Each NE40E-X8 is configured with 1 pcs.

14

02130872

Power It is quoted separately. It is module--33degC-65degC-90VAC-290VAC-(-53.5)VD mandatory on an NE40E-X8 with C/54.2A-AC/DC rectifier the AC power supply. Each NE40E-X8 is configured with 4 pcs. It is not provided for other cabinets. DKBA8.201.1797,Standard Guide Rail,N68E Cabinet It is mandatory for an NE40E-X8 with the AC power supply. Each NE40E-X8 is configured with 2 pcs for installing the AC-input cabinet. NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_C V600R005C00,Physical Software Package,DVD China NetEngine40E&80E-4/8/16, NetEngine40E&80E-4/8/16_O V600R005C00,Physical Software Package,DVD Oversea It is applicable to the NE40E-8/-4 and NE80E and sold based on versions. By default, it is not delivered with the router.

15

21240150

16

05116036 05116037

05116038 05116039

NetEngine40E-X8/X16,NetEngine40E-X8/X16_C V600R005C00,Physical Software Package, DVD China NetEngine40E-X8/X16,NetEngine40E-X8/X16_O V600R005C00,Physical Software Package, DVD Oversea

It is applicable to the NE40E-X8/-X16 and sold based on versions. By default, it is not delivered with the router.

05116040 05116041

NetEngine40E-X3,NetEngine40E-X3_C V600R005C00,Physical Software Package,DVD China NetEngine40E-X3,NetEngine40E-X3_O V600R005C00,Physical Software Package,DVD Oversea

It is applicable to the NE40-X3 and sold based on versions. By default, it is not delivered with the router.

19

21500182

DKBA4.150.0747MX,Mount Angle,NE20-4(3U) Chassis of NGN DKBA4.150.0546MX,Mount Angle Component,NE40E DKBA4.150.0923MX,Mount,NE40E-4 Heat shrink tube/D11/Radial Shrinkage Ratio>50%/Black Heat shrink tube,D14,Radial Shrinkage Ratio>50%,Black Heat Shrink Tube/D18/Radial Shrink Rate>50%/Black Power Distribution Box,NE40E,DPD300-4-12,Dual-two Inputs .Dual-six outputs ,High Power DC Distribution Box,per output 80A

It is mandatory. Each 20 U NE40E-8 (02351014) is configured with 1 pcs. It is mandatory. Each 22 U NE40E-8 (02350762) is configured with 1 pcs. It is mandatory. Each NE40E-4 is configured with 1 pcs. The insulated heat shrink tube is selected according to 0. The insulated heat shrink tube is selected according to 0. The insulated heat shrink tube is selected according to 0. It is configured based on the site survey result. When customers cannot provide six power channels for the NE40E/80E-X8/-8, a power distribution is required. Customers need to purchase power cables for the power distribution box. Each power distribution box can support a maximum of two

20

21500200

21 22 23 24 25

21240160 28040011 28040009 28040013 02120641

No.

Code

Description

Configuration Notes NE40E/80E-X8/-8s.

26

21240442 21240443

DKBA61532830,X3(DC) Mount_19inch,NE40E DKBA61532826,X3(DC) Mount_23inch,NE40E

It is designed exclusively and mandatory for the NE40X3-DC chassis (0235****) to be delivered to the North America market. It is designed exclusively and mandatory for the NE40X3-DC chassis (02354559) to be delivered to the North America market. It is designed exclusively and mandatory for the NE40E-X8 (02354085) and NE40E-X16(02354084) to be delivered to the North America market. An NE40E-X8 is configured with 1 pcs and an NE40E-X16 is configured with 2 pcs.

27

21240444 21240445

DKBA61532831,X3(AC) Mount_19inch,NE40E DKBA61532827,X3(AC)Mount_23inch,NE40E

28

21240446 21240447

DKBA61533919,X8 Mount_19inch,NE40E DKBA61532828,X8 Mount_23inch,NE40E

Insulated heat shrink tubes on different chassis/core diameters of power cables


Cable Diameter Code of an Insulated Heat Shrink Tube 28040011 28040009 28040013

Length of an Insulated Shrink Tube (cm)


NE40E-X16 150 150 150 NE40E-X8 100 100 100

Heat

NE40E-X3 50 50

16mm2 25mm2 35mm2

S-ar putea să vă placă și