Sunteți pe pagina 1din 1

LOAD CALCULATIONS

Job No. Project Clint Description

: : : :

Rev. No. Date Designed by Checked by

LOADS APPLIED ON THE MAIN FRAME-1

: : : :

R0 27/01/2014 SANDEEP

Building Type
Length (o/o) Width (o/o) Width module Bay spacing Clear eave height Max. eave height Roof slope () Wt. of sheet & purline Dead Load (DL)

=
= = = = = = = = = 82.00 m 40.50 m 7.00 7.00 8.00 5.71 m m m DEAD LOAD (DL) 15.00 Kg/m 1.05 KN/m COLLATERAL LOAD

Collateral Load on Rafter

= =

0.00 Kg/m 0.00 KN/m LIVE LOAD (LL)

Other Collateral Load

= =

0.00 Kg/m 0.00 KN/m

Live load/unit area, roof Live Load (LL)

= =

75.00 Kg/m 5.25 KN/m WIND LOAD (WL)

Basic wind speed (Vb) Design wind speed (Vz) where,

= 39 m/s = Vbxk1xk2xk3 k1 = probability factor (risk coefficient) = 1 k2 = terrain, height and structure size factor = 0.93 k3 = topography factor = 1 Vz = 36.27 m/s

Terrain Category 2

Class B

Design wind pressure (pz)

= pz =

0.6xVz 0.789 KN/m PRESURE COEFFICIENTS:~

Encloser condition of the building = Enclosed Internal pressure coeff.(Cpi) = 0.20 h/w = 0.20 = h/w<=1/2 l/w = 2.02 = 3/2<=l/w<4 External pressure coeff.(Cpe) : Wind Angle () 0 degree 90 degree

Table 4 Coeff. For Wall Left Right 0.70 -0.25 -0.50 -0.50

Table 5 Coeff. For Roof Left Right -0.9350 -0.40 -0.80 -0.80

WIND LOAD DIAGRAMS:~ Wind Across the Ridge (With -Ve Cpi) -0.74 -4.06 KN/m -0.20 Wind Across the Ridge (With +Ve Cpi) -1.14 -6.271 KN/m -0.60 KN/m -3.32

-1.11KN/m

KN/m 4.97 0.90

KN/m -0.28 -0.05

KN/m 2.76 0.50

KN/m -2.49 -0.45

Wind Parallel to Ridge(With +Ve Cpi) -1.00 -5.53 KN/m -1.00

-5.53 KN/m

KN/m -3.87 -0.70

KN/m -3.87 -0.70

Wind Parallel to Ridge(With -Ve Cpi) -0.60 -3.32 KN/m -0.60

-3.32 KN/m

KN/m -1.66 -0.30

KN/m 0.00 -0.30 Note: 1) Values within the circles are the UDL 2) -Ve value means, load applied away from structure.