Sunteți pe pagina 1din 54

Estimate (Reinforced Concrete Wall)

I.Earthworks
1.Excavation
A.for Section D
Volume=6.2(3.5)(6)+4.8(2.9)(6)+3.4(1.3)(6
=240.24cum

B.for Section C
Volume=6.2(3.5)(27)+5.7(3.4)(12)+4.7(2.8)(12)+3.7(2.2)(12)+
3.7(2.2)(12)+2.7(1.6)(12)+1.7(1)(12)
=1243.98cum

C.for Section B
Volume=6.2(24)(3.11)+5.70(12)(3.01)+5.2(3.10)(12)+4.7(2.8)(12)+4.2(2.5)(12)+3.7(2.2)(12)+3.2(
1.9)(12)+2.7(1.6)(12)+2.2(1.3)(12)+(1.7)(1)(12)+1.2(0.70)(12)+0.70(0.40)(12)
=1436.65cum
D.for Section A
Volume=6.2(12)(3.11)+4.85(12)(2.5)+3.9(12)(1.95)+3(12)(1.41)
=518.90cum

Total Volume For Excavation=

240.24cum+1243.98cum+1436.65cum+ 518.90cum
=3439.77cum

2.Backfill
A.for Section A
Volume=(5.6)(3.11)(12)+4.35(2.51)(12)+3.5(1.91)(12)+2.7(1.41)(12)
=465.92cum
Percent of Backfill=465.92/518.90cum
=0.90 say 90 % of Excavation is Backfill
B.for Section B
Volume=0.90(1436.65)
=1292.98cum
C.for Section C
Volume=0.90(1243.98cum)
=1119.58cum
D.for section D
Volume=0.90(240.24cum)
=216.22 cum
Total Volume For backfill=465.92cum+1292.98cum+1119.58cum+216.22 cum
=3094.7 cum

II.Concrete Works
1.)@ Section A
Volume of
Concrete=6.2(0.39)(12)+3.11(0.60)(12)+4.85(0.39)(12)+0.50(2.51)(12)+3.90(0.39)(12)+0.40(12)(1.91)+3(
12)(0.39)+1.41(0.30)(12)
=135.702cum
2.)@ Section B
Vol of
concrete=6.2(0.39)(24)+3.11(0.60)(24)+5.7(12)(0.39)+3.01(12)(0.55)+5.2(0.39)(12)+12(0.50)(4.81)+4.7(1
2)(0.39)+2.41(12)(0.45)+4.2(12)(0.39)+12(0.40)(2.11)+(3.7)(12)(0.39)+12(0.35)(1.81)+3.2(12)(0.39)+12(0.
30)(1.51)+2.7(12)(0.39)+12(0.25)(1.21)+2.2(12)(0.39)+12(20)(0.91)+12(1.7)(0.39)+12(0.15)(0.61)+1.2(12)
(0.39)+12(0.15)(0.31)+0.70(0.39)(12)+0.15(12)(0.10)
=556.53cum
3.)@Section C
Vol of
Concrete=6.2(27)(0.39)+27(0.60)(3.11)+5.7(0.39)(12)+3.01(.55)(0.39)+4.7(12)(0.39)+12(0.45)(2.41)+3.7(
0.39)(12)+12(0.35)(1.81)+
3.7(0.39)(12)+12(0.35)(1.81)+2.7(0.39)(12)+12(0.25)(1.21)+1.7(0.39)(12)+12(0.15)(0.61)
=253.16 cum
4.)@ section D
Vol of Concrete=6.2(0.39)(6)+6(0.60)(3.11)+4.8(0.39)(6)+6(0.50)(2.51)+3.4(0.39)(6)+0.40(6)(0.91)
=54.61 cum
Total Volume concrete=135.702cum+556.53cum+253.16 cum+54.61 cum
=1000.002 cum concrete
No. of Bags Cement=1000.002x 9=9000 bags Cement
No. of cum Sand=1000.002 x .50
=500 cum Sand
No. of Cum Gravel=1000 cum Gravel

III.Reinforcements
For The Stem,exposed face(extended bars)
1.@ Section A

a.)Length of Vertical Bars from station0+000 to sta0+012


=5+.250+.50-0.075+.30
=5.975m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc pe Commercial Length=6/5.975
=1 pc 12 mm x 6m
Use 28 pcs 12 mm x 6 m bars
b.)Length of Vertical Bars from station0+012 to sta0+024
=3.65+.250+.50-0.075+.30
=4.625m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc pe Commercial Length=6/4.625
=1 pc 12 mm x 6m
Use 28 pcs 12 mm x 6 m bars(Wastage is 28 pcs 1.375m Length)
c.)Length of Vertical Bars from station0+024 to sta0+036
=2.7+.250+.50-0.075+.30
=3.675m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars

No of Bar pc pe Commercial Length=7.5/3.675


=2 pcs
No of Pcs 12 mm x 7.5=28/2
Use 14 pcs 12 mm x 7.5 m bars
c.)Length of Vertical Bars from station0+036 to sta0+048
=1.8+.250+.50-0.075+.30
=2.775m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc pe Commercial Length=6/2.775
=2 pcs12 mm x 6m
No of Pcs 12 mm x 6=28/2
Use 14 pcs 12 mm x 6 m bars
2.@ section B
a.) Length of Vertical Bars from station0+00 to sta0+024
=5+.250+.50-0.075+.30
=5.975m
No. of pcs bars=24/.440
=54.54 say 55 pcs bars
No of Bar pc pe Commercial Length=6/5.975
=1 pc 12 mm x 6m
Use55 pcs 12 mm x 6 m bars
b.) Length of Vertical Bars from station0+024 to sta0+048
=4.5+.250+.50-0.075+.30
=5.475m

No. of pcs bars=12/.440


=27.27 say 28 pcs bars
No of Bar pc per Commercial Length=6/5.475
=1pcs12 mm x 6m
Use 28 pcs 12 mm x 6 m bars
c.) Length of Vertical Bars from station0+048 to sta0+072
=4+.250+.50-0.075+.30
=4.975m
No. of pcs bars=24/.440
=54.54 say 55 pcs bars
No of Bar pc pe Commercial Length=10.5/5.975
=2 pc 12 mm x 10.5m
No of Pcs 12 mm x 10.5=55/2
Use28 pcs 12 mm x 10.5 m bars(Wastage is 0.55 m)
d.) Length of Vertical Bars from station0+072 to sta0+084
=3.5+.250+.50-0.075+.30
=4.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=10.5/4.475
=2 pc 12 mm x 10.5m
No of Pcs 12 mm x 10.5=28/2
Use14 pcs 12 mm x 10.5 m bars(Wastage is 14 pcs 1.55 m)
e.) Length of Vertical Bars from station0+084to sta0+096
=3+.250+.50-0.075+.30

=3.975m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=9/3.975
=2 pc 12 mm x 9m
No of Pcs 12 mm x 9=28/2
Use14 pcs 12 mm x 9 m bars(Wastage is 1.05 m)
f.) Length of Vertical Bars from station0+096to sta0+108
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=7.5/3.475
=2 pc 12 mm x 7.5m
No of Pcs 12 mm x 7.5=28/2
Use14 pcs 12 mm x 9 m bars(wastage is 0.55)
G.) Length of Vertical Bars from station0+108to sta0+120
=2+.250+.50-0.075+.30
=2.975m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/2.975
=2 pc 12 mm x 6m
No of Pcs 12 mm x 6=28/2
Use14 pcs 12 mm x 6 m bars

h.) Length of Vertical Bars from station0+120to sta0+132


=1.5+.250+.50-0.075+.30
=2.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=7.5/2.475
=3 pc 12 mm x 6m
No of Pcs 12 mm x 6=28/3
Use10 pcs 12 mm x 7.5 m bars
i.) Length of Vertical Bars from station0+132to sta0+144
=1+.250+.50-0.075+.30
=1.975m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/1.975
=3 pc 12 mm x 6m
No of Pcs 12 mm x 6=28/3
Use10 pcs 12 mm x 6 m bars

j.) Length of Vertical Bars from station0+144to sta0+156


=0.5+.250+.50-0.075+.30
=1.475m
No. of pcs bars=12/.440
=28 pcs bars
Use the wastage from sta0+072 to sta0+084

Add 2 pcs 12 mm x 6 m bars


For the remaining stations,add 4 pcs 12 mm x 6 m bars

3.)@ Section C,
a.) Length of Vertical Bars from station0+000to sta0+027
=5+.250+.50-0.075+.30
=5.975m
No. of pcs bars=27/.440
=61.36 say 62 pcs bars
No of Bar pc pe Commercial Length=6/5.975
=1pc 12 mm x 6m
Use61 pcs 12 mm x 6 m bars

b.) Length of Vertical Bars from station0+027to sta0+039


=4.5+.250+.50-0.075+.30
=5.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/5.475
=1pc 12 mm x 6m
Use28 pcs 12 mm x 6 m bars
c.) Length of Vertical Bars from station0+039to sta0+051
=3.5+.250+.50-0.075+.30
=4.475m
No. of pcs bars=12/.440

=28 pcs bars


No of Bar pc pe Commercial Length=9/4.475
=2pc 12 mm x 6m
No of Pcs 12 mm x 9=28/2
Use14 pcs 12 mm x 9 m bars
D.) Length of Vertical Bars from station0+051to sta0+063
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=10.5/3.475
=3pc 12 mm x 6m
No of Pcs 12 mm x 10.5=28/3
Use10 pcs 12 mm x 10.5 m bars
E.) Length of Vertical Bars from station0+063to sta0+075
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=10.5/3.475
=3pc 12 mm x 6m
No of Pcs 12 mm x 10.5=28/3
Use10 pcs 12 mm x 10.5 m bars
F.) Length of Vertical Bars from station0+075to sta0+087
=1.5+.250+.50-0.075+.30

=2.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=7.5/2475
=3pc 12 mm x 7.5m
No of Pcs 12 mm x 7.5=28/3
Use10 pcs 12 mm x 7.5 m bars
G.) Length of Vertical Bars from station0+087to sta0+099
=0.5+.250+.50-0.075+.30
=1.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/1.475
=4pc 12 mm x 7.5m
No of Pcs 12 mm x 6=28/4
Use7 pcs 12 mm x 6 m bars

4.)@ Section d,
a.) Length of Vertical Bars from station0+000to sta0+006
=5+.250+.50-0.075+.30
=5.975m
No. of pcs bars=6/.440
=14 pcs bars
No of Bar pc pe Commercial Length=6/5.975
=1pc 12 mm x 6m

Use14 pcs 12 mm x 6 m bars


B.) Length of Vertical Bars from station0+006to sta0+012
=3.6+.250+.50-0.075+.30
=4.575m

c.) Length of Vertical Bars from station0+012to sta0+018


=2.2+.250+.50-0.075+.30
=3.175m

Total Length=4.575+3.175
=7.75m
No. of pcs bars=6/.440
=1 4 pcs bars
Use 14 pcs 12 mm x 9 mm bars(Wastage is 1.25m)

For The Stem,exposed face(Flex Bars)


1.@ Section A

a.)Length of Vertical Bars from station0+000 to sta0+012


=1.87+.250+.50-0.075
=2.47m
No. of pcs bars=12/.440

=27.27 say 28 pcs bars


No of Bar pc pe Commercial Length=7.5/2.47
No of 12mmx7.5 bars=28/3
=10 pcs 12mmx7.5m bars

b.)Length of Vertical Bars from station0+012 to sta0+024


=0.53+.250+.50
=1.28m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc pe Commercial Length=9/1.28
=8pc 12 mm x 9m
No of 12mmx 9 m bars=28/9
Use 4 pcs 12 mm x 9 m bars
c.)Length of Vertical Bars from station0+024 to sta0+036
=2.7+.250+.50-0.075+.30
=3.675m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc pe Commercial Length=7.5/3.675
=2 pcs12 mm x 7.5m
No of Pcs 12 mm x 7.5=28/2
Use 14 pcs 12 mm x 7.5 m bars
c.)Length of Vertical Bars from station0+036 to sta0+048
=1.8+.250+.50-0.075+.30

=2.775m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc pe Commercial Length=6/2.775
=2 pcs12 mm x 6m
No of Pcs 12 mm x 6=28/2
Use 14 pcs 12 mm x 6 m bars
2.@ section B
a.) Length of Vertical Bars from station0+00 to sta0+024
=1.88+.250+.50-0.075+.30
=2.86m
No. of pcs bars=24/.440
=54.54 say 55 pcs bars
No of Bar pc pe Commercial Length=6/2.86
=2 pc s
No of Pcs 12 mm x 6=55/2
Use28 pcs 12 mm x 6 m bars
b.) Length of Vertical Bars from station0+024 to sta0+048
=1.38+.250+.50-0.075+.30
=2.36m
No. of pcs bars=12/.440
=27.27 say 28 pcs bars
No of Bar pc per Commercial Length=7.5/2.36
=3pcs
No of Pcs 12 mm x 7.5=28/3

Use 10 pcs 12 mm x 6 m bars


c.) Length of Vertical Bars from station0+048 to sta0+072
=0.88+.250+.50-0.075+.30
=1.86 m
No. of pcs bars=24/.440
=54.54 say 55 pcs bars
No of Bar pc pe Commercial Length=7.5/1.86
=4pc s
No of Pcs 12 mm x 7.5=55/4
Use14 pcs 12 mm x 7.5 m bars
d.) Length of Vertical Bars from station0+072 to sta0+084
=0.38+.250+.50-0.075+.30
=1.36m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc per Commercial Length=6/1.36
=4 pcs
No of Pcs 12 mm x 6=28/4
Use7pcs 12 mm x 6 m bars
e.) Length of Vertical Bars from station0+084to sta0+096
=3+.250+.50-0.075+.30
=3.975m
No. of pcs bars=12/.440
=28 pcs bars

No of Bar pc pe Commercial Length=9/3.975


=2 pc 12 mm x 9m
No of Pcs 12 mm x 9=28/2
Use14 pcs 12 mm x 9 m bars(Wastage is 1.05 m)
f.) Length of Vertical Bars from station0+096to sta0+108
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=7.5/3.475
=2 pc 12 mm x 7.5m
No of Pcs 12 mm x 7.5=28/2
Use14 pcs 12 mm x 9 m bars(wastage is 0.55)
G.) Length of Vertical Bars from station0+108to sta0+120
=2+.250+.50-0.075+.30
=2.975m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/2.975
=2 pc 12 mm x 6m
No of Pcs 12 mm x 6=28/2
Use14 pcs 12 mm x 6 m bars
h.) Length of Vertical Bars from station0+120to sta0+132
=1.5+.250+.50-0.075+.30
=2.475m

No. of pcs bars=12/.440


=28 pcs bars
No of Bar pc pe Commercial Length=7.5/2.475
=3 pc 12 mm x 6m
No of Pcs 12 mm x 6=28/3
Use10 pcs 12 mm x 7.5 m bars
i.) Length of Vertical Bars from station0+132to sta0+144
=1+.250+.50-0.075+.30
=1.975m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/1.975
=3 pc 12 mm x 6m
No of Pcs 12 mm x 6=28/3
Use10 pcs 12 mm x 6 m bars

j.) Length of Vertical Bars from station0+144to sta0+156


=0.5+.250+.50-0.075+.30
=1.475m
No. of pcs bars=12/.440
=28 pcs bars
Use the wastage from sta0+072 to sta0+084
Add 2 pcs 12 mm x 6 m bars
For the remaining stations,add 4 pcs 12 mm x 6 m bars

3.)@ Section C,
a.) Length of Vertical Bars from station0+000to sta0+027
=1.88+.250+.50-0.075+.30
=2.86m
No. of pcs bars=27/.440
=61.36 say 62 pcs bars
No of Bar pc pe Commercial Length=6/2.86
=2pcs
No of Pcs 12 mm x 6=61/2

Use31 pcs 12 mm x 6 m bars

b.) Length of Vertical Bars from station0+027to sta0+039


=1.38+.250+.50-0.075+.30
=2.36m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=7.5/2.36
=3pcs
No of Pcs 12 mm x 7.5=28/3

Use10 pcs 12 mm x 7.5m bars


c.) Length of Vertical Bars from station0+039to sta0+051
=0.38+.250+.50-0.075+.30
=1.36m

No. of pcs bars=12/.440


=28 pcs bars
No of Bar pc pe Commercial Length=6/1.36
=4pcs
No of Pcs 12 mm x 6=28/4
Use7 pcs 12 mm x 6 m bars
D.) Length of Vertical Bars from station0+051to sta0+063
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=10.5/3.475
=3pc 12 mm x 6m
No of Pcs 12 mm x 10.5=28/3
Use10 pcs 12 mm x 10.5 m bars
E.) Length of Vertical Bars from station0+063to sta0+075
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=10.5/3.475
=3pc 12 mm x 6m
No of Pcs 12 mm x 10.5=28/3
Use10 pcs 12 mm x 10.5 m bars
F.) Length of Vertical Bars from station0+075to sta0+087

=1.5+.250+.50-0.075+.30
=2.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=7.5/2475
=3pc 12 mm x 7.5m
No of Pcs 12 mm x 7.5=28/3
Use10 pcs 12 mm x 7.5 m bars
G.) Length of Vertical Bars from station0+087to sta0+099
=0.5+.250+.50-0.075+.30
=1.475m
No. of pcs bars=12/.440
=28 pcs bars
No of Bar pc pe Commercial Length=6/1.475
=4pc 12 mm x 7.5m
No of Pcs 12 mm x 6=28/4
Use7 pcs 12 mm x 6 m bars

4.)@ Section d,
a.) Length of Vertical Bars from station0+000to sta0+006
=1.88+.250+.50-0.075+.30
=2.86m
No. of pcs bars=6/.440
=14 pcs bars
No of Bar pc pe Commercial Length=6/2.86

=2 pc
No of Pcs 12 mm x 6=14/2
Use7 pcs 12 mm x 6 m bars
B.) Length of Vertical Bars from station0+006to sta0+012
=0.48+.250+.50-0.075+.30
=1.46m
No. of pcs bars=6/.440
=14 pcs
No of 12mmx 6=14/4
Use 4 pcs 12 mm x 9 mm bars

c.) Length of Vertical Bars from station0+012to sta0+018


=2.2+.250+.50-0.075+.30
=3.175m
Use 4 pcs 12 mm x 7.5 mm bars

For stem,horizontal bars


Splice length=0.50m
1.)@ section A
a.)from sta0+000 to sta0+012
Length per bar=12m
No of pcs bars needed=5.25/.225
=24 pcs bars

No. of pcs bars=24(12)/7


Use 42 pcs 12mmx 7.5 bars
b.)from sta0+012 to sta0+024
Length per bar=12m
No of pcs bars needed=3.9/.225
=18 pcs bars
No. of pcs bars=18(12)/7
Use 31 pcs 12mmx 7.5 bars
c.)from sta0+024 to sta0+036
Length per bar=12m
No of pcs bars needed=2.95/.225
=14 pcs bars
No. of pcs bars=14(12)/7
Use 24 pcs 12mmx 7.5 bars
d.)from sta0+036to sta0+048
Length per bar=12m
No of pcs bars needed=2.05/.225
=10 pcs bars
No. of pcs bars=10(12)/7
Use 18 pcs 12mmx 7.5 bars
2.)@ section B
a.)from sta0+000 to sta0+024
Length per bar=24m
No of pcs bars needed=5.25/.225

=24 pcs bars


No. of pcs bars=24(24)/7
Use 83 pcs 12mmx 7.5 bars
b.)from sta0+024to sta0+048
Length per bar=12m
No of pcs bars needed=4.75/.225
=22 pcs bars
No. of pcs bars=22(12)/7
Use 38 pcs 12mmx 7.5 bars
c.)from sta0+024to sta0+048
Length per bar=12m
No of pcs bars needed=4.75/.225
=22 pcs bars
No. of pcs bars=22(12)/7
Use 38 pcs 12mmx7.5 bars
d.) from sta0+048to sta0+072
Length per bar=12m
No of pcs bars needed=4.25/.225
=19 pcs bars
No. of pcs bars=19(12)/7
Use 33 pcs 12mmx7.5 bars
e.) from sta0+072to sta0+084
Length per bar=12m
No of pcs bars needed=3.25/.225

=15 pcs bars


No. of pcs bars=15 (12)/7
Use 26 pcs 12mmx7.5 bars
f.) from sta0+096to sta0+108
Length per bar=12m
No of pcs bars needed=2.75/.225
=13 pcs bars
No. of pcs bars=13 (12)/7
Use 23pcs 12mmx7.5 bars
g.) from sta0+108to sta0+120
Length per bar=12m
No of pcs bars needed=2.25/.225
=10 pcs bars
No. of pcs bars=10(12)/7
Use 18pcs 12mmx7.5 bars
h.) from sta0+120to sta0+132
Length per bar=12m
No of pcs bars needed=1.75/.225
=6pcs bars
No. of pcs bars=6(12)/7
Use 11pcs 12mmx7.5 bars
i.) from sta0+132to sta0+144
Length per bar=12m
No of pcs bars needed=1.25/.225

=6pcs bars
No. of pcs bars=6(12)/7
Use 11pcs 12mmx7.5 bars
j.) from sta0+144to sta0+156
Length per bar=12m
No of pcs bars needed=.75/.225
=4pcs bars
No. of pcs bars=4(12)/7
Use 7pcs 12mmx7.5 bars
k.) from sta0+156to sta0+156
Length per bar=12m
No of pcs bars needed=.25/.225
=2pcs bars
No. of pcs bars=2 (12)/7
Use 4pcs 12mmx7.5 bars

Add 2 pcs 12mmx 7.5 for the remaining stations


3.)@ section C
a.)from sta0+000 to sta0+027
Length per bar=27m
No of pcs bars needed=5.25/.225
=24 pcs bars
No. of pcs bars=27(24)/7
Use 93 pcs 12mmx 7.5 bars

b.)from sta0+027to sta0+039


Length per bar=12m
No of pcs bars needed=4.75/.225
=22 pcs bars
No. of pcs bars=22(12)/7
Use 38 pcs 12mmx 7.5 bars
c.)from sta0+039to sta0+051
Length per bar=12m
No of pcs bars needed=3.75/.225
=17 pcs bars
No. of pcs bars=17(12)/7
Use 30 pcs 12mmx 7.5 bars
d.) from sta0+051to sta0+063
Length per bar=12m
No of pcs bars needed=2.75/.225
=13 pcs bars
No. of pcs bars=13(12)/7
Use 23 pcs 12mmx 7.5 bars
e.) from sta0+063to sta0+075
Length per bar=12m
No of pcs bars needed=2.75/.225
=13 pcs bars
No. of pcs bars=13(12)/7
Use 23 pcs 12mmx 7.5 bars

f.) from sta0+075to sta0+087


Length per bar=12m
No of pcs bars needed=1.75/.225
=8 pcs bars
No. of pcs bars=8 (12)/7
Use 14 pcs 12mmx 7.5 bars
g.) from sta0+087to sta0+099
Length per bar=12m
No of pcs bars needed=0.75/.225
=4 pcs bars
No. of pcs bars=4 (12)/7
Use 7pcs 12mmx 7.5 bars
4.)@ section D
a.)from sta0+000 to sta0+006
Length per bar=6m
No of pcs bars needed=5.25/.225
=24 pcs bars
No. of pcs bars=6(24)/7
Use 21 pcs 12mmx 7.5 bars
b.)from sta0+006to sta0+012
Length per bar=6m
No of pcs bars needed=3.85/.225
=18 pcs bars
No. of pcs bars=18(6)/7

Use 16 pcs 12mmx 7.5 bars


b.)from sta0+012to sta0+018
Length per bar=6m
No of pcs bars needed=1.45/.225
=7pcs bars
No. of pcs bars=7(6)/7
Use 6 pcs 12mmx 7.5 bars

For The Stem,rear face(Flex Bars,16 mm and extension bars,12 mm)


1.@ Section A

a.)Length of Vertical Bars from station0+000 to sta0+012


=1.88+.250+.50+.40
=3 m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=6/3
=2 pc
Use 47 pcs 16 mm x 6 m bars
b.)Length of Vertical Bars from station0+012 to sta0+024
=0.53+.250+.50+.40
=2m
No. of pcs bars=12/.130
=93 pcs bars

No of Bar pc pe Commercial Length=6/2


=3 pc 12 mm x 6m
Use 31 pcs 16 mm x 6 m bars
Use 24 pcs 12 mm x 6 m bars

c.)Length of Vertical Bars from station0+024 to sta0+036


=2.7+.250+.50-0.075+.30
=3.675m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=6/3
=2 pcs12 mm x 6m
Use 47pcs 16 mm x 6 m bars
Use 12 pcs 12 mm x 6 m bars
d.)Length of Vertical Bars from station0+036 to sta0+048
=1.8+.250+.50-0.075+.30
=2.775m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=6/2.775
=2 pcs16 mm x 6m
Use 47pcs 16mm x 6 m bars
2.@ section B
a.) Length of Vertical Bars from station0+00 to sta0+024
=1.88+.250+.50+.40

=3m
No. of pcs bars=24/.130
=185 pcs bars
No of Bar pc pe Commercial Length=6/3
=2 pc
Use93 pcs 16 mm x 6 m bars
Use also 47 pcs 12mm x 6m bars
b.) Length of Vertical Bars from station0+024 to sta0+048
=1.38+.250+.50+.40
=2.5m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc per Commercial Length=7.5/2.5
=3pcs16 mm x 6m
Use 31pcs 16 mm x 6 m bars
Use also 24 pcs 12 mm x 6 m bars
c.) Length of Vertical Bars from station0+048 to sta0+072
=0.88+.250+.50+.40
=2.5m
No. of pcs bars=24/.130
=185 pcs bars
No of Bar pc pe Commercial Length=7.5/3
=3 pc
Use62 pcs 16 mm x 7.5 m bars
Use 47 pcs 12 mm x 6 m

d.) Length of Vertical Bars from station0+072 to sta0+084


=3.5+.250+.50+.30
=5.05m
No. of pcs bars=12/.130
=93pcs bars
No of Bar pc pe Commercial Length=10.5/5.05
=2 pc 12 mm x 10.5m
Use47 pcs 16mm x 10.5 m bars
e.) Length of Vertical Bars from station0+084to sta0+096
=3+.250+.50-0.075+.30
=3.975m
No. of pcs bars=12/.130
=93pcs bars

Use48 pcs 16 mm x 6 m bars


Use also 16 pcs 12 mm x 6m bars
f.) Length of Vertical Bars from station0+096to sta0+108
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=7.5/3.475
=2 pc
Use48 pcs 16 mm x 7.5 m bars
G.) Length of Vertical Bars from station0+108to sta0+120

=2+.250+.50-0.075+.30
=2.975m
No. of pcs bars=12/.130
=93 pcs bars

Use48 pcs 16 mm x 6 m bars


h.) Length of Vertical Bars from station0+120to sta0+132
=1.5+.250+.50-0.075+.30
=2.475m
No. of pcs bars=12/.130
Use32 pcs 16 mm x 7.5 m bars
i.) Length of Vertical Bars from station0+132to sta0+144
=1+.250+.50-0.075+.30
=1.975m
No. of pcs bars=12/.130
=93pcs bars

Use32 pcs 16 mm x 6 m bars

j.) Length of Vertical Bars from station0+144to sta0+156


=0.5+.250+.50-0.075+.30
=1.475m
No. of pcs bars=12/.130
=93pcs bars
Use 24 pcs 16mm x 6 m bars

3.)@ Section C,
a.) Length of Vertical Bars from station0+000to sta0+027
=1.88+.250+.50+.40
=3m
No. of pcs bars=27/.130
=208 pcs bars
No of Bar pc pe Commercial Length=6/3
=2 pcs
Use104pcs 16 mm x 6 m bars
Use also 52 pcs 12 mm x 6 m bars

b.) Length of Vertical Bars from station0+027to sta0+039


=1.38+.250+.50+.40
=2.5m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=7.5/2.5
=3pc
Use32 pcs 16 mm x 7.5 m bars
Use also 24 pcs 12 mm x 6 m bars
c.) Length of Vertical Bars from station0+039to sta0+051
=3.5+.250+.50-0.075+.40
=4.475m
No. of pcs bars=12/.130

=93 pcs bars


No of Bar pc pe Commercial Length=6/3
=2pcs
Use48 pcs 16mm x 6 m bars
Use also 12pcs 12 mm x 6 m bars
D.) Length of Vertical Bars from station0+051to sta0+063
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=7.5/3.475
=3pc

Use48 pcs 16 mm x 7.5 m bars


E.) Length of Vertical Bars from station0+063to sta0+075
=2.5+.250+.50-0.075+.30
=3.475m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=7.5/3.475
=3pc
Use48 pcs 16 mm x 7.5 m bars
F.) Length of Vertical Bars from station0+075to sta0+087
=1.5+.250+.50-0.075+.30
=2.475m

No. of pcs bars=12/..130


=93pcs bars
No of Bar pc pe Commercial Length=7.5/2475
=3pc 12 mm x 7.5m

Use32 pcs 16 mm x 7.5 m bars


G.) Length of Vertical Bars from station0+087to sta0+099
=0.5+.250+.50-0.075+.30
=1.475m
No. of pcs bars=12/.130
=93 pcs bars
No of Bar pc pe Commercial Length=6/1.475
=4pc

Use24 pcs 16 mm x 6 m bars

4.)@ Section d,
a.) Length of Vertical Bars from station0+000to sta0+006
=1.88+.250+.50-0.075+.30
=3m
No. of pcs bars=6/.130
=47 pcs bars
No of Bar pc pe Commercial Length=6/3
=2pc 12 mm x 6m
Use24 pcs 16 mm x 6 m bars

Use also 12 pcs 12 mm x 6m


B.) Length of Vertical Bars from station0+006to sta0+012 &
=3.6+.250+.50-0.075+.30
=4.575m

c.) Length of Vertical Bars from station0+012to sta0+018


=2.2+.250+.50-0.075+.30
=3.175m

Use 47 pcs 16 mm x 9 m bars

FOR THE BASE


A.)for 16 mm
1.)@ section A
a.)at station 0+000 to sta 0+012
Length of bar =3.5-2(0.075)+2(9)(.012)+.50
=4.066m
No of pcs bar per commercial length=9/4.5
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 9m bars

b.)at station 0+012 to sta 0+024


Length of bar =2.9-2(0.075)+2(9)(.016)+.50
=3.54m
No of pcs bar per commercial length=10.5/3.5
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 7.5m bars
c.)at station 0+024 to sta 0+036
Length of bar =2.3-2(0.075)+2(9)(.016)+.50
=2.94m
No of pcs bar per commercial length=6/2.94
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 6m bars
d.)at station 0+036 to sta 0+048
Length of bar =1.8-2(0.075)+2(9)(.016)+.50
=2.44m
No of pcs bar per commercial length=7.5/2.44
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 7.5m bars

2.)@ section B
a.)at station 0+000 to sta 0+024
Length of bar =3.5-2(0.075)+2(9)(.016)+.50
=4.066m
No of pcs bar per commercial length=9/4.5
=2 pcs
No of pcs bars=24/.150
=160 pcs
Use 80 pcs 16 mm x 9m bars
b.) at station 0+024to sta 0+048
Length of bar =3.4-2(0.075)+2(9)(.016)+.50
=4.066m
No of pcs bar per commercial length=9/4
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 9m bars
c.) at station 0+048to sta 0+072
Length of bar =3.10-2(0.075)+2(9)(.016)+.50
=3.75
No of pcs bar per commercial length=7.5/3.75
=2 pcs
No of pcs bars=12/.150
=80 pcs

Use 40 pcs 16 mm x 7.5m bars


d.) at station 0+072to sta 0+084
Length of bar =2.8-2(0.075)+2(9)(.016)+.50
=3.5m
No of pcs bar per commercial length=10.5/3.5
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 10.5m bars
e.) at station 0+084to sta 0+096
Length of bar =2.5-2(0.075)+2(9)(.016)+.50
=3.2m
No of pcs bar per commercial length=10.5/3.5
=3 pcs
No of pcs bars=12/.150
=80 pcs
f.) at station 0+096to sta 0+108
Length of bar =2.2-2(0.075)+2(9)(.016)+.50
=3 m
No of pcs bar per commercial length=6/3
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 6 m bars

g.) at station 0+108to sta 0+120


Length of bar =1.9-2(0.075)+2(9)(.016)+.50
=2.7m
No of pcs bar per commercial length=6/3
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 6 m bars
h.) at station 0+120 to sta 0+132
Length of bar =1.6-2(0.075)+2(9)(.016)+.50
=2.5m
No of pcs bar per commercial length=7.5/2.5
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 7.5 m bars
i.) at station 0+132 to sta 0+144
Length of bar =1.3-2(0.075)+2(9)(.016)+.50
=2.2m
No of pcs bar per commercial length=7.5/2.2
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 7.5 m bars

j.) at station 0+144 to sta 0+156


Length of bar =1-2(0.075)+2(9)(.016)+.50
=1.9 m
No of pcs bar per commercial length=6/1.9
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 6 m bars
j.) at station 0+156 to sta 0+168
Length of bar =0.70-2(0.075)+2(9)(.016)+.50
=1.6 m
No of pcs bar per commercial length=6/1.6
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 6 m bars
k.) at station 0+168 to sta 0+180
Length of bar =0.40-2(0.075)+2(9)(.016)+.50
=1.3 m
No of pcs bar per commercial length=6/1.5
=4 pcs
No of pcs bars=12/.150
=80 pcs
Use 20pcs 16 mm x 6 m bars

3.)@ section C
a.)at station 0+000 to sta 0+027
Length of bar =3.5-2(0.075)+2(9)(.016)+.50
=4.066m
No of pcs bar per commercial length=9/4.5
=2 pcs
No of pcs bars=27/.150
=180 pcs
Use 90 pcs 16 mm x 9m bars
b.) at station 0+027to sta 0+039
Length of bar =3.4-2(0.075)+2(9)(.016)+.50
=4.066m
No of pcs bar per commercial length=9/4
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 9m bars

c.) at station 0+039to sta 0+051


Length of bar =2.8-2(0.075)+2(9)(.016)+.50
=3.5m
No of pcs bar per commercial length=10.5/3.5
=3 pcs
No of pcs bars=12/.150

=80 pcs
Use 27 pcs 16 mm x 10.5m bars
d.) at station 0+051to sta 0+063
Length of bar =2.2-2(0.075)+2(9)(.016)+.50
=2.8m
No of pcs bar per commercial length=6/2.8
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 6m bars
e.) at station 0+063to sta 0+075
Length of bar =2.2-2(0.075)+2(9)(.016)+.50
=2.8m
No of pcs bar per commercial length=6/2.8
=2 pcs
No of pcs bars=12/.150
=80 pcs
Use 40 pcs 16 mm x 6m bars

e.) at station 0+075 to sta 0+087


Length of bar =1.6-2(0.075)+2(9)(.016)+.50
=2.2m
No of pcs bar per commercial length=7.5/2.2
=3 pcs

No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 7.5m bars
e.) at station 0+087 to sta 0+099
Length of bar =1-2(0.075)+2(9)(.016)+.50
=1.6m
No of pcs bar per commercial length=6/1.6
=3 pcs
No of pcs bars=12/.150
=80 pcs
Use 27 pcs 16 mm x 6m bars

4.)@ section D
a.)at station 0+000 to sta 0+006
Length of bar =3.5-2(0.075)+2(9)(.016)+.50
=4.066m
No of pcs bar per commercial length=9/4.5
=2 pcs
No of pcs bars=6/.150
=40 pcs
Use 20 pcs 16 mm x 9m bars

b.)at station 0+006 to sta 0+012


Length of bar =2.9-2(0.075)+2(9)(.016)+.50

=3.5 m
No of pcs bar per commercial length=10.5/3.5
=3 pcs
No of pcs bars=6/.150
=40 pcs
Use 14 pcs 16 mm x 7.5m bars
b.)at station 0+012 to sta 0+018
Length of bar =1.3-2(0.075)+2(9)(.016)+.50
=1.94 m
No of pcs bar per commercial length=7.5/2.5
=3 pcs
No of pcs bars=6/.150
=40 pcs
Use 14 pcs 16 mm x 7.5m bars

FOR 12 MM BARS
1.)@ section A
a.)from sta0+000 to sta0+012
Length per bar=12m
No of pcs bars needed=3.35/.110
=31pcs bars
No. of pcs bars=31(12)/7
Use 54 pcs 12mmx 7.5 bars

b.)from sta0+012 to sta0+024


Length per bar=12m
No of pcs bars needed=2.75/.110
=25pcs bars
No. of pcs bars=25(12)/7
Use 43 pcs 12mmx 7.5 bars
c.)from sta0+024 to sta0+036
Length per bar=12m
No of pcs bars needed=2.15/.110
=20pcs bars
No. of pcs bars=20(12)/7
Use 35 pcs 12mmx 7.5 bars
d.)from sta0+036 to sta0+048
Length per bar=12m
No of pcs bars needed=1.65/.110
=15pcs bars
No. of pcs bars=15(12)/7
Use 26 pcs 12mmx 7.5 bars

2.)@ section B
a.)from sta0+000 to sta0+024
Length per bar=24m
No of pcs bars needed=3.35/.110
=31pcs bars

No. of pcs bars=31(24)/7


Use 107 pcs 12mmx 7.5 bars
b.) from sta0+024 to sta0+048
Length per bar=12m
No of pcs bars needed=3.25/.110
=30pcs bars
No. of pcs bars=30(12)/7
Use 52pcs 12mmx 7.5 bars
c.) from sta0+048 to sta0+072
Length per bar=24m
No of pcs bars needed=2.95/.110
=27pcs bars
No. of pcs bars=27 (24)/7
Use 104pcs 12mmx 7.5 bars
D.) from sta0+072 to sta0+084
Length per bar=12m
No of pcs bars needed=2.65/.110
=25pcs bars
No. of pcs bars=25 (12)/7
Use 42pcs 12mmx 7.5 bars
E.) from sta0+084 to sta0+096
Length per bar=12m
No of pcs bars needed=2.35/.110
=22pcs bars

No. of pcs bars=22 (12)/7


Use 38pcs 12mmx 7.5 bars
F.) from sta0+096 to sta0+108
Length per bar=12m
No of pcs bars needed=2.05/.110
=19pcs bars
No. of pcs bars=19 (12)/7
Use 33pcs 12mmx 7.5 bars
G.) from sta0+108 to sta0+120
Length per bar=12m
No of pcs bars needed=1.75/.110
=16pcs bars
No. of pcs bars=16 (12)/7
Use 28pcs 12mmx 7.5 bars
H.) from sta0+120 to sta0+132
Length per bar=12m
No of pcs bars needed=1.75/.110
=16pcs bars
No. of pcs bars=16 (12)/7
Use 28pcs 12mmx 7.5 bars
I.) from sta0+132 to sta0+144
Length per bar=12m
No of pcs bars needed=1.15/.110
=11pcs bars

No. of pcs bars=11 (12)/7


Use 19pcs 12mmx 7.5 bars
J.) from sta0+144to sta0+156
Length per bar=12m
No of pcs bars needed=.85/.110
=8pcs bars
No. of pcs bars=8 (12)/7
Use 14pcs 12mmx 7.5 bars
K.) from sta0+156to sta0+168
Length per bar=12m
No of pcs bars needed=.55/.110
=5pcs bars
No. of pcs bars=5 (12)/7
Use 9pcs 12mmx 7.5 bars
L.) from sta0+168to sta0+180
Length per bar=12m
No of pcs bars needed=.25/.110
=3pcs bars
No. of pcs bars=3 (12)/7
Use 6pcs 12mmx 7.5 bars

3.)@ section C
a.)from sta0+000 to sta0+027

Length per bar=27m


No of pcs bars needed=3.35/.110
=31pcs bars
No. of pcs bars=31(27)/7
Use 120 pcs 12mmx 7.5 bars
b.)from sta0+027to sta0+039
Length per bar=12m
No of pcs bars needed=3.255/.110
=30pcs bars
No. of pcs bars=30(12)/7
Use 52 pcs 12mmx 7.5 bars
c.)from sta0+039to sta0+051
Length per bar=12m
No of pcs bars needed=2.65/.110
=26pcs bars
No. of pcs bars=26(12)/7
Use 45 pcs 12mmx 7.5 bars
d.)from sta0+051to sta0+063
Length per bar=12m
No of pcs bars needed=2.05/.110
=19pcs bars
No. of pcs bars=19(12)/7
Use 33 pcs 12mmx 7.5 bars
e.)from sta0+063to sta0+075

Length per bar=12m


No of pcs bars needed=2.05/.110
=19pcs bars
No. of pcs bars=19(12)/7
Use 33 pcs 12mmx 7.5 bars
f.)from sta0+075to sta0+087
Length per bar=12m
No of pcs bars needed=1.45/.110
=14pcs bars
No. of pcs bars=14(12)/7
Use 24 pcs 12mmx 7.5 bars
f.)from sta0+087to sta0+099
Length per bar=12m
No of pcs bars needed=.85/.110
=8pcs bars
No. of pcs bars=8(12)/7
Use 14 pcs 12mmx 7.5 bars

4.)@ section D
a.)from sta0+000 to sta0+006
Length per bar=6m
No of pcs bars needed=3.35/.110
=31pcs bars
No. of pcs bars=31(6)/7

Use 27pcs 12mmx 7.5 bars


b.)from sta0+006 to sta0+012
Length per bar=6m
No of pcs bars needed=2.75/.110
=25pcs bars
No. of pcs bars=25(6)/7
Use 22pcs 12mmx 7.5 bars
c.) from sta0+012 to sta0+018
Length per bar=6m
No of pcs bars needed=1.15/.110
=11pcs bars
No. of pcs bars=11 (6)/7
Use 10pcs 12mmx 7.5 bars
IV.WEEPHOLES
Total linear length=48+180+99+18
=345lm
Length of weep hole PVC=.400m
No of pc Weep holes=345pcs
No. of pcs per commercial length=3/.400
=7.5 say 7 pcs
Total no of 3 diam pvc=345/7
=49.29 say 50 pcs 3 PVC pipes
Volume of gravel filter=.20(.20)(345)
=14 cum gravel filter

FOR FENCING
Total area=1.3(345)
=448.5 sqm
No of CHB=448.5*12.5
=5606.25 say 5620 pcs for breakage

Total Volume of Mortar=3(5620)(0.003)


=50.58 say 51 cum
No of bags=51x9=459 bags PC cement
No of cum sand=26 cum sand
No of cum Gravel=51 cum gravel

For plaster
No of cement=448.5(0.11)
=50 bags P.Cx 2 ==100 bags
NO of cum sand=0.006 x 448.5
=2.69 say 3x2==6 cum
For reinforcements;
Total length=345
Spacing=0.6 m
Total no of Bars=345/0.6
=575 pcs
No of pcs per commercial length=6/1.3
=4 pcs

No of 12 mm x 6 m bars=575/4
=144 pcs 12 mm x 6 bars(Vertical Bars)

For Horizontal Bars


Total area=448.5 sqm
Total Length=448.5x2.7(Spaced every 2 layers)
=1210.95 m
Total no of pcs 10 mm x 6 m bars
=1210.95/6
=201.83 say 202 pcs bars