PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
INPUT DATA & DESIGN SUMMARY
OVERALL LENGTH L = 26 m
85.3 ft
SMALL END DIAMETER D
S
= 280 mm
11.02 in
WEB THICKNESS T
S
= 70 mm
2.76 in
LARGE END DIAMETER D
L
= 746 mm
29.37 in
WEB THICKNESS T
L
= 89 mm
3.50 in
C = 3.05 m = 10.01 ft
D = 691.3 mm = 27.2 in
T = 86.8 mm = 3.4 in A = 164803.8 mm
2
= 255.4 in
2
I = 7684515739 mm
4
= 18462.1 in
4
S = 22230959 mm
3
= 1356.6 in
3
THE DESIGN IS ADEQUATE.
SHIPPING & ERECTION LOADS AT CRITICAL CROSS SECTION (ASD level)
P = -70.36 kN, axial tension
-15.83 kips, axial tension Total Weight : 7179 kg
V = 35.18 kN, shear M = 457.45 kN M, bending 15.83 kips
7.92 kips, shear 337.60 ft-kips, bending
FACTORED ULTIMATE LOADS AT CRITICAL CROSS SECTION (SD level)
P
u
= 44 kN, axial M
u
= 550 kN M, bending
9.90 kips, axial 405.90 ft-kips, bending
V
u
= 53 kN, shear T
u
= 204 kN M, torsion
11.93 kips, shear 150.55 ft-kips, torsion
CONCRETE STRENGTH f '
c
= 62
N / mm
2
=
8.99 ksi
REBAR STRENGTH f
y
* = f
y
= 413
N / mm
2
=
59.89 ksi 0 pre-tensioned
STRAND TENSILE STRENGTH f
su
* = f
pu
= 1862
N / mm
2
=
269.99 ksi
STRAND YIELD STRENGTH f
py
= 1675
N / mm
2
=
242.88 ksi
PRESTRESSING STRAND 16 strands (each 12.7 mm dia. & 98.7 mm
2
area )
(each 0.50 in dia. & 0.153 in
2
area )
STRAND FORCE IMMEDIATELY AFTER PRESTRESS TRANSFER 0.75 f
py
, (ACI 318-11 18.5) P
i
= 1981.7 kN
445.9 kips
STRAND FORCE AT SERVICE LOAD AFTER ALLOWANCE LOSSES 0.6 f
py
, (ACI 318-11 18.6) P
e
= 1585.3 kN
356.7 kips
VERTICAL REINFORCEMENT ( 0 bars for not apply) 4 # 5
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 0 Spirals
LATERAL REINFORCEMENT # 4 @ 305 mm o.c.
12.0 in o.c.
ANALYSIS
CHECK TRANSFER (SHIPPING & ERECTION) LOAD CONDITION (ACI 318 18.4.1, 18.5.1, AASHTO 9.15.1 & 9.15.2.1)
TENSION FIBER STRESS - F
ti
= -0.711 ksi, (AASHTO 9.15.2.1)
COMPRESSION FIBER STRESS F
pi
= 5.394 ksi, (AASHTO 9.15.2.1)
STRAND ALLOWABLE STRESS F
si
= 215.99 ksi, (ACI 318 18.5.1)
f
si
= 182.16 ksi < F
si
[Satisfactory]
-1.303 ksi < - F
ti
[MIN. As' REQUIRED]
4.670 ksi < F
pi
[Satisfactory]
(A
s
')
reqd
= 1.210
in
2
< (A
s
')
provd
(ACI 318-11 R18.4.1) [Satisfactory]
CHECK SERVICEABILITY LOAD CONDITION (ACI 318 18.3.3 & 18.4)
SERVICE LOADS
P =
P
u
/ 1.2 = 8.3 kips, axial
M = M
u
/ 1.4 = 289.9 ft-kips, bending
TENSION FIBER STRESS - F
te
= -1.138 ksi, (Class U or T, ACI 318 18.3.3)
COMPRESSION FIBER STRESS F
pe
= 4.046 ksi, (ACI 318 18.4.2)
STRAND ALLOWABLE STRESS F
se
= 215.99 ksi, (ACI 318 18.5.1)
PRESTRESSING METHOD ( 0, 1 or 2 )
LOCATION OF CRITICAL CROSS SECTION
Prestressed Concrete Circular Hollow Pole/Pile Design Based on ACI 318-11 & AASHTO 17th


i
ti
P M P
f
A A S
= + =
i
pi
P M P
f
A A S
= + + =
(Cont'd)
f
se
= 145.73 ksi < F
se
[Satisfactory]
-1.136 ksi > - F
ti
[Satisfactory]
3.993 ksi < F
pi
[Satisfactory]
CHECK ULTIMATE LOAD CONDITION (AASHTO 9.15.1 & 9.17 ACI 318-11 18.7)
| Pn (k)
| Mn (ft-k)
| M
n
= 617.3 ft-kips @ P
u
= 10 kips > M
u
[Satisfactory]
CHECK SHEAR & TORSIONAL CAPACITY (ACI 318-11 11.3)
| v
n
= | (v
c
) = 142 psi > v
u
[Satisfactory]
where | = 0.75 (ACI 318-11 9.3.2.3) LICENSE NUMBER: New Package License
v
c
= 2 (f
c
')
0.5
= 190 psi
A
v
= 0.8 A = 204.4
in
2
131 psi v
u
= [V
u
+ T
u
/ (0.5D - T) ] / A
v
=
-1000.0
-500.0
0.0
500.0
1000.0
1500.0
2000.0
0.0 100.0 200.0 300.0 400.0 500.0 600.0 700.0
e
te
P M
P
f
A A S
= + =
e
pe
P M
P
f
A A S
= + + =
( )
'
'
2
'
'
2 0.85
, 57 , 29000
0.85 2 , 0
0.85 ,
,
,
,
C
C
C
C
C
S
PS
f
ksi f E E
c s o
E
c
c c
for f
c o
f
o o
for f
c o
for E
s s s y
f
for f
s y y
P
e
Min f E F
s se s
A
ps
c
c c
c c
c c
c c
c c c
c c
c
= = =
(
| | | |
( < <
| |
= (
\ . \ .

>

=

>

| |
| = +
|
\ .

S-ar putea să vă placă și