DOC NO-
: :
15060
These Local Wall Stress Calculations are in accordance with the Kellogg method as applied to Cylindrical Pipe Attachments. The program calculates the stress ratio based on "1.5 x Hot Allowable Stress".
OD RUN PIPE RUN PIPE WALL THICKNESS CORROSION ALLOWANCE RE - PAD THICKNESS CORRODED PIPE WALL THICKNESS OD TRUNNION TRUNNION WALL THICKNESS ID TRUNNION LENGTH OF TRUNNION RADIAL LOAD LONGITUDINAL LOAD CIRCUMFERENTIAL LOAD INTERNAL PRESSURE HOT ALLOWABLE STRESS
Sustained
280 N Thermal
168.30 mm 7.11 mm 1.50 mm mm 4.72 mm 114.30 mm 6.0198 mm 106.77 mm 300 mm 14030 N 4210 N 3340 N 0.1 BarG 140.00 N/mm2
If only longitudinal, axial or circumferential forces are calculated, they should be multiplied by the friction coefficient to obtain load values in unrestrained directions. RADIAL STRESS LONGITUDINAL BENDING STRESS CIRCUMFERENTIAL BENDING STRESS PRESSURE STRESS = = = = 61.31 128.76 115.00 0.23 N/mm2 N/mm2 N/mm2 N/mm2
0.454
1.454
FAILED
Calc by:-
SPS
Chk'd:-
App'd:-
PVS