Sunteți pe pagina 1din 11

ABB FieldController 800F

Delivery?
August 2000 - with F2kV6.1

Redundancy?
Just use two AC800F, 2 Ethernet each modules equivalent

What's different to existing?


faster processor Redundancy possible beige Color with V6.1 and Future Versions

Fits to global Freelance installed base


ABB Automation
Page 1 <doc-id>

Evolution by Enhancement
Freelance 2000
Existing Integration of Freelance 2000 System FDT/DTM
D-ES

D-OS

Add high scale operator interface

Local HSI Configuration Tool

Maestro-NT

Config. Download

FieldController
S800 I/O Profibus DPV1

AC 800F

Redundant FieldController AC 800F

S900 I/O

Rack CPU

HART

Add. new S900

ABB Automation
Page 3 <doc-id>

Evolution by Enhancement
Freelance 2000
Integration of FF configuration

D-OS

Maestro-NT

FieldController
S800 I/O HSE Profibus DPV1 FIO 100 FF-H1

AC800F

Add FFconnectivity to AC 800F

S900 I/O

Rack CPU

HART

ABB Automation
Page 4 <doc-id>

Redundancy Link Module RLM 01


Features: Conversion of one single to two redundant lines and vice versa Profibus DP or FMS Automatic line selection RS 485 9,6 kbit/s ... 12 Mbit/s Power supply 24 VDC DIN rail mounting LED status indication Digital output for red. failure Delivery: 4Q99

ABB Automation
Page 5 <doc-id>

Profibus Line Redundancy 1


DigiTool DigiVis

Profibus Line redundancy

Ethernet

AC800F

Supporting Field devices with non-redundant and redundant Profibus - Interface

RLM 01

RLM 01 S900 S800

ABB Automation
Page 7 <doc-id>

Slave without redundant interface

Profibus Line Redundancy 2


DigiTool

DigiVis

Profibus Line redundancy via Fiber Optic Ring


(e.g. Hirschmann OZD Profi 12M)

Ethernet

AC800F

OZD

Profibus Fiber Optic Ring

S900

ABB Automation
Page 8 <doc-id>

S800

Transmitter

Controller

Controller & Master Redundancy


DigiTool
DigiVis

CPU-Redundancy using two FieldController Profibus Master Redundancy

Ethernet

AC800F

S900

S800

Transmitter

Controller

ABB Automation
Page 9 <doc-id>

Controller & Master & Line Redundancy 1


DigiTool DigiVis

CPU-Redundancy using two FieldController

Ethernet

Profibus Master Redundancy


Supporting Field devices with non-redundant and redundant Profibus - Interface

AC800F

RLM 01

RLM 01 S900

RLM 01

ABB Automation
Page 10 <doc-id>

PLC

S800

Flexible System Limits


Local OS 1 Central OS Local OS

100

...

...

...

...
1

...
100

...

ABB Automation
Page 12 <doc-id>

FDT/DTM Support

Field Device Tool

DigiTool

HART

Device Type Managers


ABB Automation
Page 13 <doc-id>

HART

Trend & Archiving of Variables


Unlimited amount of Trends per Operator Station For all Variables in the System, even via OPC Without Trend Acquisition Blocks Archives on all DigiVis PCs (Redundancy) in Addition to existing Solution ABB Automation
Page 14 <doc-id>