Documente Academic
Documente Profesional
Documente Cultură
Prof. dr. ing., dr. HC, Dan DUBIN MC al Academiei Romne Universitatea Politehnica din Timioara
ABSTRACT. According to the Eurocodes, the fire resistance of steel and composite steel-concrete structures may be determined using simplified methods based on tabulated data or formulas. For special situations, as in case of complex cross-sections, it may be necessary to use an advanced numerical analysis, using special purpose programs (advanced calculation models) able to perform a thermal and mechanical analysis of structures under elevated temperatures. The computer programs which use such advanced calculation models must fulfil certain conditions imposed by the Eurocodes and must be validated through relevant test results, in order to demonstrate the capacity of the program to reproduce the fire behaviour of a specific category of problems. Once validated for such a specific category, it is not necessary to validate the program through tests for a similar problem, but it is obvious that if experimental evidence exists for a particular situation, a supplementary validation of the program may be considered. The paper presents such a supplementary validation of the advanced calculation model SAFIR, for the verification of the fire resistance of the columns of Bucharest Tower Center building. Keywords: fire resistance, numerical analysis, validation of the calculation model, composite section. REZUMAT. n conformitate cu standardele europene Eurocode, rezistena la foc a construciilor metalice i mixte oel-beton poate fi determinat utiliznd metode simplificate, pe baz de tabele sau formule de calcul. Pentru situaii deosebite, n cazul unor seciuni/ structuri complexe sau a unor cerine particulare, poate fi necesar efectuarea unei analize numerice avansate utiliznd programe de calcul specializate n analiza termic i mecanic a structurilor supuse la aciunea temperaturilor nalte. Modelele de calcul avansat implementate n programele specializate de calcul trebuie s ndeplineasc anumite cerine, impuse n standardele europene i trebuie validate prin ncercri experimentale relevante, pentru a demonstra capacitatea programului de calcul de a reproduce o comportarea la foc a unei anumite categorii de probleme. Odat ce programul a fost validat pentru o categorie de probleme nu se mai impune ca pentru o problem de acelai tip s se fac un nou experiment la foc, dar este evidenta c, n condiiile n care exista ncercri la foc pentru o situaie particular, asemntoare situaiei analizate, se poate face o validare suplimentar a modelului de calcul avansat. Articolul prezint o astfel de validare suplimentar a modelului de calcul avansat SAFIR pentru situaia particular a verificrii la foc a stlpilor structurii Bucharest Tower Center. Cuvinte cheie: rezisten la foc, analiz numerica, validare model de calcul, seciune compozit.
1. INTRODUCERE
Printr-un contract ncheiat ntre S.C. SIGUR CONSTRUCT S.R.L., reprezentat de ctre Dr. ing. Dan Victor Dumitrescu i Universitatea Politehnica din Timisoara, colectiv de elaborare prof. dr. ing. Dan Dubina i conf. dr. ing. Raul Zaharia, s-a solicitat verificarea prin calcul numeric n conformitate cu prevederile EN1993-1-2 i EN1994-1-2 a rezistenei la foc a elementelor structurale ale cldirii Bucharest Tower Building din Bucureti, str. Ion Mihalache, nr. 17. Evaluarea rezistenei la foc s-a efectuat conform contractului menionat pentru stlpii din profile din oel I n cruce maltez umplui cu beton armat ntre tlpile aparente ale profilelor metalice. Concluziile calculului s-au cerut a fi raportate la exigenele cerinei eseniale de calitate C Securitate la incendiu, pentru cldiri de gradul I de rezisten la foc, adic 2.5 ore (R 150)
14
pentru stlpi. Pentru efectuarea calculului numeric solicitat, datele referitoare la alctuirea elementelor structurii de rezisten i la eforturile care acioneaz asupra acestora, rezultate din combinaia de ncrcri specific unui calcul la aciunea focului au fost furnizate de ctre proiectantul structurii de rezisten, S.C. BRITT S.R.L. Verificarea s-a efectuat cu programul de calcul SAFIR [1], care opereaz cu un model de calcul avansat pentru analiz structural la aciunea focului, sub aciunea curbei standardizate temperatur timp ISO. Articolele 4.3.4 din SR EN1993-1-2; 2006 Eurocod 3: Proiectarea structurilor din otel. Partea 1-2: Reguli generale. Calculul structurilor la foc [2], respectiv 4.4.4 din SR EN1994-1-2;2006 Eurocod 4 Proiectarea structurilor compozite de oel si beton. Partea 1-2: Reguli generale. Calculul structurilor la foc [3], se refer la validarea modelelor de calcul avansat
Buletinul AGIR nr. 2/2011 aprilie-iunie
topologie similar stlpilor utilizai n structura Bucharest Tower Center, raportul menionat a demonstrat, pe baza ncercrilor fcute de ctre ARBED-RECHERCHES Luxembourg, o rezisten la foc de peste 170 minute sub aciunea focului standard ISO, fara protecie la foc suplimentar. Lucrarea prezint succint metodele de calcul a rezistentei la foc a structurilor pentru construcii, condiiile pe care trebuie sa le ndeplineasc un model de calcul avansat pentru a putea fi utilizat n calcul, precum si validarea suplimentar a programului de analiz numeric a structurilor solicitate la foc SAFIR. Validarea se realizeaz [7] utiliznd rezultatele unei ncercri la foc relevante pentru verificarea prin calcul numeric a rezistenei la foc a stlpilor structurii Bucharest Tower Center, si anume ncercarea la foc a stlpului octogonal cu profile din oel dispuse n cruce, cu beton ntre tlpile aparente ale profilelor din oel, testat de ctre ARBED-RECHERCHES Luxembourg.
CALITATE. COMPETITIVITATE
Curba standard temperatur-timp se determin cu relaia: Verificarea n domeniul temperaturii se face verificarea ca la timpul cerut de rezistenta la foc treq temperatura pe seciunea elementului este mai mic dect temperatura critic: < cr pentru t=treq Ultimul tip de verificare este destinat exclusiv elementelor din otel. Temperatura critic pentru un element structural din otel este temperatura atinsa n seciunea transversal pentru care rezistenta diminuata corespunztor acestei temperaturi egaleaz efortul unitar de solicitare, rezultat din combinaia excepional de incendiu. Aceasta verificare este valabila pentru elemente pentru care nu trebuie luate n considerare criterii de deformaie sau fenomene de pierdere a stabilitii. Este de subliniat ca protecia termic a unui element structural din oel, care trebuie aleasa astfel nct pe durata impusa de rezistenta la aciunea focului temperatura n seciune sa nu ating temperatura corespunztoare cedrii elementului, se determina n consecina nu doar funcie de masivitatea seciunii transversale, dar i de gradul de solicitare al elementului respectiv. O alternativ la utilizarea proteciei termice pentru elementele metalice este i utilizarea soluiilor constructive cu elemente cu seciune compusa otelbeton. Aceasta soluie are dublul avantaj c betonul armat sporete capacitatea portant a elementului, att la temperatura normal ct i n situaia de incendiu i ca prin prezenta betonului seciunea se nclzete mai lent, cu avantaje directe n situaia de incendiu. Normele europene ofer, n general, trei metode de calcul al rezistentei la aciunea focului: Metoda tabelara are la baza observaiile fcute n timpul experimentelor. Este foarte simpl de utilizat, domeniul de aplicabilitate fiind ns limitat, datorit unui ansamblu de condiii geometrice impuse seciunilor. Aceast metod se aplica n mod uzual n cazul elementelor din beton sau mixte otel beton, dar nu este prezent n normativul EN1993-1-2 pentru calculul elementelor din otel la aciunea focului. Metode simplificate de calcul permit calculul capacitii portante ultime pe baza unor formule (in principal pentru elementele din otel) sau nomograme de calcul (pentru elementele din beton sau compozite otelbeton), calibrate pe baza a numeroase ncercri experimentale. Metoda general de calcul presupune analiza numeric cu ajutorul unor modele avansate de calcul Buletinul AGIR nr. 2/2011 aprilie-iunie
[oC]
unde: g ,t este temperatura gazelor fierbini n cuptorul de ncercri la foc, n vecintatea elementului expus la foc, la timpul t, n oC; t timpul expunerii la foc, n minute. Incendiul este considerat o aciune excepionala si, la fel ca n cazul ncrcrii seismice, se considera coeficieni de calcul redui ai aciunilor, fata de calculul la starea limita n combinaia fundamental. Pentru a obine ncrcarea de calcul, relevant n cazul aciunii focului, cu care se determin efortul de calcul la starea limit de incendiu Efi,d, se utilizeaz urmtoarea combinaie accidental:
GA
G k 1,1Q k ,1 2,i Q k ,i
unde: Gk este valoarea caracteristic a ncrcrii permanente; Qk ,1 valoarea caracteristic a ncrcrii variabile dominante; Qk ,i valorile caracteristice ale celorlalte ncrcri variabile; GA coeficientul parial de siguran pentru ncrcrile permanente la starea limit de incendiu, GA =1,0; 1,1 este coeficientul de combinare pentru ncrcarea variabil dominant; 2,i coeficientul de combinare pentru restul ncrcrilor variabile. In principiu, exista trei posibiliti de verificare a capacitii portante a unui element structural sub aciunea focului: Verificarea n domeniul timpului se face verificarea ca timpul corespunztor ruinei elementului tf este superior timpului cerut de rezistenta la foc treq: tf>treq Timpul corespunztor ruinei elementului este timpul pentru care rezistenta elementului supus aciunii temperaturilor nalte atinge efortul de calcul corespunztor produs de ncrcri n situaia de incendiu. Verificarea n domeniul ncrcrii se face verificarea c la timpul cerut de rezistenta la foc treq rezistena elementului Rd,fi este superioar efortului de calcul produs de ncrcri n situaia de incendiu: Rd,fi > Ed,fi
16
pentru t = treq
permite o analiz structurala neliniar, n pai de timp corespunztori creterii temperaturii pe seciune transversal, sub aciunea ncrcrilor statice constante sau variabile n timp. Calculul timpului de rezisten la aciunea focului a unui element structural se face n dou etape: n prima etap se determina evoluia temperaturii pe seciunea transversal a elementelor, innd astfel cont de degradarea caracteristicilor mecanice ale materialelor ce compun seciunea; n etapa a doua se stabilete rspunsul elementului structural sub aciunea ncrcrilor termice i a ncrcrilor statice maxime obinute din combinaiile corespunztoare gruprii speciale de incendiu.
CALITATE. COMPETITIVITATE
Caracteristicile de material pentru beton au fost determinate pe cuburi de 200 mm testate la date apropiate de data ncercrii la foc. Rezistenele obinute astfel s-au utilizat pentru calculul rezistenei bazate pe specimene cilindrice de 150 mm diametru i 300 mm nlime, n conformitate cu specificaiile C.E.B. (1964) n vigoare la vremea respectiv. Rezistena la compresiune astfel obinut cy = 51,90 N/mm2, a fost rezistena de referin a betonului, considerat n test i pentru calculul numeric cu programul SAFIR. Limita de curgere caracteristic a oelului, determinat pe probe prelevate din profilele din oel utilizate n test i considerata n calculul numeric cu programul SAFIR a fost fy = 299,90 N/mm2. Pentru specimenul experimental al stlpului octogonal, coninutul de ap al betonului, a fost de 80 l/m3. Stlpul cu seciune octogonal testat nu a prezentat, n urma msurtorilor, nici o imperfeciune iniial pe lungimea specimenului experimental (nici o abatere de la rectilinitate). Pe suprafeele expuse la foc, fluxul net de cldur se determin innd seama de transferul de cldur prin convecie i radiaie n conformitate cu paragraful 3.1 din SR EN1991-1-2 Eurocod 1: Aciuni asupra structurilor. Partea 1-2: Aciuni generale Aciuni asupra structurilor expuse la foc [8]. Acesta depinde de emisivitatea rezultant ca produs ntre emisivitatea incendiului i emisivitatea suprafeei elementului. Emisivitatea rezultant, n cazul unei ncercri la foc, depinde de poziia arztoarelor n raport cu specimenul experimental, dimensiunile cuptorului, combustibilul utilizat i caracteristicile pereilor cuptorului. n Figura 2 sunt date valorile emisivitilor rezultante considerate pentru suprafeele din oel aparente (0,3 i 0,5), respectiv suprafeele din beton (0,45) pentru stlpul octogonal, ncercat n condiiile specifice ale cuptorului de ncercri la foc de la Universitatea din Gent, aa cum au fost date n raportul ARBED (fig. 32 din raport). Aceste valori au fost considerate i n calculul numeric cu programul SAFIR.
Fig. 2. Emisivitile rezultante pentru tlpile din oel i suprafeele din beton ale stlpului ncercat n cuptorul Universitii din Gent [6].
18
Fig. 3. Distribuia temperaturilor pe seciunea transversal i n dreptul termocuplelor, prin calcul numeric cu programul SAFIR, la timpul de 172 minute (10 320 secunde), comparativ cu rezultatele experimentale [6].
n cazul considerrii unei lungimi de flambaj de 70% din lungimea stlpului (situaia intermediar, a rezemrii articulat-ncastrate a stlpului, ntre situaia stlpului cu rezemare perfect articulat, respectiv perfect ncastrat la ambele capete) timpul de cedare obinut prin calcul numeric este de 164 minute, rezultat n continuare conservativ, dar mai apropiat de timpul de cedare determinat experimental. Aceasta ar putea sugera
19
CALITATE. COMPETITIVITATE
ca, n mod real, pentru specimenul experimental nu s-au putut realiza pentru rezemri articulaii perfecte i c a existat un anumit grad de ncastrare la capetele specimenului experimental. Este de menionat faptul c stlpul este zvelt (avnd n vedere lungimea acestuia i caracteristicile seciunii transversale) i prin urmare comportamentul acestuia poate fi afectat n condiiile n care rezemrile asigura un oarecare grad de ncastrare la capete. Este evident ca este imposibil de tiut cu exactitate nivelul de ncastrare la capete realizat de prinderile specimenului experimental. n continuare, n analiza de sensibilitate a modelului de calcul la nivelul altor parametrii critici, se va considera drept referina situaia intermediar a barei articulat ncastrate, care poate fi considerata mai aproape de situaia real a condiiilor ncercrii experimentale. n cazul considerrii unei lungimi de flambaj corespunztoare situaiei barei dublu ncastrate (50% din lungimea stlpului) timpul de cedare obinut prin calcul numeric este de 188 minute. Se observ c timpul de cedare este superior timpului obinut experimental, ceea ce este evident, deoarece, n montajul experimental nu s-a putut (i nici nu s-a dorit) obinerea unei ncastrri perfecte, orict de mare ar fi fost gradul de ncastrare real de la capetele specimenului, avnd n vedere detaliile de prindere realizate (fig. 1). n concluzie, n urma analizei de sensibilitate efectuat la nivelul lungimilor de flambaj (parametru critic pentru determinarea rezistenei la foc a unui element structural), s-a demonstrat faptul c modelul de calcul avansat SAFIR ofer rezultate conforme cu principiile inginereti: timpul de cedare rezultat prin calcul numeric crete odat cu scderea lungimii de flambaj a stlpului. Privitor la amplitudinea imperfeciunilor iniiale, dei stlpul cu seciune octogonal testat nu a prezentat, n urma msurtorilor, nici o imperfeciune iniial pe lungimea specimenului experimental (nici o abatere de la rectilinitate), n calculele numerice s-a considerat o imperfeciune global general cu amplitudinea de 1 mm. n ipoteza utilitarii unei imperfeciuni iniiale cu amplitudine de 1/1000 din lungimea elementului (n conformitate cu prevederile articolului 4.3.3(7) din SR EN1993-1-2, referitor la analiza cu ajutorul modelelor de calcul avansat a elementelor izolate verticale), superioare valorii de 1 mm considerat iniial n calcul, se obine un timp de cedare inferior, pentru ipoteza stlpului articulat-ncastrat, de 156 minute. n verificarea prin calcul numeric a stlpilor structurii Bucharest Tower Center s-au considerat imperfeciuni globale ale elementului, corespunztoare imperfeciunilor echivalente date de SR EN 1993-1-1, Eurocode 3: "Design of steel structures" pentru seciuni I,
20
n conformitate cu paragrafele 5.3.2 (3) i 6.3.1.2 (2), respectiv date de SR EN1994-1-1 [9], Tabelul 6.5 pentru seciuni parial nglobate n beton cu seciuni I n cruce (cazul stlpilor structurii Bucharest Tower Center). Valoarea amplitudinii imperfeciunilor globale introduse pe elemente a fost, n conformitate cu referinele de mai sus, de 1/200 din lungimea elementului. n ipoteza utilizrii unei imperfeciuni iniiale cu amplitudine de 1/200 din lungimea elementului, superioare valorii de 1mm considerat iniial n calcul, respectiv valorii 1/1000 din lungimea stlpului, pentru stlpul de referin articulat-ncastrat, se obine un timp de cedare inferior, de 140 minute. n concluzie, urma analizei de sensibilitate efectuat la nivelul amplitudinii imperfeciunilor iniiale (parametru critic pentru determinarea rezistenei la foc a unui element structural), s-a demonstrat faptul ca modelul de calcul avansat SAFIR ofer rezultate conforme cu principiile inginereti: timpul de cedare rezultat prin calcul numeric scade odat cu creterea amplitudinii imperfeciunilor iniiale a stlpului. Timpul de cedare scade de la 164 minute pentru o imperfeciune cu o amplitudine de 1 mm (n condiiile n care imperfeciunile msurate experimental au fost 0), la 156 minute pentru o imperfeciune cu o amplitudine mai mare, de 1/1000 din lungimea stlpului, respectiv la 140 minute pentru o imperfeciune cu valoarea maxima considerat, de 1/200 din lungimea stlpului. Se subliniaz faptul c, aa cum demonstreaz i analiza de sensibilitate, imperfeciunile iniiale cu amplitudinea de 1/200 din lungimea stlpilor, considerate n verificarea prin calcul numeric a rezistenei la foc a stlpilor structurii Bucharest Tower Center, au fost acoperitoare pentru rezultatele calculului. Aa cum s-a artat, emisivitile rezultante ale oelului i betonului, n conformitate cu SR EN1991-1-2 au valoarea 0,7 (considernd c pentru emisivitatea incendiului se poate considera n general valoarea 1,00), valoare superioar (acoperitoare) fa de emisivitile determinate pentru stlpul octogonal ncercat n cuptorul laboratorului Universitii din Gent. n figura 4 se prezint distribuia temperaturilor pe seciunea transversala, pentru timpul de cedare al specimenului experimental de 172 minute (10 320 secunde) n cazul considerrii unei emisiviti rezultante pe tot perimetrul stlpului cu valoarea 0,7. Se observ c valorile temperaturilor sunt mai mari, deci acoperitoare, n comparaie cu valorile temperaturilor rezultate prin calcul numeric pentru valori ale emisivitailor determinate n laboratorul din Gent, de 0,45 pentru suprafaa de beton, respectiv de 0,3 i 0,5 pentru suprafeele tlpilor de oel (fig. 3).
Buletinul AGIR nr. 2/2011 aprilie-iunie
5. CONCLUZII
Programul pentru analiza numeric a structurilor solicitate la aciunea focului SAFIR este un program recunoscut i utilizat la nivel internaional, care respect principiile enunate de Eurocoduri pentru a fi considerat un model de calcul avansat pentru acest tip de analiz. n conformitate cu condiiile enunate de Eurocoduri pentru validarea modelelor de calcul avansat, programul SAFIR a fost validat prin numeroase comparaii att cu ncercri la foc ct i cu alte programe recunoscute. Pentru cazul verificrii prin calcul numeric a stlpilor structurii Bucharest Tower Center, s-a considerat o validare suplimentar a modelului de calcul avansat, prin comparaia rezultatelor oferite de programul SAFIR cu o ncercare relevant, pentru un stlp testat experimental la foc la Universitatea din Gent, Belgia, stlp cu o tipologie similar stlpilor structurii Bucharest Tower Center (profile din oel I dispuse n cruce, cu beton ntre tlpile aparente, neprotejate, ale profilelor din oel). Aa cum era de ateptat, programul SAFIR a oferit, prin comparaie cu ncercarea experimental, rezultate bune, cu valori acoperitoare, att pentru temperaturile calculate n dreptul termocuplelor utilizate la determinarea experimental a temperaturii pe seciunea transversal, cat i pentru timpul de rezisten la foc. n urma analizei de sensibilitate, necesare pentru validarea unui model de calcul avansat, dar care se poate face i pentru o situaie particular, s-a evideniat ca programul SAFIR ofer rezultate conforme cu principiile inginereti. Analiza de sensibilitate s-a efectuat considernd diveri parametrii critici pentru determinarea rezistenei la foc a unui element structural: lungimi de flambaj, imperfeciuni geometrice echivalente i emisiviti rezultante. n verificarea la foc a stlpilor structurii Bucharest Tower Center s-au considerat toi parametrii critici enumerai anterior, cu valori care s conduc la rezultate acoperitoare n ceea ce privete timpul de rezisten la foc. Astfel, n calculul numeric, lungimile de flambaj ale stlpilor s-au considerat egale cu lungimile elementelor (ipoteza prinderii biarticulate a stlpilor), amplitudinea imperfeciunilor geometrice echivalente s-a considerat 1/200 din lungimea elementelor, iar valorile emisivitilor rezultante s-au considerat cele indicate de Eurocoduri. Toate aceste ipoteze s-au demonstrat a fi acoperitoare n urma calculului numeric
21
Fig. 4. Distribuia temperaturilor pe seciunea transversal, corespunztoare timpului de cedare al specimenului experimental de 172 minute (10320 secunde) considernd emisivitile rezultante de 0.70 pentru suprafeele expuse de beton i oel.
Timpul de cedare rezultat din calcul numeric, pentru stlpul de referin (lungimea de flambaj corespunztoare situaiei barei articulat-ncastrate, cu amplitudinea imperfeciunii globale de 1mm), considernd valorile emisivitilor rezultante de 0,70 pentru suprafeele expuse de beton i de oel este de 152 minute. n concluzie, n urma analizei de sensibilitate efectuat la nivelul emisivitilor rezultante ale suprafeelor de beton i oel, s-a demonstrat faptul ca modelul de calcul avansat SAFIR ofer rezultate conforme cu principiile inginereti: timpul de cedare rezultat prin calcul numeric scade odat cu creterea valorilor emisivitilor rezultante. Timpul de cedare scade de la 164 minute pentru emisivitile rezultante de 0,45 pentru beton, respectiv 0,3 i 0,5 pentru oel (determinate pentru cuptorul de ncercri la foc a Universitii din Gent), la 152 minute pentru emisivitile rezultante de 0.70 pentru oel i beton, aa cum sunt prevzute n SR EN1991-1-2. Valorile mai mari ale emisivitilor, presupun o component majorat din radiaie a fluxului termic net de cldur pe unitatea de suprafa, ceea ce, aa cum s-a demonstrat i prin calculul numeric, conduce la apariia de temperaturi mai mari pe seciunea transversal i deci la un timp de cedare inferior al elementului. Se subliniaz faptul c, aa cum demonstreaz i analiza de sensibilitate, valorile emisivitilor rezultante considerate n conformitate cu prevederile SR EN1991-1-2 pentru verificarea prin calcul numeric a rezistenei la foc a stlpilor structurii
Buletinul AGIR nr. 2/2011 aprilie-iunie
CALITATE. COMPETITIVITATE
prezentat, att n urma analizei de sensibilitate, ct i prin comparaie cu ncercarea experimental. n concluzie, se poate considera ca modelul de calcul avansat SAFIR este validat i pentru situaia particular a stlpilor structurii Bucharest Tower Center, pentru verificarea crora s-au ales toate ipotezele de calcul care conduc spre rezultate acoperitoare din punct de vedere al timpului de rezisten la foc.
structures, ICSCS07, Manchester, UK, Taylor & Francis/ Balkema, ISBN978-0-415-45141-3 [5] Zaharia R., Dubina D., Aspecte ale calculului structurilor din otel i moxte otel beton la actiunea focului n contextul prevederilor normelor Eurocode Revista Asociatiei Inginerilor Proiectanti de Structuri AICPS, ISSN 1454 928X, No. 2, p. 148, 2006 [6] C.E.C. Agreement Number N 7210-SA/502, Computer assisted analysis cf the fire resistance of steel and composite concretesteel structures (REFAO - CAFIR), Commission of the European Communities, Directorate-General, Science, Research and Development, EUR 10828 EN, ECSC-EEC-EAEC, Brussels Luxembourg, 1987 [7] Zaharia R., Dubina D., Duma D., Validarea unui model de calcul avansat pentru analiza structurilor solicitate la actiunea focului, Realizari i preocupari actuale n ingineria constructiilor metalice, A XII-a Conferina National de Construcii Metalice, Timioara, 26-27 Noiembrie 2010, Editura Orizonturi Universitare, ISBN 978-973-638-464-6, 2010 [8] SR EN1991-1-2, Eurocod 1: Aciuni asupra structurilor. Partea 1-2: Aciuni generale Aciuni asupra structurilor expuse la foc [9] SR EN1994-1-1, Eurocod 4: Proiectarea structurilor compozite de otel i beton. Partea 1-1: Reguli generale i reguli pentru cldiri, ASRO 2006
BIBLIOGRAFIE
[1] Franssen J. M. (2005), Safir A thermal/structural program modelling structures under fire, Engineering Journal, AISC, Vol. 42, No 3, 143-158 [2] SR EN1993-1-2; 2006 Eurocod 3: Proiectarea structurilor din oel. Partea 1-2: Reguli generale. Calculul structurilor la foc, ASRO 2006 [3] SR EN1994-1-2;2006 Eurocod 4 Proiectarea structurilor compozite de oel i beton. Partea 1-2: Reguli generale. Calculul structurilor la foc, ASRO 2006 [4] Zaharia R. , Pintea D., Dubina D., Fire analysis and design of a composite steel-concrete structure, Steel and Composite
22