Alternator principle
Alternator principle
Alternator principle
Alternator principle
Alternator principle
ALTERNATOR PRINCIPLE
STATOR WINDING
ROTOR
WINDING
ALTERNATOR PRINCIPLE
STATOR WINDING
ROTOR WINDING
DIRECT CURRENT
ALTERNATIVE CURRENT
ALTERNATOR PRINCIPLE
EXCITER FIELD
RECTIFIERS
STATOR WINDING
ROTOR WINDING
DIRECT CURRENT
ALTERNATIVE CURRENT
SHUNT PRINCIPLE
EXCITER FIELD
RECTIFIERS
STATOR WINDING
ROTOR WINDING
DIRECT CURRENT
ALTERNATIVE CURRENT
RECTIFIERS
STATOR WINDING
ROTOR WINDING
DIRECT CURRENT
ALTERNATIVE CURRENT
AREP PRINCIPLE
EXCITER FIELD
RECTIFIERS
STATOR WINDING
ROTOR WINDING
ALTERNATIVE CURRENT
DIRECT CURRENT
COMPOUND PRINCIPLE
RECTIFIERS EXCITER FIELD
STATOR WINDING
ROTOR WINDING
COMPOUNDING TRANSFORMER
A.V.R.
ALTERNATIVE CURRENT
DIRECT CURRENT
Phase of Electricity
Star connection
Delta connection
Phase of Electricity
Single phase AC circuit: Two wires connected to electricity source Direction of current changes many times per second
3-phases of an electric system (Wikipedia contributors, 2005)
Three phase systems: 3 lines with electricity from 3 circuits One neutral line 3 waveforms offset in time: 50-60 cycles/second
POWER FACTOR
kW = ACTIVE POWER kVA = POWER kV AR = REACTIVE POWER INDUCTIVE P.F. = INDUCTIVE LOAD, ASYNCHRONOUS MOTOR, TRANSFORMER ... (CURRENT IS LATE COMPARED TO THE VOLTAGE) CAPACITIVE POWER FACTOR : FLUORESCENT LIGHT, CAPACITOR ... (CURRENT IS FAST ON THE VOLTAGE)
Ausonia srl After sales technical service APR. 2009 Page 16
GENSETS
h
Ausonia srl After sales technical service APR. 2009 Page 17
ALTERNATOR RATINGS
CONTINUOUS DUTY S1/ 40C - IEC 34.1 DEFINITION RUNNING AT CONSTANT LOAD LIMITED TO THE INSULATION CLASS PERMISSIBLE OVERLOAD 1 H EVERY 6 HOURS
STAND BY DUTY 40C - RUNNING AT CONSTANT LOAD WITHOUT OVER LOAD FOR A LIMITED DURATION OF MAXIMUM 500H/YEAR WITH A PERMISSIBLE INCREASE OF THE TEMPERATURE RISE ABOVE CLASS H STAND BY DUTY 27C - SAME CONDITIONS THAN STAND BY DUTY 40C BUT WITH ACCEPTANCE OF A LOWER AMBIENT TEMPERATURE (27C) THAT ALLOWS TO INCREASE THE RATING AND THE TEMPERATURE RISE FOR THE SAME LEVEL OF TEMPERATURE IN THE GENERATOR EX: S1/40C = 100 KW - STD BY/40C = 105 KW - STD BY/27C = 110 KW
FREQUENCY
FREQUENCY (Hz) =
MAIN FREQUENCIES :
ALTERNATOR SPEED
SPEED IN MN -1 OR R.P.M. 2P 4P 6P 8P 10P 12P 14P 16P
50 Hz 3000 1500 1000 750 600 500 428 375 60 Hz 3600 1800 1200 900 720 600 514 450 DIRECTION OF ROTATION STANDARD : CLOCKWISE LOOKING FROM THE DRIVE END
ALTERNATOR RATINGS
ACTIVE POWER : KW
P = 3 UI Cos j (3 phase) KW
RATED POWER : kVA
ENGINE
Alternator parts
Main Generators Parts & Assembling
Rotor Assembling
Cooling Fan
Main rotor
Rotating Diode
Ext. Rotor
Ext. Stator
Main stator
Frame
Terminal Box
Permanent magnetic
Air outlet
Air inlet