APPENDIX C - NTMF01 TERMINATION UNIT CONFIGURATION

INTRODUCTION
The INICT01 INFI-NET to Computer Transfer Module (ICT) uses the NTMF01 Multi-Function Controller Termination Unit for termination. Figure C-1 shows the dipshunt configuration required when connecting an ICT module (DCE) directly to the host computer (DTE) via a cable. Figure C-2 shows the dipshunt configuration required when connecting an ICT module (DTE) to a modem (DCE). Figure C-3 shows the dipshunt configuration required to interface to a mainframe computer. Figure C-4 shows how to configure the TMF unit so that port 2 can drive a diagnostics terminal. Figure C-5 shows the RS-232-C signals and the associated DB-25 connector pin assignments. Refer to the NTMF01 instruction for complete information.

+24 VDC RTS 4

FUNCTION

J1 PIN

XU1

DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

+V/9 2 3 4 5 5 6 20 +V/9 12

TXD RXD CTS DCD

2 3 5 8 9

PORT 1

ICT MUST USE P1 CONNECTOR XU2


J1 XU1

P1 CONNECTOR
XU2

TERMINAL PORT 1

SRD/16 BUSY/25 1 GND 1 20 DSR 6 6 8 5 4 3 2 +24 VDC RTS 4

STATION COMMUNICATION P2 CONNECTOR F1 FUSE +24 V (E2) I/O COMMON (E3)


XU3 XU4 J2

FUNCTION
DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

J2 PIN
+V/9 2 3 4 5 5 6 20 +V/9 12

PRINTER PORT 2 XU3

TXD RXD CTS DCD

2 3 5 8 9

P3 CONNECTOR

PORT 2

IBM PC/COMPAQ AND COMPATIBLE COMPUTERS (TMF ACTING AS DCE)

XU4

SRD/16 BUSY/25 1 GND 1 20 6 DSR 6 8 5 4 3 2

T00383A

Figure C-1. NTMF01 Dipshunt Configuration for Direct Connection to a Host Computer

I-E96-610A

INTRODUCTION C-1

NTMF01 TERMINATION UNIT CONFIGURATION

+24 VDC

FUNCTION

J1 PIN

XU1

DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

+V/9 2 3 4 5 5 6 20 +V/9 12 SRD/16 BUSY/25 1 20 6 8 5 CTS RTS 4 3 RXD TXD 2

CABLE SHIELDING GROUND 1 DB-25 PIN ASSIGNMENT

ICT MUST USE P1 CONNECTOR XU2


J1 XU1

PORT 1

P1 CONNECTOR
XU2

TERMINAL PORT 1

5 4 3 2

STATION COMMUNICATION P2 CONNECTOR F1 FUSE +24 V (E2) I/O COMMON (E3)


XU3 XU4 J2

+24 VDC

FUNCTION
DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

J2 PIN
+V/9 2 3 4 5 5 6 20 +V/9 12

PRINTER PORT 2 XU3

P3 CONNECTOR

COMMUNICATION THROUGH A MODEM (TMF ACTING AS DTE)


NOTE: IF AN ISOLATING MODEM IS USED, PROTECTIVE GROUND AND SIGNAL COMMON GROUND OF THE MODEM CONNECTOR ARE TIED TOGETHER, DIPSHUNT STRAP GND OF XU2 AND XU4 MUST BE CUT. DOING THIS MAINTAINS THE ISOLATION OF DC COMMON AND SAFETY GROUND WITHIN THE INFI 90/NETWORK 90 SYSTEM.

XU4

SRD/16 BUSY/25 1 1 20 6 8 CTS 5 5 4 RTS 4 3 RXD 3 2 TXD 2

CABLE SHIELDING GROUND

PORT 2

DB-25 PIN ASSIGNMENT

T00382A

Figure C-2. NTMF01 Dipshunt Configuration for Direct Connection to a Modem

INTRODUCTION C-2

I-E96-610A

NTMF01 TERMINATION UNIT CONFIGURATION

+24 VDC

FUNCTION
DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

J1 PIN
+V/9 TXD 2 2 RXD 3 3 4 5 5 6 20 +V/9 9 12 SRD/16 BUSY/25 1 20 DSR 6 8 DCD CTS 5 4 3 2

XU1

PORT 1

ICT MUST USE P1 CONNECTOR XU2


J1 XU1

1 GND 6 8 5

P1 CONNECTOR
XU2

TERMINAL PORT 1

+24 VDC

STATION COMMUNICATION P2 CONNECTOR F1 FUSE +24 V (E2) I/O COMMON (E3)


XU3 XU4 J2

FUNCTION
DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

J2 PIN
+V/9 TXD 2 2 RXD 3 3 4 5 5 6 20 9 +V/9 12 SRD/16 BUSY/25 1 20 6 DSR 8 DCD CTS 5 4 3 2

PRINTER PORT 2 XU3

P3 CONNECTOR

PORT 2

1 GND 6 8 5

XU4

MAINFRAME (MODCOMP OR VAX)

T00381A

Figure C-3. NTMF01 Dipshunt Configuration for Direct Connection to Mainframe Computer

I-E96-610A

INTRODUCTION C-3

NTMF01 TERMINATION UNIT CONFIGURATION

ICT MUST USE P1 CONNECTOR


J1 XU1

P1 CONNECTOR
XU2

TERMINAL PORT 1
+24 VDC

STATION COMMUNICATION P2 CONNECTOR F1 FUSE +24 V (E2) I/O COMMON (E3)


XU3 XU4 J2

FUNCTION
DCD RXD TXD CTS RTS 4 TO 5 CTS CTS CTS J2-11 STD/14 RI/22 GND RTS CTS DCD CTS RTS RXD TXD

J2 PIN
+V/9 TXD 2 2 RXD 3 3 4 5 5 6 20 9 +V/9 12 SRD/16 BUSY/25 1 GND 1 20 6 DCD 8 8 CTS 5 5 4 3 2

PRINTER PORT 2 XU3

P3 CONNECTOR

PORT 2

XU4

PORT 2 ONLY FOR DIAGNOSTIC TERMINAL

T00380A

Figure C-4. NTMF01 Dipshunt Configuration for Diagnostic Terminal

INTRODUCTION C-4

I-E96-610A

NTMF01 TERMINATION UNIT CONFIGURATION

TXD RXD RTS CTS DCD

TRANSMIT DATA RECEIVE DATA REQUEST TO SEND CLEAR TO SEND RECEIVED LINE SIGNAL DETECT +24V

DTE
DCD RXD TXD CTS RTS CTS CTS CTS 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 SDCE 9 + VOLTS 12 SECONDARY RECEIVE SIGNAL DETECT CTS DCD 5 CLEAR TO SEND 8 RECEIVED LINE SIGNAL DETECT TD RD RTS 2 TRANSMIT DATA 3 RECEIVE DATA 4 REQUEST TO SEND

XU1 XU3

1 2 3 RTS CTS DCD CTS RTS RXD TXD 4 5 6 7 8 9 10

20 19 18 17

SRD

16 SECONDARY RECEIVE SIGNAL 25 BUSY 1 PROTECTIVE GROUND

DTR DSR

20 DATA TERMINAL READY 6 DATA SET READY

XU2 XU4

16 15 14 13 12 11

7 SIGNAL GROUND

DCE
22 RING DETECT STD QM 14 SECONDARY TRANSMITTED DATA 11 EQUALIZER MODE
T00375A

Figure C-5. NTMF01 DB-25 Connector Pin Assignments and RS-232-C Signals

I-E96-610A

INTRODUCTION C-5