3400 100 430 5mm CLEAR POLYCARBONATE ROOF COVERING.

SECURE TO RAFTERS ON-SITE USING SUITABLE SELF TAPPING SCREWS AT CTRS DETERMINETD BY ENGINEER. 3200 2340 430 100

5 20 100

1200 1160 960 100 400 50 300 50 20

40 DIA. x 2mm WALL STAINLESS STEEL TUBE. 100

PURLINS : 101.6 DIA. x 4mm WALL STAINLESS STEEL TUBE.

409

50

BASEPLATE : 15PL. x 400 x 400. 4 No. HOLES 24 DIA. FOR M20 RESIN ANCHORS. 400 460
45 45

STALK : 40 DIA. x 2mm WALL STAINLESS STEEL TUBE. CURVED RAFTERS : 101.6 DIA. x 4mm WALL STAINLESS STEEL TUBE.

300

RADIU S

4 00 0

OUTRIGGERS : 76.2 DIA. x 4mm WALL STAINLESS STEEL TUBE.

50

200

480 2659

BASEPLATE DETAIL

2250

2250

2150

5 NEOPRENE 70 20 DIA. STALK FROM MAIN POST.

211

1841

5mm THICK NEOPRENE BUFFER.

COLUMN : 141.6 DIA. x 6.5 WALL STAINLESS STEEL TUBE.

EXISTING DOOR IN 90 OPEN POSITION. PROPOSED DOOR HANDLE.

1900 OVER DOORS F.F.L. 200 F.F.L. 200 2340 POST CENTRES

69

S.S.L. 15 GROUT S.S.L.

DOOR-STOP DETAIL
600

600 x 600 x 600 CONCRETE FOUNDATION SUPPLIED BY OTHERS. DESIGN ENGINEER TO CONFIRM SIZE OF FOUNDATION.

600 1170 300 2340 1170

600 600 300 605 300

ELEVATION
DENOTES LOCATION OF LIGHT. CUT-OUT TO BE PROVIDED IN UNDERSIDE OF WALL-SIDE RAFTER TO ACCEPT LIGHT ONCE SPECIFICATION OF LIGHT HAS BEEN RECEIVED.

END ELEVATION

120

NOTES : THE ARCHITECT/CLEINT IS TO CONFIRM THAT THE PROPOSED SIZES FOR THE CANOPY ARE ACCEPTABLE AND FALL WITHIN THE REMIT OF THE CANOPY. 211 5 NEOPRENE 5 NEOPRENE 211 THE PROPOSED CANOPY STRUCTURE AND THE PROPOSED FOUNDATIONS ARE SUBJECT TO A FULL DESIGN CHECK BEING CARRIED OUT. A LIGHT IS TO BE LOCATED TO THE UNDERSIDE OF THE WALL-SIDE RAFTER. CUT-OUT/DRILLING DIMENSIONS TO BE CONFIRMED ONCE THE SPECIFICATION FOR THE LIGHT TO BE USED HAS BEEN RECEIVED. 5mm CLEAR POLYCARBONATE ROOF COVERING. SECURE TO RAFTERS ON-SITE USING SUITABLE SELF TAPPING SCREWS AT CTRS DETERMINETD BY ENGINEER. HOLES TO BE DRILLED IN THE CANOPY STRUCTURE TO ROUTE THE ELECTRICAL CABLES FOR THE PROPOSED LIGHT. POSITION AND SIZE IS YET TO BE DETERMINED. THE FOUNDATIONS ARE TO BE CAST BY OTHERS AND ONCE CANOPY IS IN POSITION THE FINISHED GROUNDWORKS ARE TO BE MADE GOOD BY OTHERS. THE CANOPY IS TO BE CONSTRUCTED AS ONE SOLID WELDED FABRICATION WITH THE POLYCARBONATE ROOF BEING SECURED TO THE CANOPY RAFTERS ON-SITE.

1200

960

120

480

480

80 220 1900 OVER DOORS IN OPEN POSITION 2060 MAX. OVER DOOR HANDLES 2340

80 220

PLAN VIEW
TITLE : SURFACE FINISH IN MICRONS TO BS 1134-1990 UNDIMENSIONED RADII - 1mm WELD SYMBOLS TO BS 449-1980 SYMBOLS AND DIMENSIONS ETC. TO BS 308-1993 WELDING TO BS 5135-1984 MARK WITH PART NUMBER AND ISSUE FABRICATION TOLERANCE : UPTO 300mm 300mm TO 1000mm ABOVE 1000mm 1.0mm 2.0mm 3.0mm
Drawing Produced By

PERSPECTIVE VIEW OF CANOPY STRUCTURE

Limited

GENERAL ARRANGEMENT & DETAILS OF MAIN ENTRANCE CANOPY


No. DESCRIPTION CHANGED APPROVED DATE THIS DRAWING IS THE EXCLUSIVE PROPERTY OF REDGATE ENGINEERING LIMITED AND MUST NOT BE COPIED OR LENT WITHOUT PRIOR WRITTEN CONSENT AND SHALL BE RETURNED UPON REQUEST

Redgate

DRAWN TRACED CHECKED APPROVED


DRAWING No. :

M. BROOKES

DATE DATE DATE DATE

200

....

SCALE : 1 : 15
CLIENT :

UNTOLERANCED MACHINE DIMENSIONS 0.25mm

Engineering

PROJECT :

REV. :

REVISIONS

ALL DIMENSIONS IN MILLIMETRES

PROJECTION

B.B.I.C., Snydale Road, Cudworth, Barnsley, South Yorkshire, S72 8RP Tel. : 01226 714106 Fax. : 01226 700722 Email : office@redgateengineering.co.uk

REL-563-090

SHEET 1 OF 1