GENERAL Model/Power Topology Control INPUT InputIsolationTransformer NominalVoltageandTolerance InputWiring NominalFrequency THDI PowerFactor InputProtection OUTPUT BatteryChargingPrinciple NominalPower FloatingOutputVoltage OutputVoltageAdjustment NominalOutputCurrent OutputCurrentAdjustment StaticTolerance OutputVoltageRippleRMS TotalharmonicDistortion(ThDi) Efficiencyatfullload BoostChargeVoltage Boostvoltage(V/C) Floatvoltage(V/C) DynamicResponse(w/outbatterygroup) DynamicResponse(withbatterygroup) OutputProtection Filtering CONTROLELEMENTS BatteryTest BoostTimer ALARMCONTACTS Openorclosedfreealarmcontacts DISPLAYPANEL&MEASUREMENT Measurements Indicators
ConstantCurrent/ConstantVoltage 3600watts 120VDC1% 120VDC 30ASystemcanbesetbetween0and30A 0100%ofNominalOutputCurrent <1% 1%RMSACofOutputVoltage <30% >90% 100%to120%ofFloatingOutputVoltage 2,4leadacidbattery1,60NiCdBattery 2,23leadacidbattery1,40NiCdbattery 10%ofOutputVoltageat200msec(100%loadchange) 2%ofOutputVoltageat200msec(100%loadchange) ShortCircuit,MCB(SchneiderActi9),Overvoltageprotectionandreversepolarityprotection LCFilter
Automaticormanualselectable.Pleaserefertousermanualfordetails 099,9hoursadjustableby1minuteaccuracy
Mainsswitchfailure, ,battery yswitchfailure, ,loadswitchfailure, ,lowbattery yfailure, ,lowoutput p voltage, g ,overoutput p voltage, g ,mains failure,chargerfailure,overload,overtemperature,andearthfault
DROPPERDIODES DropperDiodes
DropperDiodesareavailableuponrequestforfloatandboostvoltageregulation(OPTIONAL)
ConfidentialMaterial.PowerManagementInstrumentsreservesalltherights.theinformationcontainedhereinmaybepublished,orreproduced,inwholeorinpart,withouttheexpress,prior,writtenpermissionofthemanufacturer
BATTERYCHARGERTECHNICALSPECIFICATIONS
SAFETY&ENVIRONMENT CircuitBreakers OverVoltageProtection ElectricalInterferenceReduction ElectricalStandards ProtectionLevel/Color IsolationVoltage MTBF EnclosureMaterial PanelLighting Cooling CableEntry Dimensions OperatingTemperature Relativehumidity OperatingAltitude NoiseLevel CabinDimension
Input:Magneticcircuitbreakers;Output:Magneticcircuitbreakers;Battery:Magneticcircuitbreakers(SchneiderActi9) IEEE5874500A,110Joules(standard), FCCPart15ClassB EN500911(Security)/EN500912(EMC) IP42/RAL7035 2000VACinput/chassisandoutput/chassis 100,000hrs.(w/outbatterygroup) MildSteel,Zincphosphatecoated;100melectrostaticpaint;1.5mmthickness Option Forcedfans Bottom Rangeofoptionsavailableanddoeschangebasedoncustomizedconfiguration 10/+40C 590% Max.2000Mt. Max.60db (H)1500(W)600(D)800mm
*Pleaserefertobatterysizingandtechnicaldatasheetsforfurtherdetails **Pleaserefertobatterychargerusermanualforfurthertechnicaldetails
ConfidentialMaterial.PowerManagementInstrumentsreservesalltherights.theinformationcontainedhereinmaybepublished,orreproduced,inwholeorinpart,withouttheexpress,prior,writtenpermissionofthemanufacturer