Sunteți pe pagina 1din 40

! -----------------------------------------------------------------------!

Log file: /home/bcakra/script_new/npi/alarm/ZEOL_FBSC_SEKAYU_19September13-h07


.txt
! Starting MML commands execution in network element: FBSC_SEKAYU
! Date and time: 2013-09-19 07:15:46
! UNIX user group: 1006
! Commands are given by application.
! -----------------------------------------------------------------------ZZEOL;
LOADING PROGRAM VERSION 11.1-0
BTS ALARM LISTING
*

SEKAYU
BCF-0011
ALARM
(60904) 7622 CABINET OPEN

ENVIR

2013-05-09 14:36:13.72

Spec_Problem: 53277-RACK: door open Not_ID: 15


00 00 00 2B 00 00

SEKAYU
BCF-0011 BTS-0013
ENVIR
2013-05-09 14:36:14.72
ALARM
SEKAYU2MGC3
(60905) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -003
SEKAYU2MGC1
RTSL-004
(17912) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:13:00.27

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -003
SEKAYU2MGC1
RTSL-007
(15065) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-17 19:42:25.31

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -003
SEKAYU2MGC1
RTSL-002
(15067) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-17 19:42:30.93

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -003
SEKAYU2MGC1
RTSL-000
(15068) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-17 19:42:36.97

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-006
(17950) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:15:51.91

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-003
(17951) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:16:00.93

00
SEKAYU
BCF-0011 BTS-0012
EQUIPM
** ALARM TRX -008
SEKAYU2MGC2
RTSL-007
(17936) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:14:41.52

00
SEKAYU
BCF-0011 BTS-0012
EQUIPM
** ALARM TRX -008
SEKAYU2MGC2
RTSL-001
(17926) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:14:11.34

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-000
(17952) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:16:01.29

00
SEKAYU
BCF-0011 BTS-0013
PROCES
2013-08-03 18:45:31.72
** ALARM
SEKAYU2MGC3
(17144) 7737 INCONSISTENT DATA IN RADIO RESOURCE MANAGEMENT STATE FILES
1d 23d 26d 52d 0d 0d 14 157d 548d
SEKAYU
BCF-0011 BTS-0012
EQUIPM
** ALARM TRX -007
SEKAYU2MGC2
(44013) 7606 TRX FAULTY

2013-09-19 02:34:40.94

Spec_Problem: 34892-RF power reflected into powerstage


Not_ID: 2267550
00 00 04 2E 00 00
SEKAYU

BCF-0011 BTS-0011

EQUIPM

2013-05-29 23:16:04.75

** ALARM TRX -004


SEKAYU2MGC1
RTSL-001
(17955) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE
00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-004
(17956) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:16:05.45

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-002
(17957) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:16:06.26

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-005
(17958) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:16:11.37

00
SEKAYU
BCF-0011 BTS-0011
EQUIPM
** ALARM TRX -004
SEKAYU2MGC1
RTSL-007
(17959) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-05-29 23:16:11.49

00

SEKAYU
BCF-0021
ALARM
(41990) 7622 CABINET OPEN

ENVIR

2013-08-31 18:00:31.44

Spec_Problem: 53277-RACK: door open Not_ID: 7


00 00 00 2B 00 00

SEKAYU
BCF-0021 BTS-0021
ENVIR
2013-08-31 18:00:32.33
ALARM
SEKAYUMGC1
(41991) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0021 BTS-0023
ENVIR
2013-08-31 18:00:32.34
ALARM
SEKAYUMGC3
(41993) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0021 BTS-0022
ENVIR
2013-09-07 17:44:14.05
ALARM
SEKAYUMGC2
(50057) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0024
ALARM
(41986) 7622 CABINET OPEN

ENVIR

2013-08-31 18:00:08.35

Spec_Problem: 53277-RACK: door open Not_ID: 4


00 00 00 2B 00 00
SEKAYU
BCF-0024
*** ALARM
(15355) 7409 EXTERNAL AL 9
HIGH TEMP

ENVIR

2013-09-04 02:55:35.03

Not_ID: 70022

SEKAYU
BCF-0024 BTS-0024
ENVIR
2013-08-31 18:00:09.27
ALARM
SEKAYUMDC1
(41988) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N
SEKAYU

BCF-0041

COMM

2013-09-02 19:59:59.22

** ALARM
TRE -0255
(57914) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Spec_Problem: 10271-AIS alarm Not_ID: 3
02 7d 00 0d 0d TRE 0d 00 00 02
SEKAYU
BCF-0041
** ALARM
(58284) 7601 BCF OPERATION DEGRADED

COMM

2013-09-02 20:48:49.61

Spec_Problem: 10276-Slip alarm Not_ID: 1307


00 00 02 1F 00 00
SEKAYU
BCF-0041 BTS-0043
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -011
SEMANGUSMGC3
RTSL-002
(44162) 7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
01 120d 1d 7205d
SEKAYU
BCF-0041
*** ALARM
(44200) 7403 EXTERNAL AL 3
MAINS FAIL

ENVIR

2013-09-19 04:15:47.28

Not_ID: 164369

SEKAYU
BCF-0041 BTS-0042
ENVIR
2013-09-02 20:00:00.33
ALARM
SEMANGUSMGC2
(57916) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0041
*** ALARM
(57915) 7405 EXTERNAL AL 5
MODULE RECT FAIL

ENVIR

2013-09-02 19:59:59.25

Not_ID: 17

SEKAYU
BCF-0044 BTS-0044
ENVIR
2013-09-11 13:58:56.76
ALARM
SEMANGUSMDC1
(65523) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0044 BTS-0045
ENVIR
2013-09-11 13:40:57.12
ALARM
SEMANGUSMDC2
(65396) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0044 BTS-0046
QUAL
2013-09-18 16:11:24.27
** ALARM TRX -014
SEMANGUSMDC3
(42023) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 00 00 00 00 00 00 00 00 02 60d
SEKAYU
BCF-0044 BTS-0046
QUAL
2013-09-18 15:56:40.33
** ALARM TRX -014
SEMANGUSMDC3
(41981) 7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
00 01 01 01 01 01 01 01 01 02 2d
SEKAYU
BCF-0051
*** ALARM
(11090) 7409 EXTERNAL AL 9
HIGH FLOAT

ENVIR

2013-09-03 19:30:50.36

Not_ID: 7

SEKAYU
BCF-0051 BTS-0051
EQUIPM
** ALARM TRX -004
MAMBANGMGC1
(44017) 7606 TRX FAULTY

2013-09-19 02:35:03.52

Spec_Problem: 65535-No TRX-HW can be assigned Not_ID: 89


FF FF FF FF FF FF
SEKAYU

BCF-0051

ENVIR

2013-09-19 04:15:46.67

*** ALARM
(44198) 7403 EXTERNAL AL 3
MAINS FAIL

Not_ID: 119389

SEKAYU
BCF-0051 BTS-0052
QUAL
2013-09-12 08:09:04.06
** ALARM TRX -006
MAMBANGMGC2
(13966) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 01 00 06 02 35d
SEKAYU
BCF-0051
*** ALARM
(44199) 7405 EXTERNAL AL 5
MODULE RECT FAIL

ENVIR

2013-09-19 04:15:46.78

Not_ID: 119391

SEKAYU
BCF-0054 BTS-0055
ENVIR
2013-09-10 07:54:18.18
ALARM
MAMBANGMD2
(58724) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0054 BTS-0055
QUAL
2013-09-17 19:56:40.29
** ALARM TRX -005
MAMBANGMD2
(39192) 7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
00 00 00 01 01 00 00 00 03 00 1d
SEKAYU
BCF-0054 BTS-0055
QUAL
2013-09-18 08:11:04.09
** ALARM TRX -005
MAMBANGMD2
(40622) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 01 00 00 00 04 00 51d
SEKAYU
BCF-0054 BTS-0055
QUAL
2013-09-15 08:09:53.02
** ALARM TRX -011
MAMBANGMD2
(30091) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 01 00 00 05 01 59d
SEKAYU
BCF-0054 BTS-0055
QUAL
2013-09-18 08:11:04.09
** ALARM TRX -012
MAMBANGMD2
(40623) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 01 00 00 00 04 01 78d
SEKAYU
BCF-0054 BTS-0055
QUAL
2013-09-18 08:11:04.09
** ALARM TRX -008
MAMBANGMD2
(40624) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 00 00 00 00 03 00 54d

SEKAYU
BCF-0061 BTS-0062
ENVIR
2013-09-18 17:31:43.49
ALARM
1PTGUTHRIEMG2
(42318) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0061 BTS-0063
ENVIR
2013-09-18 17:31:43.49
ALARM
1PTGUTHRIEMG3
(42319) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0061
*** ALARM
(42320) 7401 EXTERNAL AL 1

ENVIR

2013-09-18 17:31:43.98

ENVIR

2013-09-18 17:31:44.03

ENVIR

2013-09-18 17:31:44.11

ENVIR

2013-09-18 17:31:44.14

ENVIR

2013-09-14 15:21:01.63

MAINS FAIL
SEKAYU
BCF-0061
*** ALARM
(42321) 7402 EXTERNAL AL 2
MODULE RECT FAIL
SEKAYU
BCF-0061
*** ALARM
(42323) 7404 EXTERNAL AL 4
GENSET RUNNING
SEKAYU
BCF-0061
*** ALARM
(42324) 7406 EXTERNAL AL 6
DOOR OPEN

SEKAYU
BCF-0081
ALARM
(28030) 7622 CABINET OPEN

Spec_Problem: 53277-RACK: door open Not_ID: 15


00 00 00 2B 00 00
SEKAYU
BCF-0081
** ALARM
(28031) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-14 15:21:01.66

Spec_Problem: 53278-FANP: unit failed Not_ID: 187


00 00 61 29 00 00

SEKAYU

BCF-0084

COMM

2013-09-14 15:20:23.65

*** ALARM
TRE -0255
(28023) 8050 LOSS OF INCOMING 2M SIGNAL
Spec_Problem: 10270-Loss of signal Not_ID: 97
02 7d 00 0d 0d TRE 0d 00 00 01
SEKAYU

BCF-0084

COMM

2013-09-14 15:20:23.68

*** ALARM
TRE -0255
(28024) 8050 LOSS OF INCOMING 2M SIGNAL
Spec_Problem: 10270-Loss of signal Not_ID: 99
02 7d 00 0d 0d TRE 0d 00 00 04

SEKAYU
BCF-0084 BTS-0085
ENVIR
2013-09-14 15:20:25.57
ALARM
SEKAYU3MDC2
(28025) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0084 BTS-0085
QUAL
2013-09-18 08:11:04.09
** ALARM TRX -014
SEKAYU3MDC2
(40626) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 01 01 00 00 00 00 00 02 01 66d
SEKAYU
BCF-0091
*** ALARM
(45455) 7403 EXTERNAL AL 3
MAINS FAIL
SEKAYU
BCF-0091
*** ALARM
(45457) 7405 EXTERNAL AL 5
MODULE RECT FAIL
SEKAYU

BCF-0091

ENVIR

2013-09-19 07:13:39.84

Not_ID: 247729
ENVIR

2013-09-19 07:13:39.95

Not_ID: 247732
COMM

2013-09-01 04:19:00.94

** ALARM
TRE -0255
(44267) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Spec_Problem: 10271-AIS alarm Not_ID: 4
02 7d 00 0d 0d TRE 0d 00 00 02
SEKAYU
BCF-0091
** ALARM
(44268) 7601 BCF OPERATION DEGRADED

COMM

2013-09-01 04:19:00.96

Spec_Problem: 10276-Slip alarm Not_ID: 59

00 00 02 1F 00 00
SEKAYU
BCF-0094 BTS-0094
EQUIPM
** ALARM TRX -008
MANGUNJAYAMDC1
(44021) 7606 TRX FAULTY

2013-09-19 02:35:26.77

Spec_Problem: 65535-No TRX-HW can be assigned Not_ID: 167


FF FF FF FF FF FF
SEKAYU
BCF-0094 BTS-0094
QUAL
2013-09-12 17:09:28.27
** ALARM TRX -003
MANGUNJAYAMDC1
(16653) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
02 01 00 00 00 00 00 00 00 00 00 100d
SEKAYU
BCF-0094 BTS-0095
EQUIPM
** ALARM TRX -012
MANGUNJAYAMDC2
(31033) 7606 TRX FAULTY

2013-09-06 20:22:11.55

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 357377
00 00 07 2E 00 00
SEKAYU
BCF-0094 BTS-0096
EQUIPM
** ALARM TRX -015
MANGUNJAYAMDC3
RTSL-002
(62296) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-08-19 20:24:57.68

00
SEKAYU
BCF-0094 BTS-0096
EQUIPM
** ALARM TRX -015
MANGUNJAYAMDC3
RTSL-007
(62210) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-08-19 20:24:30.69

00
SEKAYU
BCF-0094 BTS-0096
EQUIPM
** ALARM TRX -015
MANGUNJAYAMDC3
RTSL-005
(62264) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-08-19 20:24:47.14

00
SEKAYU
BCF-0094 BTS-0096
EQUIPM
** ALARM TRX -015
MANGUNJAYAMDC3
RTSL-001
(62267) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-08-19 20:24:47.82

00
SEKAYU

BCF-0094 BTS-0096

EQUIPM

2013-08-19 20:24:51.11

** ALARM TRX -015


MANGUNJAYAMDC3
RTSL-003
(62288) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE
00
SEKAYU
BCF-0094 BTS-0096
EQUIPM
** ALARM TRX -015
MANGUNJAYAMDC3
RTSL-004
(62295) 7725 TRAFFIC CHANNEL ACTIVATION FAILURE

2013-08-19 20:24:53.91

00
SEKAYU
BCF-0094 BTS-0094
EQUIPM
** ALARM TRX -003
MANGUNJAYAMDC1
(63919) 7606 TRX FAULTY

2013-09-11 07:35:54.13

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 433483
00 00 00 2E 00 00
SEKAYU
BCF-0094
*** ALARM
(52076) 7406 EXTERNAL AL 6
BATTS STOLENE
SEKAYU
BCF-0094
*** ALARM
(52077) 7407 EXTERNAL AL 7
LOW LOAD

2013-08-18 10:43:47.97

Not_ID: 23
ENVIR

2013-08-18 10:43:47.98

Not_ID: 26

SEKAYU
BCF-0094
*** ALARM
(52079) 7408 EXTERNAL AL 8
MDUL RECT FAIL
SEKAYU
BCF-0094
*** ALARM
(52080) 7409 EXTERNAL AL 9
MAINS FAIL
SEKAYU

ENVIR

BCF-0094

ENVIR

2013-08-18 10:43:48.00

Not_ID: 28
ENVIR

2013-08-18 10:43:48.04

Not_ID: 30
COMM

2013-08-19 20:56:58.78

*** ALARM
TRE -0255
(63532) 8081 LOSS OF FRAME ALIGNMENT
Spec_Problem: 10273-Loss of Frame Alignment Not_ID: 29034
02 7d 00 0d 0d TRE 0d 00 00 02

SEKAYU

BCF-0094

COMM

2013-08-19 21:07:38.09

** ALARM
TRE -0255
(64420) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Spec_Problem: 10271-AIS alarm Not_ID: 29584
02 7d 00 0d 0d TRE 0d 00 00 02
SEKAYU

BCF-0094

COMM

2013-08-19 20:28:02.33

** ALARM
TRE -0255
(62660) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Spec_Problem: 10271-AIS alarm Not_ID: 27617
02 7d 00 0d 0d TRE 0d 00 00 00
SEKAYU
BCF-0094 BTS-0094
QUAL
2013-09-13 08:09:28.42
** ALARM TRX -003
MANGUNJAYAMDC1
(20671) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 01 01 01 01 01 01 01 00 100d
SEKAYU
BCF-0094 BTS-0094
QUAL
2013-09-18 17:11:28.30
** ALARM TRX -006
MANGUNJAYAMDC1
(42230) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 00 01 00 00 01 00 01 00 43d
SEKAYU
BCF-0094 BTS-0094
COMM
2013-09-11 10:17:57.55
*** ALARM TRX -003
MANGUNJAYAMDC1
(64660) 7723 FAILURE IN SENDING SYSTEM INFORMATION TO BTS SITE
0C 14396d
SEKAYU
BCF-0094 BTS-0094
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -007
MANGUNJAYAMDC1
(44163) 7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
00 00 01 00 00 00 00 00 02 00 2d

SEKAYU
BCF-0094 BTS-0094
ENVIR
2013-09-12 17:40:13.97
ALARM
MANGUNJAYAMDC1
(16905) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0094 BTS-0094
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -004
MANGUNJAYAMDC1
(44164) 7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
00 00 01 00 00 00 00 00 02 01 2d

SEKAYU
BCF-0101 BTS-0103
EQUIPM
** ALARM TRX -012
SUNGAIANGITMGC3
(45221) 7606 TRX FAULTY

2013-09-19 05:38:30.35

Spec_Problem: 65535-No TRX-HW can be assigned Not_ID: 172


FF FF FF FF FF FF

SEKAYU
BCF-0101 BTS-0102
QUAL
ALARM TRX -005
SUNGAIANGITMGC2
(45222) 7208 LOCAL BLOCK

2013-09-19 05:38:30.37

00 00 07 2E 00 00
SEKAYU
BCF-0101 BTS-0102
EQUIPM
** ALARM TRX -006
SUNGAIANGITMGC2
(45231) 7606 TRX FAULTY

2013-09-19 05:39:22.77

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 246


00 00 03 23 00 01
SEKAYU
BCF-0101 BTS-0102
EQUIPM
** ALARM TRX -007
SUNGAIANGITMGC2
(45232) 7607 TRX OPERATION DEGRADED

2013-09-19 05:39:22.80

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 246


00 00 03 23 00 01
SEKAYU
BCF-0101 BTS-0102
EQUIPM
** ALARM TRX -008
SUNGAIANGITMGC2
(45233) 7607 TRX OPERATION DEGRADED

2013-09-19 05:39:22.82

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 246


00 00 03 23 00 01

SEKAYU
BCF-0104 BTS-0104
ENVIR
2013-09-18 21:13:43.41
ALARM
SUNGAIANGITMD1
(43287) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0104 BTS-0105
ENVIR
2013-09-18 21:13:43.41
ALARM
SUNGAIANGITMD2
(43288) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0104 BTS-0106
ENVIR
2013-09-18 21:13:43.41
ALARM
SUNGAIANGITMD3
(43289) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0104
ALARM
(43378) 7602 BCF NOTIFICATION

EQUIPM

2013-09-18 21:27:52.93

ESMx System module cooling fan speed has increased from the
set speed
00 00 00 82 00 00
SEKAYU

BCF-0104

PROCES

2013-09-18 21:23:54.64

** ALARM
RM -0011
(43365) 7607 TRX OPERATION DEGRADED
RF module filter tuning failed
00 00 00 83 11 11 2d 3d 4d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d
SEKAYU
BCF-0104 BTS-0104
PROCES
** ALARM
SUNGAIANGITMD1
(43366) 7604 BTS OPERATION DEGRADED

2013-09-18 21:23:54.67

RF module filter tuning failed


00 00 00 83 11 11
SEKAYU

BCF-0104

PROCES

2013-09-18 21:24:00.88

** ALARM
RM -0011
(43367) 7607 TRX OPERATION DEGRADED
RF module filter tuning failed
00 00 00 83 11 22 6d 7d 8d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d
SEKAYU
BCF-0104 BTS-0105
PROCES
** ALARM
SUNGAIANGITMD2
(43368) 7604 BTS OPERATION DEGRADED

2013-09-18 21:24:00.97

RF module filter tuning failed


00 00 00 83 11 22
SEKAYU

BCF-0104

PROCES

2013-09-18 21:24:03.98

** ALARM
RM -0011
(43369) 7607 TRX OPERATION DEGRADED
RF module filter tuning failed
00 00 00 83 11 32 10d 11d 12d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d

SEKAYU
BCF-0104 BTS-0106
PROCES
** ALARM
SUNGAIANGITMD3
(43370) 7604 BTS OPERATION DEGRADED
RF module filter tuning failed
00 00 00 83 11 32

2013-09-18 21:24:04.01

SEKAYU
*

BCF-0104

QUAL

2013-09-19 04:53:05.49

QUAL

2013-09-19 04:47:00.07

ENVIR

2013-09-18 14:12:29.30

ALARM
TRE -0001
(44524) 7740 BEATING BTS ALARM
8112 02 F0 0F 00 02
SEKAYU

BCF-0104

ALARM
TRE -0001
(44392) 7740 BEATING BTS ALARM
8066 02 F0 0F 01 09

SEKAYU
BCF-0111
ALARM
(41768) 7622 CABINET OPEN

Spec_Problem: 53277-RACK: door open Not_ID: 17


00 00 00 2B 00 00
SEKAYU
BCF-0111
** ALARM
(41769) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-18 14:12:29.33

Spec_Problem: 53278-FANP: unit failed Not_ID: 204


00 00 60 29 00 00
SEKAYU
BCF-0111
** ALARM
(41770) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-18 14:12:29.35

Spec_Problem: 53278-FANP: unit failed Not_ID: 206


00 00 61 29 00 00
SEKAYU
BCF-0111
** ALARM
(41771) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-18 14:12:29.37

Spec_Problem: 53278-FANP: unit failed Not_ID: 208


00 00 63 29 00 00
SEKAYU
BCF-0111
** ALARM
(41772) 7403 EXTERNAL AL 3
MAINFAIL
SEKAYU
BCF-0111
** ALARM
(41773) 7405 EXTERNAL AL 5

ENVIR

2013-09-18 14:12:29.39

Not_ID: 25
ENVIR

2013-09-18 14:12:29.41

RECTY FAIL
SEKAYU
BCF-0111
** ALARM
(41774) 7408 EXTERNAL AL 8
LOWLOAD

Not_ID: 28
ENVIR

2013-09-18 14:12:29.43

Not_ID: 30

SEKAYU
BCF-0111
** ALARM
(41775) 7409 EXTERNAL AL 9
BATTSTOLEN

ENVIR

2013-09-18 14:12:29.45

Not_ID: 32

SEKAYU
BCF-0111 BTS-0113
EQUIPM
** ALARM TRX -011
KTPATBENINGMGC3
(44030) 7606 TRX FAULTY

2013-09-19 02:37:21.59

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 333
00 00 08 2E 00 00
SEKAYU
BCF-0111 BTS-0113
EQUIPM
** ALARM TRX -010
KTPATBENINGMGC3
(41777) 7607 TRX OPERATION DEGRADED

2013-09-18 14:12:29.51

Spec_Problem: 53430-LNA: RX alarm LOW Not_ID: 49


00 00 03 23 00 00
SEKAYU
BCF-0111 BTS-0113
QUAL
2013-09-18 17:11:28.30
** ALARM TRX -010
KTPATBENINGMGC3
(42234) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 00 00 00 00 00 00 01 00 31d
SEKAYU
BCF-0111 BTS-0113
EQUIPM
** ALARM
KTPATBENINGMGC3
(41779) 7604 BTS OPERATION DEGRADED

2013-09-18 14:12:29.56

Spec_Problem: 53430-LNA: RX alarm LOW Not_ID: 49


00 00 03 23 00 00
SEKAYU
BCF-0111 BTS-0113
EQUIPM
** ALARM TRX -012
KTPATBENINGMGC3
(42863) 7607 TRX OPERATION DEGRADED

2013-09-18 19:45:52.91

Spec_Problem: 53430-LNA: RX alarm LOW Not_ID: 49


00 00 03 23 00 00
SEKAYU
*

ALARM

BCF-0114 BTS-0114
ENVIR
1KTPBENINGMD1

2013-09-18 16:58:15.41

(42195) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD


N

SEKAYU
BCF-0114 BTS-0115
ENVIR
2013-09-18 16:58:30.73
ALARM
1KTPBENINGMD2
(42198) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0121
** ALARM
(60739) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-10 17:09:33.88

Spec_Problem: 53278-FANP: unit failed Not_ID: 153


00 00 62 29 00 00
SEKAYU
BCF-0121
** ALARM
(60740) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-10 17:09:33.90

Spec_Problem: 53278-FANP: unit failed Not_ID: 155


00 00 63 29 00 00
SEKAYU
BCF-0121 BTS-0123
EQUIPM
** ALARM TRX -009
RIMBAUKURMGC3
(44033) 7606 TRX FAULTY

2013-09-19 02:37:44.38

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 226
00 00 08 2E 00 00
SEKAYU
BCF-0121 BTS-0121
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -003
RIMBAUKURMGC1
RTSL-002
(44165) 7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
00 122d 1d 7342d
SEKAYU
BCF-0121 BTS-0121
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -003
RIMBAUKURMGC1
RTSL-006
(44166) 7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
01 122d 1d 7366d
SEKAYU
BCF-0134
*** ALARM
(44265) 7407 EXTERNAL AL 7
RECTIFIER TRANS PLN OFF

ENVIR

Not_ID: 19

2013-09-07 02:40:15.16

SEKAYU
BCF-0134 BTS-0134
QUAL
2013-09-17 08:10:43.75
** ALARM TRX -007
SEKAYU2MDC1
(37816) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 00 01 07 02 31d
SEKAYU
BCF-0134 BTS-0134
QUAL
2013-09-17 08:10:43.75
** ALARM TRX -004
SEKAYU2MDC1
(37818) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 00 00 01 01 06 02 40d

SEKAYU
BCF-0134 BTS-0134
ENVIR
2013-09-07 02:44:02.59
ALARM
SEKAYU2MDC1
(44442) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0134 BTS-0136
ENVIR
2013-09-07 02:42:23.54
ALARM
SEKAYU2MDC3
(44367) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0141
ALARM
(39510) 7622 CABINET OPEN

ENVIR

2013-09-17 22:09:33.69

Spec_Problem: 53277-RACK: door open Not_ID: 16


00 00 00 2B 00 00

SEKAYU
BCF-0141 BTS-0142
QUAL
ALARM TRX -007
BABATTOMANMGC2
(39511) 7208 LOCAL BLOCK

2013-09-17 22:09:33.71

00 00 0B 2E 00 00

SEKAYU
BCF-0141 BTS-0143
QUAL
ALARM TRX -011
BABATTOMANMGC3
(39512) 7208 LOCAL BLOCK

2013-09-17 22:09:33.73

00 00 09 2E 00 00

SEKAYU
BCF-0141 BTS-0141
ENVIR
2013-09-17 22:09:34.26
ALARM
BABATTOMANMGC1
(39513) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0141 BTS-0142
PROCES
** ALARM TRX -008
BABATTOMANMGC2
(39520) 7730 CONFIGURATION OF BCF FAILED

2013-09-17 22:10:20.41

16368d
SEKAYU
BCF-0141 BTS-0142
QUAL
** ALARM
BABATTOMANMGC2
(39540) 7734 BCCH IS NOT AT PREFERRED BCCH TRX

2013-09-17 22:11:21.99

SEKAYU
BCF-0141 BTS-0143
PROCES
** ALARM TRX -012
BABATTOMANMGC3
(39546) 7730 CONFIGURATION OF BCF FAILED

2013-09-17 22:11:56.75

16368d
SEKAYU
BCF-0141 BTS-0143
QUAL
** ALARM
BABATTOMANMGC3
(39558) 7734 BCCH IS NOT AT PREFERRED BCCH TRX

2013-09-17 22:12:57.59

SEKAYU
BCF-0144 BTS-0146
ENVIR
2013-09-17 22:10:30.92
ALARM
BABATTOMANMDC3
(39527) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0144 BTS-0145
EQUIPM
** ALARM TRX -008
BABATTOMANMDC2
(44037) 7606 TRX FAULTY

2013-09-19 02:38:07.93

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 2874
01 00 00 2E 00 00

SEKAYU
BCF-0144 BTS-0146
QUAL
ALARM TRX -017
BABATTOMANMDC3
(39509) 7208 LOCAL BLOCK

2013-09-17 22:09:20.18

00 00 06 2E 00 00

SEKAYU
BCF-0144
ALARM
(45443) 7404 EXTERNAL AL 4
GENSET RUNNING

SEKAYU
BCF-0151
** ALARM
(30702) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-19 07:13:03.17

Not_ID: 432840
ENVIR

2013-07-12 06:56:49.92

Spec_Problem: 53278-FANP: unit failed Not_ID: 181


00 00 60 29 00 00

SEKAYU
BCF-0151
ALARM
(30703) 7404 EXTERNAL AL 4
BATT STOLEN

SEKAYU
BCF-0151
ALARM
(30704) 7406 EXTERNAL AL 6
BATT STOLEN

ENVIR

2013-07-12 06:56:49.94

Not_ID: 18
ENVIR

2013-07-12 06:56:49.96

Not_ID: 21

SEKAYU
BCF-0151 BTS-0153
EQUIPM
** ALARM TRX -011
SUNGAIKERUHMGC3
(44040) 7606 TRX FAULTY

2013-09-19 02:38:30.80

Spec_Problem: 28675-Test Result failed Not_ID: 338660


01 00 02 2E 00 00
SEKAYU
BCF-0151 BTS-0151
QUAL
2013-09-17 08:10:43.75
** ALARM TRX -004
SUNGAIKERUHMGC1
(37819) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 00 01 07 01 60d
SEKAYU
BCF-0161 BTS-0161
EQUIPM
** ALARM TRX -003
SEKATOMMGC1
(44044) 7606 TRX FAULTY

2013-09-19 02:38:53.51

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 183753
00 00 00 2E 00 00
SEKAYU
BCF-0161
*** ALARM
(15618) 7403 EXTERNAL AL 3
MAINS FAIL
SEKAYU
BCF-0161
** ALARM
(15619) 7404 EXTERNAL AL 4
BATT STOLEN
SEKAYU
BCF-0161
*** ALARM
(15620) 7405 EXTERNAL AL 5
MODULE RECT FAIL

ENVIR

2013-08-20 12:43:05.00

Not_ID: 15
ENVIR

2013-08-20 12:43:05.01

Not_ID: 18
ENVIR

Not_ID: 20

2013-08-20 12:43:05.03

SEKAYU
BCF-0161
*** ALARM
(15621) 7408 EXTERNAL AL 8

ENVIR

2013-08-20 12:43:05.05

LOW BATT / LOAD FUSE FAIL Not_ID: 22


SEKAYU
BCF-0161
*** ALARM
(15622) 7409 EXTERNAL AL 9
HIGH FLOAT

SEKAYU
BCF-0161
ALARM
(15623) 7622 CABINET OPEN

ENVIR

2013-08-20 12:43:05.09

Not_ID: 24
ENVIR

2013-08-20 12:43:05.12

Spec_Problem: 53277-RACK: door open Not_ID: 64


01 00 00 2B 00 00
SEKAYU
BCF-0161 BTS-0161
EQUIPM
** ALARM TRX -004
SEKATOMMGC1
(42898) 7606 TRX FAULTY

2013-09-18 19:55:48.58

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 185675
00 00 03 2E 00 00
SEKAYU
BCF-0161 BTS-0162
EQUIPM
** ALARM TRX -008
SEKATOMMGC2
(42185) 7606 TRX FAULTY

2013-09-18 16:53:22.68

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 184071
00 00 06 2E 00 00
SEKAYU
BCF-0164 BTS-0166
EQUIPM
** ALARM TRX -012
SEKATOMMDC3
(44049) 7606 TRX FAULTY

2013-09-19 02:40:02.56

Spec_Problem: 20488-Unsuccessful board recovery Not_ID: 110988


01 00 00 2E 00 00
SEKAYU
BCF-0164 BTS-0165
EQUIPM
** ALARM TRX -007
SEKATOMMDC2
(42157) 7606 TRX FAULTY

2013-09-18 16:42:59.06

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 107319
00 00 04 2E 00 00
SEKAYU
BCF-0171
** ALARM
(35573) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-16 15:02:08.30

Spec_Problem: 53278-FANP: unit failed Not_ID: 192


00 00 63 29 00 00

SEKAYU
BCF-0171 BTS-0171
ENVIR
2013-09-16 15:02:09.13
ALARM
MUARALAKITNMGC1
(35575) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0171 BTS-0172
QUAL
2013-09-18 08:11:06.10
** ALARM TRX -007
MUARALAKITNMGC2
(40630) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 00 00 00 00 03 01 38d
SEKAYU
BCF-0171 BTS-0173
QUAL
2013-09-18 08:11:06.10
** ALARM TRX -011
MUARALAKITNMGC3
(40631) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 01 01 01 01 03 02 69d

SEKAYU
BCF-0171
ALARM
(35574) 7404 EXTERNAL AL 4
BATT STOLEN

ENVIR

2013-09-16 15:02:08.32

Not_ID: 17

SEKAYU
BCF-0174 BTS-0174
ENVIR
2013-09-16 15:05:46.51
ALARM
MUARALAKITNMDC1
(35584) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0174
ALARM
(35569) 7622 CABINET OPEN

ENVIR

2013-09-16 15:01:45.70

Spec_Problem: 53277-RACK: door open Not_ID: 16


00 00 00 2B 00 00

SEKAYU
BCF-0174
ALARM
(42349) 7404 EXTERNAL AL 4
GENSET RUNNING

ENVIR

2013-09-18 17:44:59.88

Not_ID: 18044

SEKAYU
BCF-0174 BTS-0176
ENVIR
2013-09-16 15:01:46.60
ALARM
MUARALAKITNMDC3
(35572) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0181
*** ALARM
(15720) 7403 EXTERNAL AL 3

ENVIR

2013-08-20 13:05:14.56

LOW BATT
SEKAYU
BCF-0181 BTS-0182
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -007
2SUKARAMSKYMG2
RTSL-004
(44167) 7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
01 120d 1d 7218d
SEKAYU
BCF-0181
*** ALARM
(15721) 7404 EXTERNAL AL 4

ENVIR

2013-08-20 13:05:14.62

ENVIR

2013-08-20 13:05:14.72

ENVIR

2013-09-18 17:26:13.13

BATTERY STOLEN
SEKAYU
BCF-0181
*** ALARM
(15722) 7405 EXTERNAL AL 5
HIGH LOAD
SEKAYU
BCF-0191
*** ALARM
(42299) 7403 EXTERNAL AL 3
MAINS FAILED

Not_ID: 19531

SEKAYU
BCF-0191 BTS-0191
QUAL
2013-09-15 16:10:17.22
** ALARM TRX -001
ULAKPACEHMGC1
(31456) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 01 01 00 00 05 01 53d
SEKAYU
BCF-0191 BTS-0192
QUAL
2013-09-18 08:11:08.11
** ALARM TRX -005
ULAKPACEHMGC2
(40632) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 01 00 06 02 30d
SEKAYU
BCF-0191
*** ALARM
(42300) 7405 EXTERNAL AL 5
MODULE RECTIFIER FAILED
SEKAYU

BCF-0194 BTS-0194

ENVIR

2013-09-18 17:26:15.10

Not_ID: 19534
ENVIR

2013-09-15 20:02:28.95

ALARM
ULAKPACEHMDC1
(32332) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0194 BTS-0195
ENVIR
2013-09-15 20:02:28.95
ALARM
ULAKPACEHMDC2
(32333) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0201 BTS-0201
ENVIR
2013-09-10 16:42:20.55
ALARM
SPINANGLKNMGC1
(60575) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0201 BTS-0202
ENVIR
2013-09-10 16:38:14.18
ALARM
SPINANGLKNMGC2
(60554) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0201 BTS-0203
ENVIR
2013-09-10 16:38:14.19
ALARM
SPINANGLKNMGC3
(60555) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0201
*** ALARM
(35026) 7405 EXTERNAL AL 5
MODULE RECT FAIL

SEKAYU
BCF-0204
ALARM
(60561) 7406 EXTERNAL AL 6
BATT STOLEN

ENVIR

2013-09-16 11:38:52.71

Not_ID: 39197
ENVIR

2013-09-10 16:39:04.82

Not_ID: 20

SEKAYU
BCF-0204 BTS-0204
EQUIPM
** ALARM TRX -003
SPINANGLKNMDC1
(44052) 7606 TRX FAULTY

2013-09-19 02:40:48.82

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 506
00 00 00 2E 00 00
SEKAYU
BCF-0204 BTS-0206
QUAL
2013-09-18 15:11:22.25
** ALARM TRX -017
SPINANGLKNMDC3
(41888) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD

01 00 00 00 00 00 00 01 00 06 00 59d
SEKAYU
BCF-0204 BTS-0206
QUAL
2013-09-18 16:11:24.27
** ALARM TRX -016
SPINANGLKNMDC3
(42027) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 01 01 07 00 92d
SEKAYU
BCF-0204 BTS-0206
QUAL
2013-09-18 08:11:08.11
** ALARM TRX -015
SPINANGLKNMDC3
(40636) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 00 01 00 00 00 00 00 02 00 60d

SEKAYU
BCF-0204 BTS-0205
ENVIR
2013-09-10 16:39:05.96
ALARM
SPINANGLKNMDC2
(60563) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0204 BTS-0204
EQUIPM
** ALARM TRX -004
SPINANGLKNMDC1
(39536) 7606 TRX FAULTY

2013-09-17 22:11:12.75

Spec_Problem: 34835-The RF part of the CU has problems


Not_ID: 564
00 00 02 2E 00 00

SEKAYU
BCF-0211 BTS-0211
ENVIR
2013-09-14 18:26:36.88
ALARM
SPRANDIKSKYMGC1
(28641) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0211 BTS-0212
EQUIPM
** ALARM TRX -008
SPRANDIKSKYMGC2
(44056) 7606 TRX FAULTY

2013-09-19 02:41:34.57

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 4518


00 00 03 23 00 01
SEKAYU
BCF-0211 BTS-0212
COMM
2013-09-15 09:47:24.74
*** ALARM TRX -007
SPRANDIKSKYMGC2
(30295) 7723 FAILURE IN SENDING SYSTEM INFORMATION TO BTS SITE
0C 14396d
SEKAYU
BCF-0211 BTS-0212
EQUIPM
** ALARM TRX -005
SPRANDIKSKYMGC2
(30200) 7607 TRX OPERATION DEGRADED

2013-09-15 09:06:25.85

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 4518


00 00 03 23 00 01
SEKAYU
BCF-0211 BTS-0212
EQUIPM
** ALARM TRX -007
SPRANDIKSKYMGC2
(30201) 7606 TRX FAULTY

2013-09-15 09:06:25.88

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 4518


00 00 03 23 00 01
SEKAYU
BCF-0211 BTS-0212
EQUIPM
** ALARM
SPRANDIKSKYMGC2
(30204) 7604 BTS OPERATION DEGRADED

2013-09-15 09:06:47.17

Spec_Problem: 53428-VSWR alarm HIGH Not_ID: 4518


00 00 03 23 00 01
SEKAYU
BCF-0211 BTS-0212
QUAL
2013-09-16 08:10:23.41
** ALARM TRX -007
SPRANDIKSKYMGC2
(34605) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 01 01 01 01 01 01 01 00 00 100d

SEKAYU
BCF-0214 BTS-0215
ENVIR
2013-09-14 18:26:56.72
ALARM
SPRANDIKSKYMDC2
(28644) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0214 BTS-0216
QUAL
2013-09-18 14:11:20.23
** ALARM TRX -015
SPRANDIKSKYMDC3
(41762) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 00 00 00 00 00 00 00 00 00 70d
SEKAYU
BCF-0214 BTS-0216
QUAL
2013-09-19 03:56:40.36
** ALARM TRX -015
SPRANDIKSKYMDC3
(44168) 7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
00 00 00 00 01 00 00 01 04 02 2d
SEKAYU
BCF-0214 BTS-0214
PROCES
2013-09-18 19:58:27.75
** ALARM
SPRANDIKSKYMDC1
(42913) 7737 INCONSISTENT DATA IN RADIO RESOURCE MANAGEMENT STATE FILES
1d 23d 10d 20d 0d 0d 06 155d 586d
SEKAYU
BCF-0221 BTS-0221
QUAL
2013-09-12 08:09:08.08
** ALARM TRX -003
SEREKAMGC1
(13978) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 01 00 00 05 02 30d

SEKAYU
BCF-0221 BTS-0222
ENVIR
2013-09-05 14:03:52.21
ALARM
SEREKAMGC2
(24943) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0221 BTS-0223
EQUIPM
** ALARM TRX -011
SEREKAMGC3
(44061) 7606 TRX FAULTY

2013-09-19 02:42:20.52

Spec_Problem: 65535-No TRX-HW can be assigned Not_ID: 118682


FF FF FF FF FF FF
SEKAYU
BCF-0221
*** ALARM
(45456) 7404 EXTERNAL AL 4
MAINS FAIL
SEKAYU
BCF-0231
** ALARM
(64233) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-19 07:13:39.93

Not_ID: 134979
ENVIR

2013-09-11 08:37:50.83

Spec_Problem: 53278-FANP: unit failed Not_ID: 416020


00 00 61 29 00 00

SEKAYU
BCF-0231 BTS-0232
ENVIR
2013-07-11 09:28:54.67
ALARM
BTANGHARILKMGC2
(23954) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0241
*** ALARM
(60867) 7404 EXTERNAL AL 4
BATT STOLEN

ENVIR

2013-09-10 17:45:34.26

Not_ID: 38217

SEKAYU
BCF-0241 BTS-0241
ENVIR
2013-09-05 17:45:40.02
ALARM
RANDIKSKAYUMGC1
(25928) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0241 BTS-0242
EQUIPM
** ALARM TRX -005
RANDIKSKAYUMGC2
(42686) 7607 TRX OPERATION DEGRADED

2013-09-18 18:56:55.94

Spec_Problem: 34837-diversity receive branch failed Not_ID:


105407
00 00 05 2E 00 00

SEKAYU
BCF-0241 BTS-0243
ENVIR
2013-09-05 17:45:40.02
ALARM
RANDIKSKAYUMGC3
(25930) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0241 BTS-0243
PROCES
2013-09-05 20:08:54.78
** ALARM
RANDIKSKAYUMGC3
(26656) 7737 INCONSISTENT DATA IN RADIO RESOURCE MANAGEMENT STATE FILES
1d 15d 23d 46d 0d 0d 06 157d 574d
SEKAYU
BCF-0241 BTS-0241
QUAL
2013-09-10 11:56:39.85
** ALARM TRX -002
RANDIKSKAYUMGC1
RTSL-007
(59262) 7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
02 241d 1d 241d

SEKAYU
BCF-0244 BTS-0244
ENVIR
2013-09-05 17:43:51.22
ALARM
N2RANDIKSKYUMD1
(25911) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0244 BTS-0245
ENVIR
2013-09-05 17:43:51.22
ALARM
N2RANDIKSKYUMD2
(25912) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0251 BTS-0252
QUAL
2013-09-18 08:11:10.12
** ALARM TRX -007
1SUKALALIMG2
(40640) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 00 01 00 00 03 02 42d
SEKAYU
BCF-0251 BTS-0252
QUAL
2013-09-18 08:11:10.12
** ALARM TRX -005
1SUKALALIMG2
(40638) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 00 01 00 01 03 02 42d
SEKAYU
BCF-0251 BTS-0252
QUAL
2013-09-18 08:11:10.12
** ALARM TRX -008
1SUKALALIMG2
(40639) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 01 01 00 01 01 00 05 02 44d
SEKAYU

BCF-0261

ENVIR

2013-09-19 07:13:46.94

*** ALARM
(45460) 7401 EXTERNAL AL 1
MAINS FAIL
SEKAYU
BCF-0271 BTS-0273
QUAL
2013-09-18 09:11:14.15
** ALARM TRX -010
BANGUNSARIMGC3
(40762) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 00 00 00 00 01 00 00 05 01 42d
SEKAYU
BCF-0271 BTS-0273
QUAL
2013-09-18 14:11:20.23
** ALARM TRX -011
BANGUNSARIMGC3
(41763) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 01 00 00 05 01 50d
SEKAYU
BCF-0271 BTS-0273
QUAL
2013-09-18 17:11:28.30
** ALARM TRX -012
BANGUNSARIMGC3
(42235) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 01 00 00 00 04 00 40d

SEKAYU
BCF-0281
ALARM
(45299) 7622 CABINET OPEN

ENVIR

2013-09-19 06:13:07.68

Spec_Problem: 53277-RACK: door open Not_ID: 20


01 00 00 2B 00 00
SEKAYU

BCF-0281

COMM

2013-09-19 06:13:07.71

** ALARM
TRE -0255
(45300) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Spec_Problem: 10271-AIS alarm Not_ID: 55
02 7d 00 0d 0d TRE 0d 00 00 02
SEKAYU
BCF-0281
** ALARM
(45302) 7601 BCF OPERATION DEGRADED

COMM

2013-09-19 06:13:43.43

Spec_Problem: 10276-Slip alarm Not_ID: 209


00 00 02 1F 00 00
SEKAYU
BCF-0291
** ALARM
(64587) 7601 BCF OPERATION DEGRADED

ENVIR

2013-09-11 10:02:25.75

Spec_Problem: 53278-FANP: unit failed Not_ID: 154


00 00 60 29 00 00

SEKAYU
BCF-0301 BTS-0302
ENVIR
2013-09-18 03:31:21.63
ALARM
DESAPAUHMG2
(40106) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0301 BTS-0304
ENVIR
2013-09-18 03:31:21.63
ALARM
DESAPAUHMD1
(40107) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0301 BTS-0305
ENVIR
2013-09-18 03:31:21.63
ALARM
DESAPAUHMD2
(40108) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0301
*** ALARM
(45348) 7401 EXTERNAL AL 1

ENVIR

2013-09-19 06:46:21.89

ENVIR

2013-09-19 06:46:22.00

MAINS FAIL
SEKAYU
BCF-0301
*** ALARM
(45349) 7402 EXTERNAL AL 2
MODULE RECT FAIL
SEKAYU
BCF-0301 BTS-0302
EQUIPM
** ALARM TRX -006
DESAPAUHMG2
(40812) 7607 TRX OPERATION DEGRADED

2013-09-18 09:31:20.56

RSSI detected Rx signal difference exceeding threshold


0B 04 00 82 00 00
SEKAYU
BCF-0301 BTS-0302
EQUIPM
** ALARM TRX -007
DESAPAUHMG2
(40813) 7607 TRX OPERATION DEGRADED

2013-09-18 09:31:20.72

RSSI detected Rx signal difference exceeding threshold


0B 04 00 82 00 00
SEKAYU
BCF-0301 BTS-0302
EQUIPM
** ALARM TRX -008
DESAPAUHMG2
(41816) 7607 TRX OPERATION DEGRADED

2013-09-18 14:31:21.38

RSSI detected Rx signal difference exceeding threshold


0C 04 00 82 00 00
SEKAYU

BCF-0311 BTS-0314

ENVIR

2013-09-09 23:29:40.97

ALARM
SCONOCOPHILPMD1
(57983) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0321 BTS-0322
ENVIR
2013-09-09 22:36:59.63
ALARM
SANGADESAMG2
(57730) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0321 BTS-0324
ENVIR
2013-08-19 21:46:45.60
ALARM
SANGADESAMD1
(11520) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0321 BTS-0326
ENVIR
2013-09-17 22:12:34.51
ALARM
SANGADESAMD3
(39556) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N
SEKAYU
BCF-0321 BTS-0326
COMM
ALARM TRX -026
SANGADESAMD3
LAPD-0640
(39554) 7705 D-CHANNEL FAILURE

2013-09-17 22:12:34.51

SEKAYU
BCF-0321 BTS-0326
COMM
ALARM TRX -027
SANGADESAMD3
LAPD-0641
(39555) 7705 D-CHANNEL FAILURE

2013-09-17 22:12:34.51

SEKAYU
*

BCF-0321

QUAL

2013-08-31 14:10:04.04

ENVIR

2013-09-19 07:13:45.35

ALARM
TRE -0001
(39537) 7740 BEATING BTS ALARM
8102 02 F0 0F 01 0C

SEKAYU
BCF-0331
*** ALARM
(45458) 7401 EXTERNAL AL 1
MAINS FAIL

SEKAYU
BCF-0331 BTS-0334
ENVIR
2013-09-07 04:17:14.39
ALARM
KEMANGMD1
(47948) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD

N
SEKAYU
BCF-0331 BTS-0332
** ALARM TRX -008
KEMANGMG2
(38213) 7607 TRX OPERATION DEGRADED

EQUIPM

2013-09-17 11:17:41.38

RSSI detected Rx signal difference exceeding threshold


0B 04 00 82 00 00
SEKAYU
BCF-0331 BTS-0332
** ALARM TRX -007
KEMANGMG2
(29359) 7607 TRX OPERATION DEGRADED

EQUIPM

2013-09-14 23:17:34.95

RSSI detected Rx signal difference exceeding threshold


0B 04 00 82 00 00
SEKAYU
BCF-0331
*** ALARM
(45459) 7402 EXTERNAL AL 2

ENVIR

2013-09-19 07:13:45.48

MODULE RECT FAIL


SEKAYU
BCF-0331 BTS-0332
** ALARM TRX -005
KEMANGMG2
(36935) 7607 TRX OPERATION DEGRADED

EQUIPM

2013-09-17 00:17:40.47

RSSI detected Rx signal difference exceeding threshold


0B 04 00 82 00 00
SEKAYU
BCF-0331
*** ALARM
(47947) 7404 EXTERNAL AL 4

ENVIR

2013-09-07 04:17:12.24

COMM

2013-09-12 05:59:29.08

BATTERY STOLEN
SEKAYU

BCF-0341

** ALARM
TRE -0001
(13676) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Flexi Multiradio BTS 2G Flexi FIQA
02 4080d 01 9d

ET 344

SEKAYU
BCF-0341 BTS-0342
COMM
2013-09-02 11:33:26.96
*** ALARM TRX -008
AIRBALUIMG2
(52515) 7723 FAILURE IN SENDING SYSTEM INFORMATION TO BTS SITE
0A 14277d
SEKAYU
BCF-0341
*** ALARM
(45355) 7401 EXTERNAL AL 1

ENVIR

2013-09-19 06:49:49.74

MAINS FAIL
SEKAYU
BCF-0341
*** ALARM
(45375) 7402 EXTERNAL AL 2

ENVIR

2013-09-19 06:49:59.64

MODULE RECT FAIL


SEKAYU
BCF-0341 BTS-0344
QUAL
2013-09-18 16:11:26.28
** ALARM TRX -015
AIRBALUIMD1
(42030) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 00 00 00 00 00 00 00 00 01 61d
SEKAYU
BCF-0341 BTS-0341
QUAL
2013-09-17 08:10:49.78
** ALARM TRX -002
AIRBALUIMG1
(37832) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 01 00 06 02 35d
SEKAYU
BCF-0341 BTS-0344
QUAL
2013-09-18 15:11:24.26
** ALARM TRX -016
AIRBALUIMD1
(41892) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 01 00 00 05 01 52d
SEKAYU
BCF-0341 BTS-0344
QUAL
2013-09-18 16:11:26.28
** ALARM TRX -014
AIRBALUIMD1
(42031) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 00 00 00 00 03 01 81d
SEKAYU
BCF-0341 BTS-0346
QUAL
2013-09-18 16:11:26.28
** ALARM TRX -031
AIRBALUIMD3
(42032) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 00 01 07 01 36d
SEKAYU
BCF-0361 BTS-0366
EQUIPM
** ALARM TRX -032
MUARATELADANMD3
(26767) 7607 TRX OPERATION DEGRADED

2013-09-05 20:42:23.88

RSSI detected Rx signal difference exceeding threshold


17 06 00 82 00 00
SEKAYU
BCF-0371
*** ALARM
(44693) 7404 EXTERNAL AL 4
BATTERY STOLEN

ENVIR

2013-09-01 04:28:56.14

SEKAYU
BCF-0381
*** ALARM
(54423) 7404 EXTERNAL AL 4

ENVIR

2013-09-02 16:00:01.96

ENVIR

2013-08-19 12:34:49.38

COMM

2013-09-01 02:28:21.22

BATTERY STOLEN
SEKAYU
BCF-0391
*** ALARM
(58461) 7404 EXTERNAL AL 4
BATTERY STOLEN
SEKAYU

BCF-0401

*** ALARM
TRE -0001
(44042) 8081 LOSS OF FRAME ALIGNMENT
SINDANG MARGA MUBA
02 4080d 01 10d

2G Flexi FIQB

SEKAYU
BCF-0401
*** ALARM
(44044) 7402 EXTERNAL AL 2

ENVIR

ET2 523

2013-09-01 02:28:22.31

MODULE RECT FAIL


SEKAYU
BCF-0401 BTS-0403
QUAL
2013-09-18 11:11:14.18
** ALARM TRX -011
1SINDANGMRGMG3
(41253) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 00 00 00 01 07 01 30d
SEKAYU
BCF-0401 BTS-0403
QUAL
2013-09-18 13:11:18.21
** ALARM TRX -010
1SINDANGMRGMG3
(41641) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 01 00 00 00 00 00 00 01 00 63d
SEKAYU
BCF-0401
*** ALARM
(44043) 7401 EXTERNAL AL 1

ENVIR

2013-09-01 02:28:21.62

MAINS FAIL

SEKAYU
BCF-0414 BTS-0414
ENVIR
2013-09-12 18:58:51.38
ALARM
4ARUJAMUKTIMD1
(17388) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N
SEKAYU

BCF-0421 BTS-0421

ENVIR

2013-09-13 14:21:17.41

ALARM
N4SUBANEMBCGMG1
(22128) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0421 BTS-0422
ENVIR
2013-09-13 14:21:17.41
ALARM
N4SUBANEMBCGMG2
(22129) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0421 BTS-0423
ENVIR
2013-09-13 14:21:17.42
ALARM
N4SUBANEMBCGMG3
(22130) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0421 BTS-0421
QUAL
2013-09-17 14:10:57.89
** ALARM TRX -004
N4SUBANEMBCGMG1
(38468) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 01 00 00 00 00 00 02 00 30d
SEKAYU

BCF-0431

EQUIPM

2013-09-19 07:13:35.96

EQUIPM

2013-09-19 07:13:36.63

ENVIR

2013-09-19 07:07:03.97

ENVIR

2013-09-19 07:07:03.99

COMM

2013-09-19 07:14:05.94

** ALARM
PCM -0535
(45448) 7704 PCM FAILURE

SEKAYU

BCF-0431

** ALARM
PCM -0536
(45450) 7704 PCM FAILURE

SEKAYU
BCF-0431
*** ALARM
(45417) 7402 EXTERNAL AL 2
MODULE RECT FAIL
SEKAYU
BCF-0431
*** ALARM
(45418) 7405 EXTERNAL AL 5
BATTERY STOLEN
SEKAYU

BCF-0431

** ALARM
LAPD-0946
(45464) 7706 BTS O&M LINK FAILURE

SEKAYU
BCF-0491
*** ALARM
(60520) 7402 EXTERNAL AL 2

ENVIR

2013-09-10 16:33:21.07

ENVIR

2013-09-18 07:30:36.31

ENVIR

2013-09-18 16:19:15.96

ENVIR

2013-09-18 23:37:50.83

EQUIPM

2013-09-19 01:33:56.27

MODULE RECT FAIL


SEKAYU
BCF-0601
*** ALARM
(40552) 7402 EXTERNAL AL 2
GENSET FAIL
SEKAYU
BCF-0601
*** ALARM
(42045) 7401 EXTERNAL AL 1
DOOR OPEN
SEKAYU
BCF-0601
*** ALARM
(43692) 7403 EXTERNAL AL 3
LOW LOAD
SEKAYU

BCF-0601

** ALARM
PCM -0525
(43897) 7704 PCM FAILURE

SEKAYU
BCF-0601 BTS-0601
QUAL
*** ALARM
BINASAINSCMRMG1
(43899) 7767 BCCH MISSING

2013-09-19 01:33:56.60

SEKAYU
BCF-0601 BTS-0602
QUAL
*** ALARM
BINASAINSCMRMG2
(43900) 7767 BCCH MISSING

2013-09-19 01:33:57.03

SEKAYU
BCF-0601 BTS-0603
QUAL
*** ALARM
BINASAINSCMRMG3
(43902) 7767 BCCH MISSING

2013-09-19 01:33:57.46

SEKAYU

BCF-0601

** ALARM
LAPD-0711
(43907) 7706 BTS O&M LINK FAILURE

COMM

2013-09-19 01:34:15.00

SEKAYU
BCF-0601
PROCES
** ALARM
(44700) 7730 CONFIGURATION OF BCF FAILED

2013-09-19 05:00:05.58

13443d
SEKAYU

BCF-0604

EQUIPM

2013-09-19 01:33:55.01

** ALARM
PCM -0328
(43896) 7704 PCM FAILURE

SEKAYU
BCF-0604 BTS-0604
QUAL
*** ALARM
BINASAINSCRMD1
(43901) 7767 BCCH MISSING

2013-09-19 01:33:57.46

SEKAYU
BCF-0604 BTS-0605
QUAL
*** ALARM
BINASAINSCRMD2
(43903) 7767 BCCH MISSING

2013-09-19 01:33:59.95

SEKAYU
BCF-0604 BTS-0606
QUAL
*** ALARM
BINASAINSCRMD3
(43904) 7767 BCCH MISSING

2013-09-19 01:34:02.32

SEKAYU

BCF-0604

COMM

2013-09-19 01:34:14.97

** ALARM
LAPD-0834
(43906) 7706 BTS O&M LINK FAILURE

SEKAYU
BCF-0604
PROCES
** ALARM
(44701) 7730 CONFIGURATION OF BCF FAILED

2013-09-19 05:00:05.60

13443d
SEKAYU
BCF-0811
*** ALARM
(61476) 7402 EXTERNAL AL 2

ENVIR

2013-09-10 21:48:53.66

ENVIR

2013-09-10 21:48:54.01

MODULE RECT FAIL


SEKAYU
BCF-0811
*** ALARM
(61477) 7404 EXTERNAL AL 4
BATTERY STOLEN

SEKAYU
BCF-0811
*** ALARM
(43492) 7406 EXTERNAL AL 6

ENVIR

2013-09-18 22:14:34.15

GENSET FAIL

SEKAYU
BCF-0811 BTS-0813
ENVIR
2013-09-10 21:53:49.23
ALARM
WNPOTENSIGNMG3
(61498) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0821 BTS-0822
ENVIR
2013-08-30 21:35:58.93
ALARM
GAJAHMATMUBAMG2
(33915) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0821 BTS-0823
ENVIR
2013-08-30 21:36:40.64
ALARM
GAJAHMATMUBAMG3
(33921) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0821 BTS-0821
ENVIR
2013-08-30 21:35:15.91
ALARM
GAJAHMATMUBAMG1
(33910) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0821 BTS-0821
QUAL
2013-09-18 09:11:14.15
** ALARM TRX -001
GAJAHMATMUBAMG1
(40763) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 01 01 00 01 00 06 01 45d
SEKAYU
BCF-0821 BTS-0821
QUAL
2013-09-18 08:11:12.13
** ALARM TRX -004
GAJAHMATMUBAMG1
(40643) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 01 00 01 00 01 00 00 00 00 01 38d
SEKAYU
BCF-0821
*** ALARM
(43558) 7405 EXTERNAL AL 5

ENVIR

2013-07-03 20:57:40.86

BATTERY STOLEN
SEKAYU
** ALARM TRX -002

BCF-0821 BTS-0821
QUAL
GAJAHMATMUBAMG1

2013-09-18 08:11:12.13

(40644) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD


01 00 01 01 00 00 00 00 00 01 01 41d

SEKAYU
BCF-0821
PROCES
2013-07-15 10:15:48.57
ALARM
(45817) 7616 OSCILLATOR ADJUSTING TEMPORARILY INTERRUPTED
Clock tuning DAC word reaching min/max limit
00 00 00 82 00 00

SEKAYU
BCF-0831
*** ALARM
(12475) 7401 EXTERNAL AL 1

ENVIR

2013-09-11 22:29:52.29

MAINS FAIL

SEKAYU
BCF-0831 BTS-0831
ENVIR
2013-09-11 22:29:52.97
ALARM
SUNGAIMEDAKMG1
(12476) 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
N

SEKAYU
BCF-0831
*** ALARM
(12477) 7402 EXTERNAL AL 2

ENVIR

2013-09-11 22:29:53.17

ENVIR

2013-09-11 22:29:54.06

ENVIR

2013-09-11 22:29:54.16

ENVIR

2013-09-11 22:29:54.18

PROCES

2013-09-14 13:30:24.87

LOW BATT
SEKAYU
BCF-0831
*** ALARM
(12478) 7403 EXTERNAL AL 3
HIGH LOAD
SEKAYU
BCF-0831
*** ALARM
(12479) 7404 EXTERNAL AL 4
BATTERY STOLEN
SEKAYU
BCF-0831
*** ALARM
(12480) 7405 EXTERNAL AL 5
HIGH TEMP
SEKAYU

BCF-0831

** ALARM
RM -0011
(27691) 7607 TRX OPERATION DEGRADED

RF module filter tuning failed


00 00 00 83 11 11 1d 2d 4d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d
SEKAYU
BCF-0831 BTS-0831
PROCES
** ALARM
SUNGAIMEDAKMG1
(27692) 7604 BTS OPERATION DEGRADED

2013-09-14 13:30:24.96

RF module filter tuning failed


00 00 00 83 11 11
SEKAYU

BCF-0831

PROCES

2013-09-14 13:30:31.03

** ALARM
RM -0011
(27694) 7607 TRX OPERATION DEGRADED
RF module filter tuning failed
00 00 00 83 11 22 6d 7d 8d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d
SEKAYU
BCF-0831 BTS-0832
PROCES
** ALARM
SUNGAIMEDAKMG2
(27695) 7604 BTS OPERATION DEGRADED

2013-09-14 13:30:31.13

RF module filter tuning failed


00 00 00 83 11 22
SEKAYU

BCF-0831

PROCES

2013-09-14 13:30:34.14

** ALARM
RM -0011
(27696) 7607 TRX OPERATION DEGRADED
RF module filter tuning failed
00 00 00 83 11 32 10d 11d 12d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d

SEKAYU
BCF-0831 BTS-0833
PROCES
** ALARM
SUNGAIMEDAKMG3
(27697) 7604 BTS OPERATION DEGRADED

2013-09-14 13:30:34.17

RF module filter tuning failed


00 00 00 83 11 32
SEKAYU
BCF-0831 BTS-0833
QUAL
2013-09-14 14:09:50.83
** ALARM TRX -011
SUNGAIMEDAKMG3
(27793) 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
01 00 00 00 00 01 00 00 00 04 00 30d
SEKAYU
BCF-0831 BTS-0831
QUAL
** ALARM
SUNGAIMEDAKMG1
(28117) 7738 BTS WITH NO TRANSACTIONS
03

2013-09-14 16:00:34.75

SEKAYU
BCF-0831 BTS-0832
QUAL
** ALARM
SUNGAIMEDAKMG2
(28118) 7738 BTS WITH NO TRANSACTIONS

2013-09-14 16:00:34.75

03
SEKAYU
BCF-0831 BTS-0833
QUAL
** ALARM
SUNGAIMEDAKMG3
(28119) 7738 BTS WITH NO TRANSACTIONS

2013-09-14 16:00:34.75

03
SEKAYU

BCF-1014

PROCES

2013-09-05 15:17:51.96

** ALARM
RM -0011
(25322) 7607 TRX OPERATION DEGRADED
RF module detected too high Tx power
00 00 00 83 11 31 9d 11d 12d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d 0d

SEKAYU
BCF-1014 BTS-1016
** ALARM
SEREKAMD3
(25323) 7604 BTS OPERATION DEGRADED

PROCES

2013-09-05 15:17:52.02

RF module detected too high Tx power


00 00 00 83 11 31

END OF BTS ALARM LISTING


COMMAND EXECUTED
BASE TRANSCEIVER STATION ALARMS HANDLING COMMAND <EO_>
<
! -----------------------------------------------------------------------! MML commands execution ready in network element.
! Date and time: 2013-09-19 07:15:53
! Execution status: succesful.
! ------------------------------------------------------------------------

S-ar putea să vă placă și