CONDITION - FLOW MEDIUM LIQUID / VOLUMETRIC FLOW. INPUT DATA 1 2 3 4 5 6 7 SERVICE FLUID FLOW RATE (m3/hr) MAX / NOR / MIN (Q) INLET PRESSURE (P1) BARA OUTLET PRESSURE (P2) BARA DELTA P - SIZING (BAR) FLUID TEMPERATURE (T) 0K SPECIFIC GRAVITY (G) Since DELTA P > P1/2. Therefore, flow is critical. 4.85 8.41 2.9 5.51 265 0.88 DIESEL
Cv =
1.16QS Gr / DELTA P
Cv(max) =
2.34
Cv(Nor) =
0.00
Cv(Min) =
0.00
The flow coefficient - C v - let us compare flow capacities of valves at different sizes, types and manufacturers. The flow coefficie
For liquids the flow coefficient - C v - expresses the flow capacity in gallons per minute (GPM) of 60 o F water with a pressure dro Flow expressed by volume C v = q (SG / dp) 1/2 where q = water flow (US gallons per minute) (1)
ufacturers. The flow coefficient is in general determined experimentally and express the flow capacity in imperial units - GPM (US gallons per minute) of w
F water with a pressure drop of 1 psi (lb/in 2 ) . Flow is expressed by weight C v = w / (500 (dp SG) 1/2 ) where w = water flow (lb/h) (1c)
US gallons per minute) of water that a valve will pass for a pressure drop of 1 lb/in 2 (psi) .