Sunteți pe pagina 1din 27

REF.NO.

ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG


1 GROUP 1 - OVERALL SYSTEMS
1.01 REGULATIONS & CERT.
1.02 DOCUMENTATION
1.03 GENERAL INFORMATION
1.03.1 Vessel Design/type Friede&Goldman/"ExD" DPS-3
1.03.2 Registration (Flag)
1.03.3 Yard delivery Shanghai Waigaoqiao Shipbuilding Ltd.
1.03.4 Major modifications New building
1.03.5 Classification ABS
1.03.6 Additional class notations A1 Column Stabilized Drilling Unit, DPS-3,
1.03.7 Date of last 5-year class survey (SPS) New building
1.04. PERFORMANCE & CAPABILITIES
1.04.1 Displacement at operating draft (t) ~52200
1.04.2 Variable load-operation (t) 9000
1.04.3 Variable load-survival (t) 9000
1.04.4 Variable load transit (t) N/A
1.04.5 Max water depth (ft) 10,000
1.04.6 Min water depth (ft) 400
1.04.7 Design temperature hull (0 C)
Air: 40 maximum, -10 minimum
Water: 30 maximum, 0 minimum
1.04.8 Design temperature equipment (0 C)
Air: 40 maximum, 0 minimum
Water: 30 maximum, 0 minimum
1.04.9 Minimum operating temperature ( C) 0
Design Criteria operation:
1.04.10 Wind 1 hr sust. (kts) 45
1.04.11 Wave height sign. (ft) 19.685
1.04.12 Wave period (s) 11.2
1.04.13 Surface current (kts) 1.8
1.04.14 Max offset 2~3% water depth
1.04.15 Max heave (d.a.) (ft) 15
1.04.16 Max roll (d.a.) (deg) 5~7
1.04.17 Max pitch (d.a.) (deg) 5~7
Design Criteria Survival:
1.04.18 Wind 1 hr. sust. (kts) 107
1.04.19 Wave height sign. (ft) 13.3
1.04.20 Wave period (s) 15.5
1.04.21 Surface current (kts) 3.83
1.04.22 Max offset (% of WD) N/A
1.04.23 Max heave (d.a.) (ft) 50
1.04.24 Max roll (d.a.) (deg) 20
1.04.25 Max pitch (d.a.) (deg) 20
1.05 MAINTENANCE SYSTEM
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
Page 1 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
Databased system TBA
2 GROUP 2 - MARINE SYSTEMS
2.01 POWER SUPPLY & DISTRIBUTION
2.01.1 Type of system Generator driven by diesel engine
2.01.2 Number of generator sets 8
2.01.3 Power rating each forward (kW) N/A
Power rating each aft (KW) 5530
2.01.4 Total generated power (KW) 44240
2.01.5 Main power voltage (V) 11000
2.01.6 Main power frequency (Hz) 60
2.01.7 Approx. power consumption during normal drilling operations (KW) 21964
2.01.9 Fuel consumption at service speed (mt/day) 199
2.01.10 Fuel consumption in operation (bbl/day) 150000
2.01.11 Harbour generator (kW) Emergency generator include Harbour fuction
2.01.12 Emergency generator (KW) TBA
2.02 PROPULSION SYSTEM
2.02.1 Transit speed (knots) TBD
2.02.2 Main Propulsion:
2.02.3 Number of: N/A
2.02.4 Power cons. each (kW) N/A
2.02.5 Thrust force each (Mt) N/A
2.02.6 Controllable pitch (Y/N) N/A
2.02.7 Azimuth Thrusters:
2.02.8 Number of: 8
2.02.9 Power cons. each (kW) 4600
2.02.10 Thrust force each (t) 80
2.02.11 Controllable pitch (Y/N) N
2.02.12 Fixed/Retractible Fixed
2.02.13 Tunnel Thrusters:
2.02.14 Number of N/A
2.02.15 Power cons. each (kW) N/A
2.02.16 Thrust force each (Mt) N/A
2.02.17 Controllable pitch (Y/N) N/A
2.02.19 Total thrust available for DP (t) 640
2.03 MOORING SYSTEM : Harbour mooring only
2.03.1 No. of mooring lines 4
2.03.2 Chain, wire or combined system chain
2.03.3 No. of independent brake systems N/A
2.03.4 Central release of mooring lines N/A
2.03.5 Central release locations N/A
2.03.6 Automatic overspeed protection N/A
2.03.7 Permanent chaser system N/A
Page 2 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
2.03.8 Anchors type/weight (Mt) 10
2.03.9 An alarm indicating tension in the anchor line exceeding specified levels (Y/N) N/A
2.03.10 Automatic activation of anchor-winch deluge system during emergency release (Y/N) N/A
2.04 DYNAMIC POSITIONING SYSTEM
2.04.1 System make / type DP system
2.04.2 Back-up system type Single DP control system
2.04.3 IMO / NMD Consequence Class DP- 3
2.04.4 Position reference systems:
2.04.5 - DGPS Y
2.04.6 No.of / type 2 pcs/DP132(GPS/SBAS),DPS200(GPS/GLONASS)
2.04.7 - DGPS corrections Y
2.04.8 No. of / type Position accuracy:1m 95% CEP,Velocity accuracy 0.1m/s 95% CEP(*)
2.04.9 - Radio microwave N/A
2.04.10 No.of / type N/A
2.04.11 - Hydroacoustic Y
2.04.12 No.of / type 2 pcs
2.04.13 - Taut Wire N/A
2.04.14 No.of / type N/A
2.04.15 - El. riser angle indicator Y
2.04.16 No.of / type 1 pcs/seaflex (24v, <10w)
2.04.17 - Other references DP Sensors
2.04.18 No.of / type wind, gryo,MRU
2.04.19 Failure condition:
2.04.20 Maximum single failure one engine room or one switchboard room or one thruster room
2.04.21 Percentage loss of total thrust (%) 25
2.04.22 Max condition at max single failure:
2.04.23 - Wind (kts) 45
2.04.24 - Current (kts) 1.8
2.04.25 - Sign. Wave Height (ft) 18
2.05 ACOUSTIC POSITION CONTROL
2.05.1 System make/type ACOUSTIC
2.05.2 Positioning accuracy, % of slant range distance transducer-transponder
narrow receiver beam +5 ,operating area below vessel 100 , range dectection accruary
0.1m max at 20dB ,angle accuracy 0.21 at 20dB.
2.05.3 Cap. different transponder signal types / channels TBA
2.05.4 Cap. different signals simultaneously TBA
2.05.5 No. of signals simultaneously on screen TBA
2.05.6 VDU monitor locations CCR,ECR
2.05.7 No. of transducers 2
2.05.8 No. of transponders 6(MPT 5pcs,SPT 1 pcs)
2.05.9 Tuning of transponders on new location N/A
2.06 BALLAST SYSTEM
2.06.1 No. of separate pump rooms 8
2.06.2 No. of ballast pumps 8
Page 3 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
2.06.3 Capacity each (GPh) 79251.3
2.06.4 Variable speed (Y/N) N
2.06.5 Stripping system Y
2.06.6 Eductor capacity (gpm) 220
2.06.7 Ballasting time, transit to operation (h) 7
2.06.8 Deballasting time, operation to transit (h) 7
2.06.9 Deballasting time, operation to survival (h) 2
2.07 BILGE AND DRAIN SYSTEMS
2.07.1 Bilge water separator capacity (gph) 2642
2.07.2 At least one ballast pump is connected to the bilge system Y
2.07.3 One dedicated pump in each pontoon is connected to the emergency switchboard Y
2.07.4 Closed drain system collecting to seperate tank connected to bilge system Y
2.07.5 Drain from drill floor conn. to closed syst. (Y/N) Y
2.07.6 Drain from set back conn. to closed syst. (Y/N) Y
2.07.7 Drain from test unit conn. to closed syst. (Y/N) Y
2.07.8 Drain from pipe rack conn. to closed syst. (Y/N) Y
2.07.9 Drain from cement room conn. to closed syst. (Y/N) Y
2.07.10 Drain from mud room conn. to closed syst. (Y/N) Y
2.07.11 Drain from shaker room conn. to closed syst. (Y/N) Y
2.07.12 Drain from sack store conn. to closed syst. (Y/N) Y
2.08 COOLING WATER SYSTEM
2.08.1 No. of independent systems 4
2.08.2 Sea water system:
2.08.3 No. of pumps 4
2.08.4 Total capacity (gpm) 8800
2.08.5 Variable speed operation (Y/N) N
2.08.6 Fresh water system:
2.08.7 No. of pumps 3
2.08.8 Total capacity (gpm) 5500
2.08.9 Variable speed operation (Y/N) N
2.09 COMPRESSED AIR SYSTEM
2.09.1 Starting air:
2.09.2 No. of compressors 4
2.09.3 Capacity each (cuftr) 38m3/h&20m3/h (2&2)
2.09.4 Pressure (psi) 3.00
2.09.5 Design dew point temperature (deg C) N
Page 4 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
2.09.6 Service and Control air:
2.09.7 No. of compressors 3
2.09.8 Capacity each (CUFT/hr) 49526
2.09.9 Total capacity (CUFT/hr) 148578
2.09.10 Pressure (psi) 1.45
2.09.11 Design dew point temperature (deg C) -40
2.09.12 Provided with air dryers (Y/N) Y
2.10 DECK CRANES & OVERHEAD CRANES
2.10.1 Deck Crane no 1:
2.10.2 Location Port
2.10.3 Type / Make TBD
2.10.4 Rating (tm) 80 tons/24.0 m radius
2.10.5 Main hook SWL (t)
80 tons from 8.7 m to 24.0 m radius
32 tons from 8.7 m to 46.0 m radius
2.10.6 Auxiliary hook SWL (t) 15 tons from 11.0 m to 51.0 m radius
2.10.7 Deck Crane no 2:
2.10.8 Location Starboard
2.10.9 Type / Make TBD
2.10.10 Rating (tm) 80 tons/24.0 m radius
2.10.11 Main hook SWL (t)
80 tons from 8.7 m to 24.0 m radius
32 tons from 8.7 m to 46.0 m radius
2.10.12 Auxiliary hook SWL (t) 15 tons from 11.0 m to 51.0 m radius
2.10.13 Deck Crane no 3:
2.10.14 Location N/A
2.10.15 Type / Make N/A
2.10.16 Rating (tm) N/A
2.10.17 Main hook SWL (t) N/A
2.10.18 Auxiliary hook SWL (t) N/A
2.10.19 Knuckle Boom crane, Main Pipe Deck:
2.10.20 Capacity SWL (t) 15T
2.10.21 Tubular handling capacity 15T
2.10.22 Max tubular length (ft) 14000mm
2.10.23 Max height (FT) 41200mm
2.10.24 Riser handling crane, Aft Deck:
2.10.25 Capacity SWL (t) 40mT
2.10.26 Tubular handling capacity 0.1m/s
2.10.27 Max riser length (ft) 75
2.10.28 Max height (FT) TBD
2.10.29 Overhead crane, subsea equipment: Tree Assembly Crane & Trolley
2.10.30 Capacity SWL (t) 2x75T
2.10.31 Max stack-up height (FT) 32
2.11 ENVIRONMENTAL AND PLATFORM DATA (E&P DATA)
2.11.1 Provisions for central monitoring of:
2.11.2 Wind speed and direction
2 pcs ultrasonic wind sensor II (40mA at 24VDC) and
1 pcs vane-anemometer wind sensor OMC-160 (60mA at 24VDC)
Page 5 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
2.11.3 Wave height, period and direction Y
2.11.4 Current speed and direction * Y
2.11.5 Air temperature OMC-443 (9 to 30VDC,4 to 10mA)
2.11.6 Air pressure Setra 470 (100 to 240VDC, 70ma max)
2.11.7 Sea water temperature N/A
2.11.8 Vessel roll MRU (12 to 30VDC, max 14.5W, IP66)
2.11.9 Vessel pitch MRU (12 to 30VDC, max 14.5W, IP66)
2.11.10 Vessel heave MRU (12 to 30VDC, max 14.5W, IP66)
2.11.11 Vessel heading Navigat X Mk.1 (115/230VAC normal, 24VDC emergency, 45w)
2.11.12 Vessel draught IL-10 (0 to 0.4 MP ,accuracy 0.5%)
2.11.13 Accoustic Doppler Current Profiler N/A
2.12 COMMUNICATION SYSTEMS
2.12.1 Satellite Communication system Y
2.12.2 No. of dedicated telephone lines for Operators offices on RigNet SatCom system At least 16pcs
2.12.3 No. of telefax lines on RigNet SatCom system At least 3pcs
2.12.4 No. of telefax machines for operator use About 200 telephones.Can use fax by Satellite
2.12.5 No. of mobile phones for operator use 25 UHF handsets
2.12.6 Line for sync./async.data communication Satellite bandwidth can reach to 2Mbits/s
2.12.7 No. of UHF transceivers (w/ headsets)
Five. Each crane have one transceiver.The others are installed in radio room and central
control room
2.12.8 No. of VHF transceivers Three.Two in radio room and one in central control room
2.12.9 communication between :
2.12.10 Deck crane - deck Use UHF equipment.Crane will have speaker to broadcast
2.12.11 Deck crane - drillfloor Use UHF equipment.
2.12.12 Drill floor - cement unit Use Auto telephone, talkback, PA/GA access panel or UHF equipment
2.12.13 Drill floor - cellar deck Use Auto telephone, talkback, PA/GA access panel or UHF equipment
2.12.14 Drill floor - derrick man (derrick & pump room) Use Auto telephone, talkback, PA/GA access panel or UHF equipment
2.12.15 Drill floor - pipehandling pipe deck Use Auto telephone, talkback, PA/GA access panel or UHF equipment
2.12.16 Drill floor- person in riding belt ("hand-free") PA/GA Speaker,talkback or UHF hand-free equipmentt
2.12.17 PA system and telephone to all third party containers uniform interface like junction box installed nearby third party containers
3 GROUP 3 - DRILLING AND COMPLETION EQUIPMENT
3.01 THE DRILLING DERRICK AND EQUIPMENT
3.01.1 Derrick rating (t) 907.2T
3.01.2 Hook SWL (t) 907.2T
3.01.3 Top Drive connected to Traveling block (Y/N) Y
3.01.4 Racking capacity, 5 7/8" D.P. (FT) 108 stands
3.01.5 Racking capacity, 6 5/8" D.P. (FT) 204 stands
3.01.6 Racking capacity of 8" D.C. (ft) TBD
3.01.7 Racking capacity, 9 1/2" D.C. (FT) 20 stands
3.01.8 Racking capacity, marine riser jnt. 99ea
3.01.9 Racking capacity, 13 5/8" Csg. OR 9 5/8 csg
13 5/8" -- 49x135'
9 5/8"--72x135'
3.01.11 Setback weight capacity (t) 2.44t/m2
Page 6 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.01.12 Stabbing board for casing, adj. height 107'-8"
3.01.13 Derrick racking height (ft) 210ft
3.01.14 Overdrill, by 1m stick up cont. (ft) TBD
3.01.15 Stand length (ft) 46ft x 52ft
3.01.16 Powered sliding door in front of the V-door opening (Y/N) Y
3.01.17 Company logo/ well no.to be installed in derrick Y
3.02 HOISTING EQUIPMENT
3.02.1 Max pull elevator (t)
3.02.2 Passive and active compensation. Y
3.02.3 Hoisting equipment in derrick , and elevators, acc.to API spec.8C PSL 1 or PSL 2 Y
3.02.4 Max pull speed 240rpm
Safety device to prevent the travelling yoke :
3.02.5 - Being run into the top 125rpm
3.02.6 - Being run into the drillfloor 125rpm
3.02.7 - Being run into the stabbing basket 125rpm
3.02.8 Travelling block SWL (t) 907T
3.02.9 No.of personnel winches covering cellar deck 2
3.02.10 No.of personnel winches covering drillfloor 2
3.02.11 Personnel winches in compliance with NPD 28 (ref. 1.01.1 /1/)
3.02.12 Workwinches on drillfloor: ea./ t
5T X 2
10T X 2
3.02.13 Workwinches on cellardeck: ea./ t
5T X 2
10T X 2
3.02.14 Two separate brakes,one automatic, on the work winches Y
3.02.15
At Coinencement Date the drilling line shall be slipped and/or cut to provide zero ton-
mile TBD
3.02.16 Enough drilling line wire onboard for complete change. Y
3.03 DRILLING INSTRUMENTATION
Drillers panel with following as a minimum:
3.03.1 Pump pressure gauge Y
3,03.2 Cement line press indicator Y
3.03.3 Weight indicator Y
3.03.4 Pump strokes counter/ total strokes Y
3.03.5 Tong torque indicator Y
3.03.6 Iron roughneck torque indicator Y
3.03.7 Rotary/top drive torque Y
3.03.8 Cathead torque Y
3.03.9 Rotary/top drive speed indicator Y
3.03.10 PVT system Y
3.03.11 Trip tank level indicator w/alarm Y
Page 7 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.03.12 Gain/loss indicator w/alarm Y
3.03.13 Mud flow out Y
3.03.14 Yoke position indicator Y
3.03.15 Ton-milr recorder Y
3.03.16 Riser tension ton-mile recorder Y
3.03.17 Drilling parameters chart recorder Y
3.03.18 Top drive control panel Y
3.03.19 Drill string compensator panel Y
3.03.20
Choke and Kill panel high accurracy pressure measurement on low and high
pressures Y
3.03.21 Back-up system with power black-out (Y/N) Y
3.04 TOP DRIVE SYSTEM
3.04.1 Static load capacity (t) 907
3.04.2 Power continuous (KW) 857
3.04.3 Max. torque at 145 rpm (ftlbs) 94.500 ft.lb at 0-125 rpm
3.04.4 Max. torque make up (ftlbs) TBD
3.04.5 Max. rotating speed 240RPM
3.04.6 Inner diameter of swivel and through the TD (IN) TBD
3.04.7 Make up/break out wrench, capacity (ftlbs) TBD
3.04.8 Tiltable bails (deg) TBD
3.04.9 Independent rotation of bails/elevator (Y/N) Y
3.04.10 Upper kelly cock-remote (psi) TBD
3.04.11 Lower kelly cock-manual (psi) TBD
3.04.12 Top drive system D.P.size range from/to (inch) 3 1/2''-6 5/8''
3.04.13 All functions for the top drive remotely controlled from the driller`s control panel Y
3.0414 Access through the top of the top drive for wireline operation TBD
3.05 ROTATION SYSTEM
3.05.1 Motor rating hydraulic motor 210bar
3.05.2 High/low speed (Rpm) 20rpm/--
3.05.3 Opening diameter rotary (inch) 60 1/2" - 49 1/2"
3.05.4 Load rating (t) 907
3.05.5 Independent(simultanously) operating of TD and rotary table (Y/N) N
3.06 BULK SYSTEM
3.06.1 Barite capacity (CuFt) OR Bentonite capacity (CuFt) 553M
3
3.06.3 Cement capacity (CuFt) 350M
3
3.06.4 Barite transfer rate to surge tanks (tons/hr) 80t/h
3.06.5 Cement transfer to surge tank (tons/hr) 40t/h
3.06.6 Number of barite surge tanks 2
3.06.7 Number of cement surge tanks 1
3.06.8 Barite transfer to cement surge tank (tons/hr) 80t/h
3.06.9 Number of barite or bentonite storage tanks 11
3.06.11 Number of cement storage tanks 5
3.06.12 Accuracy of surge tank load cells (LB) <1t
Page 8 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.06.13 Storage tank load cells (Y/N) Y
3.06.14 Direct barite to active pits Y
3.06.15 Supply hoses length (FT) 60M
3.06.16 Possible to mix barite in hoppers while taking onboard bulk barite from supply vessel Y
3.06.17 Control panels and compressor hooked up to the emergency generator N
Page 9 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.07 CEMENTING SYSTEM
3.07.1 1 ea 80 cuft steady flow bin Y
3.07.2 1 ea hydraulic power pack N
3.07.3 1 ea lap system N
3.07.4 1 ea diesel fuel tank Y
3.07.5 2 ea air receiver N
3.07.6 1 ea remote control N
3.07.7 1 ea Compupac (data acquisition computer) Y
3.07.8 1 ea tool box/special tools for unit Y
3.07.9 1 ea emergency mixing equipment Y
3.07.10 1 ea acoustic bulkhead for cemt unit N
3.07.11 1 ea acoustic bulkhead for hydraulic power pack N
3.07.12 1 ea h-manifold, complete with valves Y
3.07.13 5ea Chiksan spool fro h-manifold to rig line Y
3.07.14 6 ea Chiksan 90O bend from h-manifold to rig line Y
3.07.15 1ea spare parts cupboard N
3.07.16 1 ea adjustable work bench N
3.07.17 1 ea las tank Y
3.07.18 2 ea remote radiator for cement unit N
3.07.19 1 ea sink Y
3.07.20 1 ea tool cabinet w/hand tools N
3.07.21 HCS 25d cement unit w/2 ea cat 3406 diesel engine Y
3.07.22 High pressure pump rating (bar) 15,000PSI
3.08 RUNNING AND HANDLING OF TUBULARS
3.08.1 Iron roughneck Y
3.08.2 Drill floor manipulator arm Y
3.08.3 Remote casing tong N
3.08.4 Pipe handling system from fingerboard on drill floor level Y
3.08.5 Cat head (EZY torque) Y
3.08.6 Block retraction system Y
3.08.7 Kelly spinner Y
3.08.8 2 set handling equipment for all tool sizes Y
3.08.9
Remote controll systems for transport of DP,DC Csg. etc. from pipedeck to the
drillfloor Y
3.08.10 Remote operated handling tools for all tubulars Y
3.09 DRILLING FLUID SYSTEM
3.09.1 Trip tank capacity (BBLS) 9.1M3
3.09.2 Main mud tanks capacity (BBLS) 1104M3
3.09.3 Brine storage capacity in addition to mud cap. (BBLS) 723M3
3.09.4 Mud cleaner, number 2
3.09.5 Desander, number 3
3.09.6 Centrifuge, number 3
3.09.7 Variable speed centrifuge N
3.09.8 Degassers, number 2
3.09.9 Degasser capacity full flow GPM 1400GPM
Page 10 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.09.10 Shakers, number 4
3.09.11 Shakers, make/model TBD
3.09.12 Number of high pressure pumps TBD
3.09.13 Power output pr. pump (hP) 125HP
3.09.14 Liner dimensions in HP mudpumps 5"~7 1/2"
3.09.15 Liner stroke (in) 14"
3.09.16 Number of mixing hoppers 2
3.09.17 Automitised mixing system stations 2
3.09.18 Atmospheric degasser ventline diameter (inch) 12"
3.09.19 Atmospheric degasser liquid seal (FT) 6.1M
3.09.20 Atmospheric degasser liquid outlet (inch) 10"
3.09.21 Atmospheric degasser mud inlet (from choke manifold) (inch) 5"
3.09.22 Capacity of degasser tank (BBLS ) 3.56M3
3.09.23 Mud buckets for relevant pipe size 6"
3.09.24 Suction/discharge module back-up for mud pumps available onboard (Y/N) Y
The surface mud circulation system:
3.09.25 Withstand a drilling fluid temperature of (0C) Y
3.09.26 Able to handle a minimum mud flow of: (GPM) 2200GPM
3.09.27 Handle a drilling fluid density of: ( ppg ) 21PPG
3.09.28
Centrifugal pumps have mechanical seal. (Flushing with anti leaking fluid is not acc.) Y
3.09.29 Treatment pit equipped with high pressure mud guns (100 bar) Y
3.09.30 Possible to mix in all hoppers without dust problems Y
3.09.31
Mud pit furnished with dust free direct barite mixing system, for continous mixing of
barite direct into active- and reserve pit Y
3.09.32 Deck hopper or equivalent for mixing of big bags installed (Y/N) Y
3.09.33 Possible to take suction for the mud pumps from all pits Y
3.09.34 A gumbo trap installed on flowline before shaker box Y
3.09.35 Brine tank have recirculation possibility Y
3.09.36
The derrick ventline ,separator and liquid seal capacity to handle a gas flowrate of :
(l/sec) TBD
3.10 DRILLING WELL CONTROL SYSTEM & MARINE RISER
Blowout preventer general:
3.10.1 Make TBD
3.10.2 Dimension (inches) 18 3/4"
3.10.3 Working pressure (psi) 15,000PSI
3.10.4 Choke/kill outlets 1/1
3.10.5 Design temp min./max. ( o C) 75
3.10.6 No. of rams 6
3.10.7 No. of annulars 2
3.10.8 4 year inspection performed (date) N/A
Wellhead connector:
3.10.9 Make TBD
3.10.10 Fluid volumes open/close/secondary (g) TBD
3.10.11 The wellhead connector profile suit Vetco H4 profile Y
3.10.12 Hydrate protection seal TBD
Page 11 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.10.13 Glycol injection in connector TBD
Pipe rams:
3.10.14 Open/close volume (g) 15.76/16.77
3.10.15 Temp.rating max. min. ( o C) TBD
3.10.16 Fixed high temp. ram for relevant pipe. No. of: TBD
3.10.17 Variable ram blocks for relevant pipes TBD
3.10.18 Variable rams in 2 cavities. TBD
3.10.19 Mechanical ram lock system for pipe rams TBD
Shear rams:
3.10.20 The shear rams shall be able to shear and seal on minimum specified tubulars TBD
3.10.21 Open/close volume ram 1(g) TBD
3.10.22 Cylinder size ram 1 TBD
3.10.23 Type shear ram blocks ram 1 TBD
3.10.24 Open/close volume ram 2(l) TBD
3.10.25 Cylinder size ram 2 TBD
3.10.26 Type shear ram blocks ram 2 Cameron super shear ram TBD
3.10.27 Temp. rating max./min. ( o C) TBD
3.10.28 Pressure to shear subject drill pipe (psi) TBD
3.10.29 Pressure to shear Expro shear sub TBD
3.10.30 Pressure to shear 13 5/8" csg TBD
3.10.31 Spare blocks (Y/N) TBD
3.10.32 Mechanical ram lock system for shear rams. TBD
Page 12 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
Upper annular preventer:
3.10.33 Make/type TBD
3.10.34 Open/close volume (g) TBD
3.10.35 Temp. rating ( o C) TBD
3.10.36 Pressure rating (PSI) TBD
3.10.37 Outlet under UAP TBD
Lower Annular preventer:
3.10.38 Make/type TBD
3.10.39 Open/close volume (g) TBD
3.10.40 Temp.rating (o C) TBD
3.10.41 Pressure rating (PSI) TBD
Lower Marine Riser Connector:
3.10.42 Make/type 18-3/4" Style HAR
3.10.43 Open/close/sec.open volumes (l) TBD
3.10.44 Max. disconnect angle (deg.) TBD
3.10.45 High angle release TBD
Flex joint:
3.10.46 Make/type 8-3/4" -10M
3.10.47 Min. I.D. (in) TBD
3.10.48 Max. bending angle (deg.) 10
Kill & Choke valves:
3.10.49 Make/type TBD
3.10.50 Open/close volume (g) 2.00/2.00
3.10.51 Min. I.D. (in) TBD
3.10.52 Temp. rating (o C) TBD
3.10.53 Hydraulic press. assist close on remote operated valves TBD
3.10.54
Able to close against dynamic flow w/surface controlsystem not intact
TBD
3.10.55 Able to close the valves with full flow through valve TBD
Choke/kill coupling between LMRP/BOP:
3.10.56 Make/type TBD
Choke/kill line flexible loops Subsea BOP:
3.10.57 Make/type TBD
3.10.58 Material TBD
3.10.59 H2 S resistant Y
3.10.60 Connection type. Clamp or flange. TBD
3.10.61 Last certified (date) N/A
BOP control system:
3.10.62 Main control unit make/type MUX
3.10.63 Surface accumulator size, ea bottle TBD
3.10.64 No. of surface accumulators TBD
3.10.65 Accumulator working pressure TBD
3.10.66 BOP stack mounted bottles, size ea. TBD
3.10.67 Accumulator working pressure TBD
3.10.68 No. of BOP stack mounted bottles TBD
3.10.69 BOP hydraulic fluid system closed system (e.g no dump to sea) TBD
3.10.70 Hydraulic fluid type TBD
Page 13 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.10.71 Hydraulic fluid system open return to sea (Y/N) Optional TBD
3.10.72 BOP fluid accepted by SFT TBD
3.10.73 Fluid mixing system TBD
3.10.74 Power fluid tank (g ) TBD
3.10.75 Control fluid tank (g ) TBD
3.10.76 Antifreeze fluid tank (g ) TBD
3.10.77 No. of air operated pumps TBD
3.10.78 No. of el. operated pumps TBD
3.10.79 Regulators on H.P. unit unaffected by loss of control signal TBD
3.10.80 Safety device on W.H. connector unlatch TBD
3.10.81 Retrievable pods TBD
3.10.82 Age of BOP control bundles N/A
3.10.83 Length of BOP control bundles (ft) 11,000
3.10.84 Spare signal in each bundle (Y/N) TBD
Page 14 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
Accoustic backup system:
3.10.85 Make/type TBD
3.10.86 Accoustic backup system to operate at max. water depth for the rig (Y/N) TBD
3.10.87 BOP mounted accumulators (size) TBD
3.10.88 BOP mounted accumulators (no.) TBD
3.10.89 Accumulator working pressure TBD
3.10.90 Fixed control unit TBD
3.10.91 Portable control unit TBD
3.10.92 Retrievable accoustic package (Y/N) TBD
Functions connected to the accoustic system
3.10.93 Locking system on rams if separate TBD
3.10.94 LMRP connector unlatch TBD
3.10.95 Shear rams close TBD
3.10.96 Upper pipe/shear rams close TBD
3.10.97 Middle pipe rams close TBD
3.10.98 Lower pipe rams close TBD
Choke Manifold:
3.10.99 Make/type TBD
3.10.100 Working Pressure (psi) 15,000
3.10.101 H
2
S service Y
3.10.102 No. of remote chokes 2
3.10.103 No. of manual chokes 2
3.10.104 Glycol injection upstream choke(Y/N) Y
3.10.105 Up/downstream pressure monitoring (Y/N) Y
3.10.106 Up/downstream temperature monitoring (Y/N) Y
3.10.107 Remote operated valves (no) Y
3.10.108 Outlet downstream to poorboy degasser Y
3.10.109 Outlet downstream direct to well test burner booms Y
3.10.110 Possible to flowcheck outlet from poorboy degasser on trip tank (Y/N) Y
3.10.111 Function of the BOP kill and choke lines interchangeables TBD
3.10.112
Separate pressure gauges for the kill and choke lines can be read independently and
simultanously from the drillers house. High accuracy. Y
Diverter System:
3.10.113 Make/type TBD
3.10.114 Nominal size (in) 75 1/2"
3.10.115 Working pressure (psi) 500
3.10.116 Design temp. (o C) TBD
3.10.117 Packer insert ID/ranges TBD
3.10.118 No. of lines 6
3.10.119 No. of bends and corresponding angels TBD
3.10.119 Diverter closing time (sec) TBD
3.10.120 Integrated to BOP control system TBD
3.10.121 Diverter line diameter ID (in) 16"
3.10.122 Flowline diamter ID (in) 16"
3.10.123 Auto sequence when closing diverter Y
3.10.124 The valves in the diverter system remotely operated (Y/N) Y
Page 15 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.10.125
All regulators in control system remain unaffected in the event of loss of power supply
in loss of regulation air/fluid Y
Sub sea TV monitoring system:
3.10.128 Make/type N/A
3.10.129 No. of cameras N/A
3.10.130 Winch capacity N/A
3.10.131 Depth metering (Y/N) N/A
3.10.132 Control location N/A
3.10.133 Monitor in operator office N/A
Page 16 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
Surface TV monitoring system:
3.10.134 No. of cameras 26
3.10.135 Camera on drill floor Y
3.10.136 Camera in moon pool (Y/N) Y
3.10.137 Camera in shaker room Y
3.10.138 Camera in derrick Y
3.10.139 Camera in pump room (Y/N) Y
3.10.140 Monitor in drillers house Y
3.10.141 Monitor in toolpushers office (Y/N) Y
3.10.142 Monitor in operator office Y
3.10.143 Signal cables from ROV units to drill floor Y
Marine Drilling Riser General:
3.10.144 Make/type TBD
3.10.145 Min. design temp. (o C) TBD
3.10.146 Max. water depth (ft) TBD
3.10.147 Min. temp. rating seals (o C) TBD
3.10.147 Min. I.D. (in) TBD
3.10.149 Tapered cross sectional changes TBD
3.10.148 Riser Anti Collapse valve or equal TBD
3.10.149 Riser anti recoil system Y
3.10.150 Instrumented riser joint TBD
3.10.152 Riser hang off and support system Y
Upper flex joint/ball joint:
3.10.155 Make/type TBD
3.10.156 Max. load capacity (t) TBD
3.10.157 Max. angular deviation (deg) 10
3.10.158 Min. I.D. (in) TBD
Telescopic joint:
3.10.159 Make/type TBD
3.10.160 Min. I.D. (in) TBD
3.10.161 Dimensions - extended (ft) 75
3.10.162 Dimensions - collapsed (ft) 25
3.10.163 Capacity collapsed/locked (t) TBD
3.10.164 Capacity extended (tt) TBD
3.10.165 Type of sealing elements top TBD
3.10.166 Type of sealing elements bottom TBD
3.10.167 Riser pressure rating (psi) TBD
3.10.168 Pressure rating on seal elements (psi) TBD
Flexible kill and choke lines: (Cellar deck)
3.10.169 Make/type TBD
3.10.170 Pressure rating (psi) TBD
3.10.171 Type connection. Hub or flange. TBD
3.10.175 Bend restrictors TBD
3.10.172 H
2
S resistant TBD
3.10.177 Temp. rating (o C) TBD
3.10.173 Spare hose (Y/N) TBD
Page 17 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.10.174
Last inspection (certified) by supplier (date) in moonpol shall be certified prior to
entering Contract) TBD
MarineRiser sections:
3.10.175 Make/type TBD
3.10.181 Size OD (in) 21
3.10.176 No.of joints 134
3.10.177 Connection type TBD
3.10.178 Length (ft) 75
3.10.179 Pup joint lengths/no. of (FT) TBD
3.10.187 Coupling type TBD
3.10.180 Choke/kill line press. rating (psi) 15000
3.10.181 Choke/kill line temp. rating 75
3.10.182 Choke/kill line H2 S resist Y
3.10.183 Buoyancy modules total length (FT) TBD
3.10.184 Buoyancy type TBD
3.10.185 Handling & test tools TBD
Miscellaneous:
3.10.186 ROV hotstab. for operating certain BOP functions Y
3.10.187 BOP service crane/work platform (Y/N) Y
3.10.188
Able to do a full pressure test and function test of the BOP/LMRP on test
stump.Hydraulic test station. Y
Page 18 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.10.189 Service trolley over moon pool N
3.10.190 Guidance system for BOP through moon pool. Y
3.10.191 Handling system make/type TBD
3.10.192 Handling system capacity (t) 550
3.10.193 Retractable test stump Y
3.10.194 Test valves on C/K line on LMRP TBD
3.10.195 Jacks on LMRP TBD
3.10.196 BOP reinforcement TBD
3.10.197 Pressure and temp. probe under LMRP TBD
3.10.198 BOP max. footprint for HOST 4,5m x 3,8m TBD
3.10.199 Quick annulus dump system TBD
3.10.200 Emergency BOP recovery system TBD
3.11 COMPENSATING SYSTEM
3.11.1 Top mounted heave comp. (Y/N) Y
3.11.2 Static load capacity (lb) 2 500 000
3.11.3 Dynamic load capacity (lb) 1 000 000
3.11.4 Compensating length drillstring (ft) 25
3.11.5 Riser tensioner, max. total force (lb) 16 861KN
3.11.6 Compensating length riser tensioner (ft) 33 240mm
3.11.7 Guideline tensioners, max. total force (KN) TBD
3.11.8 Comp. length guideline tensioner (ft) 2800mm
3.12 HANDLING OF SUBSEA EQUIPMENT
3.11.1 Skid system for transport of Xmas trees (Y/N) Y
3.11.2 Transfer skids for storage of modules (Y/N) Y
3.11.3 Trolley capacity (t) 2X75
3.11.4 Power
Hydraulic:225 l/min 200bar
Electrical:230VAC/60HZ/20A
3.13 HYDRAULIC POWER UNIT
3.13.1 Make, type 3X94KW,6X94KW
3.13.2 Ring line's pressure (PSI) 207BAR
3.14 DRILL STRING COMPONENTS
3.14.1 Kelly N
3.14.2 (Kelly) saver sub (Y/N) N
3.14.3 6 5/8" OD drill pipe S-135 (ft) TBD
3.14.4 5 7/8" OD drill pipe S-135 (ft) TBD
3.14.5 5" OD drill pipe S-135 (ft) TBD
3.14.6 3 1/2" OD drill pipe S-135 (ft) TBD
3.14.7 5 7/8", 3 1/2" DP pup jnt. S-135 TBD
3.14.8 5 7/8" HW DP TBD
Page 19 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.14.9 9 1/2" spiral DC TBD
3.14.10 8 1/4" spiral DC TBD
3.14.11 6 3/4" spiral DC TBD
3.14.12 4 3/4" spiral DC TBD
3.14.13 Circulating heads for relevant DP TBD
3.14.14 Kelly cocks for 3 1/2" and 5 7/8" DP TBD
3.14.15 Inside BOP 5 7/8" TBD
3.14.16 Dart Sub w/dart TBD
3.14.17 Float valves (no orifice) to fit bit subs TBD
3.14.18 Bit subs bored for float to fit all bit size TBD
3.14.19 Cross over subs TBD
3.14.20 Bit breakers (26", 17 1/2", 12 1/4", 9 7/8", 8 1/2", 6") TBD
3.14.21 Bit gauges (26", 17 1/2", 12 1/4", 9 7/8", 8 1/2", 6" TBD
3.15 FISHING EQUIPMENT
3.15.1 Overshots (11 1/4", 8 1/8" and 5 3/4") TBD
3.15.2 Jars (8", 6 1/2") TBD
3.15.3 Intensifier/accelerator (8", 6 1/2") TBD
3.15.4 Bumper subs (8", 6 1/2") TBD
3.15.5 Junk subs TBD
3.15.6 Reverse cir. junk basket TBD
Page 20 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.15.7 Junk mills (12 1/8", 8 3/8", 5 7/8") TBD
3.15.8 Taper taps TBD
3.15.9 Ditch magnet (Y/N) TBD
3.16 CASING HANDLING
3.16.1 Remote operated handling tools for CSG sizes. Y
including 22" casing to be run in moonpool offline BOP side
3.17 WELL TESTING SYSTEM
Production stand pipe and production flowline from drillfloor to test area ,choke
manifold :
3.17.1 Pressure rating (bar) 15000PSI
3.17.2 Nominal OD (in) 5"
Production flowline between choke manifold and heater:
3.17.3 Pressure rating (bar) 5000PSI
3.17.4 Nominal OD (in) 4"
High pressure gas line from test area to burner booms:
3.17.5 Pressure rating (bar) 300PSI
3.17.6 Nominal OD (in) 4"
Low pressure gas line from test area to burner booms:
3.17.7 Pressure rating (bar) 125PSI
3.17.8 Nominal OD (in) 2"
3.17.9 Flame arrestor installed Y
Oil/condensate line from test area to burner booms:
3.17.10 Pressure rating (bar) 200PSI
3.17.11 Nominal OD (in) 2"
Piping general:
3.17.12 All pipes from drillfloor to booms H2S service Y
3.17.13 All lines have drain points at lower sections Y
3.17.14
Flowside outlet connection to be 4 1/16" Cameron hub no. 6 (suitable for Coflexip flow
hoses) with connection mounted up in derrick Y
3.17.15 Burner boom manifold valves (Threeway, Y/N) Y
3.17.16 Diverter system independent of test system Y
Burner booms:
3.17.17 Length (ft) 30M
3.17.18 Slewing angle (Deg) 120
3.17.19 Burner head weight (expected load) (lb) TBD
3.17.20 Design temperature (0 C) TBD
3.17.21 Ice load (lb) N
Cooling water supply:
3.17.22 Capacity (burner head) (GPM) TBD
3.17.23 Capacity of burner water sprinkler shield (GPM) 5.15M3/M
3.17.24 Sprinkler shield (ring) distance from burner head (ft) TBD
3.17.25 Capacity (rig cooling) (GPM) 350M3/H
Electrical equipment:
3.17.26 Zone classification SAFE AREA
Page 21 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
3.17.27 Electrical supply (stabilized), test area (V/Hz) 480V 60HZ
Instrument air supply:
3.17.28 Pressure (bar) 7.0
3.17.29 Volume (GPM) TBD
Steam supply:
3.17.30 Pressure (bar) TBD
3.17.31 Temperature () TBD
3.17.32 Volume (ft3/hr) TBD
Page 22 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
4 GROUP 4 - HSE
4.01 HEALTH CARE SYSTEM
4.01.1 No. of hospital berths 1
4.01.2 First aid cabinet at: Drillfloor, mud pump room, engine-/ control room, and gally Y
4.01.3
Eye wash station at: Drill floor, mudpump-, cement unit-, shale shaker-, mixing
hoppers-, hydraulic room, health office and sack storage area for chemicals Y
4.01.4
Emergency area ( for sorting and preliminary treatment of injured personel in case of
major accidents) located so that safe stretcher transport of injured personel is possible
to and from the area. Y
4.01.5 Total no. of stretchers 3
4.01.6 Hoisting equipment for stretchers Y
4.02 LIVING QUARTERS
4.02.1 All upper beds equipped with arrangement to prevent people from falling out of bed Y
4.02.2 Individual temperature regulation possible in bedrooms Y
4.02.3 Living quarter has a positive pressurised system
To guarantee the overpressure 50Pa of the accommodation against outside, the
accommodation rooms will be sealed from the corridors. The corridors will be also supplied
and exhausted with air-conditioned air, The overpressure 50Pa in corridor will be controlled
by air difference between supply capacity over exhaust capacity.
4.02.4 No. of offices, operator personnel TBD
4.02.5 Total no. of working places at operator offices TBD
4.02.6 Provision store rooms: Direct access to/from workdeck Y
4.03 FIRE AND GAS PROTECTION SYSTEM
Fire and gas detection/alarm system:
4.03.1 System test facilities provided
Test gas bottble,Test gas unit,heat detector test kit,Test magnet for flame detector,
Testkey for BF-501 and BF-502/N.EX,Test equipment for H2S gas detector test gas 50ppm
H2S,Calibration kit for H2 gas detector,Hydrogen 50% LEL
4.03.2
System of a self-diagnostic type where failure in any detector or field cable is indicated
by a fault alarm in the main control centre
Y
4.03.3
Smoke detectors of ionisation type and installed in enclosed areas where combustible
and electric fires may develop, e.g. switchgear, control, and power generating rooms
and accomodation area
Smoke detector is optical type
4.03.4
Smoke and heat detectors equipped with selfcontained alarm indicators that once
activated remain illuminated until reset
Y
4.03.5 Continously monitoring gas detectors (intermittent monitoring not acceptable) Y
4.03.6
Gas detection monitored in main control room, drillers console drill floor and pilot
house
Y
4.03.7
Min. one of the gas detection monitoring panels indicates gas concentration in LEL
Y
No of flainable gas/H2S detectors installed in:
4.03.8 Mud room Gas detector 14 pcs, H2S detector 3 pcs
4.03.9 Rig-up area Gas detector 24 pcs, H2S detector 18 pcs
Page 23 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
4.03.10 Drill floor Gas detector 10 pcs, H2S detector 7 pcs
4.03.11 Shale shaker room Gas detector 6 pcs, H2S detector 2 pcs
4.03.12 Pump room N/A
4.03.13 Air intake for safe areas Gas detector 84 pcs, H2S detector 23 pcs
Fire water pump system:
4.03.14
Riser piping frost protected and routed inside the superstructure to minimize the risk of
mechanical damage N
4.03.15 Automatic pressure release valve on fire water pumps Y
4.03.16 Automatic open/close of suction/discharge and overflow valves Y
4.03.17
Suction lines from sea chests provided with two valves, and one of the valves remotely
operated Y
4.03.18 Manual/remote activation from helideck Y
4.03.19 Manual/remote activation from main control center Y
Page 24 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
4.03.20 Manual activation locally at pump Y
4.03.21
Possible to stop system only from coinand centre, main control centre and locally at
pumps Y
Fire water ring main:
4.03.22
Pressure regulating devices installed at points where high pressure can be dangerous Y
Water deluge system:
4.03.23 Installed at areas for processing and conveying of hydrocarbons N
4.03.24 Installed at lifeboats Y
4.03.25 Installed at liferafts N
4.03.26 Installed at helifuel tanks foam
4.03.27 Installed at helifuel hose space N
4.03.28 Installed at structure exposed to flare-booms Y
4.03.29 Installed at flare-booms Y
4.03.30 Installed at drilling area Y
4.03.31 Separate connection to fire water ring main for sections covering drilling areas Y
4.03.32 Deluge system frost protected Y
4.03.33
Deluge valves located close to, but outside areas served by the valves, readily
accessible and close to escape routes Y
4.03.34
Pipework designed to ensure a uniform distribution of seawater over the protected
areas Y
4.03.35 The design ensures adequate drainage of the pipework Y
4.03.36 Local activation of deluge system possible Y
4.03.37 Sprinkler system in accomodation activated by heat sensitive frangible bulbs Y
Helideck fire extinguishing system:
4.03.38 Min. discharge (m3/h) 0.36
4.03.39 Range/monitor (ft) 72
4.03.40
Monitors supplied with a dedicated aqueous film forming foam (AFFF) or synthetic
compound AFFF
Other requirements:
4.03.54
Escape breathing masks of Statoil approved type (i.e. Drger Parat C) at each bed TBD
4.03.55
Radioactive sources and explosives to be stored seperately and easily available,
minimum 15m apart Y
4.03.56
Explosives stored at a location where easily available for removal overboard in an
emergency situation Y
4.03.57 Insulated handles on CO2 fire-fighting apparatus Y
4.03.58 Water monitors covering drill floor and accomodation area Y
4.04 HELICOPTER LANDING SYSTEM
4.04.1 Helideck designed for: S-61
4.04.2
Drainage system with sufficient capacity to enable draining of all fluid resulting from
the use of all fire extinguishers simultaneously on or near the helicopter/landing
system Y
Helicopter fuel system:
4.04.3 Pump capacity (G/min) 60
4.04.4 Fuel hose coupling of "single point" type for closed systems Y
Page 25 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
4.04.5 Designed for cold and hot refuelling Y
4.04.6 Operating temperature (oC) 45
4.04.7 Length of hose sufficient for refuelling anywhere on helideck Y
4.04.8 Equipped with API-approved filter seperator and a filter monitor of a type that
seperates solid particles and automatically stops the fuelling if the fuel contains water Y
4.04.9
Pressure gauge installed between the final filter (monitor) and the fuel hose reel.
Differential pressure gauge both on filter seperator and filter monitor Y
Page 26 of 27
REF.NO. ITEM TECHNICAL SPECIFICATION / DETAILS FOR RIG
IADC STANDARD EQUIPMENT LIST FORMAT - SEMI-SUBMERSIBLE DRILLING RIG
4.04.10 Transportable fuel tank connected to pump system via a flexible hose with stainless
steel armouring and a dust cover on the coupling when it is not connected Y
4.04.11
Non-return valve installed on the pressure side of fuel pump. If two pumps, both have
a seperate non-return valve Y
4.04.12 All components earthed Y
4.04.13 Permanent ladder on tanks with internal height exceeding 1400in Y
4.04.14
Meter on fuel system with reading in litres both for total amount and for each individual
refuelling. Resetting of meter possible Y
4.04.15 Helifuel back-up pump N
4.05 RESQUE AND SAFETY EQUIPMENT
Lifeboat stations:
4.05.1 Equipped with P.O.B.-lists, axes and knifes Y
4.05.2 Emergency lights also covering lifeboat winches Y
4.05.3 Protected against heat radiation from an ignited gas/fire blowout Y
4.05.4 Seperate davit for MOB-boat Y
Lifeboats/-rafts:
4.05.5 No. of covered lifeboats 4
4.05.6 Capacity each lifeboat 80 P
4.05.7 Capacity of each liferaft 25 P
Escape ways:
4.05.8
All clearly marked with luminous signs, and on deck, stairs etc. marked with paint
(width 80 cm) Y
4.05.9 Treated with non-skid material Y
4.05.10 Sufficent drainage in order to avoid water pools to occur Y
4.05.11 2 seperate escape ways from drillers cabin Y
4.05.12 Protected against heat radiation from an ignited oil/gas blowout Y
Other requirements:
4.05.13 Survival suits equipped with marking lights 170 P
4.05.14 Life jackets equipped with light reflecting stripes 320 P
4.05.15 Life buoys equipped with igniting light attachment and self-activating smoke signal 14
4.05.16 Chargeable emergency lights in corridors in living quarter Y
4.05.17 One mobile search light placed in moonpool area, and one in MOB-boat Y
4.05.18 All safety equipment clearly marked with illuminating materials Y
4.05.19 Derrickman escape chute Y
4.05.20 Passages and stairways provided with hand rails Y
4.05.21 All decks enclosed by safety railings Y
Page 27 of 27

S-ar putea să vă placă și