No Failure Class Problem Cause

1 Mechanical seal leaks mechanical seal drips Permukaan mating faces tidak rata
Permukaan mating faces meleleh
Spring rusak
O-ring sudah lama
Permukaan mating ring scratch
2 Shaft Pompa Sentrifugal Single Stage Bending shaft bend bearing rusak
impeller unbalance
improper sealing system
salah manufaktur
shaft patah crack
thermal stress
fatigue
3 Bearing Pompa
Remedy
ganti mechanical seal
ganti salah satu mating ring
ganti spring
ganti O-ring
ganti mating ring
ganti bearing, ganti shaft
ganti impeller, ganti shaft
perbaiki sealing system, ganti shaft
repair shaft
ganti shaft
ganti shaft
ganti shaft