Sunteți pe pagina 1din 6

KalkulasiBUNo1

PERHITUNGAN
BUNo

DATADATAHASILSURVEY
DiameterPipa
TebalPipa
InsideDiameter
Inletpressure
Outletpressure
Pressure,stdcondition
Temperaturestdcondition
Meantemperatureofline
Insidediameter
Pipelength
Gasrelativedensity(air=1)
Meangascompressibility
Pipelineefficiency
Meangasviscosity
Elevationofexitaboveentrance

20 "
12.7 mm=
19
15
10
1

"
bar
bar
bar

0.5 "
217.556607
145.037738
14.7
60
96.8

36 degC=
19
16000
0.6
0.9770995
0.9
8.000E06
0

KONDISIOPERASISAATINI
FlowRate

"
mtr=

lb/ftsec
feet

32,800,000 m3/bln
1,093,333 m3/day
38,610,702 SCFD

P1+P2=
P1xP2=

362.594345
31553.9182

183.71447 psig

1.2 Meangascompressibility

Z1=Pav*344400*10^(1.785G)
Z2=T^3.825
FaktorKompresibilitas

KalkulasiStudikasusKS.xlsxSheet2

7.45E+08
3.18E+10
0.9770995

HAL1/6

232.2866
159.7677
29.43
520
556.8

9.941939 mil

1 PARAMETERPERHITUNGAN
1.1
AveragePressure
1
1A
P

Pav=

psig=
psig=
psig=
drgF
drgF

psia
psia
psia
degR
degR

KalkulasiBUNo1

1.3 ReynoldNumber

Pb/Tb

0.0565962
=

1.524E+11

Re

4,121,435

3 TekananOperasimaksimumBerdasarkanMaterial

35,000 psig

0.5 in

0.4

20 in

specified minimum yield strength, psig


wall thickness, in
design factor from table 841.114A
longitudinal joint factor, table 841.115A
Temperature derating factor from table 841.116A
nominal outside diameter of pipe, in

Internal design pressure /(Maximum Operating Pressure):


= 700 psig
= 47.62 Bar
4 HitungQmaxberdasarkaMAOP
4.1 HitungKecepatanMaksimum

Z
R
T
G
P

0.9770995
10.73 ft3psia/lbmoleR
556.8 degR
0.6
714.70 psia

KecepatanMksimumyangdiijinkan,Umax=

KalkulasiStudikasusKS.xlsxSheet2

68.51 ft/sec

HAL2/6

KalkulasiBUNo1

4.2 HitungFlowrateMaksimumBerdasarkanKecepatanMaksimum

KecepatanOperasi(Uop)=
U
=
InsideDiaD=
Z1T1/P1=
Pb/Tb
U1*D^2/0.002122=

80% xKecepatanMaksimumygdiijinkan(Umax)
54.81158 ft/sec
19 in
0.76
0.056596154
9324684.683
Q
Qoperation

216,437,754 SCFD
38,610,702 SCFD

ReynoldNumber

23,103,285.52

HitungTekananKeluarDenganPersamaanAliranumum

Ft
F

23.37936413
21.04
=

KalkulasiStudikasusKS.xlsxSheet2

91.06010378

HAL3/6

KalkulasiBUNo1

GTLZ=

3,245.34
= 295,521.10
= (241,564.03)
TidakDapatdilaksanakankarenaTekananKeluar<0
5 HitungFlowrateMaksimumBerdasarkanTekananDownstreamMinimum
TekananDownstreamminimumsesuaidenganSyaratPenjualandenganPembeli
5.1 PersamaanUmumDenganPersamaanvonKarman
DilakukanPerhitunganSecaraIteratifdaripersamaanUMUM:
Q'(temporer)
=
Re

44,379,995
1.752E+11
4,737,268

= 20.83

18.74484418
GLTZ

3245.341082
=

2.959841622

Q= 44,379,995.5 SCFD
Qoperation=

38,610,702 SCFD

5.2 PersamaanUmumDenganFrictionFactorAGA
DilakukanPerhitunganSecaraIteratifdaripersamaanUMUM:
Q'(temporer)
48,846,373 SCFD
= 192,814,630,751
Re

D
e

5,214,024

19
0.0102 "
f=

0.017065
= 55.383
= 22.6574
= 48,846,373

KalkulasiStudikasusKS.xlsxSheet2

HAL4/6

KalkulasiBUNo1

5.3 PANHANDLEA
MenghitungFlowratemaksimumdenganPersamaanPanhandleA

AbaikanPerbedaanElevasi
E
0.9

22.15610794

3496.813336

3.096858347

= 59,985,596.12 SCFD

QOperation=

38,610,702.28 SCFD

5.4 PANHANDLEB
MenghitungFlowratemaksimumdenganPersamaanPanhandleB

AbaikanPerbedaanElevasi
E
0.9
18.71360004

3310.643741

2.994203205

QOperation=

KalkulasiStudikasusKS.xlsxSheet2

63,884,459.07 SCFD
38,610,702.28 SCFD

HAL5/6

KalkulasiBUNo1

5.4 PersamaanWeymoth
MenghitungFlowratemaksimumdenganPersamaanWeymoth

AbaikanPerbedaanElevasi
E
0.9
=

3245.341082

2.959841622

QOperation=

5.4 KESIMPULAN
PerhitunganFlowrate(Q)
KondisiOperasiSaatini
BerdasarMaksimumOperatingPressure(MAOP)
Pers.UmumDenganFaktortransmisivonKarman
Pers.UmumDenganFaktorFriksiAGA
PersamaanPanhandleA
PersamaanPanhandleB
PersamaanWeymouth

17.66904519

= 52,498,756.85 SCFD

38,610,702.28 SCFD

Peningkatan
38,610,702.28
216,437,754.19
44,379,995.46
48,846,373.12
59,985,596.12
63,884,459.07
52,498,756.85
63,884,459.07

KalkulasiStudikasusKS.xlsxSheet2

HAL6/6

SCFD
SCFD
SCFD
SCFD
SCFD
SCFD
SCFD

460.56%
14.94%
26.51%
55.36%
65.46%
35.97%
65.46%