CCSP can be used for port structures, river revetment, sewerage, earth retaining walls and many other uses. Because of therr corrugated cross section,CCSP have better capabilities and are cheaper than conventional steel sheet piles.
CCSP can be used for port structures, river revetment, sewerage, earth retaining walls and many other uses. Because of therr corrugated cross section,CCSP have better capabilities and are cheaper than conventional steel sheet piles.
CCSP can be used for port structures, river revetment, sewerage, earth retaining walls and many other uses. Because of therr corrugated cross section,CCSP have better capabilities and are cheaper than conventional steel sheet piles.
PRAGTTGAL, EGONOMI.CAL & EXTREMELY RELIABLE Manufacturer: JHS Grlr*iEr,il PT.Saeti Goncretindo Walrana PT.Saeti Beton Pracetak (Jakarta) (Surabaya) I P.G. CORRUGATED SHEET PILES FOR SOIL RETAINING STRUCTURE coNcRETE GORRUGATED SHEET P|LE (CGSP) Prestressed Concrete Corrugated Sheet Piles (CCSP) can be used for port structures, river revetment, sewerage, earth retaining walls and many other uses and were developed as a substitute for steel sheet piles. Because of therr corrugated cross section,CCSP have better capabilities and are cheaper than conventional steel sheet piles.ln particular, corrugated sheet piles perform at their best when being driven in; they can be placed with greater accuracy. Many users are already using CCSP and their excellent performance has been highly appreciated. These piles will satisfy for all structural demands. ADVANTAGES OF CONGRETE CORRUGATED SHEET P|LE (CCSP) 1. High Strength and high quality. 2. High performance and economics. 3. Large CCSP can be manufactured 4. Completely free from rust and corrosion; make them useable even in marine structures. 5. Can be made watertight. 6. Excellent workability. 7. High driving accuracy. 8. Small displacement (deflection) at the head of sheet piles. 1 w-325 A 1000 w-325 B 1000 325 110 996 0.329 11.40 1 3.81 tlltt IIIII 2 w-350 A 1000 w-350 B 1000 350 't20 996 0.367 16.46 19 26 ;IIIII rr- 3 w-400 A 1000 w-400 B 1000 400 120 996 0.400 21.63 23.35 Ll l l I l lrr r r r 4 w-450 A 1000 w-450 B 1000 450 120 996 0.459 26.69 31.91 I w-500 A 1000 w-500 B 1000 500 120 996 0.455 34.66 41 .O3 IIIII I TTTtrI L 6 w-600 A 1000 w-600 B 1000 600 120 996 0.520 51.14 58.83 Illlll I IIIIII L I ffi Section - A '(6F-EndSectioO- Notes: '1 . Concrete Compressive Strength at 28 days is 700 kg/Cm2 (Cube test) 2. Strand Grade : Uncoated s6ven wire strands Grade 270 (ASTIV A416-99) 3. Sheet piles can be custom made to meet client's design criteria J HS sf,. Section - B (Middle Section) PT.Saeti Goncretindo Wahana PT.Saeti Beton Pracetak Jakarta) Surabaya) td ffi wil Lindeteves Trade Center Retaining Wall JHS Cideng River Normalization