Sunteți pe pagina 1din 2

FLOW STRAIGHTENER

FOR VORTEX FLOW METERS


DESCRIPTION
The optional fow straightener accessory for ONICON
F-2000 Series Vortex Flow Meters is a wafer-style fow
conditioner that is designed to be installed between two
ANSI Class 300 fanges (provided by installer) that are
located a specifed distance upstream of the fow meter.
Use of a fow straightener signifcantly reduces the
upstream straight pipe length requirement for ONICON
Vortex Flow Meters.
The size of the straightener should always match the
meter size (as opposed to the original pipe size).
The fow straightener is made of 304/A 351 CF8
Stainless Steel.
1500 North Belcher Road, Clearwater, Florida 33765 (727) 447-6140 (727) 442-5699 fax
www.onicon.com sales@onicon.com
SIZE DIM A DIM B DIM C DIM D NUMBER OF
HOLES
2 3.93 1.0625 .28 2.14 35
3 5.31 1.0625 .43 3.24 35
4 6.26 1.0625 .55 4.22 35
6 8.50 1.0625 .78 6.07 35
8 10.62 1.0625 1.02 7.98 35
10 13.23 1.0625 1.30 10.02 35
12 15.00 1.0625 1.53 12.00 35
TABLE 1 - ALL DIMENSIONS SHOWN IN INCHES
SERRATIONS SHOWN LOCATED UNDER GASKET, IF PROVIDED
NOTE: DIMENSION D INDICATES I.D. FOR SERRATIONS
GASKET THICKNESS, NOMINAL
DIM B
DIM D DIM A
DIM C
0.125
0497-3 01-12
F-2000 SERIES STEAM FLOW METER WITH FLOW STRAIGHTENER INSTALLATION DETAIL
OBSTRUCTION
SEE TABLE 1
UPSTREAM
NOTES:
1) CONSULT MANUFACTURER FOR METER SIZE AND APPLICABLE
2) PROVIDE ECCENTRIC REDUCER AND EXPANDER WHEN REQUIRED.
3) PROVIDE FLOW STRAIGHTENER WHEN REQUIRED TO MEET
TO MANUFACTURER'S RECOMMENDATIONS.
METER PIPE RUN FOR EACH APPLICATION. INSTALL ACCORDING
RECOMMENDED MINIMUM UPSTREAM PIPE RUN REQUIREMENTS.
SINGLE 90
MINIMUM UPSTREAM PIPE RUN REQUIRED
STRAIGHTENER STRAIGHTENER
UPSTREAM
TEE
RDCR/EXPNDR
TWO 90'S
BALL/GATE VALVE
TW0 90'S
CONTROL
P.R.V.
SAME PLANE
FULLY OPEN
OUT OF PLANE
VALVE
WITH FLOW WITH FLOW
OBSTRUCTION
12 DIA 10 DIA
12 DIA 10 DIA
12 DIA 10 DIA
17 DIA 15 DIA
17 DIA 15 DIA
22 DIA 20 DIA
27 DIA 25 DIA
27 DIA 25 DIA
TABLE 1
DIMENSION B 2 DIAMETERS 5 DIAMETERS
ONICON F-2000 SERIES STEAM METER, NOTE 1
300# ANSI FLANGE
ECCENTRIC REDUCER, NOTE 2
FLOW STRAIGHTENER, NOTE 3
(600# ANSI FLANGE OPTNL)
11-22-04 B.D.
F-2000 SERIES STEAM FLOW METER
N.T.S. 041124BD-1
INSTALLATION DETAIL
MINIMUM UPSTREAM PIPE RUN
MINIMUM DOWNSTREAM PIPE RUN
DIMENSION B
REQUIRED DIMENSIONS FOR INSTALLATIONS WITH FLOW STRAIGHTENER
UPSTREAM
OBSTRUCTION
DIMENSION A DIMENSION B
TOTAL UPSTREAM
PIPE RUN
DISTANCE BETWEEN
FLOW METER AND STRAIGHTENER
SINGLE 90 12 DIA 10 DIA
TEE 12 DIA 10 DIA
RDCR/EXPNDR 12 DIA 10 DIA
TWO 90S SAME PLANE 17 DIA 15 DIA
BALL/GATE VALVE FULLY OPEN 17 DIA 15 DIA
TWO 90S OUT OF PLANE 22 DIA 20 DIA
CONTROL VALVE 27 DIA 25 DIA
PRV 27 DIA 25 DIA
NOTES
1. Consult ONICON for meter size and applicable meter pipe run for each application. Install according to
manufacturers recommendations.
2. Provide eccentric reducer and expander when required.
3. Provide fow straightener when required to meet recommended minimum upstream pipe run requirements.
4. Flanges provided by contractor. Center straightener between fanges during installation.
DIMENSION A
Pressure Loss for Flow Straightener
PRESSURE LOSS CHART FOR
FLOW STRAIGHTENER
(inch)
1 1

2 3 4 6 8 1
0
1
2
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
1000
500
200
100
50
20
10
5
2
1
P:
c :
Pressure loss in psi
Density(lb/ft)
Pressure loss coefficient
:
P
r
e
s
s
u
r
e

l
o
s
s

c
o
e
f
f
.

o
f

l
i
q
u
i
d

(
C
)
P
r
e
s
s
u
r
e

l
o
s
s

c
o
e
f
f
.

o
f

g
a
s

a
n
d

s
t
e
a
m

(
C
)
Liquid (GPM)
Nominal size
Gas and steam
(ft/min)
Flow rate
10-09-08 0570
1500 North Belcher Road, Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699
www.onicon.com E-mail: sales@onicon.com
0.023232
4.4 8.8 22 44 88 220 440 880 2200 4400 8800
6 12 30 60 120 300 600 1,200 3,000 6,000 12,000
PRESSURE LOSS CHART FOR
FLOW STRAIGHTENER
(inch)
1 1

2 3 4 6 8 1
0
1
2
10
5
2
1
0.5
0.2
0.1
0.05
0.02
0.01
1000
500
200
100
50
20
10
5
2
1
P:
c :
Pressure loss in psi
Density(lb/ft)
Pressure loss coefficient
:
P
r
e
s
s
u
r
e

l
o
s
s

c
o
e
f
f
.

o
f

l
i
q
u
i
d

(
C
)
P
r
e
s
s
u
r
e

l
o
s
s

c
o
e
f
f
.

o
f

g
a
s

a
n
d

s
t
e
a
m

(
C
)
Liquid (GPM)
Nominal size
Gas and steam
(ft/min)
Flow rate
10-09-08 0570
1500 North Belcher Road, Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699
www.onicon.com E-mail: sales@onicon.com
0.023232
4.4 8.8 22 44 88 220 440 880 2200 4400 8800
6 12 30 60 120 300 600 1,200 3,000 6,000 12,000
1500 North Belcher Road, Clearwater, FL 33765 Tel (727) 447-6140 Fax (727) 442-5699
www.onicon.com sales@onicon.com
0497-3
01-12

S-ar putea să vă placă și