This document provides information on wind load design for diaphragms according to the 2009 International Building Code. It includes wind loads, shear values, moments, and chord forces for longitudinal and transverse diaphragms. It also specifies nailing schedules and allowable load values for 15/32 inch and 19/32 inch wood structural panel sheathing.
This document provides information on wind load design for diaphragms according to the 2009 International Building Code. It includes wind loads, shear values, moments, and chord forces for longitudinal and transverse diaphragms. It also specifies nailing schedules and allowable load values for 15/32 inch and 19/32 inch wood structural panel sheathing.
This document provides information on wind load design for diaphragms according to the 2009 International Building Code. It includes wind loads, shear values, moments, and chord forces for longitudinal and transverse diaphragms. It also specifies nailing schedules and allowable load values for 15/32 inch and 19/32 inch wood structural panel sheathing.
Diaphragm W trans = 230 plf Offset x f t 5 3 L long: 77 ft Moment long =W * L long 2 /8 Tension long =M long /L trans Boundary W Length Length Shear Moment Chord Offset x LONG TRANS LONG LONG At Offset Force FT PLF FT FT PLF # -FT LBS Boundary 0 230 53 77 79 0 0 Offset 0 230 53 77 79 0 0 Offset 0 230 53 77 79 0 0 Offset 0 230 53 77 79 0 0 L trans /2 27 230 0 77 0 80759 1049 Boundary W Length Length Shear Moment Chord Offset x TRANS LONG TRANS TRANS At Offset Force FT PLF FT FT PLF # -FT LBS Boundary 0 230 77 53 167 0 0 Offset 0 230 77 53 167 0 0 Offset 0 230 77 53 167 0 0 Offset 0 230 77 53 167 0 0 L long /2 39 230 0 53 0 170459 3216 Chord Design: Maximum Chord Force= 3216 lbs 15/32 Sheathing w/ 8d ZONE Nailing Load Wind* Seismic A 6-6 180 232 166 B 4-6 360 464 331 C 2.5-4 530 683 488 D 2-3 600 773 552 *Allowable wind loads have been adjusted for increase by 40% per IBC section 2306.3.2 Load reduction for Wood Species Specific Gravity Adjustment factor. Adj Factor=[1-(0.5-SG)] SG=0.42 19/32 Sheathing w/ 10d ZONE Nailing Load Wind* Seismic A 6-6 320 412 294 B 4-6 425 547 391 C 2.5-4 720 927 662 D 2-3 820 1056 754 *Allowable wind loads have been adjusted for increase by 40% per IBC section 2306.3.2 Load reduction for Wood Species Specific Gravity Adjustment factor. Adj Factor=[1-(0.5-SG)] SG=0.42 DIAPHRAGM SHEAR & CHORD DESIGN B o u n d a r D1 Diaphragm W long = L t r a n s : 230 plf SECTION Fastener Zone Roof LONGITUDINAL DIAPHRAGM SECTION Fastener Zone Roof A A A A A TRANSVERSE DIAPHRAGM 2x Blocked A A A A A Framing Member Notes 2x UnBlocked 2x Blocked 2x Blocked Framing Member Notes 3x Blocked 3x Blocked 3x Blocked 3x Blocked