Sunteți pe pagina 1din 1

Wood Beam

ENERCALC, INC. 1983-2011, Build:6.11.6.23, Ver:6.11.6.23


Licensee : Lic. # :
File: P:\7) Boccella Residence\Calculations\Enercalc\ROOF BEAMS.ec6
Description : RB16 CB
Material Properties
Beam Bracing :
Calculations per NDS 2005, IBC 2009, CBC 2010, ASCE 7-05
Completely Unbraced
Allowable Stress Design
Douglas Fir - Larch
No.1
1,350.0
1,350.0
925.0
625.0
1,600.0
580.0
170.0
675.0 32.210
Analysis Method :
Eminbend - xx ksi
Wood Species :
Wood Grade :
Fb - Tension
psi
psi
Fv psi
Fb - Compr
Ft psi
Fc - Prll psi
psi Fc - Perp
E : Modulus of Elasticity
Ebend- xx ksi
Density pcf
Load Combination :2009 IBC & ASCE 7-05
6x10
Span =8.0 ft
D(0.36) Lr(0.45)
D(0.028) Lr(0.04)
D(0.12)
D(0,0.056) Lr(0,0.08)
D(0.056,0) Lr(0.08,0)
Applied Loads
Service loads entered. Load Factors will be applied for calculations.
Beam self weight calculated and added to loads
Uniform Load : D = 0.0140, Lr = 0.020 ksf, Tributary Width = 2.0->0.0 ft, (ROOF)
Uniform Load : D = 0.0150 ksf, Tributary Width = 8.0->0.0 ft, (WALL ABOVE)
Varying Uniform Load : D(S,E) = 0.0->0.0140 ksf, Extent = 0.0 -->> 4.0 ft, Trib Width = 4.0->0.0 ft, (HIGHER ROOF)
Varying Uniform Load : D(S,E) = 0.0140->0.0, Lr(S,E) = 0.020->0.0 ksf, Extent = 4.0 -->> 8.0 ft, Trib Width = 4.0->0.0 ft, (HIGHER ROOF)
Point Load : D = 0.360, Lr = 0.450 k @4.0 ft, (FR RB15-RIGHT)
DESIGN SUMMARY Design OK
Maximum Bending Stress Ratio 0.381: 1
Load Combination +D+0.750Lr+0.750L+H
Span # where maximum occurs Span # 1
Location of maximum on span 4.000ft
34.08psi =
=
FB : Allowable 1,345.87psi Fv : Allowable
6x10
Section used for this span
Span # where maximum occurs
Location of maximum on span
Span # 1 =
Load Combination +D+0.750Lr+0.750L+H
=
=
=
170.00psi = =
Section used for this span
6x10
fb : Actual
Maximum Shear Stress Ratio 0.200 : 1
7.240ft =
=
512.20psi fv : Actual
Maximum Deflection
0 <240
1448
Ratio = 0 <180
Max Downward L+Lr+S Deflection 0.027 in 3586 Ratio =
Max Upward L+Lr+S Deflection 0.000 in
Ratio =
Max Downward Total Deflection 0.066 in
Ratio =
Max Upward Total Deflection 0.000 in
Location in Span Load Combination Max. "-" Defl Location in Span Load Combination Span Max. "+" Defl
Overall Maximum Deflections - Unfactored Loads
D+Lr 1 0.0663 4.040 0.0000 0.000
Load Combination Support 1 Support 2
Vertical Reactions - Unfactored
Support notation : Far left is #1 Values in KIPS
Overall MAXimum 1.476 1.476
D Only 0.931 0.931
Lr Only 0.545 0.545
D+Lr 1.476 1.476