Sunteți pe pagina 1din 16

Users

Manual
FSA120
Flow Confguration Software
Getting Started
IM 01C25R51-10E
IM 01C25R51-10E
8th Edition
CONTENTS
PART A (English version)
1. Components
2. To Start with
3. Installation Flow
4. Important Notice on Flow Confguration Wizard
5. Software Version
6. Information Provision Web Site
Appendix A Flow Parameters Download Procedure
Appendix B Flow confguration for EJX910A/EJX930A HART 7 model
PART B (Japanese version)

Revision Information
R1.05
<A1. Header> 2
IM 01C25R51-10E
PART A
Thank you for purchasing FSA120 Flow Confguration Software.
This document is intended to guide users what to do after receiving the software package.
Please carefully read this document frst when you receive the package and follow the instructions.
1. Components
The following picture shows the items included in the FSA120 package.
FieldMate (bundled)
CD-ROM DVD-ROM
FieldMate
CD-ROM
FlowNavigator
FSA120
USB FieldMate Modem (Option)
Device Files
License Number
Sheet
FieldMate
Paper Document
FieldMate
License Number
Sheet
FlowNavigator
Disc No.1
Disc No.3
Disc No.2 License Sheet No.1 Document No.1 and No.2
License Sheet No.2
Paper Document
FlowNavigator
Document No.3 and No.4
F01E.ai
FlowNavigator
Figure 1 Components of FSA120
Each disk contains the following software.
CD-ROM/DVD-ROM: 3 discs
(1) FieldMate <Disc No.1>
(2) Device Files (Includes Device DTM*) <Disc No.2>
*: Device DTM is delivered by Yokogawa DTMLibrary HART/FOUNDATION feldbus
(3) FlowNavigator (Includes FlowNavigator Program and Resource) <Disc No.3>
License Sheet: 2 sheets
(1) FieldMate License Number Sheet (Basic or Advance, as specifed in order) <License Sheet No.1>
(2) FlowNavigator License Number Sheet <License Sheet No.2>
Paper Document: 4 sheets
(1) FieldMate Getting Started (IM 01R01A04-01E) <Document No.1>
(2) FieldMate Operational Precaution (IM 01R01A01-91E) < Document No.2>
(3) FlowNavigator Getting Started (IM 01C25R51-10E) < Document No.3>[This document]
(4) FlowNavigator License Agreement <Document No.4>
USB FieldMate Modem (Option)
<A1. Header> 3
IM 01C25R51-10E
NOTE
For FSA120 R1.04 or later, the product name has been changed to FieldMate FlowNavigator because the DYFMVTool
program for digitalYEWFLO Vortex Flowmeter has been added.
Consequently, the following items have been renamed accordingly:
<Disc No.3>:
EJXMVTool Additional resource disk FlowNavigator CD-ROM
<License Sheet No.2>:
EJXMVTool License Number Sheet FlowNavigator License Number Sheet
<Document No.3>:
EJXMVTool Read Me First FlowNavigator Getting Started
<Document No.4>:
EJXMVTool License Agreement FlowNavigator License Agreement.
NOTE
The location of following software has been changed for FSA120 R1.04 or later.
Device Files DVD-ROM <Disc No.2>:
FlowNavigator program has been moved from Yokogawa DTMLibrary HART/FOUNDATION feldbus in Device Files DVD-
ROM to FlowNavigator CD-ROM
FlowNavigator CD-ROM <Disc No.3>:
In addition to Resource, the FlowNavigator program (EJXMVTool and DYFMVTool) has been added.
2. To Start with
1) FlowNavigator is the software utilizing FDT/DTM technology. To use this software, a frame application is required. Field
Mate is bundled with this software package as Yokogawa standard frame application. The quality and operability of
FlowNavigator is certifed for use with FieldMate only. Please use Field Mate as frame application. Also, you can use Field
communication server included in FieldMate as a Communication DTM. For the installation and operation of FieldMate,
please refer to the printed document
FieldMate Getting Started (IM 01R01A04-01E) < Document No.1>
FieldMate Operational Precaution (IM 01R01A01-91E) < Document No.2>
For the details of installation and operation, please also refer to the users manual of FieldMate in pdf format shown by start
menu.
2) Before starting any operation, please carefully read the instructions in the users manual of FlowNavigator and obtain nec-
essary knowledge about installation and operation of the software.
The Users manual FSA120 Flow Confguration Software (IM 01C25R51-01E) is provided as a Portable Document For-
mat (pdf) fle in the CD-ROM labeled FlowNavigator, and is located at
<FlowNavigator CD-ROM>: \EJXMVTool_Manual.pdf
<FlowNavigator CD-ROM>: \DYFMVTool_Manual.pdf
Set the FlowNavigator CD-ROM in the CD-ROM drive of your computer and double click the name of the fle.
To read the fle in pdf format, Adobe Reader is required.
If Adobe Reader is not on your PC, download and install Adobe Reader from the following website.
<http://www.adobe.com/>
<A1. Header> 4
IM 01C25R51-10E
3. Installation Flow
Followings are the fow of standard installation. As the procedures may differ according to the condition, please fnd details in
each designated manual and follow the instructions.
Step 1 Confrm incompatible software does not exist, PRM and FSA210 (Refer to < Document No.2>)
Step 2 Install communication device software (For FOUNDATION feldbus communication)
Step 3 Install FieldMate (Refer to <Document No.1>)
1) Install FieldMate <Disc No.1 >
2) Enter the license number of FieldMate <License Sheet No.1 >
3) Install Device Files <Disc No.2 >
Step 4 Install FlowNavigator <Disc No.3 >
Step 5 Start FieldMate
1) Register yourself in FieldMate (Refer to <Document No.1>)
2) Start Device DTM
Step 6 Start FlowNavigator Program
1) Enter the license number of FlowNavigator <License Sheet No.2 >
4. Important Notice on Flow Confguration Wizard
Supplemental explanation regarding Apply button
When you click the Apply button, the fow parameters are temporarily saved to an offine database on your PC. To down-
load the fow parameters to the device, set Download to Device in the Offine Parameter screen.
For basic information on the procedure for downloading fow parameters to the device, refer to Appendix A.
Supplemental explanation for EJX910A/EJX930A HART 7 model
Flow parameter confguration by FlowNavigator can be done by EJX910 V2.1 DTM.
Refer to Appendix B.
<A1. Header> 5
IM 01C25R51-10E
5. Software Version
Following is the information of the software version of the package and each software included in the package. For the latest
information of software version/revision, please see the web site of FieldMate.
For how to confrm version/revision of the software, please refer to the subsection 4.2.6 of IM 01C25R51-01E.
FSA120
package
Additional
Resource Disk
FieldMate
Yokogawa
DTM Library
(Device Files*)
EJX910DTM
R1.02.00 R1.02.00 R1.02.10 HART 2006-3
FOUNDATION feldbus
2006-1
HART EJX910V1.1 1.4.124.19
FOUNDATION feldbus
EJX910V1.2 1.1.15.14
R1.02.01 R1.02.01** R1.02.10 HART 2006-3
FOUNDATION feldbus
2006-1
HART EJX910V1.1 1.4.124.19
FOUNDATION feldbus
EJX910V1.2 1.1.15.14
R1.02.02 R1.02.02 R1.03.00 HART 2008-1
FOUNDATION feldbus
2008-1
(R1.01.00)
HART EJX910V1.1 1.4.124.16
FOUNDATION feldbus
EJX910V1.2 1.2.64.89
R1.03.00 R1.03.00 R2.01.00 HART 2008-3
FOUNDATION feldbus
2008-3
(R2.01.00)
HART EJX910V1.1 1.4.124.16
FOUNDATION feldbus
EJX910V1.2 1.2.81.108
EJX910V2.1 1.2.81.108
FSA120
package
FlowNavigator
Disk
FieldMate
Yokogawa
DTM Library
(Device Files*)
Device DTM
R1.04.00 R1.04.00 R2.02.00 HART 2010-1
FOUNDATION feldbus
2010-1
(R3.01.00)
EJX910 HART:
EJX910V1.1 1.4.124.16
EJX910V2.1 1.4.160.18
EJX910 FOUNDATION feldbus:
EJX910V1.2 1.2.81.108
EJX910V2.1 1.2.81.108
DYF(SoftDL) FOUNDATION feldbus:
DYF(SoftDL) V3.1 1.2.81.108
R1.05.00 R1.05.00 R2.04.00 HART 2011-3
FOUNDATION feldbus
2011-4
(R3.03.00)
EJX910 HART:
EJX910V1.1 1.4.124.16
EJX910V2.1 1.4.160.27
EJX910 FOUNDATION feldbus:
EJX910V1.2 1.2.81.108
EJX910V2.1 1.2.81.108
DYF(SoftDL) FOUNDATION feldbus:
DYF(SoftDL) V3.1 1.2.81.108
*: Compatibility between FieldMate and Device Files is indicated at the following URL.
https://voc.yokogawa.co.jp/PMK/Top.do
**: The version number on the CD-ROM shows R1.02.01.
On the other hand, the version number on the Add/ remove program screen of Windows Control Panel remains to show
R1.02.00 even if the update fles are installed.
To confrm whether the latest EJXMVTool R1.02.01 is correctly installed in your PC, please check the version number of
Flow Confguration Wizard. Refer to 6.2.5 in IM 01C25R51-01E.
<A1. Header> 6
IM 01C25R51-10E
6. Information Provision Web Site
For FieldMate and/or PRM users, the users web site has been already in operation as follows:
https://voc.yokogawa.co.jp/PMK/Top.do
The FlowNavigator category within the above web site provides the latest software operation environment supporting
information such as documents and update programs.
After registration as a FieldMate user, you can fnd the Download FlowNavigator menu by clicking the information icon on
the top menu. Entering your FSA120 license number allows you to access the information menu for FlowNavigator.
Appendix A Flow Parameters Download Procedure
The basic procedure for downloading the fow parameters to a device is as follows. Refer to Figure A-1, A-2.
Step1 Upload from Device
Perform Upload from Device so that the setting parameters (Device Flow Parameters and Device General Parameters) in
the device are saved to the offine database on your PC.
The parameters will then be displayed in the Offine Parameter screen.
Step2 Flow Confguration
Perform Flow confguration in accordance with the guidance in the Flow Confguration Wizard. Device Flow Parameters are
output by Flow Confguration Wizard.
Save Device Flow Parameters as XMV fle (EJXMVTool) or VMV fle (DYFMVTool) in the last menu, and click the Apply
button.
Device Flow Parameters are then stored to the offine database on your PC.
NOTE
Clicking on Apply does not download the fow parameters to the device.
Step3 Download to Device
Perform Download to Device. Device Flow Parameters will then be downloaded together with the Device General
Parameters to the device.
<A1. Header> 7
IM 01C25R51-10E
IMPORTANT
For FOUNDATION Fieldbus, following block must be checked on the Download blocks menu in the Offine Parameter screen
to download Device Flow Parameters set by Flow Confguration Wizard.
EJX910 FOUNDATION feldbus DTM: FTB block
DYF(SoftDL) FOUNDATION feldbus DTM: AR block
Download blocks menu
(EJX910 FOUNDATION fieldbus DTM)
Download blocks menu
(DYF(SoftDL) FOUNDATION fieldbus DTM)
Figure A-1 Download blocks menu in the Offine Parameter
Offline Parameter Flow Configuration Wizard Offline Parameter
Offline
Database
Offline
Database
Offline
Database
Step 1 Step 2 Step 3
Device General Parameters (Default value: , Configured value: )
Device Flow Parameters (Default value: , Configured value: )
*: Confirm the checkbox on the Download blocks menu in the Offline Parameter (refer to Figure A-1)
*
Figure A-2 Procedure to Download the Parameters to the Device
<A1. Header> 8
IM 01C25R51-10E
Appendix B Flow confguration for EJX910A/EJX930A
HART 7 model
Flow confguration for EJX910A/EJX930A HART 7 model is shown below.
Open Segment Viewer on FieldMate.
A device icon appears on the window if it is successful to connect to FieldMate.
Figure B-1 Segment Viewer
Select the icon of the target device.
Click the [Action] [Select DTM]
Select EJX910 V2.1 DTM and click OK.
Figure B-2 Select EJX910 V2.1 DTM
For the following operations, perform in the same procedure as the fow confguration for EJX910A/EJX930A HART 5 model.
<A1. Header> 9
IM 01C25R51-10E
NOTE
FlowNavigator works on following Device DTM.
Device DTM Name (EJX910 HART DTM)
Device DTM EJX Multivariable Transmitter
Name Model Name HART Protocol
Revision
Device Type Device Revision
EJX910 V1.1
EJX910A
EJX930A
5
EJX910
(0x0054)
1
EJX910 V2.1 EJX910
(0x0054)
2
EJX910 V2.1* 7 EJX910
(0x3754)
10
*: For EJX910A/EJX930A HART 7 model, EJX910 V2.1 DTM is used for FlowNavigator.
NOTE
Use the device DTM EJX910 V2.1 for EJX910A/EJX930A HART 7 model. EJX910 V2.1 is a DTM which corresponds to
EJX910A/EJX930A HART 5 model (Device revision 2). Flow parameter confguration by FlowNavigator can be done by this
DTM.
NOTE
General parameter confguration for EJX910A/EJX930A HART 7 model (Device revision 10) can be done by EJX910
HART7 DTM. When starting FieldMate for EJX910A/EJX930A HART 7 model, EJX910 HART7 DTM is automatically
assigned by default. So when using FlowNavigator, select EJX910 V2.1 DTM manually.
<A1. Header> 10
IM 01C25R51-10E
PART B

1.
2.
3.
4.
5.
6.
1.
2. EJX910A/EJX930A HART 7
FSA120

1.
FSA120
lieldMale]|)
o.1 o.z }`.' o.1 '-`' o.1, o.z
CLROM
lieldMale
L\LROM
Levice liles
}`
.'
lieldMale
['-`'
lieldMale
o.:
CLROM
llowaviqalor
}`.' o.z '-`' o.:, o.4
}`
.'
llowaviqalor
['-`'
llowaviqalor
lSA1z0
SB lieldMale 1.`)
F01.ai
llowaviqalor
1 FSA120
<A1. Header> 11
IM 01C25R51-10E

CD-ROM/DVD-ROM3
(1) FieldMate < No.1>
(2) Device Files (DTM*) < No.2>
*: DTMYokogawa DTMLibrary HART/FOUNDATION feldbus
(3) FlowNavigator (FlowNavigator) < No.3>
2
(1) FieldMateBasicAdvance
< No.1>
(2) FlowNavigator < No.2>
4
(1) FieldMate Getting StartedFieldMate
(IM 01R01A04-01E) <No.1>
(2) FieldMate Operational Precaution(IM 01R01A01-91E) < No.2>
(3) FlowNavigator Getting StartedFSA120
(IM 01C25R51-10E) < No.3>
(4) FlowNavigator< No.4>
USB FieldMate
2.
1) FlowNavigatorFDT/DTM
Field Mate
FlowNavigatorFieldMateFieldMate
DTMFieldMate
FieldMate
FieldMate Getting StartedFieldMate
(IM 01R01A04-01E) < No.1>
FieldMate Operational Precaution(IM 01R01A01-91E) < No.2>
pdfFieldMate

2) FlowNavigator

FSA120IM 01C25R51-01JAFlowNavigator CD-


ROM pdf
<FlowNavigator CD-ROM>: EJXMVTool_Manual.pdf
<FlowNavigator CD-ROM>: DYFMVTool_Manual.pdf
FlowNavigatorCD-ROMPCCD-ROM pdf
Adobe ReaderAdobe ReaderPC

http://www.adobe.com/
3.

Step 1

( <No.2>)
<A1. Header> 12
IM 01C25R51-10E
Step 2
FOUNDATION
Step 3 FieldMate (<No.1>)
1) FieldMate <No.1>
2) FieldMate <No.1>
3) Device Files < No.2>
Step 4 FlowNavigator < No.3>
Step 5 FieldMate
1) FieldMate
( < No.1>)
2) DTM
Step 6 FlowNavigator
1) FlowNavigator<No.2>
4.
Apply
[Apply]PC

1
EJX910A/EJX930A HART 7
FlowNavigatorEJX910 V2.1DTM2

5.
/
FieldMate
/IM 01C25R51-01JA 4.2.6

FSA120

FlowNavigator

FieldMate
Yokogawa
DTM Library
(Device Files*)
DTM
R1.05.00 R1.05.00 R2.04.00 HART 2011-3
FOUNDATION feldbus
2011-4
(R3.03.00)
EJX910 HART:
EJX910V1.1 1.4.124.16
EJX910V2.1 1.4.160.27
EJX910 FOUNDATION :
EJX910V1.2 1.2.81.108
EJX910V2.1 1.2.81.108
DYF(SoftDL) FOUNDATION
:
DYF(SoftDL) V3.1 1.2.81.108
*FieldMateDevice Files
https://voc.yokogawa.co.jp/PMK/Top.do
<A1. Header> 13
IM 01C25R51-10E
6.
FieldMatePRM
https://voc.yokogawa.co.jp/PMK/Top.do
FlowNavigator

FieldMate[][FlowNavigator]
FlowNavigatorFlowNavigator

1.
1.2
Step 1
PC

Step 2

XMV(EJXMVTool)VMV(DYFMVTool)
ApplyPC

Apply
Step 3

<A1. Header> 14
IM 01C25R51-10E

FOUNDATION
Download blocks
EJX910 FOUNDATIONDTMFTB
DYF(SoftDL) FOUNDATIONDTMAR
Download blocks .
(EJX910 FOUNDATION '' DTM)
Download blocks .
(DYF(SoftDL) FOUNDATION '' DTM)
1.1 Download blocks
` ' `
`
^
`
^
`
^
Step 1 Step 2 Step 3
],[''j,j@)
],''j,j)
`'Lownload blocks _[[|(J']1.1,|)
*
1.2
<A1. Header> 15
IM 01C25R51-10E
2. EJX910A/EJX930A HART 7
EJX910A/EJX930A HART 7
FieldMate
FieldMate
2.1

[] [DTM]
EJX910 V2.1 DTMOK
2.2 EJX910 V2.1 DTM
EJX910A/EJX930A HART 5
<A1. Header> 16
IM 01C25R51-10E

FlowNavigator DTM
DTMEJX910 HART DTM
DTM EJX

HART


EJX910 V1.1 EJX910A
EJX930A
5 EJX910
(0x0054)
1
EJX910 V2.1 EJX910
(0x0054)
2
EJX910 V2.1* 7 EJX910
(0x3754)
10
* EJX910A/EJX930A HART 7 FlowNavigator EJX910 V2.1 DTM

EJX910A/EJX930A HART 7 DTM EJX910 V2.1 EJX910 V2.1


EJX910A/EJX930A HART 5 ( 2) DTM FlowNavigator
DTM

EJX910A/EJX930A HART 7 ( 10) EJX910 HART 7 DTM


EJX910A/EJX930A HART 7 FieldMateEJX910 HART 7 DTM
FlowNavigator EJX910 V2.1 DTM
Revision Information
January 2007/1st Edition Newly published.
April 2007/2nd Edition Add Important notice regarding fow confguration wizard.
August 2007/3rd Edition Delete Important notice regarding the setting of External temperature and Pressure.
Add the additional installer to update R1.02.00 to R1.02.01.
February 2008/4th Edition Add VI. Information Provision web Site for EJXMVTool
Revise the information of FieldMate components.
Delete the additional installer to update R1.02.00 to R1.02.01
December 2008/5th Edition Add the latest revision information for FSA120 due the release of FieldMate R2.
June 2010/6th Edition Full-fedged revision because of adding the DYFMVTool program for digitalYEWFLO
Vortex Flowmeter and change of the product name to FieldMate FlowNavigator.
September 2011/7th Edition Add supplemental explanation for EJ910A/EJX930A HART protocol revision 7 model.
Correspond to R1.05.
Display image is showed in Windows 7 environment.
Add PART B (Japanese version)
August 2012/8th Edition Add the USB FieldMate Modem as option.

S-ar putea să vă placă și