Documente Academic
Documente Profesional
Documente Cultură
Smartpack
356807.063
ii
, ,
, Eltek Energy.
,
( ,
), ,
Eltek Energy.
PowerSuite
PowerSuite
PowerSuite Online Help System, 356807.067, 2v1b, 2007-02-15
,
Eltek Energy .
PowerSuite – ,
PowerSuite
,
:
•
PowerSuite, .6
PowerSuite.
,
, .
• PowerSuite, c . 11
PowerSuite: ,
, , , ,
.
• PowerSuite, .4
,
,
.
• .8
Eltek
.
• . 18
Eltek
, .
PowerSuite
PowerSuite,
, ,
.
PowerSuite
PowerSuite
.
PowerSuite
PowerSuite:
• :
MS Windows XP,
60 ,
800×600
• ,
,
USB
•
Smartpack
Smartpack
Smartpack –
, « ».
.
.
, Web- .
USB RS-232
SNMP Web- .
Smartpack
( ), , 9-
D- ( ),
)
( ).
Smartpack
.
PowerSuite.
PowerSuite
PowerSuite
MS Windows XP.
,
.
ü USB
.
PowerSuite
:
1. « PowerSuite", .
7.
1. PowerSuite
•
• PowerSuite,
InstallShield Wizard
,
Install PowerSuite.
“.Net” ,
, .
PowerSuite
.
2. « Smartpack
USB », . 8.
2. Smartpack USB
USB
USB Smartpack
USB .
3. « PowerSuite», . 9.
3. PowerSuite
PowerSuite
,
Smartpack, « »
(The Last Connected Site) « » (Connect)
( . . !
.).
PowerSuite
. ,
« » (Site manager), .
28.
PowerSuite
, “ ”
(Options), . . 29, ,
COM , .
PowerSuite
Power Summary.
Power System,
.
. . 8, « »
(Program Window).
PowerSuite .
PowerSuite
PowerSuite: ,
, , , ,
.
PowerSuite ( . “
PowerSuite”, . 7)
. ,
Windows Explorer).
. . 9.
, (2)
(3) (
Power Summary).
( )
Power Summary,
.
“ ”, “ ”
“ ” Animation pane,
.
. . 9.
,
,
,
.
. . . 12, “ , ,
”( , , ).
( . 102), “ ”,
”, .
, ,
) ( ,
).
PowerSuite
:
• Power Explorer (1)
• Power Summary (2)
• Power Animation (3)
PowerSuite
: - Power Explorer
(1), – Power Summary (2),
Power Summary – Power Animation (3).
,
Power Summary (2) Power
Animation (3).
« » (View menu)
<Ctrl+E>, <Ctrl+A>
and <Ctrl+S>.
,
. :
•
• .
« » (View Menu)
•
Power Summary
, .
(8)
.
.
P « » (Close)
PowerSuite
PowerSuite,
.
,
, . . 8, « »
(Program Window).
(Access Levels)
PowerSuite
. ,
Smartpack.
:
• (User Access Level)
PowerSuite. .
( ), ,
.
» (Apply) «OK» .
• (Service Access Level)
,
( ).
( ).
, - <0003>.
.
• (Factory Access
Level)
,
,
Eltek ,
,
(LVD)
.
, , (Menus,
Icons and Toolbar)
,
PowerSuite ,
.
“ ” (Access)
“ ” (Access)
“ ” (Access) ,
<Alt+A>.
:
Smartpack.
F2
” .
• (Disconnect) (F3)
PowerSuite
Smartpack.
F3
” .
• (Login) (F4) PowerSuite
“ ” ( . 19).
, .
F4 “
” .
• (Logout) PowerSuite
( ).
, « » (Apply) « »
).
.
“ ” .
• (Change Password)
PowerSuite “
”( . . 27)
• (Exit) (Alt+F4)
PowerSuite.
F4.
“ ” (Tools)
“ ”
“ ” (Tools)
<Alt+T>.
:
F5.
• (Search for New Units)
PowerSuite
,
Power Explorer.
Power Explorer.
• (Options) (Ctrl+O) PowerSuite
“ ”( . 22),
,
.
“ ”
Ctrl+O.
•
(Import/Export Configuration) (F6)
PowerSuite
”( . . 76), :
1.
Smartpack
PowerSuite,
2.
Smartpack.
“
”
F6.
• (Data Logging)
« » (Windows)
“ ”
” (Window) ,
<Alt+W>.
:
• (Cascade) PowerSuite
(A, B) ,
,
,
(A) .
(B),
.
“ ” (View)
“ ”
” (View)
<Alt+V>. :
Ctrl+E
• Power Animation (Ctrl+A) PowerSuite
Power
Animation.
Ctrl+
• Power Summary (Ctrl+S) PowerSuite
Power Summary.
Ctrl+S
. . 8, « »
(Program Window) . 9, « »
(Window Panes).
“ ” (Help)
“ ”
” (Help)
<Alt+H>.
:
• Flatpack 2…
(Help on Flatpack 2) (F1) PowerSuite
F1.
• Eltek Energy… (Eltek Energy)
PowerSuite
Eltek Energy .
PowerSuite.
(Toolbar)
, PowerSuite
Smartpack
:
• (Last
Connected Site) ( ).
-- PowerSuite
Smartpack
,
). . . 21,
« » (Site Manager).
--
» ,
,
.
• (F2) (Connect) (
) PowerSuite
« » (Site Manager) ( . . 21),
Smartpack.
. . 12, “ " " (Access
Menu).
, PowerSuite
Smartpack,
:
• (F3) (Disconnect)
PowerSuite
Smartpack.
. . 12, « « » (Access
Menu).
• (System Voltage Levels)
PowerSuite
”( . . 23),
.
• (System Configuration)
,
, ,
.
• (Battery Tests
Results) PowerSuite
“ ”( . . 2),
.
• (Event Log)
• (Active Alarms Groups)
• (Log In button )
PowerSuite
PowerSuite,
,
.
PowerSuite ,
.
,
,
,
.
“ ” (Power
System)
(General)
“ ”,
.
(Secutiry)
“ ”,
.
“ ” (Log In)
1. ,
, .
2. Ok.
.
, ,
PowerSuite, ,
Smartpack
, « »
(Apply) « »( ).
.
ü , - <0003>.
.
,
PowerSuite
( ).
,
PowerSuite
.
,
:
1. Power Explorer
“ ”
(Power System).
” (Power System).
2. “ ”
(Security).
" " (Access Level)
.
“ ” (Change
Password)
ü , - <0003>.
,
:
1.
),
2. ,
, " " (Enter Current
Password)
3. " " (Enter
New Password).
" (Confirm New
Password)
4. « » (Apply).
P .
, .
Eltek Energy,
.
“ ” (Site Manager)
" (Connect) ,
" (Connect) « » (Access Menu) ( .
. 12).
,
PowerSuite Smartpack.
1. ,
( USB) 4).
–
,
Smartpack
.
2.
“ ” (Connect) .
PowerSuite
Smartpack,
.
( ) (Serial
(Virtual USB)
« » (Site manager),
COMx ( «
) »( Serial (Virtual USB),
Smartpack.
" (Options) .
(General)
“ ”,
.
(Language)
“ ”,
.
. . 2, « »
“ ” (System
Voltage Levels)
« »
(General)
“ ”,
.
(LVD)
“
”,
.
“ ” (Alarm Monitor)
,
(
). ( )
(A) (B)
.
), (
).
.
-
,
.
. . 2,
».
(General)
“ ”,
.
.
.
,
) ,
ProgInput 1.1.
. . 2,
».
(Activate)
,
.
,
, .
(Manual Reset)
" "
( , ,
) .
« »
:
• (Disable).
.
• (All Levels).
.
• (MajorHigh).
.
.
(Hysteresis and
Time Delay)
.
(Hysteresis)
(
)
.
.
(Time delay)
, . ,
,
.
. . 2,
».
(Description)
« » (Change)
.
.
.
, (Event,
Values and Alarm Groups)
. “ " :
• ,
« » (Event),
.
• (
)
• « » (Apply).
. “ " :
• ,
, ,
.
• (
)
• « » (Apply).
,
, .
. .
, ,
, . .
. 2, " ".
(Details)
“ ” (Details),
.
,
.
» (Details).
« » (Details),
,
.
. . 2,
».
(Average Monitor)
,
.
• “ ” (Restart the
average monitor), .
(Peak Monitor)
.
• “ ” (Restart the
peak monitor), .
"
, LVBD" (LVBD)
" "
(LVBD) " " (Battery),
" " (Status).
. . 2,
».
<<< “ ” (Battery),
" " (Status), .2
“ ” (Battery more)
“
” (more) " " (Battery),
" " (Status).
1. ,
.
“ ”,
.
. .
2. “ " (Apply)
”.
, . . 2,
« ».
<<< “ ” (Battery),
" " (Status), .2
(Mains)
,
.
(Rectifier)
,
.
“ ” (Rectifier
Details)
XLM
.
MS Excel.
(Load)
,
.
(Battery)
Power Explorer.
, .
" " (Options), . 22.
. . 2,
« ».
,
.
“ ” (Battery)
Power Explorer.
,
.
,
.
(Status)
,
( )
.
. . 2,
« ».
o ,
" "
(“BatteryVoltage”).
o ,
" " (“BatteryCurrent”).
o ,
" "
(“BatteryTemp”).
o ,
" "
(“BatteryLifeTime”).
,
. . . 2, “
”.
o
(LVBD). " " (Normal)
,
.
o (Fuses) B1,
B2 . " " ,
.
o
"
" (BatteryQuality) " "
(BatteryTotCap).
,
“
1” (Current Ref 1). . . 2,
“ ” (Battery Table Data)
o
" "
(BatteryRemCap) " "
(BatteryTimeLeft).
,
“
1” (Current Ref 2). . . 2,
“ ” (Battery Table Data)
o .
" .
" (“DeltaStringCurr”).
. .
. 2, “ ”
(Discontinuance Battery Tests)
“ ” (Apply) “OK” , .
.
,
.
. . 2,
».
(Configuration)
“ ” (Battery)
Power Explorer, " "
(Configuration).
o :
-- (Battery Size)
-- (Battery Type)
--
--
o “ " (Apply)
”.
o “ ”
,
, 3.
ü
Smartpack.
,
Smartpack, ,
1. ,
Smartpack,
, 2,
.
PowerSuite
.
, . . 2,
« ».
.
. . 2, «
».
o " ( )"
(Capacity (Ah per string)) ,
.
o « »
“ ” (Battery Install Date).
.
:
,
, .
,
.
(Temperature Compensation)
o “ ( )”
(Reference Voltage (V/Cell))
, “
(C)” (Reference Temperature)
.
o “ (C)”
(Reference Temperature)
,
356807.067, 2v1b, 2007-02-15 45
PowerSuite
“
)” (Reference Voltage (V/Cell))
.
o “
”( )” (Temperature
Slope (mV/°C/Cell))
,
°C
,
.
o “
( )” (Min Compensation Voltage
(V/Cell))
(
).
o “
( )” (Max Compensation Voltage
(V/Cell))
(
).
.
“ ”
(Activate Temperature Compensation)
( )
.
( )
.
“ " (Apply)
Smartpack.
.
. 2, « ».
(Current Limitation)
“ ” (A),
.
,
, . <100>
o “ ” (Generator Feed( ))
“ ” (Current Limit
Value (A))
, , .
<10>
o “ ” (Active) (D
( )
.
( )
.
“ " (Apply) (E),
Smartpack.
.
.
. .
3, « ».
. “
”, .3
“ ” (Battery)
Power Explorer, " " (Test).
:
o
o
o
:
o :
--
--
--
--
--
o “ " (Apply)
“ ”.
. . 3,
».
,
:
o
" (Simplified Test).
o “ ( )”
(End Voltage (volt/cell)),
“ ”,
, :
<1.92>
o “ (
.)” (Max Duration (minutes))
, : <240>.
o “ ( -
.)” (Max Discharge (Ah))
, :
<75>.
o “ ( )” (Guard
Time (hours))
,
<12>.
– 1000 41,6 .
. . 3, «
».
o
” (Activate)
.
( )
.
o
» “ ”
,
, “
” <Battery test ON>.
, “
” <Battery test ON>,
. . . 2,
« ».
« ».
o .
. . 2, “
: ,
”.
.
.
. . 2,
».
,
:
o
" (Normal Test).
“ ( )” (End
Voltage (volt/cell)), “
” (Normal Test), , .
o “ (
.)” (Max Duration (minutes))
, <240>.
“ ( .)” (Max
Discharge (Ah)) , .
.
o “ ( )” (Guard
Time (hours))
,
<12>.
– 1000 41,6 .
. . 3, «
».
o
” (Activate)
.
( )
.
o « »
“ ”
,
, “
” <Battery test ON>.
, “
” <Battery test ON>,
. . . 2,
« ».
o .
. . 2, “
: ,
”.
.
.
. . 2,
».
(Discontinuance
Battery Tests)
.
. 2, « ».
ü – ;
“ ”
” .
ü
.
ü
“ ” “
”.
ü ,
( )” (G) “ ”.
" ( ) " "
, ,
, G.
.>>.
:
o “ ”
(A) (Activate)
,
.
o « »
“ ” (Alarm
Group) ,
, “ ”
<Battery test ON>.
,
” <Battery test ON>,
. . . 2,
« ».
o " "
(Interval Test) (B),
.
o “
( )” (C)
.
:
,
, .
,
.
o ,
( )” (Next Start
Time) (D) :
,
(D).
,
(D).
o
” (Activate) (E)
.
o "
" (Discontinuance Test) (F),
.
o " ( )” (G)
, ,
: <7> ( 0 7). ,
,
" ( )" (Interval Period
(days)) " "
(Interval Test).
o “ (
.)” (Max Duration (minutes)) (H)
, :
<5> ( 1 10).
o
” (Activate) (I)
.
o “ " (Apply) (J)
”.
. .
2, « ».
: ,
:
o
o
o
"
" (Discontinuance start method)
.
.
. 2, « ».
,
:
o “ ”
(Start Test),
. PowerSuite,
,
“ :”
" (Mode: MANUAL TEST).
o “
” (Stop Test)”
.
PowerSuite,
,
“ :” ” (Mode:
FLOAT”).
, ),
o " "
(Interval Test) (A),
.
o “
” (Next Start Date) (B)
.
:
-- ,
, .
-- ,
.
o ,
( )” (Next Start
Time) (C) :
-- ,
(C).
-- ,
(C).
o " ( )”
(Interval Period (days)) (D)
, : <180>.
o (E)
,
.
,
, .
o “
” (Inhibit Interval Test)
(F),
.
o
” (Active)
.
:
o " "
(Auto Test)
o
” (Active)
.
" "
(Discontinuance Test)
"
" (Discontinuance start method)
.
. . 2, “ ”.
(Boost)
“ ” (Battery)
Power Explorer, " " (Boost).
, ,
, :
2,23 2,33 .
:
o
o
o
o :
--
--
--
o “ " (Apply)
”.
“ ” (Common)
,
:
o “ ( )” (Voltage
(V/Cell))
, : <2.2708>.
,
, , ,
,
.
o « »
“ ” (Alarm
Group) (B)
,
, :“
” <Boost Charging ON>.
, “
” <Boost Charging ON>,
. .
. 2, «
».
o
. .
».
(Manual Boost)
,
:
o "
" (C) (Manual Boost),
.
o “
( .)” (Max Duration (minutes)) (D)
, <120>.
.
o “ " (Apply) (E),
o “
” (Start Boost) (F) ,
.
(Interval Boost)
,
,
:
o "
" (Interval Boost) (A),
.
o “
( .)” (Max Duration (minutes)) (B)
, <120>.
.
o “
” (Next Start Date)(C)
.
:
-- ,
, .
-- ,
.
o ,
( )”
(Next Start Time) (D)
:
--
,
(D).
--
,
(D).
o " ( )”
(Interval Period (days)) (E)
, :
<180>.
o
” (Active) (F)
.
(Auto Boost)
,
o "
" (Auto Boost) (A),
.
o “
( .)” (Max Duration (minutes)) (B)
, <120> (
0 1200).
,
" (Charge Factor), .
( ),
.
, (
) 100
150
.
o " ( )”
(Discharge Threshold) (D) -
(Temperature
Monitor)
“ ” (Battery)
Power Explorer, " "
(Temperature Monitor).
o :
-- (Low Limit)
-- (High Limit)
-- (Weight)
o
» (Enable)
o “ " (Apply)
”.
“ ” (Hours)
,
0( ), “
" (Reset Battery Lifetime monitor).
" "
(Battery), “ ” (Status), c . 32
.
. 2, « »
(BatteryLifeTime), «
».
(Symmetry Configuration)
“ ” (Battery)
Power Explorer, "
" (Symmetry Configuration).
. . 2, «
».
,
.
o
:
-- (enable/disable)
-- (symmetry
setup)
-- , (event,
level, alarm group)
o “ " (Apply)
”.
(Enable / Disable)
o
” (Enable
Symmetry). PowerSuite
,
,
“ ”
(Symmetry), . . 2.
o “
” (Enable Symmetry) (
) .
"
" (Symmetry Setup)
(Symmetry voltage):
-- « »
« » (Symmetry
Voltage)
-- ,
.
12 :
o 12
48 .
o 24
48 .
o 24
48 .
o 12
24 .
12 .
. .
2, « ».
: (Symmetry mode)
-- « »
-- :
o (Continuous).
.
o (Discharge).
(
).
. . 2, «
».
(Discharge Delay).
” (Discharge Delay)
,
.
- .
«
, , )» (Alarm
Limits (Event-Level-Alarm Group)
o “ ” (Level)
(
), “1,50” “1,00”.
o « »
“ ” (Alarm Group)
.
)
x.x” (SymmDelta x.x)
,
, 1,5
) 1 ( ).
ü “
x.x” (SymmDelta x.x)
“ ” (Symmetry), . 2.
“ ” (Battery
Table Data)
“
” (Edit Battery Table)
" (Battery), " "
(Configuration).
, .
. . 2,
« ».
<<<
(Battery), " " (Configuration), .2
:
1. :
-- « »
« » (Select Battery
Table)
--
-- “ ” (Get Data)
, . . 2,
« ».
2. “ " (Apply),
Smartpack.
3. “
” (Battery Table Data)
” (Battery) OK.
4. " "
(Battery) “ ” (Refresh)
“ ” (Tools) F5.
,
,
, ,
.
,
.
:
1. :
-- “ ” (Description)
.
2.
:
-- " . "
(High End Volt) “ . ” (Low
End Volt) .
3. ,
:
--
--
,
-- TAB
,
SHIFT+TAB - .
-- “ (Add
row)" " " (Delete row)
.
4. “ " (Apply),
Smartpack.
5. “
” “ ” (Battery)
OK.
6. " "
(Battery) “ ” (Refresh)
“ ” (Tools) F5.
, ,
.
, :
1.
2. ,
.
“ ”
(Battery Test Results)
“
” (View Test Results) " "
(Battery), " " (Test).
. –
. ,
,
.
:
o " " (Export to File)
(B),
XLM ,
:< .xlm>
o “ ” (Details) (A)
" (Battery Test
Log Data),
, . 2.
<<< “ ” (Battery),
“ ” (Test), . 37
“ ”
(Battery Test Log Data)
” (Details) “
" (Battery Test Results), . 52.
.
:
o « »
“ ” (Select Data to
be Displayed) (A) ,
.
o ,
.
.
o « .» « .» (C)
,
Y .
o
“ ”
(Load Data) (B).
<<< “ ” (Battery),
“ ” (Test), . 37
(Status)
. . 2, «
».
1.
o 1,
"
1" (“BattVolt bank1”).
o 1,
" 1" (“BattCurr
bank1”).
o 1 (Fuse B1).
" " (Normal) ,
.
o
(Symmetry monitors).
" " (Normal) ,
.
“ "(Major)
” (Minor) ,
Smartpack.
. . 2,
» (Symmetry dialogue box).
“ ” (Apply) “OK” , .
.
,
« 1» (BattVolt
bank1) « 1» (BattCurr bank1).
. . 2,
».
« » (Currents)
“ ” (Currents icon), “
” (Battery banks 1) Power
Explorer.
. . 2, «
».
:
o 1,
" 1.1" (“BattCurrent 1.1”).
“ ”, . 54 («
1» (BattCurr bank1)) ,
1.1 1.2 ( «
x.x» (BattCurrent 1.1, BattCurrt 1.2))
“ ” (Apply) “OK” , .
.
,
“ x.x” (BattCurr x.x).
. . 2,
».
« » (Fuses)
“ ” (Fuses),
“ ” (Battery Bank)
Power Explorer.
. . 88 110 ,
».
:
o 1 (Fuse S1).
" " ,
.
“ "(Major)
” (Minor) ,
,
.
“ ” (Apply) “OK” , .
.
,
“ x.x”
(BatteryFuse x.x).
. . 2,
».
« » (Temperatures)
“ ” (Temperatures),
“ ” (Battery Bank)
Power Explorer.
. . 88 110 ,
».
“ x.x”
(BatteryTemp x.x).
,
.
“ ” (Apply) “OK” , .
.
,
“ x.x”
(BatteryFuse x.x).
. . 110,
« ».
“ ” (Symmetries),
“ ” (Battery Bank)
Power Explorer.
,
,
. . 88, 110 89 , «
».
« x.x»
(SymmDelta x.x) :
o :
= .
= .
= .
o (Symmetry
Voltages)
o (Delta Voltages)
( . )
«
x.x» «SymmDelta x.x»,
(24 = 2x12 ).
«
x.x» «SymmDelta x.x», ,
,
1,5 ( ) 1 (
).
. . 92, « ».
“ ” (Apply) “OK” , .
.
,
« x.x»
«SymmDelta x.x».
. . 110,
« ».
ü
x.x» (SymmDelta x.x),
,
, . . 48, "
” (Symmetry Configuration tab).
(Control System)
,
Smartpack.
“ "
(Import/Export Data )
»
» (Tools)
F6.
. .
" " (Log In), . 19.
Smartpack (
) . "
", . 67.
,
Smartpack
) PowerSuite:
A.
" (Read from a file) (1).
B. (2)
( XML).
C. “ " (Go) (3) ,
. ,
,
(4) «
» (Read from file
succeeded).
,
Smartpack ( )
PowerSuite:
A.
" (Read from Smartpack) (1).
B. “ " (Go) (3) ,
.
(4)
« » (Reading
from Smartpack). ,
,
(4) «
» (Read from
Smartpack succeeded).
. . 67, "
".
“ ”
(Save as type).
C. “ ” (Save) ,
.
D. “ " (Go) (7) ,
.
, ,
(4) «
» (Write to file succeeded).
,
( )
Smartpack PowerSuite
:
A.
" (Write to
Smartpack) (5).
B. “ " (Go) (7) ,
Smartpack.
(4)
« »
(Writing to Smartpack). ,
,
(4) «
» (Write to Smartpack
succeeded).
. . 67, "
".
“ ” (Control Unit)
(Summary)
“ ” (Summary),
.
" ” (Info)
.
(Control
Unit information)
,
Smartpack (1).
CAN-
, . . 84,
».
(Software version)
(2) ( ),
Smartpack.
-
.
,
Smartpack.
.
–
).
.
, .
,
.
ü
. .
. 19, " " (Log In).
«
» (LVBD OG) «
» (LVLD1 OG)
.
. . 112,
».
,
:
1.
( )
.
2. .
.
3. “ " (Apply).
,
,
. F5,
.
.
.
.
,
(
).
,
,
1.
,
.
: ,
. .
:
“ ” (Generator AOG)
2 (Alarm output2) (
).
“ 2”
(Alarm output2).
2. “ " (Apply).
,
,
. F5,
.
)
.
1. (a)
,
.
” (Output configuration),
PowerSuite.
2. ,
« »
(Description) ( )
(b).
,
« » (c)
:
-< > (Normally Activated).
, ,
( ).
-< > (Normally Deactivated).
, ,
.
.
3. , “ " (Apply)
(d). «OK», .
F5, .
.
.
P
, .“ ”
(<Latched Contactor>).
> (Normally Activated) <
> (Normally Deactivated).
(
) (Input Handler)
“ ”,
.
(Input Handler) –
, ,
,
.
(A). .
.
, ,
. -
.
: “
1.4” (ProgInput 1.4) ,
4 Smartpack 1,
.
:
• (Disabled).
.
• (Normal).
.
• (Alarm).
.
. .
. 25, « »
", . 71.
. . . 66,
“ ”.
“ ” (Input
Configuration)
,
" " (Input Handler),
“ ” (Control Unit), .
65.
,
( )
:
1. « »
:
– (Normally Closed) (
,
,
).
– (Normally Open) (
,
,
).
– (Diode Matrix) (
,
).
2.
“ " (Apply) “ ”.
,
PowerSuite.
:
Smartpack
).
P
. .
" " (Log In), . 19.
P
. . . 69,
« »
: ,
Smartpack A
Smartpack B
(“ ” ).
1:
.
2:
3:
B.
:
1.
PowerSuite.
2.
Smartpack B.
3.
PowerSuite .
, «
» (Import/Export Configuration)
» (Tools)
F6.
« 1.
PowerSuite», . 67.
1.
PowerSuite
.
1.
Smartpack PowerSuite
, ,
( )
2. ,
« 2. », . 68.
2.
,
Smartpack A
Smartpack .
1. “ ” (Disconnect)
PowerSuite.
2. USB Smartpack A
).
3. USB Smartpack B
).
4. “ ” ( onnect)
PowerSuite.
« 3.
PowerSuite», . 69.
3.
PowerSuite
B.
1. ,
2.
Smartpack,
"
" (Write to Smartpack) (L),
“ " (Go) (M) " "
(destination).
(N)
« »
(Writing to Smartpack).
, ,
(O)
Smartpack A Smartpack (« »)
.
«
»( . . 67) .
PowerSuite
: ,
( ,
) .
. . 19, «
».
Smartpack
:
,
Smartpack.
,
Smartpack:
A.
" (Control unit) (1)
Power Explorer.
B. ,
" "
(Control unit) (2), " " (Info).
:
. ,
.
. . 112,
».
ü
,
“ ” (Generator AOG).
1 2.
« 8» (Alarm Group
8).
"
" (Control Unit) Power
Explorer. «
» (Alarm Group Configuration),
.
,
:
1. (A).
, 1 2
.
. . 63, «
».
:
,
, ,
, .
,
. . 110 112, «
».
ü
:
1. .
2. .
3. .
« 1.
», . 72.
356807.067, 2v1b, 2007-02-15 93
PowerSuite
1.
"
" (Control Unit) Power
Explorer. «
» (Alarm Group Configuration),
.
1. " " (Generator AOG)
2. 1 2 " "
(Generator AOG).
. . 70, “
”.
« 2.
», . 72
2.
“ " (Battery)
Power Explorer.
“ ” (Configuration) (A)
“ ” (Current Limitation) (B),
.
1.
( « »,
(Generator feed) (C)).
«
» (Current Limit Value (A)) <10>.
. .
2.
” (Activate)
.
3. " " (Apply) (E).
.
. 105, « ».
« 3.
», . 73.
3.
"
" (Control Unit) Power Explorer.
“ ”
(Input Handler).
1. ,
:
" (Input Configuration ),
"
1.1" (PorgInput 1.1) (A):
(B)
» :"
» (Normally Closed) (
, ,
)
“ " (Apply) (C).
2.
1.1 (A),
« 1.1»
(ProgInput 1.1) (A).
3. « »
(D) “
” (Battery Current Limit).
4. « »
(E)
» (Generator AOG).
5.
” (Activate)
(F).
6.
(G),
“ " (Apply) (G)
"
1.1" (ProgInput 1.1) " " (Input
Configuration), “ ”.
" 1.1" (ProgInput 1.1)
.
7. " " (Apply) (H)
" 1»
(Control Unit 1), “ ”.
.
.
,
, ,
.
«
»( . 71)
.
Eltek Energy
Eltek Energy –
,
.
,
, ,
. ,
Eltek Energy
,
,
.
, ,
( )
Eltek .
,
.
Eltek.
,
, ,
.
, ,
,
Eltek Energy -
.
,
.
(Ethernet).
,
Eltek
.
Eltek Energy
, ,
Eltek Energy,
,
, ,
.
, Eltek.
,
:
• ( . 80)
.
• AC ( . 83)
.
• ( . 84)
.
• ( . 86)
.
• ( . 109)
Smartpack.
,
(PE)
.
(+ –).
(PE)
(TE)
1 2. ( )
.
48 60
, , «+»:
.
24 , , «-»:
.
CAN-
Smartpack
CAN- ( ).
,
Smartpack
( ),
,
CAN- .
, CAN-
(01, 02 …), .
, 120Ω
.
CAN- 120Ω (
60Ω).
, ,
Flatpack2.
CAN- 120Ω.
Flatpack2, CAN-
CAT5. 120Ω
60Ω).
Flatpack2 :
• (Float Mode)
• “ ” (Test Mode)
• “ ” (Boost Mode)
PowerSuite.
,
. (LVD)
,
. ,
.
PowerSuite
, ),
.
A. (MainsLow)
).
B. (Battery Current Minow
Low).
C. «A» «B».
D. «A» «B».
. « » (System
Configuration).
,
Smartpack
PowerSuite.
Smartpack
, .
Flatpack2
.
( ), ,
, Smartpack
,
.
,
, ,
.
,
Smartpack
PowerSuite.
Smartpack
,
Smartpack « > »
(«UserOption>VoltageInfo»).
« » (VoltageInfo)
3):
. . (NomVolt)
. (BoostVolt)
. . . 1 (LowBatt1)
1
. . . 2 (LowBatt2)
2
. . . 1 (HighBatt1)
1
. . . 2 (HighBatt2)
2
. 1 (LVD1) 1
PowerSuite
“ ” (System
Voltage Levels),
,
PowerSuite,
:
• ( ) (Nominal
voltage (float))
• (Boost Voltage)
• (Rectifier
standby voltage)
• (Battery disconnect
voltage)
• (Rectifier OVS
trip voltage)
. «“ ”, . 23.
( )
Smartpack
PowerSuite.
Smartpack
Smartpack « »
(«UserOption>DisplayMessages»).
1000 ,
.
, , .
,
.
EEPROM.
,
Smartpack
, , ,
.
230V Flatpack2
, . ,
.
,
.
,
Smartpack ,
.
, Smartpack
“ID” 01, 02 03
L1, L2 L3 .
,
“ID” 04, 05 06,
.
,
“ID” 07, 08 09.
:
02 , L1,
L1 L2.
,
Smartpack “ID”
, "01".
( CAN )
Smartpack.
(
) Flatpack2 ,
Smartpack " " ,
.
, " " ID
,
.
ID ,
Flatpack2 " ",
, 1, 2, 3 .
9,
.
,
.
,
.
,
,
,
.
: , 10 ,
ID "04" .
ID # 10 ID # 04,
«ID » , Smartpack
, 9.
ID # 10 ID # 04,
.
Smartpack PowerSuite.
Smartpack
Flatpack2 ,
Smartpack,
» («UserOption>Rectifier
Info»).
« » (Rectifier Info)
( 3):
.(NoOfRects.)
. (RectCurrent)
(RectSerialNumber)
. (Rect.PrimaryVolt)
. . (Rectifier Status)
. (Rectifier Temp)
Smartpack
, ,
.
200 . Smartpack
Flatpack2,
CAN- . :
• Smartpack
•
•
•
•
PowerSuite
,
“ ” (Rectifier)
Power Explorer, :
•
•
•
•
•
•
. “ ”, . 31.
Smartpack ,
.
,
,
,
• (
).
• ( ).
•
• CAN
•
,
•
.
• (
Smartpack).
•
. “ ”, . 31.
48 48 ;
12 .
24 24 ;
12 .
Flatpack2
,
.
Smartpack
:
:
o SB
o SB
:
o SB
o SB
o Bx
:
o Sx
o Sx
o Sx
– ,
, ,
.
:
o .
o .
o .
48 .
,
48 .
,
.
ON,
( .
).
Flatpack2
Smartpack
.
PowerSuite,
» («Symmetry
reconfiguration»).
Smartpack 8
(CON3 CON4), :
o 2 ( )
o 4 (
)
o 8 (
)
24 .
24 . .
24 ,
12 ,
.
.
,
(Continuous Symmetry Mode)).
(
(Discharge Symmetry Mode)).
,
(
(Discharge Delay)).
– ,
. . "
", . 89.
.
, ,
(24 ), PowerSuite
48
.
.
1 1.
53, 26
" "
(BatteryVoltage),
Power Summary PowerSuite.
“ ” (Symmetry)
«
x.x» «SymmDelta x.x», ,
,
1,5 ( ) 1 (
).
.
:
356807.067, 2v1b, 2007-02-15 116
PowerSuite
(V / 2) V =|V |
“
1.1” (SymmDelta 1.1) PowerSuite
“ 1.1”
(SymmDelta 1.1) ,
,
:
1,0V >| 0,56 V |
“ 1.2”
(SymmDelta 1.2) ,
,
:
1,5V <| 1,57 V |
“ 1.4”
(SymmDelta 1.4) ,
,
,
:
1,5V >| 1,27 V |> 1,0V
, ,
(12 ), PowerSuite
48
.
:
.
2 1.
54, 00
" "
(BatteryVoltage),
Power Summary PowerSuite.
“ ” (Symmetry)
«
x.x» «SymmDelta x.x», ,
,
1,5 ( ) 1 (
).
.
:
(V / 4) V =|V |
“
1.1” (SymmDelta 1.1) PowerSuite
“ 1.1”
(SymmDelta 1.1)
,
:
1,0V >| 0,94 V |
“ 1.2”
(SymmDelta 1.2) ,
,
:
1,5V <| 2,31 V |
“ 1.4”
(SymmDelta 1.4) ,
,
,
:
1,5V >| 1,09 V |> 1,0V
PowerSuite
Smartpack
.
. “ ”, . 150.
, .
,
« »
” (Get Data).
:
o Eltek (Eltek Standard).
,
Eltek
.
o 1.
Fiamm SLA100.
, ,
,
.
“ ” (Description), " .
" (High End Volt), “ .
” (Low End Volt).
o 2.
M12V155FT.
, ,
,
.
“ ” (Description), " .
" (High End Volt), “ .
” (Low End Volt).
o ,
.
,
.
PowerSuite
,
.
"
“Ref1”, –
« » “Ref 2”.
:
o » (Description), . .
,
.
o
:" . Ref 1" (High
End Volt, Ref 1) “ . Ref 2”
(Low End Volt, Ref 2).
o :
1. " (Minutes) -
.
2.
" . Ref 1"
(High End Volt, Ref 1) –
.
3.
" . Ref 2"
(Low End Volt, Ref 2) –
.
ü " " (BatteryQuality)
" " (BatteryTotCap)
“Current ref 1” .
ü " "
(BatteryRemCap) " "
(BatteryTimeLeft)
“Current ref 2” .
ü
« » (Battery) ( . . 32), « »
(Status).
:
o " " (Export to File),
o “ " (Apply),
Smartpack.
,
PowerSuite. . .
96, « »
. . 102, "
", - ,
.
,
Smartpack ,
,
.
56
Battery
Voltage
54 Rectifier
Standby
Voltage
MajorLow
52
Battery
Alarm
Vdc
50
48
46
44
30
94
96
0
8
10
50
70
86
88
90
92
time [min]
(“ "
))” (End Voltage (volt/cell)).
,
.
, .
Smartpack
,
, .
Discharging Characteristic
Discharging current vs. time, for a specific end voltage
A
T1 = Real Time
T1 T2 t
: . . 37,
» (Battery), « » (Test).
PowerSuite Smartpack
:
o
o
o
, –
. . .
102, “ ”
(Discontinuance Battery Test).
,
.
(“ "( ))”
(End Voltage (volt/cell)).
,
,
,
(Max Duration
(minutes)),
( ) (Max Discharge (Ah)).
,
, .
, :
o ( ) (End Voltage
(volt/cell))
o ( .) (Max
Duration (minutes))
o ( .)” (Max Discharge
(Ah))
ü ,
( .)
( ), ,
.
.
. . 37, « » (Battery),
« » (Test).
.
,
,
(“ "( ))”
(End Voltage (volt/cell)).
,
,
,
(Max Duration
(minutes)),
( ) (Max Discharge (Ah)).
:
o ( ) (End Voltage
(volt/cell)). .
o ( .) (Max
Duration (minutes)). .
ü ,
,
,
.
. . 37, « » (Battery),
« » (Test).
. . 102, “ ”
(Discontinuance Battery Tests)
PowerSuite Smartpack
:
o
o
o
, "
" (Discontinuance start method)
( )
PowerSuite
,
, . ,
.
,
. – 1000
41,6 .
ü ,
,
336 (14 ), « »
.
. . 37, « » (Battery),
« » (Test).
“ ” (Start Test)
“ ” (Stop Test),
.
« » (Battery), « » (Test),
Smartpack.
PowerSuite , ,
,
.
(
,
).
.
, , PowerSuite
19- 2007 18.00
180
.
,
, .
.
,
(“ ( )”),
(End Voltage (volt/cell)),
, .
.
. . 102, “
” (Discontinuance Battery Test).
:
o
“ ” (Interval Test))
o “
” (Discontinuance Test)
( .)” Max
Duration (minutes)
( 1 10).
o “
” (Discontinuance Test) "
( ) (Repeat Frequency (days))
( 0 7 ).
-
,
.
" ”
, , ,
.
( . . 89),
,
.
, .
,
,
,
.
, CAN
Smartpack,
,
.
, Smartpack
.
( )
.
( )
" . "
(DeltaStringCurr),
.
,
, ,
5% .
" .
" (DeltaStringCurr)
(Battery) ( . . 32), « » (Status).
,
.
.
30 ;
10 (
). [(10+10+10)/3]=10
,
5 ,
12,5 .
, , 10 : [(5+12, 5+12,
5)/3]=10
( )
:
5 : (5/10) *100=50% (
50%)
12, 5 : (12, 5/10) *100=125% (
25%)
"
" (DeltaStringCurr)
50% ,
5 .
.
,
.
. . 105, “
".
100% .
,
.
. . 105, “
".
,
Smartpack
.
,
20 ºC
48 .
56,64
54,72
52,8
0 10 20 30 °C
Temperature
:
o ( )” (Reference Voltage
(V/Cell)).
356807.067, 2v1b, 2007-02-15 130
PowerSuite
, , 20°C,
.
o ”
°C/ )” (Temperature Slope
(mV/°C/Cell)). ,
.
°C ( ,
).
:
o
)” (Min Compensation Voltage (V/Cell)).
.
o
)” (Max Compensation Voltage (V/Cell)).
.
,
,
.
-3 /°C/ (
) and -5 /°C/ ( ,
, , ).
:
. 25°C
.
20°C 25°C.
25°C.
, .
, .
25°C,
.
0°C
.
, ,
.
, ,
20°C.
-
,
.
356807.067, 2v1b, 2007-02-15 132
PowerSuite
. . 106, “
".
, .
,
,
.
ü , , ,
,
, , .
,
, , .
,
,
.
ü
Efficiency Manager .
,
,
.
,
,
.
,
,
.
.
,
, .
, -
.
,
85% (10, 2
12 ).
«
»
Smartpack ,
.
.
" "
(BatteryLifeTime) (
“ ” (Status) " "
(Battery) ( . 32)),
" " (Temperature Monitor) ( .
47). ,
.
,
,
" "
,
. :
o
(
).
o
o 24,
.
“ ”.
, °C , °C ( )
01 00 10 1 96
02 11 20 1 20
03 21 30 2 360
04 31 40 2 130
05 41 50 3 120
06 51 60 3 00
07 61 65 4 00
08 66 70 6 00
09 71 75 12 00
10 76 99 64 00
, , ,
"
", :
01 1x96 96
02 1x20 20
03 2x360 720
04 2x130 260
05 3x120 360
1456
Smartpack.
Smartpack. .
Smartpack –
, « ».
.
.
Eltek
PowerSuite ,
Web- .
USB RS-232 ,
SNMP Web- .
Smartpack ,
.
:
o 8
(CON4 CON3)
o 2
(CON5 CON3)
o 2
(CON5 CON3)
o 2
(CON4 CON3)
o 1
(CON5)
o 6 (CON1
CON2)
o 6 (CON1 CON2)
– ,
Smartpack
.
,
,
.
, ,
,
.
,
, , ,
.
:
• ,
(type of input):
( , )
( ,
)
( , )
• (alarm monitor
activation). ,
.
• (type of alarm reset).
( , ,
).
• (Hysteresis and Time
Delay).
( )
.
,
.
" " (time delay).
.
: 57,
00 , 0, 10
, –2 .
57, 08
.
, 57, 10
,
.
• .
:
(
), –
(
).
( )
.
(
).
, ,
, .
• .
,
,
.
• .
. ,
, .
.
• .
.
.
.
,
.
. “ ”, . 25.
–
,
( ) (
(LVLD) (LVBD)
), .
Smartpack
: CON1 ( ) CON2 (
), .
,
.
. “ ”,
. 60.
:
.
).
“ 8” .
18”.
.
«
» (LVBD OG) «
» (LVLD1 OG)
2 (2AC
power shelves)
2 (
: ,
).
4 (4AC
power shelves)
4 (
: ,
).
AC
(Alarm Monitor)
– ,
Smartpack
.
,
,
.
, ,
.
PowerSuite
:
(
);
(
, .
);
(
( ) .)
. . 110,
« ».
(
–
,
( ) (
(LVLD) (LVBD)
), .
,
.
. . 112,
».
()
Windows
,
.
-
:
1.
.
.
2.
(delete), (backspace),
.).
, ESC « »
(Cancel) « »( ý)
.
3. “ " (Apply).
.
, ,
" " (Apply) “ ”.
« » (Cancel) « »(
ý )
.
,
.
,
.
(Ampere-hours, Ah)
, . (
1 ).
()
.
- ( )
( ). -
, -
,
.
: , 2
20 , 20 (2*20=40).
(battery block)
.
. . 86,
».
(Battery Boost
Charging)
–
,
.
,
, , ,
.
,
,
.
. . 86,
».
(Battery Capacity)
, ,
10- 25° .
, 200 10,
20 10
1,80 .
, ,
.
. . 86,
».
(Battery Cell)
,
.
. . 86,
».
(Battery Cut-off
Voltage)
.
.
, ( )
, , , -
.
. . 86,
».
(Battery Cycle)
– ,
( ).
– ,
. .
,
.
500 1000 .
. . 86,
».
,
.
,
, ,
,
, .
,
.
25°C
10 1,80
.
(Battery float
voltage)
,
.
. . 86,
».
(Boost
Voltage)
( ).
Aeon.
(Capacity)
, .
– ,
.
,
,
,
.
. “ ”, . 115.
(Cell mismatch)
(Cell reversal)
( ,
)
(Charge)
( -rate)
,
. , 1
1000 1000
. 1
.
0, 5 500
.
(Critical
Condition)
,
.
,
,
.
PowerSuite
( , ),
(Current-limiting
chargers)
,
,
.
(Cycle)
.
(Cycle life)
,
. ,
60 80% .
DC
(Delta Voltage)
– ,
,
.
PowerSuite
:
(Vdelta) –
, :V
/ 2) – V = | Vdelta |
0 ,
.
(Drop-down List)
Windows
, .
, .
, ,
.
1.
.
2. ,
,
.
3. .
,
.
.
, ,
" " (Apply) “ ”.
« » (Cancel) « »(
)
.
Eltek Energy
,
,
(End-of-Discharge
Voltage)
,
,
.
(End-Voltage Point ) –
.
, ,
(Energy)
, .
(Equalizing Charge)
.
,
.
Flatpack2
Eltek
Energy Smartpack
Flatpack2. Flatpack2
, .
(Float Charge)
. ,
. InstallShield Wizard
,
, , ,
PowerSuite, Windows.
InstallShield
Windows InstallShield
Software Corporation.
InstallShield Software Corporation
, ,
,
.
(Latching Contactor)
.
.
(
),
.
LVBD
.
,
,
.
LVD
.
,
,
.
LVLD
.
,
,
.
MCB
( ).
(Nominal voltage)
.
(overcharge)
,
.
.
OVP
(Over Voltage Protection).
OVS
(Over Voltage Shutdown).
,
.
Powerpack
PowerSuite
,
Flatpack2.
MS Windows XP.
PSS
REVP
. .
“ ”, . 119.
RS232
RS232 ( )
RS485
RS485 ( )
Smartpack
Flatpack2
Powerpack.
SNMP
.
(Trickle Charge)
, .
USB
[Intel]