Sunteți pe pagina 1din 25

All rights reserved 2005, Evolium

MXBSC PRESENTATION
Khalil-ur-Rehman
Summary
Page 2
G2 BSC Hardware Overview
MxBSC Software Architecture
MxBSC Hardware Presentation
MxBSC Functional Improvements
Evolution Capacity Improvements
G2 BSC Hardware Overview
Page 3
y Commonly in G2 BSC for Alcatel
there are three racks and each rack
contains eight shelves.
y There are eight shelves in one BSC
rack. Count starts from breakers shelf
at the top and ends at the last shelf in
the bottom.
G2 BSC Hardware Overview
Three main Terminal Sub Units (TSUs)
y Common TSU ( Within the BSC).
y Abis TSU ( BSC to BTS).
y ATER TSU ( BSC to Transcoder)
G2 BSC Hardware Overview
COMMON TSU
y In the common TSU the functions are carried out by the BSC. For
Example call initiation, call establishment and handovers etc.
y The card which comes in the common TSU domain is CPRC (cpra
card)
CPRC (Common Processor Type C)
y There are six cpra cards in the first rack of the Alcatel BSC.
y Two Cpra OSI (Open system interface). These are responsible for
establishing the link b/w BSC and the OMCR. IN short the these
two CPRC contain the OML of the BSC through X.25 link.
y Two Cpra Sis These are the main controller processors for the
BSC. The various functions are carried out through this card.
y Two Cpra Broadcast. Used for the local bus interface in the BSC.
G2 BSC Hardware Overview
ABIS TSU
y Abis Tsu is responsible for the link between the BTS and the BSC.
One Abis TSU contains one BIUA card and eight TCUC cards and
two access switches.
y
BIUA (BTS Interface Unit Type A)
y One BIUA contains six abis. Abis is the link between the BTS and
the BSC. Its a 2 MB link. One BIUA has eight TCUC cards.
TCUC (TRX Control Unit Type C)
y Basically TRX are configured on the TCUC cards.
y One TCUC can contain four full rate and two half rate TRX.
y TCUC also contain the OML for the site.
G2 BSC Hardware Overview
y ATER TSU
y One Ater TSU contains two ASMB cards, eight DTCC cards
and two access switches.
ASMB (Ater Sub Multiplexer at the BSC)
y One ASMB is one Ater mux.
y One DTCC (Digital trunk controller type C).
TSCA (Transmisson Submultiplexer ContollerType A)
y All the transmission cards are working under this important
card. Each rack contains this card at shelf eight and slot 5.
MxBSC Software Architecture
Page 8
y From G2BSC to MxBSC
y BSC application architecture
y MxPF Software
MxBSC Software Architecture
From G2BSC to MxBSC
Page 9
TCUC
TCUC
TCUC
TCUC
TCUC
TCUC
TCUC
TCUC
AS
DTCC
DTCC
DTCC
DTCC
DTCC
DTCC
DTCC
AS
DTCC
CPRC CPRC CPRC CPRC CPRC CPRC CPRC CPRC
AS
6 x
G.703
Abis
I/F
2 x
G.703
Ater
muxed
I/F
Abis TSU Ater TSU
Common Functions TSU
Group Switch
8 Planes
2Stages
TSL
ASMB
ASMB
Q1 bus
Broadcast bus
TSCA
BIUA
OMCP OMCP
SSW SSW
TP & LIU Shelf TP & LIU Shelf
CCP CCP
No more CPR broadcast:
the feature is emulated.
DTC TCH-RM does not
manage Ater anymore and
are moved on OMCP.
MxBSC Software Architecture
BSC application architecture
Page 10
y G2BSC Control Element (TCU, DTC, CPR, TSC) becomes MxBSC
Virtual Control Element (VTCU, VDTC, VCPR, VTSC)

O N P

licati ( / )
P
One E per G2 B r

Carrier Grade Linux
V S
DBCS
Application
(FMM/SSM)
PFM
MxPF
VC -1
Mx SC oard

CMW Boot
V S
DBCS
Application
(FMM/SSM)
PFM
VC -n
CMW Boot


BSC Porting


DBCS: G2 BSC Database Management System
MxPF: Mx Platform software
PFM: G2 BSC Platform Management
S D: G2 BSC perating System
PF: Platform drivers
V S Simulation of S D
MxBSC Software Architecture
MxPF Software
Page 11
> EndurX library manages the hardware environment via the
Hardware Platform Interface (HPI) based on IPMI software and
hardware standard.
AdvancedTCA (PICMG 3.x)
Carrier Grade Linux
Self reliant
EndurX
MxPF
Mx BSC applications
Adaptation Layer
> Self-Reliant provides the framework for developing
applications that deliver service availability into a
clustered distributed environment.
> MxPF is in charge of processes management,
hardware management, software management, init and
few basic services like traces or date synchronization.
MxBSC HARDWARE PRESENTATION
Page 12
y SSW
y OMCP
y CCP
y TP-GSM
y MUX
y LIU
MxBSC HARDWARE PRESENTATION
SSW Switch Board
Page 13
y SBL: SSW-HW 1&2
y Redundancy: 1+1
y Allows exchanges between all the elements of the platform and
external IP/Ethernet equipment:
y OMC-R physical interface
y CBC physical interface
y NEM terminal connection
y Second ATCA shelf connection
y External Alarm Box connection
MxBSC HARDWARE PRESENTATION
OMCP O&M Control Processing board
Page 14
y SBL: CP-HW, CP-LOG 1&2
y Redundancy: 1+1
y O&M Control Processing board based on ATCA technology
equipped with a permanent storage device.
In charge of managing the whole platform as system manager and
O&M applications.
y O&M - logical interface to the Operation and Maintenance Center
(OMC-R)
y VCPR: S-CPR & O-CPR software
y DTC TCH/RM
y TSC software
MxBSC HARDWARE PRESENTATION
CCP Control Processing board
Page 15
y SBL: CP-HW, CP-LOG 3, 4 & 5
y Redundancy: N+1
y Call Control Processing board based on ATCA technology used for
call control functions.
y Identical to OMCP board without Hard disk.
y VTCU: TCU software (50 per CCP)
y VDTC: DTC software (40 CS & 24 PS per CCP)
MxBSC HARDWARE PRESENTATION
TP-GSM Transmission Processing
board
Page 16
y SBL: TP-HW 1&2
y Redundancy: 1+1
y Provide telecom transmission /transport interfaces to the MX
platform.
y Configuration Management
y Performance Parameters Management
y HDLC termination
y SS7 termination
y NE1oE
y Q1
y Ring control
MxBSC HARDWARE PRESENTATION
MUX
Page 17
y SBL: ECU 1&2
y Redundancy: 1+1
y Multiplexing and de-multiplexing of up to 16 E1 streams (16 E1 each)
from the LIU boards
y Configuration management and supervision of the LIU boards
y 1 GbE interface
y NE1oE packing/unpacking to/from up to 32 physical entities (TPGSM
boards)
y Debug interface
MxBSC HARDWARE PRESENTATION
LIU
Page 18
y SBL: ETU 1 to 16
y No redundancy
y Connection of up to 16 physical E1 interfaces (Tx / Rx)
y Multiplexing and de-multiplexing of 16 E1 to/from the two MUX
boards
y LIU synchronization
y Communication with the MUX boards for LIU board configuration and
supervision
y Detection of LOS on any E1 connected and in use
MxBSC Functional Improvements
Page 19
y New dimensioning
y New switching connectivity
MxBSC Functional Improvements
New dimensioning
Page 20
fig rati T e 2
apacit N TR
N ell
N T
200
200
200
00
2
2
00
2
2
N f is
ter
ter PS

0


20
2

0

N P N T
N T S
N T PS
0
0
2
00
0

0
20
2
N O P N T H-R pairs
N PR pairs
N TSC pairs

2


2


2

N CE per ar N CE per CCP
N CE/O CP







Telecom traffic: from 1900 to 600 erlangs
MxBSC Functional Improvements
New switching connectivity
Page 21
MxBSC

CCP
TP
TCU DTC
Abis Ater
Signaling Signaling
Telecom Traffic Telecom Traffic
With MX BSC the CS and the PS traffics are
switched inside the TP
G2BSC

BI ASMB
TCU
Switc i
TC
Abi Ater
Signaling Signaling
Telecom Traffic Telecom Traffic
1 TCU = 32 BCI
1 FR TRE = 8 BCI
1 DR TRE = 16 BCI
1 EXTS = 4 BCI

1 TCU = 4 FR TRE
1 TCU = 2 DR TRE
1 TCU = 8 EXTS
With G2 BSC the CS and the PS traffics
goes through the TCU and DTC
Evolution Capacity Improvements
TRE/VTCU Mapping
HSL MODE
Evolution Capacity Improvements
TRE/VTCU Mapping
y In B10, the maximum number of TREs mapped on a VTCU is 4
whatever their type (FR/DR). A CCP board contains 50 VTCUs and
can manage upto 1500 TCHs
Evolution Capacity Improvements
y HSL MODE
y In B10, in LSL mode, the bandwidth is not wide enough to carry the
No.7 signaling in the case of large-capacity
y BSCs (that can support more than 600 TRXs). Therefore, the HSL
mode is implemented.
y
y In TDM mode, the HSL links are connected from the BSC to the
MSC without going through the TransCoder (TC).
y For redundancy purposes, 2 HSLs are used. The load is shared
between both HSLs.
Evolution Capacity Improvements
Page 25
HSL Engineering Rules
The HSL configuration requires 2 AterMux. Any AterMux can be
candidate if:
It does not carry Qmux.
It does not carry IP over Ater.
It is configured for CS traffic only.
The HSL and LSL modes cannot be mixed on a BSC.
The AterMux supporting HSL must be configured on different LIU
boards.

S-ar putea să vă placă și