3G Parameter Optimization

Cell Selection
Parameter ID : QqualMin
Value Range : -24...0
Step : 1
Unit : dB
Default Value : -18
Description : The minimum required quality level in
the cell (Ec/No).
NSN Cell Selection & Reselection Parameter
Parameter ID : QrxlevMin
Value Range : -119...-25
Step : 2
Unit : dB
Default Value : -115
Description : The minimum required RX level in the
cell.
Note: This parameter is also used to create value for
the parameter DeltaQrxlevmin to be sent in SIB3/4
when the used value is < -115.
NSN Cell Selection & Reselection Parameter
Parameter ID : Sintersearch
Value Range : 0...20
Step : 2
Unit : dB
Default Value : 8
Description : The threshold for inter-frequency
measurements, and for the HCS measurement rules.
NSN Cell Selection & Reselection Parameter
Parameter ID : Sintrasearch
Value Range : 0...20
Step : 2
Unit : dB
Default Value : 10
Description : The threshold for intra-frequency
measurements, and for the HCS measurement rules.
NSN Cell Selection & Reselection Parameter
Parameter ID : SsearchRat
Value Range : 0...20
Step : 2
Unit : dB
Default Value : 4
Description : The RAT-specific threshold for inter-RAT
measurement rules.
NSN Cell Selection & Reselection Parameter
Parameter ID : SintersearchCon
Value Range : 0...20
Step : 2
Unit : dB
Default Value : 8
Description : The parameter defines the threshold for inter-
frequency measurements and for the HCS measurement rules. The
value of the parameter should be between the values of the
parameters SintrasearchConn and SsearchRATConn, but high
enough to manage cell reselection. The parameter is used for cell
selection and re-selection in connected mode.
Note: The UE performs inter-frequency measurements continuously
when CPICH Ec/No is lower than or equal to QqualMin +
SintersearchConn. For example if QqualMin is -18 dB, the UE
performs inter-frequency measurements continuously when
Sintersearch value is 18 dB since CPICH Ec/No is always below 0 dB.
NSN Cell Selection & Reselection Parameter
Parameter ID : SintrasearchCon
Value Range : 0...20
Step : 2
Unit : dB
Default Value : 10
Description : The parameter defines the threshold for
intra-frequency measurements and for the HCS
measurement rules. UE will start the neighbouring
measurements when CPICH EcNo <
qualmin+SintrasearchConn (default: EcNo < -8 dB). The
parameter is used for cell selection and re-selection in
connected mode.
Note: If no threshold is given, MS performs
measurements.
NSN Cell Selection & Reselection Parameter
Parameter ID : SsearchRatCon
Value Range : 0...20
Step : 2
Unit : dB
Default Value : 4
Description : The parameter defines the RAT-specific
threshold for inter-RAT measurement rules. GSM
measurements will happen when it is not possible to
maintain a call with good quality: CPICH EcNo <
Ssearch_RATConn + Qqualmin (default: EcNo < -14 dB).
The parameter is used for cell selection and re-selection
in connected mode.
Note: If no threshold is given, MS performs
measurements.
NSN Cell Selection & Reselection Parameter
Parameter ID : Treselection
Value Range : 0...31
Step : 1
Unit : s
Default Value : 2
Description : The UE triggers the reselection of a new
cell if the cell reselection criteria are fulfilled during
the time interval Treselection.
NSN Cell Selection & Reselection Parameter
Parameter ID : TreselectionFACH
Value Range : 0...6.2
Step : 0.2
Unit : s
Default Value : 2
Description : This parameter is used for cell selection and re-
selection in Cell_FACH. The UE triggers the reselection of a
new cell if the cell reselection criteria are fulfilled during the
time interval TreselectionFACH. The reselection time of 2s
may avoid too many cell reselections between cells and hence
LA/RA updates when crossing the LA/RA border. Thus, there
are less signalling and less call failures at the LA/RA border
due to the LA/RA update. The reselection time of 0s can be
used in areas of high mobility, such as highways.
NSN Cell Selection & Reselection Parameter
Parameter ID : TreselectionPCH
Value Range : 0...31
Step : 1
Unit : s
Default Value : 2
Description : The parameter is used for cell selection and re-
selection in Cell_PCH/URA_PCH. The UE triggers the
reselection of a new cell if the cell reselection criteria are
fulfilled during the time interval TreselectionPCH. The
reselection time of 2s may avoid too many cell reselections
between cells and hence LA/RA updates when crossing the
LA/RA border. Thus, there are less signalling and less call
failures at the LA/RA border due to the LA/RA update. The
reselection time of 0s can be used in areas of high mobility,
such as highways.
NSN Cell Selection & Reselection Parameter
Parameter ID : qQualMin
Value Range : -24..0
Step : 1
Unit : dB
Default Value : -18
Description : Minimum required (acceptable) quality
level in the cell (dB). Used to set cell border between
two cells. Used in UE functions for cell
selection/reselection in idle mode and connected
mode.
EID Cell Selection & Reselection Parameter
Parameter ID : qRxLevMin
Value Range : -115..-25
Step : 2
Unit : dB
Default Value : -115
Description : Minimum required (acceptable) RX level
in the cell. Used in UE functions for cell
selection/reselection in idle mode and connected
mode. Value launched by System information (SIB11)
for each intra-frequency measurement object
corresponding to adjacent cells of serving cell.
EID Cell Selection & Reselection Parameter
Parameter ID : qualMeasQuantity
Value Range : CPICH_RSCP = 1, CPICH_EC_NO = 2
Step : -
Unit : -
Default Value : CPICH_EC_NO
Description : Used in UE functions for cell
selection/reselection in idle and connected mode.
Cell selection and reselection quality measure. Value
launched by System information (SIB3, SIB11 and
SIB12).
EID Cell Selection & Reselection Parameter
Parameter ID : sIntraSearch
Value Range : 0..27
Step : 2
Unit : dB
Default Value : 0
Description : The decision on when measurements on intra-
frequencies shall be performed.
Value mapping:
0 : not sent.
1 : -32 dB
2 : -30 dB
...
27 : 20 dB
EID Cell Selection & Reselection Parameter
Parameter ID : sInterSearch
Value Range : 0..27
Step : 2
Unit : dB
Default Value : 0
Description : The decision on when measurements on inter-
frequencies shall be performed.
Value mapping:
0 : not sent
1 : -32 dB
2 : -30 dB
...
27 : 20 dB
EID Cell Selection & Reselection Parameter
Parameter ID : sRatSearch
Value Range : -32..20
Step : 2
Unit : dB
Default Value : 4
Description : The decision on when measurements on GSM
frequencies shall be performed is made using this parameter
in relation with Squal.
If S_qual > this parameter, UE need not perform measurements
on GSM cells.
If S_qual <= this parameter, UE shall perform measurements on
GSM cells.
If a negative value is configured the UE interprets the negative
value as 0.
EID Cell Selection & Reselection Parameter
Parameter ID : sRatSearch
Value Range : -32..20
Step : 2
Unit : dB
Default Value : 4
Description : The decision on when measurements on GSM
frequencies shall be performed is made using this parameter
in relation with Squal.
If S_qual > this parameter, UE need not perform measurements
on GSM cells.
If S_qual <= this parameter, UE shall perform measurements on
GSM cells.
If a negative value is configured the UE interprets the negative
value as 0.
EID Cell Selection & Reselection Parameter
Parameter ID : sHcsRat
Value Range : -105..91
Step : 2
Unit : dB
Default Value : 3
Description : RAT specific threshold in the serving cell used in
the inter-RAT measurement rules.
This parameter is used by the UE to decide when to start GSM
measurements for cell reselection, if the serving cell is
indicated to belong to a Hierarchical Cell Structure (HCS)
GSM measurements in idle mode and state CELL_FACH are
started by the UE when RSCP <= qRxLevMin + sHscRat.
If sHcsRat is set to a negative value, this will be interpreted as 0
by the UE (according to 3GPP TS 25.331).
EID Cell Selection & Reselection Parameter
Parameter ID : treSelection
Value Range : 0..31
Step : -
Unit : s
Default Value : 2
Description : Control of cell selection/reselection.
Time-to-trigger for cell reselection.
Value launched by System information (SIB3).
EID Cell Selection & Reselection Parameter
Parameter ID : Qqualmin
Value Range : -24~0
Step : -
Unit : dB
Default Value : -18
Description : The minimum required quality threshold
corresponding to CPICH Ec/No. The UE can camp on the cell
only when the measured CPICH Ec/No is greater than the
value of this parameter. The higher the parameter value is,
the more difficult it is for the UE to reside in the cell. The
lower parameter value is, the easier it is for the UE to reside in
the cell, but it is possible that the UE cannot receive the
system messages that are sent through the PCCPCH. For
detailed information, refer to the 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : Qrxlevmin
Value Range : -58~-13
Step : 2
Unit : dBm
Default Value : -58
Description : Minimum RX level of the GSM cell.Before
the UE camps on the cell, take the measurement of the
signal quality in the cell. If the quality is better than this
parameter, this indicates that the cell can obtain better
QoS and the UE is allowed to camp on this cell.
Otherwise, the UE cannot obtain good QoS in this cell
and does not camp on the cell.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : IDLESINTERSEARCH
Value Range : -16~10, 127
Step : 2
Unit : dB
Default Value : 4
Description : Threshold for inter-frequency cell reselection in idle mode. When the
quality (CPICH Ec/No measured by UE) of the serving cell is lower than this
threshold plus the [Qqualmin] of the cell, the inter-frequency cell reselection
procedure will be started. This parameter is not configured when its value is 127.
The intra-frequency cell reselection has a priority higher than the inter-frequency
cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection
start threshold should be higher than the inter-frequency cell reselection start
threshold and inter-RAT cell reselection start threshold. If the cell reselection
threshold is set to a comparatively high value, the UE may frequently start cell
reselections, and the battery of the UE may be largely consumed. If the cell
reselection threshold is set to a comparatively low value, it is difficult for cell
reselections to be started, and the UE may not timely reside in the cells with good
quality, affecting the quality of communication between the UTRAN and the UE.
For detailed information, refer to 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : IDLESINTRASEARCH
Value Range : -16~10, 127
Step : 2
Unit : dB
Default Value : 5
Description : Threshold for intra-frequency cell reselection in idle mode. When the
quality (CPICH Ec/No measured by the UE) of the serving cell is lower than this
threshold plus the [Qqualmin] of the cell, the intra-frequency cell reselection
procedure will be started. This parameter is not configured when its value is 127.
The intra-frequency cell reselection has a priority higher than the inter-frequency
cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection
start threshold should be higher than the inter-frequency cell reselection start
threshold and inter-RAT cell reselection start threshold. If the cell reselection
threshold is set to a comparatively high value, the UE may frequently start cell
reselections, and the battery of the UE may be largely consumed. If the cell
reselection threshold is set to a comparatively low value, it is difficult for cell
reselections to be started, and the UE may not timely reside in the cells with good
quality, affecting the quality of communication between the UTRAN and the UE.
For detailed information, refer to 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : SSEARCHRAT
Value Range : -16~10, 127
Step : 2
Unit : dB
Default Value : 2
Description : Threshold for inter-RAT cell reselection. When the
quality (CPICH Ec/No measured by UE) of the serving cell is lower
than this threshold plus the [Qqualmin] of the cell, the inter-RAT
cell reselection procedure will be started. The optional IE RAT list of
cell selection and re-selection info in SIB3/SIB4 of system
information will be set null when the value of this parameter is 127.
The intra-frequency cell reselection has a priority higher than the
inter-frequency cell reselection and inter-RAT cell reselection, the
intra-frequency cell reselection start threshold should be higher
than the inter-frequency cell reselection start threshold and inter-
RAT cell reselection start threshold. For detailed information, refer
to 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : CONNSINTERSEARCH
Value Range : -16~10, 127
Step : 2
Unit : dB
Default Value : 4
Description : Threshold for inter-frequency cell reselection in connected mode.
When the quality (CPICH Ec/No measured by UE) of the serving cell is lower than
this threshold plus the [Qqualmin] of the cell, the inter-frequency cell reselection
procedure will be started. This parameter is not configured when its value is 127.
The intra-frequency cell reselection has a priority higher than the inter-frequency
cell reselection and inter-RAT cell reselection, the intra-frequency cell reselection
start threshold should be higher than the inter-frequency cell reselection start
threshold and inter-RAT cell reselection start threshold. If the cell reselection
threshold is set to a comparatively high value, the UE may frequently start cell
reselections, and the battery of the UE may be largely consumed. If the cell
reselection threshold is set to a comparatively low value, it is difficult for cell
reselections to be started, and the UE may not timely reside in the cells with good
quality, affecting the quality of communication between the UTRAN and the UE.
For detailed information, refer to 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : CONNSINTRAEARCH
Value Range : -16~10, 127
Step : 2
Unit : dB
Default Value : 5
Description : Threshold for intra-frequency cell reselection in connected mode.
When the quality (CPICH Ec/No measured by the UE) of the serving cell is lower
than this threshold plus the [Qqualmin] of the cell, the intra-frequency cell
reselection procedure will be started. This parameter is not configured when its
value is 127. The intra-frequency cell reselection has a priority higher than the
inter-frequency cell reselection and inter-RAT cell reselection, the intra-frequency
cell reselection start threshold should be higher than the inter-frequency cell
reselection start threshold and inter-RAT cell reselection start threshold. If the cell
reselection threshold is set to a comparatively high value, the UE may frequently
start cell reselections, and the battery of the UE may be largely consumed. If the
cell reselection threshold is set to a comparatively low value, it is difficult for cell
reselections to be started, and the UE may not timely reside in the cells with good
quality, affecting the quality of communication between the UTRAN and the UE.
For detailed information, refer to 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : TRESELECTIONS
Value Range : 0~31
Step : -
Unit : s
Default Value : 1
Description : If the signal quality (CPICH Ec/No measured by the UE) of a neighboring cell is better
than that of the serving cell during the specified time of this parameter, the UE reselects the
neighboring cell. It is used to avoid ping-pong reselection between different cells. Note that the
value 0 corresponds to the default value defined in the protocol.

Set the parameter as follows:
1. Ensure that the UE can reselect a cell when crossing the non-soft-switch area of the cell and that
the UE timely performs location updates, cell updates, or URA updates when necessary.
2. Ensure that the UE does not reselect a cell when it is in the soft-switch area of the cell. In this
way, the unnecessary location updates, cell updates, and URA updates are avoided.
3. Consider the difference between cells that cover different areas, for example the cells covering
highways and cells covering densely populated areas. TIf the parameter is set to a comparatively
low value, the ping-pong reselections may be caused. The parameter can be increased in populated
area and reduced in high-speed movement. If the parameter is set to a comparatively high value,
the cell reselection delay may become excessively high, and thus cell reselections may be affected.
For detailed information, refer to 3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : Treselectionsfach
Value Range : {0~6.2}, {255}
Step : -
Unit : 0.2s
Default Value : 255
Description : This parameter indicates the UE
reselection delay in the CELL_FACH connection
mode. This parameter is not configured when the
value is 255. Instead, the Treselections parameter is
used. For detailed information, refer to 3GPP TS
25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : Treselectionspch
Value Range : {0~31}, {255}
Step : -
Unit : s
Default Value : 255
Description : This parameter indicates the UE
reselection delay in the CELL_PCH or URA_PCH
connection mode. This parameter is not configured
when the value is 255. Instead, the Treselections
parameter is used. For detailed information, refer to
3GPP TS 25.304.
HUAWEI Cell Selection & Reselection Parameter
Parameter ID : QualMeas
Value Range : 1: CPICH Ec/No, 2: CPICH RSCP
Step : -
Unit : -
Default Value : 1: CPICH Ec/No
Description : This parameter indicates the
measurement quantity for cell selection and
reselection.
ZTE Cell Selection & Reselection Parameter
Parameter ID : SInterSearchPre
Value Range : 0: False, 1: True
Step : -
Unit : -
Default Value : 1: True
Description : This parameter is a switch which indicates
whether Sintersearch is configured or not. If the value is
False, Sintersearch is not configured to UE, and UE
performs the inter-frequency measurement periodically
according to the period inicated by the parameter
Treselections. If the value is True, Sintersearch is
configured to UE, and UE judges whether to perform the
inter-frequency measurement.
ZTE Cell Selection & Reselection Parameter
Parameter ID : SInterSearch
Value Range : [0, 20]
Step : 2
Unit : db
Default Value : 10
Description : This parameter indicates the inter-
frequency measurement triggering threshold for cell
reselection(Sintersearch) used by UE to judge whether
inter-frequency measurement should be performed.
When HCS is not used, if the quality of serving cell
exceeds Sintersearch, UE may choose to not perform
inter-frequency measurement; if the quality of serving
cell is not larger than Sintersearch or if Sintersearch is not
configured, UE performs inter-frequency measurement.
ZTE Cell Selection & Reselection Parameter
Parameter ID : SInterSearch
Value Range : [0, 20]
Step : 2
Unit : db
Default Value : 10
Description : This parameter indicates the inter-
frequency measurement triggering threshold for cell
reselection(Sintersearch) used by UE to judge whether
inter-frequency measurement should be performed.
When HCS is not used, if the quality of serving cell
exceeds Sintersearch, UE may choose to not perform
inter-frequency measurement; if the quality of serving
cell is not larger than Sintersearch or if Sintersearch is not
configured, UE performs inter-frequency measurement.
ZTE Cell Selection & Reselection Parameter
Parameter ID : SIntraSearch
Value Range : [0, 20]
Step : 2
Unit : db
Default Value : 14
Description : This parameter indicates the intra-
frequency measurement triggering threshold for cell
reselection (Sintrasearch) used by UE to judge whether
intra-frequency measurement should be performed.
When HCS is not used, if the quality of serving cell
exceeds Sintrasearch, UE may choose to not perform
intra-frequency measurement; if the quality of serving
cell is not larger than Sintrasearch or if Sintrasearch is not
configured, UE performs intra-frequency measurement.
ZTE Cell Selection & Reselection Parameter
Parameter ID : OtherRATInfoPre
Value Range : 0: False, 1: True
Step : -
Unit : -
Default Value : 1: True
Description : This parameter is a switch indicating
whether inter-RAT information parameters used for cell
reselection are configured or not. If the value is False,
inter-RAT information parameters are not configured to
UE, and UE performs the inter-RAT measurement
periodically according to the period inicated by the
parameter Treselections. If the value is True, inter-RAT
information parameters are configured to UE, and UE
judges whether to perform the inter-RAT measurement.
ZTE Cell Selection & Reselection Parameter
Parameter ID : SSearchRat
Value Range : [0, 20]
Step : 2
Unit : db
Default Value : 6
Description : This parameter is a switch indicating
whether inter-RAT information parameters used for cell
reselection are configured or not. If the value is False,
inter-RAT information parameters are not configured to
UE, and UE performs the inter-RAT measurement
periodically according to the period inicated by the
parameter Treselections. If the value is True, inter-RAT
information parameters are configured to UE, and UE
judges whether to perform the inter-RAT measurement.
ZTE Cell Selection & Reselection Parameter
Parameter ID : QQualMin
Value Range : [-24, 0]
Step : 1
Unit : db
Default Value : -18
Description : This parameter indicates the minimum
required quality level of the cell which satisfies the
condition of being selected or reselected by UE.
When the measurement quantity is CPICH Ec/No,
only the measured quality of the cell is over
Qqualmin can the cell be selected.
ZTE Cell Selection & Reselection Parameter
Parameter ID : QRxLevMin
Value Range : [-115, -25]
Step : 2
Unit : dBm
Default Value : -115
Description : This parameter indicates the minimum
required received power level of the cell which
satisfies the condition of being selected or reselected
by UE. When the measurement quantity is CPICH
RSCP, only the measured received power level of the
cell is over Qrxlevmin can the cell be selected.
ZTE Cell Selection & Reselection Parameter
HHO Trigger and Cancellation
Parameter ID : HHoEcNoThreshold
Value Range : -24...0
Step : 1
Unit : dB
Default Value : -12
Description : If the inter-frequency or inter-RAT (GSM) handover
caused by low measured absolute CPICH Ec/No is enabled, the UE
transmits an event 1F triggered measurement report to the RNC
when the CPICH Ec/No measurement result of an active set cell
becomes worse than or equal to an absolute CPICH Ec/No
threshold.
The parameter HHoEcNoThreshold determines the absolute CPICH
Ec/No threshold which is used by the UE to trigger the reporting
event 1F. When the measured CPICH Ec/No of all active set cells has
become worse than or equal to the threshold in question, the RNC
starts inter-frequency or inter-RAT (GSM) measurements in
compressed mode for the purpose of hard handover.
NSN HHO Trigger and Cancellation
Parameter ID : HHoEcNoCancel
Value Range : -24...0
Step : 1
Unit : dB
Default Value : -9
Description : If the inter-frequency or inter-RAT (GSM) handover caused by low
measured absolute CPICH Ec/No is enabled, the RNC starts the inter-frequency or
GSM measurement in compressed mode when all active set cells have triggered
the reporting event 1F for CPICH Ec/No. The RNC cancels the event 1F of an active
set cell if the CPICH Ec/No measurement result of the active set cell becomes
better than or equal to the threshold HHoEcNoCancel and the UE transmits the
corresponding event 1E triggered Measurement Report to the RNC.

Note that once the RNC has started the inter-frequency or inter-RAT (GSM)
measurement for the purpose of hard handover due to low measured absolute
CPICH Ec/No, the RNC does not break off the ongoing measurement, even if one or
more active set cells trigger the reporting event 1E for CPICH Ec/No.
NSN HHO Trigger and Cancellation
Parameter ID : HHoRscpThreshold
Value Range : -115...-25
Step : 1
Unit : dBm
Default Value : -105
Description : If the inter-frequency or inter-RAT (GSM) handover caused by
a low measured CPICH RSCP is enabled, the UE transmits an event 1F
triggered measurement report to the RNC when the CPICH RSCP
measurement result of an active set cell becomes worse than or equal to
an absolute CPICH RSCP threshold.

The parameter HHoRscpThreshold determines the absolute CPICH RSCP
threshold which is used by the UE to trigger the reporting event 1F. When
the measured CPICH RSCP of all active set cells has become worse than or
equal to the threshold in question, the RNC starts inter-frequency or inter-
RAT (GSM) measurements in compressed mode for the purpose of hard
handover.
NSN HHO Trigger and Cancellation
Parameter ID : HHoRscpCancel
Value Range : -115...-25
Step : 1
Unit : dBm
Default Value : -102
Description : If the inter-frequency or inter-RAT (GSM) handover caused by low
measured absolute CPICH RSCP is enabled, the RNC starts the inter-frequency or
GSM measurement in compressed mode when all active set cells have triggered
the reporting event 1F for CPICH RSCP. The RNC cancels the event 1F of an active
set cell, if the CPICH RSCP measurement result of the active set cell becomes
better than or equal to the threshold HHoRscpCancel and the UE transmits the
corresponding event 1E triggered measurement report to the RNC.

Note, that once the RNC has started the inter-frequency or inter-RAT (GSM)
measurement for the purpose of hard handover due to low measured absolute
CPICH RSCP, the RNC does not break off the ongoing measurement, even if one or
more active set cells trigger the reporting event 1E for CPICH RSCP.
NSN HHO Trigger and Cancellation
Parameter ID : INTERFREQCSTHD2DECN0
Value Range : -24~0
Step : -
Unit : db
Default Value : -14
Description : Ec/No threshold of triggering the inter-frequency measurement for CS services.
The threshold of triggering the inter-frequency measurement (namely, threshold of enabling the
compression mode) is a key parameter in the inter-frequency handover policy. The setting of this
parameter affects the proportion of the UEs in compression mode in a cell and the success rate of the hard
handover. To set this parameter, consider the following factors: moving speed of the UE and cell radius.
When Ec/No is used as the measurement quantity for CS services, the UE reports event 2D when the
measured Ec/No value is lower than the value of this parameter. Then, the RNC sends the signaling to
activate the compression mode and start the inter-frequency measurement.
For the UE moving at a speed of 5 km/h, the recommended threshold is -17 dB; for the UE moving at a
speed of 50 km/h, the recommended threshold is -14 dB; for the UE moving at a speed of 120 km/h, the
recommended threshold is -12 dB.
For the cell in which the UEs are moving at various speeds, set this parameter to -14 dB. The emulation
result shows that the call drop rate remains low for the UEs moving at a speed of 120 km/h when this
parameter is set to -14 dB.
Event 2D and event 2F are used to enable and disable the compression mode respectively. To enable the
compression mode earlier, increase the threshold of triggering event 2D; otherwise, decrease the
threshold of triggering event 2D. To prevent the frequent enabling and disabling of the compression mode,
increase the difference between the thresholds of triggering event 2D and event 2F.
Huawei HHO Trigger and Cancellation
Parameter ID : INTERFREQCSTHD2FECN0
Value Range : -24~0
Step : -
Unit : db
Default Value : -12
Description : Ec/No threshold of stopping the inter-frequency measurement for CS services.
The threshold of stopping the inter-frequency measurement (namely, threshold of disabling
the compression mode) is a key parameter in the inter-frequency handover policy. The
setting of this parameter affects the proportion of the UEs in compression mode in a cell and
the success rate of the hard handover. To set this parameter, consider the following factors:
moving speed of the UE and cell radius.
When Ec/No is used as the measurement quantity for CS services, the UE reports event 2F
when the measured Ec/No value is higher than the value of this parameter. Then, the RNC
sends the signaling to disable the compression mode and stop the inter-frequency
measurement.
Event 2D and event 2F are used to enable and disable the compression mode respectively. To
enable the compression mode earlier, increase the threshold of triggering event 2D;
otherwise, decrease the threshold of triggering event 2D. To prevent the frequent enabling
and disabling of the compression mode, increase the difference between the thresholds of
triggering event 2D and event 2F.
Huawei HHO Trigger and Cancellation
Parameter ID : INTERFREQCSTHD2DRSCP
Value Range : -115~-25
Step : -
Unit : dBm
Default Value : -95
Description : RSCP threshold of triggering the inter-frequency measurement for CS services.
The threshold of triggering the inter-frequency measurement (namely, threshold of enabling the
compression mode) is a key parameter in the inter-frequency handover policy. The setting of this
parameter affects the proportion of the UEs in compression mode in a cell and the success rate of the hard
handover. To set this parameter, consider the following factors: moving speed of the UE and cell radius.
When RSCP is used as the measurement quantity for CS services, the UE reports event 2D when the
measured RSCP value is lower than the value of this parameter. Then, the RNC sends the signaling to
activate the compression mode and start the inter-frequency measurement.
For the UE moving at a speed of 5 km/h, the recommended threshold is -100 dBm; for the UE moving at a
speed of 50 km/h, the recommended threshold is -97 dBm; for the UE moving at a speed of 120 km/h, the
recommended threshold is -93 dBm.
For the cell in which the UEs are moving at various speeds, set this parameter to -95 dBm. The emulation
result shows that the call drop rate remains low for the UEs moving at a speed of 120 km/h when this
parameter is set to -95 dBm.
Event 2D and event 2F are used to enable and disable the compression mode respectively. To enable the
compression mode earlier, increase the threshold of triggering event 2D; otherwise, decrease the
threshold of triggering event 2D. To prevent the frequent enabling and disabling of the compression mode,
increase the difference between the thresholds of triggering event 2D and event 2F.
When the signals at the entrance to an elevator or a subway change too fast to perform handover, set this
parameter to -90 dBm to enable the compression mode earlier.
Huawei HHO Trigger and Cancellation
Parameter ID : INTERFREQCSTHD2FRSCP
Value Range : -115~-25
Step : -
Unit : dBm
Default Value : -92
Description : RSCP threshold of stopping the inter-frequency measurement for CS services.
The threshold of stopping the inter-frequency measurement (namely, threshold of disabling
the compression mode) is a key parameter in the inter-frequency handover policy. The
setting of this parameter affects the proportion of the UEs in compression mode in a cell and
the success rate of the hard handover. To set this parameter, consider the following factors:
moving speed of the UE and cell radius.
When RSCP is used as the measurement quantity for CS services, the UE reports event 2F
when the measured RSCP value is higher than the value of this parameter. Then, the RNC
sends the signaling to disable the compression mode and stop the inter-frequency
measurement.
Event 2D and event 2F are used to enable and disable the compression mode respectively. To
enable the compression mode earlier, increase the threshold of triggering event 2D;
otherwise, decrease the threshold of triggering event 2D. To prevent the frequent enabling
and disabling of the compression mode, increase the difference between the thresholds of
triggering event 2D and event 2F.