Sunteți pe pagina 1din 2

Model

Item
Power
Consumption
DC24V Supply
Current*1
Power
Protection
Voltage
Withstand
Insulation
Resistance

2014-01-22

5011668404-XS05

DVPDVP14ES00 24ES00

Noise Immunity
Grounding
Environment

DVP60ES00

DVP20EX00

DVP24ES11

DVP20EX11

20VA

25VA

DVP30ES00

30VA

DVPDVP32ES00 40ES00

30VA

30VA

35VA

30VA

6.5W

8W

400mA

400mA

400mA

400mA

400mA

400mA

400mA

DC24V output short circuit

DC24V input polarity


Below 6.2

1,500 VAC (Primary-secondary), 1,500V AC (Primary-PE), 500V AC (Secondary-PE)


> 5 M at 500V DC (Between all inputs/outputs and earth)
ESD: 8KV Air Discharge
EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
RS: 26MHz ~ 1GHz, 10V/m
The diameter of grounding wire cannot be smaller than the wire diameter of terminals L and N (All DVP
units should be grounded directly to the ground pole).
Operation: 0C ~ 55C (temperature), 5 ~ 95% (humidity), Pollution degree2
Storage: -25C ~ 70C (temperature), 5 ~ 95% (humidity)

Output Point Electrical Specifications


Relay-R
Transistor-T
55C 0.1A/1point, 50C 0.15A/1 point
2A/1 point (5A/COM)
45C 0.2A/1 point, 40C 0.3A/1 point (2A/COM)
Below 250V AC, 30V DC
30V DC
75VA (Inductive)
9W/1 point
90W (Resistive)
About 10ms
Off On 20us, On Off 30us

Output Point Type


Current Specification
Voltage Specification
Maximum Load
Reaction Time

AD/DA Specifications
Analog I/O Range
Digital Conversion
Range
Resolution
Input Impedance
Output Impedance
Tolerance Carried
Impedance

Analog Output (D/A)


Voltage Output
Current Output
0 ~ 10V
0 ~ 20mA

-512 ~ +511

-512 ~ +511

0 ~ 255

0 ~ 255

10 bits
(1LSB = 19.53125 mV)
> 112 K

10 bits
(1LSB = 39.0625 A)
250

8 bits
(1LSB = 39.0625 mV)

8 bits
(1LSB = 78.125 A)

0.5or lower

1K~2M

Reaction Time
Absolute Input Range
Digital Data Format
Average Function
Isolation Method
Protection

Analog Input (A/D)


Voltage Input
Current Input

Items

0500

56K
V+

VGro u ndi ng

56K
Current input
-20mA~+20mA

28K
I+

I+

CH 3 CH 1

28K

Fuse

X0

X1

24VDC

X2

OV

+24V 24G

S/S

DVP30ES00

X0

X1

100 ~ 240V AC (-15% ~ 10%), 50/60Hz 5%


The PLC start to operate at power supply of 95 ~ 100V AC. If the voltage of
power supply drops to 70V AC, the PLC will stop. Maximum power loss time is
10ms or less.
2A/250V AC

DVP24ES11

Maximum power loss


time is 5ms or less.
2A/250V AC

10.

3.

11.

4. (RS-232C)

12.

5.

13.

6.

14.

7.

15. RS-485

8.

MC

24VDC

OV

H1
95

W
99

W1
104

W2
82

DVP24ES00[11]R2/T2

100

95

150

155

82

DVP30ES00R2/T2

100

95

150

155

82

24VDC

20VA

25VA

30VA

30VA

30VA

35VA

30VA

6.5W

8W

400mA

400mA

400mA

400mA

400mA

400mA

400mA

DVP14ES00

DVP24ES00

DVP30ES00

DVP32ES00

DVP40ES00

DVP60ES00

DVP20EX00

DVP24ES11

DVP20EX11

DC24V

5M / 500V DC

EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
RS: 26MHz ~ 1GHz, 10V/m

+24V

S/S

24G

X0

X1

X2

SOURCE
24VDC

L, N PLC

0C ~ 55C5 ~ 95% 2
-25C ~ 70C 5 ~ 95%

IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

Wiring Loop
(,g)

+5V

24G

400

552

580

C1 Y4 Y5

Y6

Y7

9
1
MC2

MC1

95

150

155

82

95

150

155

82

DVP60ES00R2/T2

90

85.5

180.5

185

89.6

DVP20EX00[11]R2/T2

100

95

150

155

82

10

24G

S/S

X0

X1

X2

4
7

c Surge absorbing diode: increases relay contact life


d Emergency stop: use an external switch
Fuse: use the fuse with a 5 ~ 10A capacity at the
e common end of the output contact to protect the
output circuit.
f Surge absorber: reduces noise on AC inductive loads
g Unused terminal: do not connect
h DC supply
i Indicator: neon indicator
j AC supply
k Incandescent lamp (resistive loading)
Mutually exclusive outputs: use external hardware
l interlocks, as well as those in the PLC program, for
maximum safety.

Practical Transistor Output Wiring

C0 Y0

Y1 C1 Y 4 Y5
MC1

7
Y6

Y7

MC2

1
2
3

c
d
e
f

DC supply
Emergency stop
Fuse for circuit protection
As all outputs of the transistor modules are Open
Collectors, if the setting of Y0 is pulse train output
(using PLSY instruction), its pull-up resistor must
remain an output current of greater than 0.1A for
normal operation of the transistor modules.

g As all outputs of the transistor modules are Open

Type2:
4

5
Up1 Zp1 Y1

6
Up2 Zp2

Y3

MC1

Y4

MC2

Collectors, if the setting of Y1 is pulse train output


(using PWM instruction), its pull-up resistor must
remain an output current of greater than 0.1A for
normal operation of the transistor modules.

h Mutually exclusive outputs: use external hardware


interlocks, as well as those in the PLC program, for
maximum safety.

2
3
3

750

SINK SOURCE

24V DC

Off OnX0X118.5V DC X2 ~ X4316.5V DC

536

414

386

i Unused terminal: do not connect


j Type 2 is only applicable to 30ES00T2.

5mA

On Off8V DC
10ms D1020 D1021 0 ~ 15ms

-R

-T

2A/1 5A/COM

250V AC,30V DC

Type1:
4

596


+24V

100

580

*1HMI

S/S

100

1,500V AC (Primary-secondary)1,500V AC (Primary-PE)500V AC (Secondary-PE)

S/S

ESD: 8KV Air Discharge

+5V

24G

C0 Y0 Y1

SINK

+24V

DVP20EX11

2A/250V AC

DVP40ES00R2/T2

> 50mm

DVP24ES11

2A/250V AC

The input signal of the input point is the DC power DC input. There are two types of DC type wiring: SINK and
SOURCE, defined as follows:
Wiring
Input Point Loop Equivalent Circuit
Wiring Loop

DVP32ES00R2/T2

DIN rail installation:


The DVP-PLC can be secured to a cabinet by using the DIN rail that is 35mm high with a depth of 7.5mm.
When mounting the PLC on the DIN rail, make sure to use the end bracket to stop any side-to-side motion of
the PLC; thus to reduce the chance of the wires being pulled loose. On the bottom of the PLC is a small
retaining clip. To secure the PLC to the DIN rail, place it onto the rail and gently push up on the clip. To remove
it, use a slotted screwdriver, place it on the groove of the retaining clip and press gently, then pull down on the
retaining clip and gently pull the PLC away from the DIN rail.
For heat dissipation, make sure to provide a minimum clearance of 50mm
> 50mm
between the unit and all sides of the cabinet. (See the figure.)
Direct mounting: Use the specified dimensions and install with M4 screws.
DVP MPU

DVP20EX00

5ms

DVP60ES00

95 ~ 100V AC PLC 70V AC


PLC 10ms

DVP40ES00

Input / Output Point Wiring

Practical Relay Output Wiring

H
100

DVP32ES00

24V DC (-15% ~ 10%)

DC24V
*1

+24V

Model Name (mm)


DVP14ES00R2/T2

DVP30ES00

100 ~ 240V AC (-15% ~ 10%), 50/60Hz 5%

DC Type
(DC Signal IN)
SOURCE Mode

W2

DVP24ES00

Input Point Loop Equivalent Circuit

DVP

DVP14ES00

DVP20EX11

24V DC (-15% ~
10%)

9.

2. DIN (35mm)

Up0 Zp0 Y0

DVP20EX00

1. DIN

Since the PLC is in control of numerous devices, operation of either one device could affect the operation of
other devices, therefore the breakdown of either one device would consequently be detrimental to the whole
auto control system, and danger will thus be resulted. Please use the recommended wiring below for the
power input:
c Power supply for AC loads
d Fuse for circuit protection (3A Limit)
e Power On pilot indicator
f Emergency stop: PLC must provide a quick manual method to
disconnect all system power.
g Circuit isolation device (System Power Disconnect): Use the
MC
electromagnetic contactor and the relay as the isolation unit of the
power circuit to prevent the possible instability of the system when
the power is supplied on and off.
L
N
h DVP PLC MPU (main processing unit)
i Grounding resistance: 100 or less
j Power supply: AC: 100 ~ 240V AC, 50/60Hz, DC: 24V DC

> 50mm

DVP60ES00

/ 128 //

X2

Sink Ty pe

> 50mm

DVPDVP32ES00 40ES00

DVP-ES/EX ES/EX 14 ~ 60 8 ~ 32

5V

DC/DC

X0

W1
W

2.5A

5V

DC/DC

3.1 Dimensions

Operation
Specification

S/S

24G

DC Type
(DC Signal IN)
SINK Mode

Z Installation & Wiring

H1

9. Input/Output
10. Status indicators: POWER, RUN, and ERROR
11. Input/Output terminal cover
12. Input/Output terminal cover
13. Input/Output terminal nameplate panel
14. Input/Output terminal nameplate panel
15. RS-485 communication port

Y Specifications
Item
Power Supply
Voltage

Groundi ng

3.2 Mounting & Installation

DVPDVP14ES00 24ES00

L
2.0A

Source Type

1. DIN rail clip


2. DIN rail (35mm)
3. Direct mounting holes
4. Communication Ports Cover (RS-232C)
5. Extension port indicators
6. Input/Output terminals
7. Input/Output terminals
8. Input / Output indicators

I-

I-

Grounding

AC d ri ve

Current outp ut 0mA~2 0mA

250

(OPEN TYPE) /

20VDC~26VDC

100 ~240VAC

X0

Product Profile and Outline

Model

There are two power inputs provided in DVP series PLC, AC input and DC input. Please pay particular attention
to the following notes:
1. Connect the AC input (100 ~ 240V AC) to terminals L and N. Any AC110V or AC220V connected to the
+24V terminal or input points will permanently damage the PLC.
2. The AC power inputs for the MPU and the I/O Expansion Unit should be ON or OFF at the same time.
3. Please use wires of 1.6mm or above for the grounding of the MPU.
4. If the power-cut time is less than 10ms, the PLC still operates unaffectedly. If the power-cut time is too long
or the power voltage drops, the PLC will stop operating and all the outputs will be OFF. Once the power is
restored, the PLC will return to operate automatically. (There are latched auxiliary relays and registers
inside of the PLC, please be aware when programming.)
5. The +24V supply output is rated at 0.4A from MPU. DO NOT connect external power supply to this terminal.
Moreover, it takes 5 ~ 7mA to drive each input point, so total of 100mA is needed for 16 input points. As a
result, the output loads of +24V should not exceeds 300mA.
6. When DC voltage is supplied to the PLC, ensure the power is at terminals 24V DC and 0V (power range is
20.4 ~ 26.4V DC). When the voltage is lower than 17.5V DC, PLC will stop operating, all outputs will turn
OFF and the ERROR LED will flash continuously.
AC Input Type
DC Input Type

V+

CH 0 CH 0

V-

Groundi ng

X Introduction
Thank you very much for choosing Deltas DVP-ES/EX series PLC. DVP-ES/EX series provides MPU with 14 ~
60 points and 8 ~ 32 points of extension. The maximum I/O points including those on the MPU can reach 128
points. DVP-ES/EX can be used for various applications with its different I/O points, power supply and digital I/O
extension modules.

DVP-PLC

Power Input Wiring

Guard
Limit

Vol ta ge outp ut 0V~1 0V

-10V~+10V

External Wiring

3 SS

3.3 Wiring Notes

Analog Output (D/A)


Voltage Output
Current Output

Voltage input

ENGLISH

Non-linear accuracy: 0.5% of full scale within the range of PLC operation temperature
Maximum deviation: 1% of full scale at 20mA and +10V
2ms channels
15V
32 mA
2s complementary of 16-bit, 10 Significant Bits 2s complementary of 16-bit, 8 Significant Bits
Provided
Isolation between digital area and analog area. But no isolation among channels.
Voltage output has short circuit protection but a long period of short circuit may cause internal
wire damage and current output break.

Overall Accuracy

Safety Wiring

Analog Input (A/D)


Voltage Input
Current Input
10V
20mA

Items

Warning

Below 6.2

To suit M3.5 screw terminals

Vibration /
Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
Shock
Resistance
Weight (g)
400
552
580
580
596
750
536
414
386
*1: It is suggested that the power output should not be supplied to HMIs.
Input Point Electrical Specifications
Input Point Type
Digital Input
Input Type
DC (SINK or SOURCE)
Input Current
24VDC 5mA
Off On, X0, X1: 18.5V DC and above
Active Level
X2 ~ X43: 16.5V DC and above
(Analog input resolution)
On Off, X0 ~ X43 below 8V DC
About 10ms (An adjustment range of 0 ~ 15ms could be selected through D1020 and
Reaction Time
(Conversion Sampling Time) D1021)

EN a DVP-ES/EX is an OPEN-TYPE device. It should be installed in a control cabinet free of airborne dust, humidity,
electric shock and vibration. To prevent non-maintenance staff from operating DVP-ES/EX, or to prevent an
accident from damaging DVP-ES/EX, the control cabinet in which DVP-ES/EX is installed should be equipped
with a safeguard. For example, the control cabinet in which DVP-ES/EX is installed can be unlocked with a
special tool or key.
EN a DO NOT connect AC power to any of I/O terminals, otherwise serious damage may occur. Please check all wiring
again before DVP-ES/EX is powered up. After DVP-ES/EX is disconnected, Do NOT touch any terminals in a
on DVP-ES/EX is correctly grounded in order to prevent
minute. Make sure that the ground terminal
electromagnetic interference.
FR a DVP-ES/EX est un module OUVERT. Il doit tre install que dans une enceinte protectrice (boitier, armoire, etc.)
saine, dpourvue de poussire, dhumidit, de vibrations et hors datteinte des chocs lectriques. La protection
doit viter que les personnes non habilites la maintenance puissent accder lappareil (par exemple, une cl
ou un outil doivent tre ncessaire pour ouvrir a protection).
FR a Ne pas appliquer la tension secteur sur les bornes dentres/Sorties, ou lappareil DVP-ES/EX pourra tre
endommag. Merci de vrifier encore une fois le cblage avant la mise sous tension du DVP-ES/EX. Lors de la
dconnection de lappareil, ne pas toucher les connecteurs dans la minute suivante. Vrifier que la terre est bien
afin dviter toute interfrence lectromagntique.
relie au connecteur de terre

1. Please use O-type or Y-type terminals for I/O wiring terminals. The specification
for the terminals is shown as the figure on the left. PLC terminal screws should be
tightened to between 5 ~ 8 kg-cm (4.3 ~ 6.9 in-lbs). Only can use 60/75C copper
conducting wire.
2. DO NOT wire to the No Function terminals . I/O signal wires or power supply
should not run through the same multi-wire cable or conduit.
3. When tightening the screws and performing the wiring, please avoid that metallic
particles fell into PLC. After completing wiring, please remove the label which is
used to obstruct the metallic particles on the ventilation hole for well heat
dissipation.

55C 0.1A/1 50C 0.15A/1


45C 0.2A/1 40C 0.3A/1 2A/COM
30VDC

75VA

9W/1

90W
10 ms

Off On 20usOn Off 30us

AD/DA

(A/D)

10V

20mA

0 ~ 10V

0 ~ 20mA

-512 ~ +511

-512 ~ +511

0 ~ 255

0 ~ 255

10 bits
(1LSB = 19.53125 mV)

10 bits
(1LSB = 39.0625 A)

8 bits
(1LSB = 39.0625 mV)

112 K

250

(D/A)

8 bits
(1LSB = 78.125A)
-

0.5or lower
1K ~ 2M
1%
1% 20mA +10V
2ms

0 ~ 500

(A/D)

(D/A)

15 V

16 2 10 bits

32 mA

CH0

CH0

24G

S/S

X0

X1

X2

Sink Ty pe

28K

CH3

I+

I+

CH1

I-

250
I-

DC Signal IN

28K

SOURCE

+24V

24VDC

+24V

S/S

24G

3.1

400mA

400mA

400mA

X0

X1

X2

H1

c
d
e 5~10A

DVP

5
C0 Y0 Y1

(mm)

H1

W1

W2

95

99

104

82

DVP24ES00[11]R2/T2

100

95

150

155

82

DVP30ES00R2/T2

100

95

150

155

82

DVP32ES00R2/T2

100

95

150

155

DVP40ES00R2/T2

100

95

150

155

82

DVP60ES00R2/T2

90

85.5

180.5

185

89.6

DVP20EX00[11]R2/T2

100

95

150

155

82

C1 Y4 Y5 Y6

MC1

10
4
7

82

c
d
e
f

Y1 C1 Y 4 Y5
MC1

DIN 35mm DIN

7
Y6

Y7

MC2

1
2

Up0 Zp0 Y0

50mm

DVP MPU

50mm

Y4

MC1

MC2

3. PLC

3.3

PLC

5 ~ 8 kg-cm (4.3 ~ 6.9 in-lbs) 60/75C

3. PLC

6.8mm

PLC

3.3

1. 100 ~ 240V AC LN AC110V AC220V

/
/

IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)
400

552

580

580

DVP PLC
+24V PLC

596

750

536

2. I/O On Off

414

386

*1HMI

SINK SOURCE

24V DC 5mA

3. 1.6mm
4. 10ms PLC PLC
OffPLC PLC

5. +24V 0.4A 5 ~ 7mA


16 100mA+24V 300mA
6. PLC 24V DC 0V 20.4 ~ 26.4V DC

Off OnX0X118.5V DC X2 ~ X4316.5V DC

17.5V DC PLC OffERROR LED

On Off8V DC

10ms D1020 D1021 0 ~ 15ms


20 VDC~ 2 6V DC

100~240VAC

250V AC, 30V DC

X1

30V DC
9W/1

90 W
10 ms

c
d
e
f

(A/D)

DVP-PLC

(D/A)

10V

20mA

0 ~ 10V

0 ~ 20mA

-512 ~ +511

-512 ~ +511

0 ~ 255

0 ~ 255

10 bits
(1LSB = 19.53125 mV)

10 bits
(1LSB = 39.0625A)

8 bits
(1LSB = 39.0625mV)

8 bits
(1LSB = 78.125A)

250

112 K

1K ~ 2M

0 ~ 500

1%
1% 20mA +10V

(A/D)

15V

16 2 , 10 bits

MC
1

24VDC

OV

h
i
j

DC DC SINK SOURCE

32mA

S/S

SINK

+5V

24G

X0

+24V

V+
CH0

CH0

0V~10V
56K
V+

56K
28K

I+

CH1

CH3

I+

I-

250

24VDC

X0

+24V

C0 Y0 Y1

2
3

C1 Y4 Y5

Y6

Y7

9
1

H1

X1

X2

MC1

MC2

DV P

10
2

W2

4
7

2 4VDC

OV

+24V

24G

S/S

X0

X1

X2

DC/DC

(mm)

5V

1. DIN

9. /

2. DIN 35mm

10.

3.

11.

PLC

4. RS-232C

12.

5.

13.

5
1
4

MC

c
d
e
f

Guard
Limit

g
MC
1

OV
6

H1

W1

DVP14ES00R2/T2

100

95

99

104

W2
82

DVP24ES00[11]R2/T2

100

95

150

155

82

DVP30ES00R2/T2

100

95

150

155

82

2.5A

5V

DC/DC

7
6

h
i
j

3A

DVP PLC
100

AC100 ~ 240V AC, 50/60Hz


DC24V DC


DC DC SINK SOURCE
DC DC SINK SOURCE

X0

c
d
e 5~10A

20VDC~ 26V DC

X0

S/S

3.1

W1
W
S/S

24G

Source Type

24G

X2

+5V

S/S

Z!

17.5V DC PLC OffERROR LED

X1

28K

6. PLC 24V DC 0V 20.4 ~ 26.4V DC

X2

24G

SOURCE

I-

16 100mA+24V 300mA

2.0A

X1

SOURCE

+24V

DC Signal IN

0mA~20mA


-20mA~ +20mA

X0

V-

V-

5. +24V 0.4A 5 ~ 7mA

100~240VAC

S/S

24G

Sink Ty pe

SINK

24VDC

DC Signal IN

16 2 , 8 bits

-10V~ +10V

X2

2ms

X1

3A

DVP PLC
100

AC100 ~ 240VAC, 50/60Hz


DC24V DC

+24V

X0

5V

DC DC SINK SOURCE

(D/A)

(OPEN TYPE)

/ 128 //

MC

0.5or lower

Guard
Limit

j 30ES00T2

3 SS

S/S

24G

DC/D C

Off On 20usOn Off 30us

+24 V

AD/DA

OV

PLC

75VA

24 VDC

X2

2.5A

-T

X0

5V

DC/DC

55C 0.1A/1 50C 0.15A/1


45C 0.2A/1 40C 0.3A/1 (2A/COM)

2A/1 (5A/COM)

S/S

24G

2.0A

-R

DVP-ES/EX ES/EX 14 ~ 60 8 ~ 32

24VDC

2.

M3.5

0C ~ 55C ()5 ~ 95%() 2


-25C ~ 70C ()5 ~ 95%

2. I/O On Off

L, N PLC

3. 1.6mm
OffPLC PLC

400mA

4. 10ms PLC PLC

400mA

1. (100 ~ 240V AC
LN AC110V AC220V +24V

400mA

DVP PLC

400mA

(Open
Collector) Y0 ( PLSY
)
0.1A

PLC

1. / O Y PLC

5 M / 500VDC

h PLC

5 ~ 8 kg-cm (4.3 ~ 6.9 in-lbs) 60/75C

Y3

50mm

1. O Y PLC

2.

6
Up2 Zp2

M4

Collector) Y1 PWM

0.1A

50mm

PLC

6.8mm

Up1 Zp1 Y1

DVP20EX11

1,500V AC (Primary-secondary)1,500V AC (Primary-PE)500VAC (Secondary-PE)

g (Open

PLC

PLC

3.2

6.8mm

f
g
h
i
j
k
l

MC2

C0 Y0

M3.5

Y7

9
1

100

DVP24ES11

DVP14ES00R2/T2

DVP20EX00

DC24V

Source Type

W2

DVP60ES00

6.8mm

(,g)

S/S

X0

W1
W

DVP40ES00

ESD: 8KV Air Discharge


EFT: Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 250V
RS: 26MHz ~ 1GHz, 10V/m

+5V

24G

SOURCE

DVP32ES00

0mA~20mA

+24V

V-

56K
-20mA~+20mA

S/S

X0

V-

DVP30ES00

+5V

V+

56K
V+

DVP24ES00

24G

0V~10V

-10V~+10V

24VDC

SINK

DVP14ES00

SINK

+24V

DC Signal IN

DC24V
*1

16 2 8 bits

6.

14.

7.

15. RS-485

DVP32ES00R2/T2
DVP40ES00R2/T2

8.

DVP14ES00

100

95

150

DVP60ES00R2/T2

90

85.5

DVP20EX00[11]R2/T2

100

95

155

DVP30ES00

DVP32ES00

DVP40ES00

DVP60ES00

DVP20EX00

DVP24ES11

DVP20EX11

100 ~ 240VAC (-15% ~ 10%), 50/60Hz 5%

24V DC (-15% ~ 10%)

5ms

2 /250V AC

2A/250V AC

25VA

30VA

30VA

30VA

35VA

30VA

155

82

180.5

185

89.6

150

155

82

8W

7
Y6

Y7

MC2

c
d
e
f

2
3
3

PLC

50mm

50mm

DVP MPU

50mm

50mm

5
Up1 Zp1 Y1

(Open Collector) Y0
( PLSY )

0.1A
( PWM )

0.1A

6
Up2 Zp2

Y3

Y4

MC1

MC2

h PLC

2
3
3

PLC

g (Open Collector) Y1
4

M4

6.5W

82

35mm DIN

PLC

Y1 C1 Y 4 Y5
MC1

DIN
DVP24ES00

95 ~ 100V AC PLC 70V AC PLC


10ms

20VA

150

4
C0 Y0

Up0 Zp0 Y0

95

3.2

Y !

100

f
g
h
i
j
k
l

30ES00T2