Sunteți pe pagina 1din 2

B777 “Non Customized Manual” © Ing. M.

Sommerbauer
REV 0- 11.DEZ/2009 OS-TDM CC
For Information only- no update!

SRM – General

1.) Effectivity Code, Line Number, S/N, Model Series and Registration :
Can be found in Manual Front Matter/Effective Aircraft.
2.) Identification of damaged part:
From page 1-99 in the relevant chapter (52 to 57) in the “Identification” part.
3.) Damage classification:
Scratch/Kratzer, gouge/Furche; Fuge, mark/Abdruck, nick/Ausbruch; Kerbe.

52- DOORS:
- Material thickness of Pax Door skin: Chapter 52-10-01-0I-1p1ff (“Identification”);
Drawings and Figures of machined door skin plates.
- Allowable damage in skin of Crew/Pax doors: Chapter 52- 10-01-1A-1 (“Allowable”);
Figure 102- Allowable damage 1.
For dents important: A/Y>over factor 30, where Y=3,175mm maximum depth and
A=101,6mm width or less! Same on all Entry doors.
- Material thickness of large Cargo Door skin: Chapter 52-30-01-0I-1p1ff
(“Identification”);
- Allowable damage in skin of large Cargo door: Chapter 52- 30-01-1A-1 (“Allowable”);
Figure 102- Allowable damage 1, page 107.
For dents important: A/Y>over factor 30, where Y=3,175mm maximum depth and
A=101,6mm width or less!
- Material thickness of small Cargo Door skin: Chapter 52-30-01-0I-2p1ff ;
Allowable damage same procedure as above.
- Material thickness of bulk Cargo Door skin: Chapter 52-30-01-0I-3p1ff ;
Allowable damage same procedure as above.
- Access Doors: 52-40-01-1A-1, respective “Allowabe” damage limits.
For dents factor W/Y=30 or more, where depth Y=3,18mm maximum! Length is in relation to
factor 30.

1
B777 “Non Customized Manual” © Ing. M. Sommerbauer
REV 0- 11.DEZ/2009 OS-TDM CC
For Information only- no update!

- Access Doors Composite: 52-40-01-1A-2; Tapping test required. Allowable damage


limits of Figure 103/ALLOWABLE DAMAGE 2, Temporary protection with Hi-speed
tape.

- Fixed interiour doors: 52-50-02-1A-1; Enhanced security flight deck door. Different
zones, damage only in the decorative laminate and in Zone 1 permitted (NO cracks, dents
or holes allowed! See Fig. 102, 52-50-02p104ff).

- Landing gear doors:


52-80-01

53- FUSELAGE:
53-00-01-1A-1; Allowable damage pg.104ff; dents W/Y=30 or more; lightning strike see
Fig. 102- Table A.

54- NACELLES/PYLONS:

55- STABILZERS:

56-WINDOWS:
Delamination limit 3,5” (89mm) from the edge; AMM SUBTASK 56-11-00-300-001.