Sunteți pe pagina 1din 1

No.

PumpName Quantity
Fluid
Name
RPM Cap. Head Eff.
BreakHorse
Power
Ph/Hz/Volt
Intern
alDia.
Actual
Velocity
Pump
Elev.
Wtr
Elev.
Length
Viscosityat
20degC
Vpat20degC
(absolute)
Reynold
Number
PipeLoss
Ceoff.
Fitting
Loss
Ceoff.
NPSHA
Specific
Speed
Operation Type Remark
Di V Z h L Vp Re f K n
s
l/m m kw mm m/s m m m Pa.s Pa m
1
ElectricFire
Pump
1 Water 2950 2839 90 50 83.23 3/50/380 202.8 1.47 0.00 0.00 5.00 0.0010020 2.338E+03 295989 0.00398 2.00 9.850 1134
Single
Alternate
Centrifugal
EndSuction
2
DieselFire
Pump
1 Water 2950 2839 90 50 202.8 1.47 0.00 0.00 5.00 0.0010020 2.338E+03 295989 0.00351 1.79 9.878 1134
Single
Alternate
Centrifugal
EndSuction
3 JoykeyPump 1 Water 2950 151 100 50 4.93 3/50/380 40.9 1.92 0.00 0.00 5.00 0.0010020 2.338E+03 78178 0.00459 1.81 9.353 968
Single
Alternate
VerticalMulti
Stage
Assume4
stage
ReferenceSpec.: Piping&ProcessSpecification Engineer: TJ O
MIANGBESARCOALTERMINAL
CALCULATIONFORFIREPROTECTIONPUMP
Doc.No.:
Job.No.:
TTE033
Rev.No.:
A0
Date: 09-Oct-14
D:\TTE033MBCT\CALCULATION\EXCEL&WORD\TTE03370010101A3_FireProtection.xlsm Page1