Newton's method power flow converged in 3 iterations.

Converged in 0.01 seconds


================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.07
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.982 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.57 MW
@ line 5-2
9.61 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
41.04
2 1.150
-2.702
50.00
14.72
3 1.038 -11.441
55.00
13.00
4 0.999
-8.753
5 1.006 -10.954
30.00
18.00
6 0.982 -10.851
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.76
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.09
22.56
-48.10
-13.34
1.996
9.23
2
1
6
43.64
18.48
-41.35
-8.87
2.283
9.61
3
2
3
18.05
1.12
-16.26
1.47
1.789
2.60
4
4
3
38.74
16.58
-38.74
-14.47
0.000
2.11
5
4
6
9.36
2.24
-9.27
-1.87
0.090
0.38
6
5
2
-29.38
-7.76
31.95
13.59
2.570
5.83
7
6
5
0.62
10.55
-0.62
-10.24
0.000
0.31
-------- -------Total:
8.727
30.07

Newton's method power flow converged in 2 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.74
30.07
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.63 MW
@ line 5-2
9.56 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
40.67
2 1.150
-2.699
50.00
15.07
3 1.042 -11.436
55.00
13.00
4 1.000
-8.759
5 1.002 -10.940
30.00
18.00
6 0.983 -10.851
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.74
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.12
22.50
-48.12
-13.27
1.995
9.23
2
1
6
43.62
18.16
-41.35
-8.61
2.270
9.56
3
2
3
17.91
0.84
-16.15
1.71
1.758
2.55
4
4
3
38.85
16.83
-38.85
-14.71
0.000
2.11
5
4
6
9.28
1.94
-9.19
-1.58
0.087
0.37
6
5
2
-29.46
-8.27
32.09
14.23
2.627
5.96
7
6
5
0.54
10.02
-0.54
-9.73
0.000
0.28
-------- -------Total:
8.737
30.07

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.31
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.41 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.46 MW
@ line 5-2
9.83 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.43
2 1.150
-2.553
50.00
12.68
3 1.040 -11.412
55.00
13.00
4 0.996
-8.739
5 1.017 -10.935
30.00
18.00
6 0.975 -10.835
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.11
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
23.63
-48.06
-14.25
2.028
9.38
2
1
6
43.64
19.80
-41.30
-9.97
2.334
9.83
3
2
3
18.17
0.91
-16.36
1.72
1.809
2.63
4
4
3
38.64
16.82
-38.64
-14.72
0.000
2.10
5
4
6
9.41
2.88
-9.32
-2.49
0.095
0.40
6
5
2
-29.38
-6.19
31.83
11.77
2.456
5.57
7
6
5
0.62
12.21
-0.62
-11.81
0.000
0.41
-------- -------Total:
8.722
30.31

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.95
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.58 MW
@ line 5-2
9.55 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
39.83
2 1.150
-2.825
50.00
15.76
3 1.032 -11.474
55.00
13.00
4 1.002
-8.756
5 1.004 -10.993
30.00
18.00
6 0.984 -10.867
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.59
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
21.86
-48.09
-12.73
1.973
9.13
2
1
6
43.67
17.97
-41.40
-8.43
2.267
9.55
3
2
3
18.19
1.74
-16.36
0.91
1.825
2.65
4
4
3
38.64
16.02
-38.64
-13.91
0.000
2.11
5
4
6
9.45
2.23
-9.36
-1.85
0.091
0.38
6
5
2
-29.24
-8.17
31.81
14.02
2.577
5.85
7
6
5
0.76
10.12
-0.76
-9.83
0.000
0.29
-------- -------Total:
8.733
29.95

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.08
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.980 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.51 MW
@ line 5-2
9.68 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.38
2 1.150
-2.717
50.00
14.40
3 1.033 -11.451
55.00
13.00
4 0.999
-8.747
5 1.011 -10.975
30.00
18.00
6 0.980 -10.854
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.79
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
22.57
-48.07
-13.35
1.994
9.22
2
1
6
43.66
18.81
-41.36
-9.13
2.297
9.68
3
2
3
18.23
1.52
-16.40
1.14
1.830
2.66
4
4
3
38.60
16.24
-38.60
-14.14
0.000
2.10
5
4
6
9.47
2.60
-9.38
-2.21
0.094
0.39
6
5
2
-29.26
-7.20
31.77
12.88
2.505
5.69
7
6
5
0.74
11.15
-0.74
-10.80
0.000
0.34
-------- -------Total:
8.721
30.08

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.75
30.35
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.978 p.u. @ bus 6
Voltage Angle
-11.38 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.60 MW
@ line 5-2
9.71 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
43.08
2 1.150
-2.475
50.00
13.04
3 1.054 -11.381
55.00
13.00
4 0.995
-8.754
5 1.008 -10.873
30.00
18.00
6 0.978 -10.824
50.00
5.00
-------- -------- -------- -------Total:
143.75
56.12
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.17
23.87
-48.13
-14.43
2.041
9.44
2
1
6
43.57
19.20
-41.27
-9.50
2.305
9.71
3
2
3
17.70
-0.24
-15.99
2.73
1.713
2.49
4
4
3
39.01
17.85
-39.01
-15.73
0.000
2.12
5
4
6
9.12
2.03
-9.03
-1.67
0.086
0.36
6
5
2
-29.70
-7.38
32.30
13.28
2.601
5.90
7
6
5
0.30
10.95
-0.30
-10.62
0.000
0.33
-------- -------Total:
8.746
30.35

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.24
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.43 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.45 MW
@ line 5-2
9.80 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.85
2 1.150
-2.615
50.00
13.16
3 1.036 -11.429
55.00
13.00
4 0.997
-8.740
5 1.017 -10.956
30.00
18.00
6 0.976 -10.843
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.01
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
23.27
-48.05
-13.95
2.015
9.32
2
1
6
43.66
19.58
-41.33
-9.78
2.327
9.80
3
2
3
18.26
1.26
-16.42
1.40
1.831
2.66
4
4
3
38.58
16.50
-38.58
-14.40
0.000
2.10
5
4
6
9.47
2.92
-9.38
-2.52
0.096
0.40
6
5
2
-29.29
-6.33
31.74
11.89
2.450
5.56
7
6
5
0.71
12.07
-0.71
-11.67
0.000
0.40
-------- -------Total:
8.719
30.24

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.1
Losses (I^2 * Z)
8.75
30.74
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.969 p.u. @ bus 6
Voltage Angle
-11.36 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.40 MW
@ line 5-2
10.07 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
46.40
2 1.150
-2.322
50.00
10.25
3 1.050 -11.358
55.00
13.00
4 0.990
-8.732
5 1.026 -10.880
30.00
18.00
6 0.969 -10.810
50.00
5.00
-------- -------- -------- -------Total:
143.75
56.66
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.14
25.19
-48.06
-15.56
2.082
9.63
2
1
6
43.61
21.21
-41.22
-11.15
2.391
10.07
3
2
3
18.04
-0.03
-16.26
2.62
1.779
2.58
4
4
3
38.74
17.72
-38.74
-15.62
0.000
2.11
5
4
6
9.32
3.23
-9.22
-2.83
0.096
0.40
6
5
2
-29.56
-4.83
31.96
10.29
2.404
5.46
7
6
5
0.44
13.66
-0.44
-13.17
0.000
0.49
-------- -------Total:
8.751
30.74

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.88
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.985 p.u. @ bus 6
Voltage Angle
-11.50 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.55 MW
@ line 5-2
9.53 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.15
2 1.150
-2.918
50.00
16.34
3 1.025 -11.502
55.00
13.00
4 1.003
-8.756
5 1.004 -11.030
30.00
18.00
6 0.985 -10.879
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.49
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
21.39
-48.08
-12.33
1.958
9.05
2
1
6
43.70
17.76
-41.44
-8.23
2.262
9.53
3
2
3
18.35
2.32
-16.48
0.40
1.871
2.72
4
4
3
38.52
15.50
-38.52
-13.40
0.000
2.11
5
4
6
9.56
2.37
-9.47
-1.98
0.093
0.39
6
5
2
-29.09
-8.22
31.65
14.02
2.555
5.80
7
6
5
0.91
10.06
-0.91
-9.78
0.000
0.29
-------- -------Total:
8.739
29.88

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.07
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.56 MW
@ line 5-2
9.63 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
41.10
2 1.150
-2.707
50.00
14.67
3 1.037 -11.444
55.00
13.00
4 0.999
-8.752
5 1.007 -10.959
30.00
18.00
6 0.981 -10.852
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.76
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
22.56
-48.09
-13.33
1.995
9.23
2
1
6
43.64
18.54
-41.36
-8.91
2.286
9.63
3
2
3
18.09
1.22
-16.30
1.39
1.798
2.61
4
4
3
38.70
16.50
-38.70
-14.39
0.000
2.11
5
4
6
9.38
2.32
-9.29
-1.94
0.091
0.38
6
5
2
-29.35
-7.65
31.91
13.45
2.557
5.80
7
6
5
0.65
10.67
-0.65
-10.35
0.000
0.32
-------- -------Total:
8.725
30.07

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.2
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.36
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.973 p.u. @ bus 6
Voltage Angle
-11.42 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.39 MW
@ line 5-2
9.91 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.87
2 1.150
-2.567
50.00
12.31
3 1.035 -11.422
55.00
13.00
4 0.996
-8.733
5 1.022 -10.958
30.00
18.00
6 0.973 -10.839
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.18
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
23.68
-48.03
-14.30
2.027
9.38
2
1
6
43.67
20.19
-41.32
-10.28
2.353
9.91
3
2
3
18.36
1.32
-16.50
1.37
1.851
2.69
4
4
3
38.50
16.47
-38.50
-14.37
0.000
2.10
5
4
6
9.53
3.28
-9.43
-2.87
0.099
0.42
6
5
2
-29.25
-5.56
31.64
10.99
2.393
5.43
7
6
5
0.75
12.89
-0.75
-12.44
0.000
0.45
-------- -------Total:
8.724
30.36

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.91
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.53 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.43 MW
@ line 5-2
9.63 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.65
2 1.150
-2.965
50.00
15.89
3 1.015 -11.528
55.00
13.00
4 1.004
-8.747
5 1.012 -11.075
30.00
18.00
6 0.983 -10.889
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.55
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.98
21.34
-48.03
-12.31
1.953
9.03
2
1
6
43.76
18.32
-41.47
-8.68
2.288
9.63
3
2
3
18.71
3.14
-16.75
-0.28
1.969
2.86
4
4
3
38.25
14.82
-38.25
-12.72
0.000
2.10
5
4
6
9.78
3.03
-9.67
-2.60
0.101
0.42
6
5
2
-28.85
-7.23
31.29
12.76
2.434
5.52
7
6
5
1.15
11.11
-1.15
-10.77
0.000
0.34
-------- -------Total:
8.744
29.91

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.24
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.35 MW
@ line 1-6
9.89 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
42.78
2 1.150
-2.728
50.00
13.23
3 1.022 -11.472
55.00
13.00
4 0.998
-8.731
5 1.024 -11.025
30.00
18.00
6 0.975 -10.862
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.01
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.00
22.86
-48.00
-13.62
1.998
9.24
2
1
6
43.74
19.92
-41.39
-10.03
2.348
9.89
3
2
3
18.70
2.44
-16.75
0.39
1.943
2.82
4
4
3
38.25
15.48
-38.25
-13.39
0.000
2.09
5
4
6
9.75
3.62
-9.65
-3.18
0.105
0.44
6
5
2
-28.97
-5.49
31.30
10.79
2.338
5.31
7
6
5
1.03
12.97
-1.03
-12.51
0.000
0.45
-------- -------Total:
8.733
30.24

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.75
29.86
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.54 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.46 MW
@ line 5-2
9.58 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
39.05
2 1.150
-3.007
50.00
16.42
3 1.014 -11.537
55.00
13.00
4 1.004
-8.751
5 1.010 -11.082
30.00
18.00
6 0.984 -10.893
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.47
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.99
21.06
-48.04
-12.07
1.945
9.00
2
1
6
43.76
17.98
-41.49
-8.40
2.276
9.58
3
2
3
18.69
3.21
-16.72
-0.35
1.966
2.86
4
4
3
38.28
14.75
-38.28
-12.65
0.000
2.10
5
4
6
9.77
2.87
-9.67
-2.45
0.100
0.42
6
5
2
-28.85
-7.63
31.31
13.21
2.463
5.59
7
6
5
1.15
10.69
-1.15
-10.37
0.000
0.32
-------- -------Total:
8.749
29.86

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.96
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.58 MW
@ line 5-2
9.55 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
39.97
2 1.150
-2.809
50.00
15.64
3 1.033 -11.470
55.00
13.00
4 1.001
-8.756
5 1.004 -10.987
30.00
18.00
6 0.984 -10.865
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.61
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.07
21.95
-48.09
-12.81
1.976
9.14
2
1
6
43.66
18.02
-41.40
-8.47
2.268
9.55
3
2
3
18.16
1.64
-16.34
1.00
1.818
2.64
4
4
3
38.66
16.11
-38.66
-14.00
0.000
2.11
5
4
6
9.44
2.22
-9.34
-1.84
0.091
0.38
6
5
2
-29.26
-8.15
31.84
14.00
2.580
5.85
7
6
5
0.74
10.14
-0.74
-9.85
0.000
0.29
-------- -------Total:
8.732
29.96

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.4
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.5
Losses (I^2 * Z)
8.83
29.91
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 5
Voltage Angle
-11.50 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.90 MW
@ line 5-2
9.23 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.83
36.32
2 1.150
-3.013
50.00
19.07
3 1.038 -11.503
55.00
13.00
4 1.006
-8.793
5 0.981 -10.994
30.00
18.00
6 0.995 -10.892
50.00
5.00
-------- -------- -------- -------Total:
143.83
55.39
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.17
20.54
-48.23
-11.55
1.943
8.99
2
1
6
43.66
15.78
-41.47
-6.55
2.191
9.23
3
2
3
17.69
1.31
-15.97
1.19
1.720
2.50
4
4
3
39.03
16.32
-39.03
-14.19
0.000
2.13
5
4
6
9.20
0.81
-9.12
-0.46
0.082
0.34
6
5
2
-29.41
-11.18
32.31
17.76
2.899
6.58
7
6
5
0.59
6.97
-0.59
-6.82
0.000
0.15
-------- -------Total:
8.835
29.91

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.92
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.51 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.60 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.71
2 1.150
-2.915
50.00
15.84
3 1.021 -11.508
55.00
13.00
4 1.003
-8.750
5 1.010 -11.046
30.00
18.00
6 0.983 -10.880
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.55
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.01
21.52
-48.05
-12.45
1.960
9.06
2
1
6
43.73
18.19
-41.45
-8.59
2.280
9.60
3
2
3
18.53
2.65
-16.61
0.13
1.915
2.78
4
4
3
38.39
15.24
-38.39
-13.13
0.000
2.10
5
4
6
9.66
2.75
-9.56
-2.34
0.097
0.41
6
5
2
-28.99
-7.56
31.47
13.20
2.483
5.64
7
6
5
1.01
10.76
-1.01
-10.44
0.000
0.32
-------- -------Total:
8.735
29.92

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.01
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.48 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.46 MW
@ line 5-2
9.67 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.74
2 1.150
-2.822
50.00
14.94
3 1.025 -11.484
55.00
13.00
4 1.001
-8.745
5 1.013 -11.021
30.00
18.00
6 0.981 -10.869
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.69
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.02
22.06
-48.04
-12.92
1.976
9.14
2
1
6
43.71
18.68
-41.41
-9.01
2.297
9.67
3
2
3
18.47
2.28
-16.58
0.47
1.894
2.75
4
4
3
38.42
15.57
-38.42
-13.47
0.000
2.10
5
4
6
9.62
2.87
-9.52
-2.46
0.098
0.41
6
5
2
-29.06
-7.08
31.53
12.66
2.461
5.59
7
6
5
0.94
11.27
-0.94
-10.92
0.000
0.35
-------- -------Total:
8.726
30.01

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.4
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.75
29.83
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.986 p.u. @ bus 6
Voltage Angle
-11.52 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.54 MW
@ line 5-2
9.51 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
38.55
2 1.150
-2.994
50.00
16.87
3 1.020 -11.525
55.00
13.00
4 1.005
-8.757
5 1.004 -11.058
30.00
18.00
6 0.986 -10.890
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.42
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.02
21.00
-48.07
-12.00
1.946
9.00
2
1
6
43.73
17.55
-41.47
-8.05
2.257
9.51
3
2
3
18.48
2.77
-16.57
0.00
1.908
2.77
4
4
3
38.43
15.11
-38.43
-13.00
0.000
2.10
5
4
6
9.64
2.44
-9.54
-2.04
0.095
0.40
6
5
2
-28.98
-8.33
31.52
14.10
2.543
5.77
7
6
5
1.02
9.95
-1.02
-9.67
0.000
0.28
-------- -------Total:
8.749
29.83

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.91
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.986 p.u. @ bus 6
Voltage Angle
-11.48 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.62 MW
@ line 5-2
9.48 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.10
2 1.150
-2.871
50.00
16.41
3 1.032 -11.483
55.00
13.00
4 1.003
-8.762
5 1.000 -10.998
30.00
18.00
6 0.986 -10.872
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.51
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.07
21.55
-48.11
-12.46
1.965
9.09
2
1
6
43.67
17.55
-41.42
-8.07
2.252
9.48
3
2
3
18.13
1.76
-16.32
0.88
1.814
2.63
4
4
3
38.68
15.99
-38.68
-13.88
0.000
2.11
5
4
6
9.43
2.00
-9.34
-1.63
0.090
0.38
6
5
2
-29.25
-8.70
31.87
14.66
2.624
5.95
7
6
5
0.75
9.56
-0.75
-9.30
0.000
0.26
-------- -------Total:
8.744
29.91

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.99
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.985 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.63 MW
@ line 5-2
9.52 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.94
2 1.150
-2.778
50.00
15.69
3 1.037 -11.457
55.00
13.00
4 1.001
-8.760
5 1.001 -10.966
30.00
18.00
6 0.985 -10.860
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.63
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.10
22.06
-48.12
-12.90
1.981
9.16
2
1
6
43.64
17.88
-41.38
-8.36
2.261
9.52
3
2
3
18.01
1.26
-16.23
1.33
1.782
2.59
4
4
3
38.77
16.44
-38.77
-14.33
0.000
2.11
5
4
6
9.34
1.97
-9.26
-1.60
0.088
0.37
6
5
2
-29.36
-8.47
31.99
14.43
2.626
5.96
7
6
5
0.64
9.80
-0.64
-9.53
0.000
0.27
-------- -------Total:
8.738
29.99

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.04
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.982 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.56 MW
@ line 5-2
9.61 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.77
2 1.150
-2.740
50.00
14.95
3 1.035 -11.453
55.00
13.00
4 1.000
-8.753
5 1.007 -10.970
30.00
18.00
6 0.982 -10.856
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.71
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
22.36
-48.09
-13.17
1.989
9.20
2
1
6
43.65
18.40
-41.37
-8.80
2.281
9.61
3
2
3
18.13
1.38
-16.32
1.24
1.807
2.62
4
4
3
38.68
16.35
-38.68
-14.24
0.000
2.11
5
4
6
9.41
2.32
-9.32
-1.94
0.091
0.38
6
5
2
-29.31
-7.76
31.87
13.56
2.558
5.81
7
6
5
0.69
10.56
-0.69
-10.24
0.000
0.31
-------- -------Total:
8.726
30.04

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.88
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.986 p.u. @ bus 6
Voltage Angle
-11.49 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.59 MW
@ line 5-2
9.50 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.04
2 1.150
-2.903
50.00
16.45
3 1.028 -11.495
55.00
13.00
4 1.003
-8.759
5 1.002 -11.017
30.00
18.00
6 0.986 -10.877
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.49
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
21.41
-48.09
-12.35
1.960
9.06
2
1
6
43.69
17.62
-41.43
-8.12
2.256
9.50
3
2
3
18.25
2.09
-16.41
0.59
1.846
2.68
4
4
3
38.59
15.70
-38.59
-13.59
0.000
2.11
5
4
6
9.50
2.19
-9.41
-1.81
0.092
0.38
6
5
2
-29.16
-8.48
31.75
14.36
2.589
5.87
7
6
5
0.84
9.79
-0.84
-9.52
0.000
0.27
-------- -------Total:
8.741
29.88

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.79
30.64
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.34 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.63 MW
@ line 5-2
9.79 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.79
44.80
2 1.150
-2.291
50.00
11.69
3 1.067 -11.335
55.00
13.00
4 0.991
-8.758
5 1.008 -10.808
30.00
18.00
6 0.975 -10.804
50.00
5.00
-------- -------- -------- -------Total:
143.79
56.48
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.26
25.00
-48.18
-15.37
2.083
9.64
2
1
6
43.53
19.79
-41.20
-10.01
2.324
9.79
3
2
3
17.39
-1.41
-15.73
3.83
1.665
2.42
4
4
3
39.27
18.97
-39.27
-16.83
0.000
2.13
5
4
6
8.91
1.80
-8.82
-1.46
0.082
0.34
6
5
2
-29.97
-7.13
32.61
13.10
2.633
5.98
7
6
5
0.03
11.22
-0.03
-10.87
0.000
0.35
-------- -------Total:
8.787
30.64

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.08
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.56 MW
@ line 5-2
9.62 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
41.18
2 1.150
-2.692
50.00
14.60
3 1.039 -11.439
55.00
13.00
4 0.999
-8.753
5 1.007 -10.952
30.00
18.00
6 0.981 -10.850
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.78
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.09
22.63
-48.09
-13.39
1.997
9.24
2
1
6
43.64
18.55
-41.35
-8.93
2.285
9.62
3
2
3
18.06
1.10
-16.27
1.50
1.789
2.60
4
4
3
38.73
16.61
-38.73
-14.50
0.000
2.11
5
4
6
9.36
2.27
-9.27
-1.89
0.090
0.38
6
5
2
-29.38
-7.68
31.94
13.50
2.565
5.82
7
6
5
0.62
10.64
-0.62
-10.32
0.000
0.32
-------- -------Total:
8.726
30.08

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.93
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.50 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.62 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
39.89
2 1.150
-2.900
50.00
15.68
3 1.021 -11.505
55.00
13.00
4 1.003
-8.749
5 1.010 -11.043
30.00
18.00
6 0.983 -10.879
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.57
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.01
21.60
-48.05
-12.53
1.962
9.07
2
1
6
43.72
18.29
-41.44
-8.67
2.283
9.62
3
2
3
18.53
2.61
-16.61
0.17
1.914
2.78
4
4
3
38.39
15.27
-38.39
-13.17
0.000
2.10
5
4
6
9.66
2.78
-9.56
-2.38
0.098
0.41
6
5
2
-29.00
-7.46
31.47
13.08
2.477
5.62
7
6
5
1.00
10.87
-1.00
-10.54
0.000
0.33
-------- -------Total:
8.734
29.93

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.28
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.40 MW
@ line 5-2
9.86 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.25
2 1.150
-2.619
50.00
12.82
3 1.033 -11.435
55.00
13.00
4 0.997
-8.735
5 1.021 -10.972
30.00
18.00
6 0.975 -10.845
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.07
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
23.34
-48.03
-14.02
2.016
9.32
2
1
6
43.68
19.90
-41.33
-10.04
2.342
9.86
3
2
3
18.39
1.54
-16.53
1.16
1.862
2.70
4
4
3
38.47
16.26
-38.47
-14.16
0.000
2.10
5
4
6
9.56
3.22
-9.46
-2.81
0.099
0.42
6
5
2
-29.21
-5.83
31.61
11.28
2.402
5.45
7
6
5
0.79
12.60
-0.79
-12.17
0.000
0.43
-------- -------Total:
8.721
30.28

Newton's method power flow converged in 2 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.21
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.44 MW
@ line 5-2
9.79 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.64
2 1.150
-2.642
50.00
13.34
3 1.034 -11.437
55.00
13.00
4 0.997
-8.739
5 1.017 -10.967
30.00
18.00
6 0.977 -10.847
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.97
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
23.12
-48.04
-13.83
2.010
9.30
2
1
6
43.66
19.51
-41.34
-9.72
2.325
9.79
3
2
3
18.31
1.44
-16.46
1.24
1.843
2.68
4
4
3
38.54
16.34
-38.54
-14.24
0.000
2.10
5
4
6
9.51
2.96
-9.41
-2.56
0.097
0.41
6
5
2
-29.25
-6.35
31.69
11.89
2.444
5.55
7
6
5
0.75
12.05
-0.75
-11.65
0.000
0.40
-------- -------Total:
8.719
30.21

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.94
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.49 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.52 MW
@ line 5-2
9.59 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
39.98
2 1.150
-2.858
50.00
15.61
3 1.026 -11.489
55.00
13.00
4 1.002
-8.751
5 1.008 -11.019
30.00
18.00
6 0.983 -10.872
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.59
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.03
21.77
-48.06
-12.66
1.968
9.10
2
1
6
43.70
18.21
-41.42
-8.61
2.278
9.59
3
2
3
18.38
2.21
-16.51
0.52
1.873
2.72
4
4
3
38.49
15.62
-38.49
-13.52
0.000
2.10
5
4
6
9.57
2.57
-9.48
-2.17
0.095
0.40
6
5
2
-29.10
-7.70
31.62
13.41
2.515
5.71
7
6
5
0.90
10.62
-0.90
-10.30
0.000
0.32
-------- -------Total:
8.730
29.94

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.4
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.1
Losses (I^2 * Z)
8.75
30.58
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.973 p.u. @ bus 6
Voltage Angle
-11.36 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.50 MW
@ line 5-2
9.90 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
45.11
2 1.150
-2.356
50.00
11.33
3 1.054 -11.359
55.00
13.00
4 0.992
-8.743
5 1.017 -10.862
30.00
18.00
6 0.973 -10.812
50.00
5.00
-------- -------- -------- -------Total:
143.75
56.44
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.17
24.77
-48.10
-15.19
2.070
9.57
2
1
6
43.58
20.34
-41.23
-10.44
2.351
9.90
3
2
3
17.81
-0.38
-16.08
2.90
1.735
2.52
4
4
3
38.92
18.01
-38.92
-15.90
0.000
2.11
5
4
6
9.18
2.59
-9.09
-2.22
0.090
0.38
6
5
2
-29.69
-6.03
32.19
11.70
2.501
5.68
7
6
5
0.31
12.39
-0.31
-11.97
0.000
0.42
-------- -------Total:
8.747
30.58

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.1
Losses (I^2 * Z)
8.77
30.68
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.973 p.u. @ bus 6
Voltage Angle
-11.34 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.56 MW
@ line 5-2
9.88 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.77
45.48
2 1.150
-2.277
50.00
11.08
3 1.063 -11.336
55.00
13.00
4 0.990
-8.750
5 1.014 -10.822
30.00
18.00
6 0.973 -10.802
50.00
5.00
-------- -------- -------- -------Total:
143.77
56.56
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.23
25.18
-48.14
-15.53
2.087
9.65
2
1
6
43.54
20.29
-41.20
-10.41
2.346
9.88
3
2
3
17.56
-1.12
-15.87
3.58
1.692
2.46
4
4
3
39.13
18.71
-39.13
-16.58
0.000
2.13
5
4
6
9.01
2.22
-8.92
-1.86
0.085
0.36
6
5
2
-29.88
-6.39
32.44
12.20
2.562
5.81
7
6
5
0.12
12.01
-0.12
-11.61
0.000
0.39
-------- -------Total:
8.773
30.68

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.46
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.972 p.u. @ bus 6
Voltage Angle
-11.41 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.37 MW
@ line 5-2
9.98 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
44.58
2 1.150
-2.520
50.00
11.72
3 1.036 -11.412
55.00
13.00
4 0.994
-8.730
5 1.025 -10.950
30.00
18.00
6 0.972 -10.834
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.30
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
24.01
-48.02
-14.59
2.038
9.43
2
1
6
43.67
20.57
-41.30
-10.60
2.369
9.98
3
2
3
18.36
1.20
-16.51
1.49
1.852
2.69
4
4
3
38.49
16.59
-38.49
-14.49
0.000
2.10
5
4
6
9.54
3.44
-9.43
-3.02
0.101
0.42
6
5
2
-29.27
-5.14
31.64
10.52
2.370
5.38
7
6
5
0.73
13.33
-0.73
-12.86
0.000
0.47
-------- -------Total:
8.729
30.46

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.02
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.58 MW
@ line 5-2
9.58 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.51
2 1.150
-2.752
50.00
15.18
3 1.036 -11.454
55.00
13.00
4 1.000
-8.755
5 1.005 -10.969
30.00
18.00
6 0.983 -10.858
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.68
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
22.27
-48.10
-13.08
1.986
9.19
2
1
6
43.65
18.24
-41.37
-8.66
2.275
9.58
3
2
3
18.10
1.35
-16.30
1.26
1.800
2.61
4
4
3
38.70
16.37
-38.70
-14.26
0.000
2.11
5
4
6
9.39
2.21
-9.30
-1.84
0.090
0.38
6
5
2
-29.33
-7.97
31.90
13.82
2.578
5.85
7
6
5
0.67
10.33
-0.67
-10.03
0.000
0.30
-------- -------Total:
8.729
30.02

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.04
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.980 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.68 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.07
2 1.150
-2.774
50.00
14.66
3 1.028 -11.469
55.00
13.00
4 1.000
-8.745
5 1.012 -11.001
30.00
18.00
6 0.980 -10.862
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.73
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.03
22.30
-48.05
-13.13
1.984
9.18
2
1
6
43.69
18.77
-41.39
-9.09
2.298
9.68
3
2
3
18.37
1.95
-16.51
0.76
1.867
2.71
4
4
3
38.49
15.86
-38.49
-13.76
0.000
2.10
5
4
6
9.56
2.77
-9.46
-2.37
0.096
0.40
6
5
2
-29.15
-7.09
31.63
12.71
2.477
5.62
7
6
5
0.85
11.26
-0.85
-10.91
0.000
0.35
-------- -------Total:
8.722
30.04

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.26
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.42 MW
@ line 5-2
9.84 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.01
2 1.150
-2.630
50.00
13.02
3 1.033 -11.437
55.00
13.00
4 0.997
-8.736
5 1.019 -10.971
30.00
18.00
6 0.976 -10.846
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.03
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
23.25
-48.03
-13.94
2.013
9.31
2
1
6
43.67
19.76
-41.34
-9.92
2.336
9.84
3
2
3
18.37
1.53
-16.51
1.17
1.857
2.70
4
4
3
38.49
16.27
-38.49
-14.17
0.000
2.10
5
4
6
9.54
3.14
-9.45
-2.72
0.098
0.41
6
5
2
-29.22
-6.01
31.63
11.49
2.415
5.48
7
6
5
0.78
12.40
-0.78
-11.99
0.000
0.42
-------- -------Total:
8.720
30.26

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.09
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.978 p.u. @ bus 6
Voltage Angle
-11.49 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.38 MW
@ line 5-2
9.77 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
41.51
2 1.150
-2.813
50.00
14.29
3 1.020 -11.490
55.00
13.00
4 1.000
-8.738
5 1.019 -11.039
30.00
18.00
6 0.978 -10.870
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.80
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.99
22.27
-48.01
-13.11
1.980
9.16
2
1
6
43.74
19.24
-41.42
-9.47
2.321
9.77
3
2
3
18.67
2.62
-16.72
0.20
1.943
2.82
4
4
3
38.28
15.29
-38.28
-13.20
0.000
2.09
5
4
6
9.74
3.32
-9.63
-2.89
0.103
0.43
6
5
2
-28.95
-6.26
31.33
11.67
2.384
5.41
7
6
5
1.05
12.14
-1.05
-11.74
0.000
0.40
-------- -------Total:
8.730
30.09

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.89
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.50 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.53 MW
@ line 5-2
9.56 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.38
2 1.150
-2.914
50.00
16.13
3 1.023 -11.504
55.00
13.00
4 1.003
-8.754
5 1.006 -11.035
30.00
18.00
6 0.984 -10.879
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.51
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.03
21.45
-48.07
-12.39
1.959
9.06
2
1
6
43.71
17.93
-41.44
-8.38
2.269
9.56
3
2
3
18.42
2.43
-16.53
0.31
1.887
2.74
4
4
3
38.47
15.41
-38.47
-13.31
0.000
2.10
5
4
6
9.60
2.51
-9.50
-2.11
0.095
0.40
6
5
2
-29.05
-7.97
31.58
13.70
2.527
5.74
7
6
5
0.95
10.34
-0.95
-10.03
0.000
0.30
-------- -------Total:
8.737
29.89

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.75
29.90
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.987 p.u. @ bus 6
Voltage Angle
-11.48 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.64 MW
@ line 5-2
9.46 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
38.91
2 1.150
-2.879
50.00
16.59
3 1.032 -11.484
55.00
13.00
4 1.003
-8.764
5 0.999 -10.997
30.00
18.00
6 0.987 -10.873
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.50
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
21.48
-48.12
-12.40
1.963
9.08
2
1
6
43.67
17.43
-41.42
-7.96
2.247
9.46
3
2
3
18.10
1.72
-16.29
0.90
1.807
2.62
4
4
3
38.71
16.02
-38.71
-13.90
0.000
2.11
5
4
6
9.41
1.92
-9.32
-1.55
0.089
0.37
6
5
2
-29.26
-8.87
31.90
14.87
2.642
6.00
7
6
5
0.74
9.38
-0.74
-9.13
0.000
0.25
-------- -------Total:
8.748
29.90

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.92
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.51 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.61 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
39.81
2 1.150
-2.905
50.00
15.75
3 1.021 -11.506
55.00
13.00
4 1.003
-8.749
5 1.010 -11.043
30.00
18.00
6 0.983 -10.879
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.56
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.01
21.57
-48.05
-12.50
1.961
9.07
2
1
6
43.72
18.24
-41.44
-8.63
2.282
9.61
3
2
3
18.52
2.60
-16.61
0.18
1.912
2.78
4
4
3
38.39
15.28
-38.39
-13.18
0.000
2.10
5
4
6
9.66
2.76
-9.56
-2.35
0.097
0.41
6
5
2
-29.00
-7.52
31.48
13.15
2.482
5.63
7
6
5
1.00
10.81
-1.00
-10.48
0.000
0.33
-------- -------Total:
8.734
29.92

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.96
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.986 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.65 MW
@ line 5-2
9.49 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.55
2 1.150
-2.803
50.00
16.04
3 1.037 -11.462
55.00
13.00
4 1.002
-8.763
5 1.000 -10.970
30.00
18.00
6 0.986 -10.863
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.59
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.10
21.89
-48.12
-12.75
1.976
9.14
2
1
6
43.64
17.66
-41.39
-8.17
2.253
9.49
3
2
3
17.99
1.29
-16.21
1.29
1.778
2.58
4
4
3
38.79
16.41
-38.79
-14.29
0.000
2.11
5
4
6
9.33
1.86
-9.25
-1.49
0.088
0.37
6
5
2
-29.36
-8.74
32.01
14.75
2.650
6.01
7
6
5
0.64
9.52
-0.64
-9.26
0.000
0.26
-------- -------Total:
8.744
29.96

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.77
29.77
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.987 p.u. @ bus 6
Voltage Angle
-11.56 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.52 MW
@ line 5-2
9.49 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.77
37.73
2 1.150
-3.112
50.00
17.60
3 1.012 -11.562
55.00
13.00
4 1.007
-8.759
5 1.004 -11.105
30.00
18.00
6 0.987 -10.906
50.00
5.00
-------- -------- -------- -------Total:
143.77
55.33
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.99
20.43
-48.06
-11.51
1.928
8.92
2
1
6
43.78
17.30
-41.53
-7.81
2.252
9.49
3
2
3
18.68
3.49
-16.71
-0.62
1.975
2.87
4
4
3
38.29
14.49
-38.29
-12.38
0.000
2.10
5
4
6
9.77
2.60
-9.67
-2.19
0.098
0.41
6
5
2
-28.80
-8.40
31.32
14.11
2.516
5.71
7
6
5
1.20
9.88
-1.20
-9.60
0.000
0.28
-------- -------Total:
8.769
29.77

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.32
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.39 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.55 MW
@ line 5-2
9.74 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
43.16
2 1.150
-2.502
50.00
12.95
3 1.049 -11.391
55.00
13.00
4 0.995
-8.749
5 1.011 -10.894
30.00
18.00
6 0.977 -10.828
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.10
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.14
23.77
-48.11
-14.36
2.036
9.42
2
1
6
43.59
19.38
-41.28
-9.64
2.314
9.74
3
2
3
17.86
0.15
-16.11
2.38
1.743
2.53
4
4
3
38.89
17.49
-38.89
-15.38
0.000
2.11
5
4
6
9.22
2.31
-9.13
-1.94
0.088
0.37
6
5
2
-29.59
-7.00
32.14
12.79
2.552
5.79
7
6
5
0.41
11.35
-0.41
-11.00
0.000
0.36
-------- -------Total:
8.733
30.32

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.95
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.49 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.52 MW
@ line 5-2
9.59 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.01
2 1.150
-2.852
50.00
15.58
3 1.026 -11.487
55.00
13.00
4 1.002
-8.751
5 1.008 -11.016
30.00
18.00
6 0.983 -10.871
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.59
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.03
21.80
-48.06
-12.69
1.969
9.11
2
1
6
43.70
18.21
-41.42
-8.62
2.278
9.59
3
2
3
18.36
2.16
-16.50
0.56
1.869
2.71
4
4
3
38.50
15.66
-38.50
-13.56
0.000
2.10
5
4
6
9.56
2.55
-9.47
-2.15
0.095
0.40
6
5
2
-29.12
-7.71
31.64
13.43
2.518
5.72
7
6
5
0.88
10.60
-0.88
-10.29
0.000
0.31
-------- -------Total:
8.730
29.95

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.0
Losses (I^2 * Z)
8.79
30.97
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.967 p.u. @ bus 6
Voltage Angle
-11.32 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.46 MW
@ line 5-2
10.11 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.79
47.64
2 1.150
-2.168
50.00
9.30
3 1.063 -11.317
55.00
13.00
4 0.987
-8.738
5 1.024 -10.818
30.00
18.00
6 0.967 -10.792
50.00
5.00
-------- -------- -------- -------Total:
143.79
56.94
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.23
26.10
-48.11
-16.30
2.118
9.80
2
1
6
43.56
21.54
-41.16
-11.43
2.401
10.11
3
2
3
17.71
-1.16
-15.99
3.66
1.722
2.50
4
4
3
39.01
18.78
-39.01
-16.66
0.000
2.12
5
4
6
9.09
2.88
-9.00
-2.50
0.091
0.38
6
5
2
-29.83
-4.89
32.29
10.47
2.457
5.58
7
6
5
0.17
13.60
-0.17
-13.11
0.000
0.49
-------- -------Total:
8.788
30.97

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.03
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.67 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
40.98
2 1.150
-2.780
50.00
14.74
3 1.028 -11.470
55.00
13.00
4 1.000
-8.746
5 1.012 -11.001
30.00
18.00
6 0.981 -10.863
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.72
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
22.26
-48.05
-13.09
1.983
9.17
2
1
6
43.69
18.71
-41.39
-9.04
2.296
9.67
3
2
3
18.37
1.96
-16.50
0.75
1.866
2.71
4
4
3
38.50
15.85
-38.50
-13.75
0.000
2.10
5
4
6
9.56
2.75
-9.46
-2.34
0.096
0.40
6
5
2
-29.15
-7.15
31.63
12.78
2.482
5.63
7
6
5
0.85
11.20
-0.85
-10.85
0.000
0.35
-------- -------Total:
8.723
30.03

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
29.98
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.55 MW
@ line 5-2
9.58 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.22
2 1.150
-2.801
50.00
15.41
3 1.032 -11.470
55.00
13.00
4 1.001
-8.754
5 1.006 -10.991
30.00
18.00
6 0.983 -10.864
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.63
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
22.03
-48.08
-12.88
1.978
9.15
2
1
6
43.67
18.20
-41.39
-8.62
2.275
9.58
3
2
3
18.21
1.72
-16.38
0.94
1.830
2.66
4
4
3
38.62
16.04
-38.62
-13.94
0.000
2.11
5
4
6
9.47
2.35
-9.37
-1.97
0.092
0.39
6
5
2
-29.23
-7.89
31.79
13.69
2.554
5.80
7
6
5
0.77
10.41
-0.77
-10.11
0.000
0.30
-------- -------Total:
8.729
29.98

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.75
29.97
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.986 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.66 MW
@ line 5-2
9.48 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
39.57
2 1.150
-2.794
50.00
16.03
3 1.038 -11.459
55.00
13.00
4 1.001
-8.764
5 0.999 -10.965
30.00
18.00
6 0.986 -10.862
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.60
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.11
21.93
-48.13
-12.78
1.978
9.15
2
1
6
43.64
17.64
-41.39
-8.16
2.252
9.48
3
2
3
17.95
1.19
-16.18
1.38
1.770
2.57
4
4
3
38.82
16.49
-38.82
-14.38
0.000
2.11
5
4
6
9.31
1.81
-9.22
-1.44
0.087
0.37
6
5
2
-29.39
-8.80
32.05
14.83
2.659
6.04
7
6
5
0.61
9.46
-0.61
-9.20
0.000
0.26
-------- -------Total:
8.746
29.97

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.74
30.21
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.980 p.u. @ bus 6
Voltage Angle
-11.41 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.60 MW
@ line 5-2
9.65 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
42.05
2 1.150
-2.574
50.00
13.89
3 1.048 -11.406
55.00
13.00
4 0.997
-8.755
5 1.006 -10.905
30.00
18.00
6 0.980 -10.836
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.94
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.14
23.27
-48.12
-13.92
2.020
9.34
2
1
6
43.59
18.78
-41.30
-9.14
2.291
9.65
3
2
3
17.81
0.28
-16.08
2.24
1.735
2.52
4
4
3
38.92
17.36
-38.92
-15.24
0.000
2.12
5
4
6
9.20
2.03
-9.11
-1.67
0.087
0.36
6
5
2
-29.58
-7.70
32.19
13.61
2.604
5.91
7
6
5
0.42
10.61
-0.42
-10.30
0.000
0.31
-------- -------Total:
8.737
30.21

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.02
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.57 MW
@ line 5-2
9.59 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.54
2 1.150
-2.753
50.00
15.15
3 1.035 -11.455
55.00
13.00
4 1.000
-8.754
5 1.006 -10.971
30.00
18.00
6 0.983 -10.858
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.69
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
22.27
-48.09
-13.08
1.986
9.18
2
1
6
43.65
18.27
-41.37
-8.68
2.276
9.59
3
2
3
18.11
1.39
-16.31
1.23
1.804
2.62
4
4
3
38.69
16.34
-38.69
-14.23
0.000
2.11
5
4
6
9.40
2.25
-9.31
-1.87
0.091
0.38
6
5
2
-29.32
-7.92
31.89
13.76
2.572
5.84
7
6
5
0.68
10.38
-0.68
-10.08
0.000
0.30
-------- -------Total:
8.729
30.02

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.10
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.980 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.50 MW
@ line 5-2
9.69 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.55
2 1.150
-2.704
50.00
14.26
3 1.034 -11.448
55.00
13.00
4 0.999
-8.746
5 1.012 -10.972
30.00
18.00
6 0.980 -10.853
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.81
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
22.66
-48.06
-13.43
1.996
9.23
2
1
6
43.66
18.90
-41.36
-9.21
2.301
9.69
3
2
3
18.23
1.48
-16.40
1.17
1.830
2.66
4
4
3
38.60
16.28
-38.60
-14.17
0.000
2.10
5
4
6
9.47
2.64
-9.37
-2.24
0.094
0.39
6
5
2
-29.27
-7.10
31.77
12.77
2.500
5.67
7
6
5
0.73
11.25
-0.73
-10.90
0.000
0.35
-------- -------Total:
8.720
30.10

Newton's method power flow converged in 2 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.18
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.45 MW
@ line 5-2
9.77 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.33
2 1.150
-2.669
50.00
13.59
3 1.033 -11.443
55.00
13.00
4 0.998
-8.740
5 1.016 -10.974
30.00
18.00
6 0.977 -10.850
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.92
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
22.96
-48.04
-13.69
2.005
9.27
2
1
6
43.67
19.37
-41.35
-9.60
2.320
9.77
3
2
3
18.32
1.55
-16.48
1.13
1.849
2.68
4
4
3
38.52
16.23
-38.52
-14.13
0.000
2.10
5
4
6
9.52
2.93
-9.42
-2.53
0.097
0.41
6
5
2
-29.23
-6.48
31.68
12.04
2.449
5.56
7
6
5
0.77
11.90
-0.77
-11.52
0.000
0.39
-------- -------Total:
8.719
30.18

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.76
30.47
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.36 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.60 MW
@ line 5-2
9.76 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.76
43.91
2 1.150
-2.397
50.00
12.36
3 1.058 -11.362
55.00
13.00
4 0.993
-8.754
5 1.009 -10.850
30.00
18.00
6 0.977 -10.815
50.00
5.00
-------- -------- -------- -------Total:
143.76
56.27
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.20
24.36
-48.14
-14.84
2.058
9.52
2
1
6
43.56
19.55
-41.24
-9.79
2.317
9.76
3
2
3
17.61
-0.64
-15.92
3.11
1.698
2.47
4
4
3
39.08
18.23
-39.08
-16.11
0.000
2.12
5
4
6
9.06
2.03
-8.97
-1.68
0.085
0.36
6
5
2
-29.79
-7.11
32.39
13.01
2.597
5.89
7
6
5
0.21
11.24
-0.21
-10.89
0.000
0.35
-------- -------Total:
8.756
30.47

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.74
30.09
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.43 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.63 MW
@ line 5-2
9.57 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
40.89
2 1.150
-2.676
50.00
14.89
3 1.043 -11.430
55.00
13.00
4 0.999
-8.759
5 1.003 -10.932
30.00
18.00
6 0.983 -10.848
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.77
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.12
22.64
-48.12
-13.39
2.000
9.25
2
1
6
43.61
18.25
-41.34
-8.68
2.272
9.57
3
2
3
17.88
0.71
-16.13
1.83
1.751
2.54
4
4
3
38.87
16.94
-38.87
-14.83
0.000
2.12
5
4
6
9.25
1.93
-9.17
-1.57
0.087
0.36
6
5
2
-29.49
-8.21
32.12
14.17
2.628
5.96
7
6
5
0.51
10.08
-0.51
-9.79
0.000
0.29
-------- -------Total:
8.738
30.09

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.75
29.92
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.987 p.u. @ bus 6
Voltage Angle
-11.48 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.66 MW
@ line 5-2
9.46 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
38.98
2 1.150
-2.861
50.00
16.54
3 1.034 -11.477
55.00
13.00
4 1.003
-8.765
5 0.998 -10.988
30.00
18.00
6 0.987 -10.871
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.52
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.09
21.56
-48.12
-12.47
1.966
9.09
2
1
6
43.66
17.41
-41.41
-7.96
2.246
9.46
3
2
3
18.04
1.56
-16.25
1.05
1.792
2.60
4
4
3
38.75
16.16
-38.75
-14.05
0.000
2.11
5
4
6
9.37
1.84
-9.28
-1.47
0.088
0.37
6
5
2
-29.30
-8.95
31.96
14.98
2.657
6.03
7
6
5
0.70
9.29
-0.70
-9.05
0.000
0.25
-------- -------Total:
8.749
29.92

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.28
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.40 MW
@ line 5-2
9.87 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.25
2 1.150
-2.624
50.00
12.82
3 1.032 -11.437
55.00
13.00
4 0.997
-8.734
5 1.021 -10.975
30.00
18.00
6 0.975 -10.846
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.07
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
23.33
-48.03
-14.01
2.015
9.32
2
1
6
43.68
19.92
-41.34
-10.06
2.343
9.87
3
2
3
18.41
1.60
-16.55
1.12
1.867
2.71
4
4
3
38.45
16.21
-38.45
-14.12
0.000
2.10
5
4
6
9.57
3.26
-9.47
-2.84
0.100
0.42
6
5
2
-29.19
-5.79
31.59
11.22
2.396
5.44
7
6
5
0.81
12.64
-0.81
-12.21
0.000
0.43
-------- -------Total:
8.722
30.28

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.74
29.96
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.52 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.40 MW
@ line 5-2
9.69 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
40.20
2 1.150
-2.934
50.00
15.42
3 1.015 -11.523
55.00
13.00
4 1.003
-8.743
5 1.015 -11.073
30.00
18.00
6 0.981 -10.886
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.62
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.98
21.57
-48.02
-12.51
1.959
9.06
2
1
6
43.76
18.63
-41.46
-8.95
2.300
9.69
3
2
3
18.76
3.13
-16.78
-0.26
1.977
2.87
4
4
3
38.22
14.84
-38.22
-12.74
0.000
2.10
5
4
6
9.80
3.20
-9.70
-2.77
0.103
0.43
6
5
2
-28.84
-6.84
31.24
12.29
2.404
5.46
7
6
5
1.16
11.53
-1.16
-11.16
0.000
0.37
-------- -------Total:
8.742
29.96

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.19
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.40 MW
@ line 5-2
9.82 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.49
2 1.150
-2.701
50.00
13.46
3 1.027 -11.458
55.00
13.00
4 0.998
-8.736
5 1.020 -10.999
30.00
18.00
6 0.976 -10.856
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.95
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.02
22.88
-48.02
-13.63
2.000
9.25
2
1
6
43.70
19.61
-41.37
-9.79
2.332
9.82
3
2
3
18.50
1.99
-16.61
0.76
1.893
2.75
4
4
3
38.39
15.85
-38.39
-13.76
0.000
2.10
5
4
6
9.63
3.25
-9.53
-2.83
0.101
0.42
6
5
2
-29.10
-6.03
31.50
11.47
2.396
5.44
7
6
5
0.90
12.38
-0.90
-11.97
0.000
0.42
-------- -------Total:
8.722
30.19

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.79
30.29
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.974 p.u. @ bus 6
Voltage Angle
-11.54 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.37 MW
@ line 1-6
9.97 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.79
42.42
2 1.150
-2.896
50.00
13.63
3 1.005 -11.538
55.00
13.00
4 1.000
-8.727
5 1.031 -11.117
30.00
18.00
6 0.974 -10.891
50.00
5.00
-------- -------- -------- -------Total:
143.79
56.05
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.94
22.25
-47.96
-13.11
1.976
9.14
2
1
6
43.85
20.17
-41.48
-10.20
2.368
9.97
3
2
3
19.23
3.91
-17.12
-0.85
2.104
3.06
4
4
3
37.88
14.23
-37.88
-12.15
0.000
2.08
5
4
6
10.08
4.38
-9.97
-3.89
0.117
0.49
6
5
2
-28.55
-4.68
30.77
9.72
2.221
5.04
7
6
5
1.45
13.83
-1.45
-13.32
0.000
0.51
-------- -------Total:
8.786
30.29

Newton's method power flow converged in 4 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.2
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.74
30.42
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.38 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.55 MW
@ line 5-2
9.79 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
43.88
2 1.150
-2.437
50.00
12.35
3 1.053 -11.375
55.00
13.00
4 0.994
-8.748
5 1.012 -10.875
30.00
18.00
6 0.976 -10.820
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.23
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.16
24.18
-48.11
-14.70
2.050
9.48
2
1
6
43.58
19.70
-41.25
-9.90
2.325
9.79
3
2
3
17.79
-0.17
-16.06
2.69
1.731
2.51
4
4
3
38.94
17.80
-38.94
-15.69
0.000
2.12
5
4
6
9.17
2.33
-9.08
-1.96
0.088
0.37
6
5
2
-29.66
-6.74
32.21
12.52
2.546
5.78
7
6
5
0.34
11.63
-0.34
-11.26
0.000
0.37
-------- -------Total:
8.740
30.42

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.73
29.91
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.50 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.54 MW
@ line 5-2
9.55 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
39.49
2 1.150
-2.891
50.00
16.04
3 1.026 -11.496
55.00
13.00
4 1.003
-8.754
5 1.006 -11.024
30.00
18.00
6 0.984 -10.876
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.53
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.03
21.55
-48.07
-12.48
1.962
9.08
2
1
6
43.70
17.94
-41.43
-8.39
2.268
9.55
3
2
3
18.36
2.25
-16.49
0.46
1.870
2.72
4
4
3
38.51
15.57
-38.51
-13.46
0.000
2.10
5
4
6
9.56
2.44
-9.47
-2.05
0.094
0.39
6
5
2
-29.10
-8.02
31.64
13.78
2.540
5.76
7
6
5
0.90
10.28
-0.90
-9.98
0.000
0.30
-------- -------Total:
8.735
29.91

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.25
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.39 MW
@ line 5-2
9.86 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.95
2 1.150
-2.663
50.00
13.07
3 1.029 -11.449
55.00
13.00
4 0.997
-8.734
5 1.021 -10.990
30.00
18.00
6 0.975 -10.851
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.02
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.03
23.12
-48.02
-13.83
2.008
9.29
2
1
6
43.69
19.83
-41.35
-9.97
2.340
9.86
3
2
3
18.48
1.85
-16.60
0.89
1.887
2.74
4
4
3
38.40
15.99
-38.40
-13.89
0.000
2.09
5
4
6
9.62
3.31
-9.52
-2.89
0.101
0.42
6
5
2
-29.13
-5.81
31.52
11.23
2.387
5.42
7
6
5
0.87
12.62
-0.87
-12.19
0.000
0.43
-------- -------Total:
8.723
30.25

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.27
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.43 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.42 MW
@ line 5-2
9.84 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.15
2 1.150
-2.610
50.00
12.90
3 1.034 -11.431
55.00
13.00
4 0.997
-8.737
5 1.019 -10.963
30.00
18.00
6 0.975 -10.843
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.05
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
23.36
-48.04
-14.03
2.017
9.33
2
1
6
43.67
19.80
-41.33
-9.96
2.337
9.84
3
2
3
18.33
1.39
-16.48
1.29
1.847
2.68
4
4
3
38.52
16.39
-38.52
-14.29
0.000
2.10
5
4
6
9.52
3.10
-9.42
-2.68
0.098
0.41
6
5
2
-29.25
-6.02
31.67
11.51
2.422
5.50
7
6
5
0.75
12.40
-0.75
-11.98
0.000
0.42
-------- -------Total:
8.720
30.27

Newton's method power flow converged in 3 iterations.


Converged in 0.05 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.74
30.11
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.51 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.34 MW
@ line 5-2
9.81 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
41.57
2 1.150
-2.847
50.00
14.26
3 1.016 -11.506
55.00
13.00
4 1.001
-8.735
5 1.021 -11.062
30.00
18.00
6 0.977 -10.877
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.83
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.97
22.18
-48.00
-13.04
1.976
9.14
2
1
6
43.77
19.40
-41.44
-9.58
2.330
9.81
3
2
3
18.82
3.01
-16.83
-0.12
1.986
2.88
4
4
3
38.17
14.97
-38.17
-12.88
0.000
2.09
5
4
6
9.83
3.57
-9.73
-3.13
0.106
0.44
6
5
2
-28.84
-5.93
31.18
11.25
2.343
5.32
7
6
5
1.16
12.49
-1.16
-12.07
0.000
0.42
-------- -------Total:
8.740
30.11

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.74
30.45
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.38 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.52 MW
@ line 5-2
9.83 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
44.20
2 1.150
-2.429
50.00
12.07
3 1.051 -11.375
55.00
13.00
4 0.993
-8.745
5 1.015 -10.880
30.00
18.00
6 0.975 -10.820
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.27
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.15
24.28
-48.10
-14.79
2.053
9.49
2
1
6
43.59
19.92
-41.25
-10.09
2.335
9.83
3
2
3
17.86
-0.07
-16.11
2.60
1.743
2.53
4
4
3
38.89
17.71
-38.89
-15.60
0.000
2.11
5
4
6
9.21
2.50
-9.12
-2.13
0.090
0.38
6
5
2
-29.63
-6.42
32.14
12.14
2.517
5.71
7
6
5
0.37
11.97
-0.37
-11.58
0.000
0.39
-------- -------Total:
8.737
30.45

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.75
29.95
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.987 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.69 MW
@ line 5-2
9.45 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
39.14
2 1.150
-2.822
50.00
16.42
3 1.038 -11.465
55.00
13.00
4 1.002
-8.767
5 0.997 -10.968
30.00
18.00
6 0.987 -10.866
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.56
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.11
21.74
-48.14
-12.62
1.973
9.12
2
1
6
43.64
17.40
-41.40
-7.95
2.244
9.45
3
2
3
17.92
1.22
-16.16
1.34
1.764
2.56
4
4
3
38.84
16.46
-38.84
-14.34
0.000
2.12
5
4
6
9.30
1.68
-9.21
-1.32
0.086
0.36
6
5
2
-29.39
-9.10
32.08
15.20
2.687
6.10
7
6
5
0.61
9.14
-0.61
-8.90
0.000
0.24
-------- -------Total:
8.754
29.95

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.4
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.1
Losses (I^2 * Z)
8.74
30.50
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.971 p.u. @ bus 6
Voltage Angle
-11.42 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.38 MW
@ line 1-6
10.02 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
44.81
2 1.150
-2.536
50.00
11.54
3 1.033 -11.421
55.00
13.00
4 0.994
-8.727
5 1.028 -10.967
30.00
18.00
6 0.971 -10.838
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.35
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
24.01
-48.01
-14.59
2.037
9.42
2
1
6
43.69
20.80
-41.31
-10.77
2.380
10.02
3
2
3
18.49
1.48
-16.61
1.25
1.881
2.73
4
4
3
38.39
16.34
-38.39
-14.25
0.000
2.09
5
4
6
9.61
3.69
-9.51
-3.25
0.104
0.44
6
5
2
-29.18
-4.76
31.51
10.06
2.333
5.29
7
6
5
0.82
13.74
-0.82
-13.24
0.000
0.50
-------- -------Total:
8.735
30.50

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.01
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.49 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.46 MW
@ line 5-2
9.68 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.77
2 1.150
-2.824
50.00
14.92
3 1.024 -11.486
55.00
13.00
4 1.001
-8.745
5 1.013 -11.023
30.00
18.00
6 0.981 -10.869
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.69
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.02
22.06
-48.04
-12.92
1.976
9.14
2
1
6
43.71
18.71
-41.41
-9.03
2.298
9.68
3
2
3
18.49
2.32
-16.59
0.44
1.899
2.76
4
4
3
38.41
15.53
-38.41
-13.44
0.000
2.10
5
4
6
9.63
2.90
-9.54
-2.49
0.098
0.41
6
5
2
-29.05
-7.03
31.51
12.60
2.455
5.57
7
6
5
0.95
11.33
-0.95
-10.97
0.000
0.35
-------- -------Total:
8.726
30.01

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.74
29.89
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.52 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.58 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
39.37
2 1.150
-2.952
50.00
16.14
3 1.019 -11.519
55.00
13.00
4 1.004
-8.751
5 1.009 -11.058
30.00
18.00
6 0.984 -10.885
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.51
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.00
21.32
-48.05
-12.28
1.953
9.03
2
1
6
43.74
18.05
-41.46
-8.47
2.276
9.58
3
2
3
18.57
2.83
-16.64
-0.03
1.929
2.80
4
4
3
38.36
15.07
-38.36
-12.97
0.000
2.10
5
4
6
9.69
2.75
-9.59
-2.34
0.098
0.41
6
5
2
-28.95
-7.68
31.43
13.31
2.484
5.64
7
6
5
1.05
10.64
-1.05
-10.32
0.000
0.32
-------- -------Total:
8.740
29.89

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.2
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.36
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.39 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.51 MW
@ line 5-2
9.80 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
43.63
2 1.150
-2.492
50.00
12.53
3 1.047 -11.392
55.00
13.00
4 0.995
-8.744
5 1.014 -10.903
30.00
18.00
6 0.976 -10.827
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.16
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.12
23.91
-48.08
-14.48
2.039
9.43
2
1
6
43.61
19.72
-41.28
-9.92
2.328
9.80
3
2
3
17.96
0.33
-16.20
2.23
1.765
2.56
4
4
3
38.80
17.34
-38.80
-15.23
0.000
2.11
5
4
6
9.28
2.58
-9.19
-2.20
0.091
0.38
6
5
2
-29.53
-6.51
32.04
12.20
2.506
5.69
7
6
5
0.47
11.87
-0.47
-11.49
0.000
0.39
-------- -------Total:
8.729
30.36

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.08
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.54 MW
@ line 5-2
9.64 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.23
2 1.150
-2.706
50.00
14.55
3 1.036 -11.445
55.00
13.00
4 0.999
-8.750
5 1.009 -10.963
30.00
18.00
6 0.981 -10.852
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.78
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
22.59
-48.08
-13.36
1.995
9.23
2
1
6
43.65
18.64
-41.36
-9.00
2.290
9.64
3
2
3
18.13
1.29
-16.33
1.33
1.807
2.62
4
4
3
38.67
16.44
-38.67
-14.33
0.000
2.11
5
4
6
9.41
2.41
-9.32
-2.03
0.092
0.38
6
5
2
-29.33
-7.49
31.87
13.26
2.540
5.76
7
6
5
0.67
10.84
-0.67
-10.51
0.000
0.33
-------- -------Total:
8.723
30.08

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.29
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.41 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.49 MW
@ line 5-2
9.79 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
43.17
2 1.150
-2.553
50.00
12.90
3 1.042 -11.409
55.00
13.00
4 0.996
-8.742
5 1.015 -10.927
30.00
18.00
6 0.976 -10.835
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.07
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.10
23.57
-48.07
-14.20
2.027
9.37
2
1
6
43.63
19.60
-41.30
-9.81
2.325
9.79
3
2
3
18.09
0.76
-16.30
1.84
1.792
2.60
4
4
3
38.70
16.95
-38.70
-14.84
0.000
2.11
5
4
6
9.37
2.70
-9.27
-2.31
0.093
0.39
6
5
2
-29.43
-6.50
31.91
12.14
2.486
5.64
7
6
5
0.57
11.89
-0.57
-11.50
0.000
0.39
-------- -------Total:
8.722
30.29

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.19
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.45 MW
@ line 5-2
9.78 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.45
2 1.150
-2.655
50.00
13.49
3 1.034 -11.440
55.00
13.00
4 0.998
-8.740
5 1.016 -10.970
30.00
18.00
6 0.977 -10.848
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.94
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
23.03
-48.05
-13.75
2.007
9.28
2
1
6
43.67
19.42
-41.34
-9.64
2.322
9.78
3
2
3
18.31
1.48
-16.46
1.20
1.844
2.68
4
4
3
38.54
16.30
-38.54
-14.20
0.000
2.10
5
4
6
9.51
2.93
-9.41
-2.52
0.096
0.40
6
5
2
-29.24
-6.45
31.69
12.01
2.449
5.56
7
6
5
0.76
11.94
-0.76
-11.55
0.000
0.39
-------- -------Total:
8.719
30.19

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.48
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.971 p.u. @ bus 6
Voltage Angle
-11.41 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.37 MW
@ line 1-6
9.99 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
44.72
2 1.150
-2.509
50.00
11.61
3 1.037 -11.410
55.00
13.00
4 0.994
-8.730
5 1.025 -10.948
30.00
18.00
6 0.971 -10.833
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.33
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
24.09
-48.02
-14.65
2.041
9.44
2
1
6
43.67
20.63
-41.30
-10.65
2.371
9.99
3
2
3
18.36
1.15
-16.51
1.53
1.850
2.69
4
4
3
38.49
16.63
-38.49
-14.53
0.000
2.10
5
4
6
9.53
3.45
-9.43
-3.03
0.101
0.42
6
5
2
-29.27
-5.08
31.64
10.46
2.368
5.37
7
6
5
0.73
13.40
-0.73
-12.92
0.000
0.48
-------- -------Total:
8.730
30.48

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.4
Losses (I^2 * Z)
8.79
29.94
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.982 p.u. @ bus 6
Voltage Angle
-11.59 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.32 MW
@ line 5-2
9.70 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.79
39.28
2 1.150
-3.121
50.00
16.28
3 0.999 -11.590
55.00
13.00
4 1.005
-8.743
5 1.019 -11.159
30.00
18.00
6 0.982 -10.915
50.00
5.00
-------- -------- -------- -------Total:
143.79
55.56
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.93
20.78
-48.00
-11.83
1.934
8.94
2
1
6
43.86
18.50
-41.56
-8.80
2.304
9.70
3
2
3
19.20
4.47
-17.07
-1.38
2.124
3.08
4
4
3
37.93
13.71
-37.93
-11.62
0.000
2.10
5
4
6
10.07
3.68
-9.96
-3.22
0.110
0.46
6
5
2
-28.48
-6.55
30.80
11.81
2.321
5.27
7
6
5
1.52
11.84
-1.52
-11.45
0.000
0.39
-------- -------Total:
8.793
29.94

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.29
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.974 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.35 MW
@ line 1-6
9.91 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
43.26
2 1.150
-2.673
50.00
12.82
3 1.026 -11.456
55.00
13.00
4 0.997
-8.731
5 1.024 -11.006
30.00
18.00
6 0.974 -10.854
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.08
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.01
23.16
-48.00
-13.87
2.008
9.29
2
1
6
43.72
20.10
-41.36
-10.19
2.353
9.91
3
2
3
18.61
2.12
-16.69
0.67
1.918
2.79
4
4
3
38.31
15.76
-38.31
-13.67
0.000
2.09
5
4
6
9.70
3.58
-9.59
-3.15
0.104
0.44
6
5
2
-29.04
-5.38
31.39
10.71
2.345
5.32
7
6
5
0.96
13.07
-0.96
-12.62
0.000
0.46
-------- -------Total:
8.729
30.29

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
56.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.1
Losses (I^2 * Z)
8.78
30.68
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.974 p.u. @ bus 6
Voltage Angle
-11.33 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.60 MW
@ line 5-2
9.83 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.78
45.21
2 1.150
-2.271
50.00
11.33
3 1.066 -11.332
55.00
13.00
4 0.990
-8.755
5 1.011 -10.809
30.00
18.00
6 0.974 -10.802
50.00
5.00
-------- -------- -------- -------Total:
143.78
56.54
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.25
25.16
-48.17
-15.50
2.088
9.66
2
1
6
43.53
20.05
-41.20
-10.22
2.335
9.83
3
2
3
17.44
-1.38
-15.77
3.81
1.673
2.43
4
4
3
39.23
18.94
-39.23
-16.81
0.000
2.13
5
4
6
8.93
1.96
-8.85
-1.61
0.083
0.35
6
5
2
-29.95
-6.80
32.56
12.71
2.605
5.91
7
6
5
0.05
11.57
-0.05
-11.20
0.000
0.37
-------- -------Total:
8.784
30.68

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.13
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.978 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.42 MW
@ line 5-2
9.77 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.93
2 1.150
-2.739
50.00
13.93
3 1.027 -11.466
55.00
13.00
4 0.999
-8.739
5 1.017 -11.006
30.00
18.00
6 0.978 -10.860
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.86
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.02
22.62
-48.03
-13.40
1.992
9.22
2
1
6
43.70
19.31
-41.38
-9.54
2.320
9.77
3
2
3
18.49
2.08
-16.60
0.67
1.894
2.75
4
4
3
38.40
15.76
-38.40
-13.67
0.000
2.10
5
4
6
9.63
3.13
-9.53
-2.71
0.100
0.42
6
5
2
-29.09
-6.36
31.51
11.85
2.416
5.48
7
6
5
0.91
12.03
-0.91
-11.64
0.000
0.39
-------- -------Total:
8.722
30.13

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.8
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.08
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.980 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.70 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.44
2 1.150
-2.733
50.00
14.35
3 1.031 -11.458
55.00
13.00
4 0.999
-8.745
5 1.013 -10.987
30.00
18.00
6 0.980 -10.857
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.79
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
22.53
-48.05
-13.32
1.992
9.21
2
1
6
43.67
18.91
-41.37
-9.21
2.302
9.70
3
2
3
18.32
1.73
-16.47
0.96
1.851
2.69
4
4
3
38.53
16.06
-38.53
-13.96
0.000
2.10
5
4
6
9.52
2.75
-9.43
-2.35
0.095
0.40
6
5
2
-29.20
-6.99
31.68
12.62
2.480
5.63
7
6
5
0.80
11.36
-0.80
-11.01
0.000
0.36
-------- -------Total:
8.720
30.08

Newton's method power flow converged in 2 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.05
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.980 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.48 MW
@ line 5-2
9.68 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
41.14
2 1.150
-2.763
50.00
14.61
3 1.029 -11.466
55.00
13.00
4 1.000
-8.746
5 1.012 -10.996
30.00
18.00
6 0.980 -10.861
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.74
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
22.36
-48.05
-13.17
1.986
9.18
2
1
6
43.68
18.78
-41.38
-9.10
2.298
9.68
3
2
3
18.35
1.88
-16.49
0.82
1.860
2.70
4
4
3
38.51
15.93
-38.51
-13.82
0.000
2.10
5
4
6
9.54
2.75
-9.45
-2.34
0.096
0.40
6
5
2
-29.17
-7.10
31.65
12.73
2.481
5.63
7
6
5
0.83
11.25
-0.83
-10.90
0.000
0.35
-------- -------Total:
8.722
30.05

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.5
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.1
Losses (I^2 * Z)
8.74
30.59
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.970 p.u. @ bus 6
Voltage Angle
-11.39 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.38 MW
@ line 1-6
10.04 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
45.47
2 1.150
-2.445
50.00
11.00
3 1.040 -11.394
55.00
13.00
4 0.993
-8.728
5 1.027 -10.930
30.00
18.00
6 0.970 -10.826
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.47
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.08
24.50
-48.03
-14.99
2.055
9.50
2
1
6
43.66
20.97
-41.27
-10.93
2.384
10.04
3
2
3
18.30
0.85
-16.46
1.81
1.835
2.66
4
4
3
38.54
16.91
-38.54
-14.81
0.000
2.10
5
4
6
9.49
3.50
-9.39
-3.08
0.101
0.42
6
5
2
-29.34
-4.79
31.70
10.15
2.363
5.36
7
6
5
0.66
13.71
-0.66
-13.21
0.000
0.50
-------- -------Total:
8.737
30.59

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.78
30.20
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.975 p.u. @ bus 6
Voltage Angle
-11.54 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.35 MW
@ line 1-6
9.91 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.78
41.86
2 1.150
-2.917
50.00
14.08
3 1.006 -11.539
55.00
13.00
4 1.001
-8.730
5 1.028 -11.113
30.00
18.00
6 0.975 -10.892
50.00
5.00
-------- -------- -------- -------Total:
143.78
55.94
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.94
22.04
-47.97
-12.93
1.970
9.11
2
1
6
43.84
19.82
-41.48
-9.91
2.353
9.91
3
2
3
19.16
3.84
-17.07
-0.80
2.087
3.03
4
4
3
37.93
14.28
-37.93
-12.20
0.000
2.09
5
4
6
10.04
4.16
-9.93
-3.68
0.114
0.48
6
5
2
-28.59
-5.13
30.84
10.24
2.252
5.11
7
6
5
1.41
13.34
-1.41
-12.87
0.000
0.48
-------- -------Total:
8.776
30.20

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.23
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.979 p.u. @ bus 6
Voltage Angle
-11.41 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.55 MW
@ line 5-2
9.71 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
42.43
2 1.150
-2.578
50.00
13.54
3 1.044 -11.411
55.00
13.00
4 0.997
-8.749
5 1.010 -10.919
30.00
18.00
6 0.979 -10.837
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.97
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.12
23.33
-48.09
-13.98
2.020
9.34
2
1
6
43.61
19.11
-41.31
-9.40
2.305
9.71
3
2
3
17.96
0.58
-16.20
1.98
1.765
2.56
4
4
3
38.80
17.09
-38.80
-14.98
0.000
2.11
5
4
6
9.29
2.35
-9.20
-1.97
0.090
0.38
6
5
2
-29.49
-7.18
32.04
12.96
2.547
5.78
7
6
5
0.51
11.17
-0.51
-10.82
0.000
0.35
-------- -------Total:
8.727
30.23

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.74
30.02
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.984 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.63 MW
@ line 5-2
9.53 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
40.19
2 1.150
-2.746
50.00
15.48
3 1.039 -11.448
55.00
13.00
4 1.000
-8.761
5 1.001 -10.955
30.00
18.00
6 0.984 -10.856
50.00
5.00
-------- -------- -------- -------Total:
143.74
55.67
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.11
22.23
-48.12
-13.04
1.987
9.19
2
1
6
43.63
17.96
-41.37
-8.43
2.263
9.53
3
2
3
17.96
1.06
-16.19
1.50
1.769
2.57
4
4
3
38.81
16.62
-38.81
-14.50
0.000
2.11
5
4
6
9.31
1.93
-9.22
-1.56
0.088
0.37
6
5
2
-29.41
-8.44
32.04
14.41
2.632
5.97
7
6
5
0.59
9.84
-0.59
-9.56
0.000
0.27
-------- -------Total:
8.739
30.02

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.22
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.43 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.47 MW
@ line 5-2
9.77 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.61
2 1.150
-2.618
50.00
13.36
3 1.037 -11.428
55.00
13.00
4 0.997
-8.742
5 1.015 -10.951
30.00
18.00
6 0.977 -10.843
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.97
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.07
23.21
-48.06
-13.89
2.014
9.31
2
1
6
43.65
19.41
-41.33
-9.64
2.319
9.77
3
2
3
18.20
1.16
-16.38
1.48
1.818
2.64
4
4
3
38.62
16.58
-38.62
-14.48
0.000
2.10
5
4
6
9.44
2.78
-9.34
-2.38
0.094
0.40
6
5
2
-29.33
-6.58
31.80
12.20
2.474
5.61
7
6
5
0.67
11.80
-0.67
-11.42
0.000
0.38
-------- -------Total:
8.719
30.22

Newton's method power flow converged in 2 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.21
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.45 MW
@ line 5-2
9.78 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.57
2 1.150
-2.639
50.00
13.39
3 1.035 -11.435
55.00
13.00
4 0.997
-8.741
5 1.016 -10.963
30.00
18.00
6 0.977 -10.846
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.96
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.06
23.12
-48.05
-13.82
2.010
9.30
2
1
6
43.66
19.45
-41.34
-9.67
2.322
9.78
3
2
3
18.27
1.37
-16.44
1.30
1.836
2.67
4
4
3
38.56
16.40
-38.56
-14.30
0.000
2.10
5
4
6
9.49
2.90
-9.39
-2.49
0.096
0.40
6
5
2
-29.27
-6.45
31.73
12.02
2.455
5.57
7
6
5
0.73
11.94
-0.73
-11.55
0.000
0.39
-------- -------Total:
8.719
30.21

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.49
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.972 p.u. @ bus 6
Voltage Angle
-11.39 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.41 MW
@ line 5-2
9.95 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
44.77
2 1.150
-2.463
50.00
11.57
3 1.042 -11.393
55.00
13.00
4 0.993
-8.734
5 1.022 -10.920
30.00
18.00
6 0.972 -10.826
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.34
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.09
24.27
-48.05
-14.79
2.049
9.47
2
1
6
43.64
20.50
-41.27
-10.55
2.363
9.95
3
2
3
18.18
0.66
-16.37
1.96
1.809
2.63
4
4
3
38.63
17.06
-38.63
-14.96
0.000
2.10
5
4
6
9.41
3.16
-9.32
-2.75
0.097
0.41
6
5
2
-29.41
-5.43
31.82
10.91
2.413
5.48
7
6
5
0.59
13.03
-0.59
-12.57
0.000
0.45
-------- -------Total:
8.730
30.49

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.5
Losses (I^2 * Z)
8.77
29.77
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.988 p.u. @ bus 6
Voltage Angle
-11.56 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.52 MW
@ line 5-2
9.48 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.77
37.62
2 1.150
-3.117
50.00
17.69
3 1.012 -11.563
55.00
13.00
4 1.007
-8.760
5 1.004 -11.105
30.00
18.00
6 0.988 -10.907
50.00
5.00
-------- -------- -------- -------Total:
143.77
55.32
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.99
20.39
-48.06
-11.48
1.927
8.91
2
1
6
43.78
17.23
-41.53
-7.76
2.250
9.48
3
2
3
18.67
3.48
-16.70
-0.61
1.972
2.86
4
4
3
38.30
14.49
-38.30
-12.39
0.000
2.10
5
4
6
9.76
2.56
-9.67
-2.15
0.097
0.41
6
5
2
-28.81
-8.49
31.33
14.22
2.524
5.73
7
6
5
1.19
9.78
-1.19
-9.51
0.000
0.27
-------- -------Total:
8.771
29.77

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.74
30.43
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.971 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.38 MW
@ line 1-6
10.01 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
44.23
2 1.150
-2.619
50.00
12.03
3 1.026 -11.447
55.00
13.00
4 0.996
-8.726
5 1.029 -11.001
30.00
18.00
6 0.971 -10.850
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.26
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.01
23.58
-47.99
-14.23
2.021
9.35
2
1
6
43.73
20.64
-41.35
-10.63
2.377
10.01
3
2
3
18.66
2.06
-16.73
0.74
1.927
2.80
4
4
3
38.27
15.83
-38.27
-13.74
0.000
2.09
5
4
6
9.73
3.86
-9.62
-3.41
0.107
0.45
6
5
2
-29.03
-4.74
31.34
9.97
2.306
5.23
7
6
5
0.97
13.76
-0.97
-13.26
0.000
0.50
-------- -------Total:
8.739
30.43

Newton's method power flow converged in 2 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.2
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.74
30.35
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.973 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.37 MW
@ line 1-6
9.97 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
43.63
2 1.150
-2.675
50.00
12.53
3 1.023 -11.461
55.00
13.00
4 0.997
-8.727
5 1.027 -11.018
30.00
18.00
6 0.973 -10.856
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.16
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.00
23.25
-47.99
-13.95
2.010
9.30
2
1
6
43.74
20.38
-41.37
-10.41
2.367
9.97
3
2
3
18.72
2.32
-16.77
0.50
1.945
2.82
4
4
3
38.23
15.59
-38.23
-13.50
0.000
2.09
5
4
6
9.76
3.83
-9.66
-3.38
0.107
0.45
6
5
2
-28.97
-4.97
31.28
10.21
2.309
5.24
7
6
5
1.03
13.52
-1.03
-13.03
0.000
0.49
-------- -------Total:
8.738
30.35

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.3
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.74
30.45
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.971 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.38 MW
@ line 1-6
10.01 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
44.43
2 1.150
-2.590
50.00
11.86
3 1.028 -11.437
55.00
13.00
4 0.995
-8.726
5 1.028 -10.989
30.00
18.00
6 0.971 -10.846
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.29
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.02
23.73
-48.00
-14.36
2.027
9.37
2
1
6
43.71
20.70
-41.34
-10.68
2.378
10.01
3
2
3
18.60
1.85
-16.69
0.92
1.910
2.77
4
4
3
38.31
16.01
-38.31
-13.92
0.000
2.09
5
4
6
9.69
3.80
-9.58
-3.35
0.106
0.44
6
5
2
-29.08
-4.75
31.40
10.00
2.316
5.26
7
6
5
0.92
13.75
-0.92
-13.25
0.000
0.50
-------- -------Total:
8.737
30.45

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.1
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.74
30.30
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.973 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.36 MW
@ line 1-6
9.94 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.74
43.20
2 1.150
-2.721
50.00
12.89
3 1.020 -11.475
55.00
13.00
4 0.998
-8.728
5 1.027 -11.033
30.00
18.00
6 0.973 -10.863
50.00
5.00
-------- -------- -------- -------Total:
143.74
56.09
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.99
22.99
-47.99
-13.73
2.002
9.26
2
1
6
43.75
20.21
-41.39
-10.27
2.361
9.94
3
2
3
18.78
2.58
-16.82
0.28
1.965
2.85
4
4
3
38.18
15.36
-38.18
-13.28
0.000
2.09
5
4
6
9.80
3.84
-9.70
-3.39
0.108
0.45
6
5
2
-28.91
-5.08
31.22
10.31
2.305
5.23
7
6
5
1.09
13.40
-1.09
-12.92
0.000
0.48
-------- -------Total:
8.740
30.30

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.2
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.73
30.37
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.39 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.54 MW
@ line 5-2
9.77 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
43.52
2 1.150
-2.477
50.00
12.64
3 1.050 -11.386
55.00
13.00
4 0.995
-8.747
5 1.012 -10.889
30.00
18.00
6 0.976 -10.825
50.00
5.00
-------- -------- -------- -------Total:
143.73
56.16
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.14
23.95
-48.10
-14.51
2.042
9.44
2
1
6
43.59
19.57
-41.27
-9.80
2.321
9.77
3
2
3
17.86
0.07
-16.11
2.46
1.743
2.53
4
4
3
38.89
17.57
-38.89
-15.46
0.000
2.11
5
4
6
9.22
2.38
-9.13
-2.00
0.089
0.37
6
5
2
-29.60
-6.80
32.14
12.57
2.540
5.76
7
6
5
0.40
11.57
-0.40
-11.20
0.000
0.37
-------- -------Total:
8.734
30.37

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.0
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.72
30.24
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.976 p.u. @ bus 6
Voltage Angle
-11.43 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.43 MW
@ line 5-2
9.82 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.86
2 1.150
-2.630
50.00
13.14
3 1.034 -11.435
55.00
13.00
4 0.997
-8.738
5 1.018 -10.967
30.00
18.00
6 0.976 -10.845
50.00
5.00
-------- -------- -------- -------Total:
143.72
56.01
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.05
23.22
-48.04
-13.91
2.013
9.31
2
1
6
43.67
19.65
-41.34
-9.83
2.331
9.82
3
2
3
18.32
1.44
-16.48
1.24
1.847
2.68
4
4
3
38.52
16.34
-38.52
-14.24
0.000
2.10
5
4
6
9.52
3.03
-9.42
-2.63
0.097
0.41
6
5
2
-29.24
-6.18
31.68
11.70
2.432
5.52
7
6
5
0.76
12.22
-0.76
-11.82
0.000
0.41
-------- -------Total:
8.719
30.24

Newton's method power flow converged in 3 iterations.


Converged in 0.01 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
56.2
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.2
Losses (I^2 * Z)
8.75
30.37
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.972 p.u. @ bus 6
Voltage Angle
-11.47 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.37 MW
@ line 1-6
10.00 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
43.64
2 1.150
-2.706
50.00
12.54
3 1.019 -11.474
55.00
13.00
4 0.997
-8.726
5 1.029 -11.037
30.00
18.00
6 0.972 -10.862
50.00
5.00
-------- -------- -------- -------Total:
143.75
56.18
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.99
23.15
-47.98
-13.87
2.006
9.28
2
1
6
43.76
20.49
-41.39
-10.49
2.374
10.00
3
2
3
18.84
2.65
-16.86
0.22
1.979
2.87
4
4
3
38.14
15.31
-38.14
-13.22
0.000
2.09
5
4
6
9.84
4.03
-9.73
-3.57
0.110
0.46
6
5
2
-28.88
-4.72
31.16
9.89
2.279
5.17
7
6
5
1.12
13.78
-1.12
-13.28
0.000
0.50
-------- -------Total:
8.748
30.37

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.14
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.978 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.45 MW
@ line 5-2
9.75 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.01
2 1.150
-2.699
50.00
13.86
3 1.031 -11.452
55.00
13.00
4 0.999
-8.741
5 1.015 -10.983
30.00
18.00
6 0.978 -10.853
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.87
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
22.78
-48.04
-13.53
1.999
9.24
2
1
6
43.68
19.23
-41.36
-9.48
2.315
9.75
3
2
3
18.35
1.70
-16.50
1.00
1.857
2.70
4
4
3
38.50
16.10
-38.50
-14.00
0.000
2.10
5
4
6
9.54
2.92
-9.44
-2.51
0.097
0.41
6
5
2
-29.20
-6.60
31.65
12.17
2.451
5.56
7
6
5
0.80
11.78
-0.80
-11.40
0.000
0.38
-------- -------Total:
8.719
30.14

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.06
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.44 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.61 MW
@ line 5-2
9.57 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.74
2 1.150
-2.706
50.00
15.00
3 1.040 -11.440
55.00
13.00
4 1.000
-8.757
5 1.004 -10.947
30.00
18.00
6 0.983 -10.852
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.74
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.11
22.49
-48.11
-13.27
1.994
9.22
2
1
6
43.63
18.25
-41.35
-8.67
2.273
9.57
3
2
3
17.97
0.97
-16.20
1.60
1.770
2.57
4
4
3
38.80
16.72
-38.80
-14.60
0.000
2.11
5
4
6
9.31
2.04
-9.22
-1.67
0.088
0.37
6
5
2
-29.43
-8.11
32.03
14.03
2.608
5.92
7
6
5
0.57
10.18
-0.57
-9.89
0.000
0.29
-------- -------Total:
8.733
30.06

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.9
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.72
30.16
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.977 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.44 MW
@ line 5-2
9.77 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.72
42.21
2 1.150
-2.692
50.00
13.69
3 1.031 -11.451
55.00
13.00
4 0.998
-8.740
5 1.017 -10.985
30.00
18.00
6 0.977 -10.853
50.00
5.00
-------- -------- -------- -------Total:
143.72
55.90
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.04
22.85
-48.04
-13.60
2.001
9.25
2
1
6
43.68
19.36
-41.36
-9.59
2.321
9.77
3
2
3
18.38
1.74
-16.52
0.97
1.864
2.71
4
4
3
38.48
16.07
-38.48
-13.97
0.000
2.10
5
4
6
9.56
3.01
-9.46
-2.60
0.098
0.41
6
5
2
-29.18
-6.43
31.62
11.96
2.436
5.53
7
6
5
0.82
11.96
-0.82
-11.57
0.000
0.39
-------- -------Total:
8.719
30.16

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.8
55.6
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.75
29.97
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.981 p.u. @ bus 6
Voltage Angle
-11.54 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.37 MW
@ line 5-2
9.71 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.75
40.10
2 1.150
-2.982
50.00
15.53
3 1.010 -11.542
55.00
13.00
4 1.003
-8.741
5 1.017 -11.099
30.00
18.00
6 0.981 -10.894
50.00
5.00
-------- -------- -------- -------Total:
143.75
55.62
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
49.96
21.39
-48.01
-12.36
1.953
9.03
2
1
6
43.80
18.70
-41.49
-9.00
2.305
9.71
3
2
3
18.91
3.56
-16.89
-0.62
2.025
2.94
4
4
3
38.11
14.48
-38.11
-12.38
0.000
2.09
5
4
6
9.89
3.42
-9.79
-2.98
0.106
0.44
6
5
2
-28.72
-6.60
31.09
11.97
2.366
5.37
7
6
5
1.28
11.78
-1.28
-11.40
0.000
0.38
-------- -------Total:
8.755
29.97

Newton's method power flow converged in 3 iterations.


Converged in 0.02 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.03
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.45 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.61 MW
@ line 5-2
9.56 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.45
2 1.150
-2.733
50.00
15.25
3 1.039 -11.447
55.00
13.00
4 1.000
-8.758
5 1.003 -10.955
30.00
18.00
6 0.983 -10.855
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.69
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.10
22.33
-48.11
-13.13
1.989
9.20
2
1
6
43.63
18.12
-41.36
-8.57
2.269
9.56
3
2
3
17.99
1.09
-16.21
1.48
1.776
2.58
4
4
3
38.79
16.60
-38.79
-14.48
0.000
2.11
5
4
6
9.33
2.03
-9.24
-1.66
0.088
0.37
6
5
2
-29.40
-8.22
32.01
14.15
2.612
5.93
7
6
5
0.60
10.06
-0.60
-9.78
0.000
0.29
-------- -------Total:
8.734
30.03

Newton's method power flow converged in 3 iterations.


Converged in 0.00 seconds
================================================================================
|
System Summary
|
================================================================================
How many?
--------------------Buses
6
Generators
2
Committed Gens
2
Loads
3
Fixed
3
Dispatchable
0
Shunts
2
Branches
7
Transformers
2
Inter-ties
0
Areas
1

How much?
P (MW)
Q (MVAr)
------------------- ------------- ----------------Total Gen Capacity
250.0
-40.0 to 200.0
On-line Capacity
250.0
-40.0 to 200.0
Generation (actual)
143.7
55.7
Load
135.0
36.0
Fixed
135.0
36.0
Dispatchable
-0.0 of -0.0
-0.0
Shunt (inj)
-0.0
10.3
Losses (I^2 * Z)
8.73
30.00
Branch Charging (inj)
0.0
Total Inter-tie Flow
0.0
0.0

Minimum
------------------------Voltage Magnitude
0.983 p.u. @ bus 6
Voltage Angle
-11.46 deg
@ bus 3
P Losses (I^2*R)
Q Losses (I^2*X)
-

Maximum
-------------------------------1.150 p.u. @ bus 2
0.00 deg
@ bus 1
2.56 MW
@ line 5-2
9.59 MVAr @ line 1-6

================================================================================
|
Bus Data
|
================================================================================
Bus
Voltage
Generation
Load
#
Mag(pu) Ang(deg)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ------- -------- -------- -------- -------- -------1 1.100
0.000
93.73
40.46
2 1.150
-2.772
50.00
15.21
3 1.033 -11.461
55.00
13.00
4 1.001
-8.753
5 1.006 -10.980
30.00
18.00
6 0.983 -10.860
50.00
5.00
-------- -------- -------- -------Total:
143.73
55.67
135.00
36.00
================================================================================
|
Branch Data
|
================================================================================
Brnch
From
To
From Bus Injection
To Bus Injection
Loss (I^2 * Z)
#
Bus
Bus
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
P (MW)
Q (MVAr)
----- ----- ----- -------- -------- -------- -------- -------- -------1
1
4
50.07
22.18
-48.09
-13.01
1.983
9.17
2
1
6
43.66
18.28
-41.38
-8.69
2.277
9.59
3
2
3
18.17
1.55
-16.35
1.09
1.818
2.64
4
4
3
38.65
16.20
-38.65
-14.09
0.000
2.11
5
4
6
9.44
2.32
-9.34
-1.94
0.091
0.38
6
5
2
-29.27
-7.86
31.83
13.66
2.559
5.81
7
6
5
0.73
10.45
-0.73
-10.14
0.000
0.31
-------- -------Total:
8.728
30.00
xmin =
1.1000

1.1500

0.9475

0.9304

5.5000

5.0000