Sunteți pe pagina 1din 3

Sr.

No
1
2
3
4
5
6
7
8
9
10

Alarm Name
eNodeB is out of service
Cell outage
Disable PA
The RRU link is broken
VSWR of the antenna feeder abnormal
Link Broken Between OMM and NE
RRU power-cut alarm
The board is powered off
Wrong board insertion
Board not-in-position(at BPL or RRU)
SCTP Alarm issue

Reason
Media down or Blocked
Cell Blocked
Antenna Jumper Issue
Fiber or Optical Module issue
Antenna Jumper Issue
Media Down
Power shut Down of specfic RRU
Power shut Down of specfic Board
Wrong Board inserted inplace of BPL or 2G,3G RRU fiber connectd at 4G RRU port
BPL board not inserted or RRU not connected
If SCTP is equal or greater than 3

Impact
No Service
No Service at specific sector
No Service at specific sector
No Service at specific sector
No Service at specific sector
No Service
No Service at specific sector
No Service at specific sector
No Service
No Service

S-ar putea să vă placă și