Sunteți pe pagina 1din 6
CES91 Fall 2010 Exam 1 Name. Solution Note: Clearly mark final answers with a box or underline. Please submit your note sheet with your exam Problem 1 (40 points) Consider the A36 plate girder shown below. [= 68,750 in’. Assume that girder self-weight is included in the value of w, and need not be considered separately. If needed, assume C; = 1.0. Assume that limitations related to vertical flange buckling are satisfied. Also, assume that the web is slender. a) Calculate the design flexural capacity, My, of this girder and specify the associated flexural limit state, b) No intermediate transverse stiffeners are used; is this permitted according to AISC limitations? (Note: bearing stiffeners are used but are not shown in the figure.) ©) Assuming that an unstiffened girder is permitted, determine the maximumt design Toad, w,, for this girder, considering shear capacity only. ‘Note: no intermediate transverse stiffeners a * L —- 195! — : wo 1" x 20° hf x 75" x x yee x20" Section A-A Updated 9/18/13 to 2010 AISC Specification Pablem_|a) Table 641-6 (Case 11) a be 22.10 « Apz 0-28 ZA000FS! - 10.8 \ BES Rte 20") imit state . Flange compact , FEB pot a Conbrellin er | 2 ofS") © 16" bse Qu 2 bete = 15's 2117 bpette ne 210 “eK be ree ie onan ite) ay )24o0e = "2-1, = 300" Lee hire G > wile") Ber 16's Ly= 300 Fil wises") (BRB, ° soa "> Lee Bor sacte yl s Fy Ce [Fy ~ (oary yl Lp ; "1b" VY = ‘esi (oo3(3uksi) ( Boga ies* =3¢ = 5.28" u 1 Fee # age te = (10) 12 as : rashuced For = 32.9 ¥S! ole (Se 6.1 [4 ) Lo Reg = = Tze0 + B00 Curt) oe Reg 2 ott 4 ; Seer Eee BEE = \18le 1”? Mn = 9.4 (0-4) ( 323K 00 18 nt) = 48 Bot Kipve [ie cb Mn = 4001 Kip fr ladtal torsimal buck lung (ure) limit state? Updated 9/18/13 to 2010 AISC Specification ) Pevplern |b” b 2 ae = 240 0 No Jok ho <2uo “? FI3-2 unshffened 4ders Ty, Yes, this 1s pected 5) SNe Powte 1¢) ee (ond ty = 260) . h ; 5 (24008) 2 74:4 ~ te aT) ELE = par {slg Y oKsi) . D. [Ole , E . 15ils)leteooks!? = i Ove oe sy (240)? Late esi> tw , *)(0:t0le) Naz 0.9(0 digs (15"42-4 (Helos n= oO 7 pila = 44letps > Ve 2 44.0" Vue woke mize? £1 was OT44 KEE Updated 9/18/13 to 2010 AISC Specification Problem 2 (25 points) y Consider the hybrid plate girder shown. Assume all AISC Pe eee ey 1-4" x 20" Fy = 50 ksi limitations are satisfied. (a) Determine the design shear capacity, ¢,, for vh =1 iB" x76" Fy = 36 ksi (b) Determine the design shear capacity, V,, for ah =1.5 x - |Note: older AISC Specifications explicitly prohibited TFA in hybrid plate girders, so calculations here should be Ibased on web shear buckling capacity only. eee eee ay bos Me" = 243 x20" Fy = S0ksi tw 5/10" a 2bo.\+ . (248)* = Lit > wl (tijen) ° Cans 5 ° Se oye me ae “ Kv S + Cap)? 1.97 [Glee = 123 < 243 ("4151 Lodleqo0e? - 0.2% iy Ksi (243)? (26 Dupe nlozee)-[16.24) Vaz (0.4) ow (Ble kil Th"? Spntity flat: eeued J aur! 4 Cv of web. b) 15 PL 4 kv? (G2- - = 206. 0.)03 i Cv? 2-208 K 2, |eVn= 4 Updated 9/18/13 to 2010 AISC Specification Problem 3 (25 points) Consider the fully composite beam shown below. fe=4 kst normal-weight concrete (145 pef), and the W18x6S is ‘beam, with adjacent beams at 87-0" spacing. The beam span is 30 ft. a) Determine the location of the plastic neutral axis. A992 steel. This is an interior b) Determine the design flexural (positive moment) capacity, Mp, of this beam he be= 29 t=5" F G) bee Ir be & BETH Ibo € ; iia no Fett PUA in slab CAS Tae ET Be (Table I-1> Ase (ab ia™ Lali = Boetllan/fty/4 = 4010 Case ths - Ga linzlSo Fs) 0.854 ksi (1010) A=3l2" << ts=s" Ce A/p= B1zs2 = BUT PNA Is 3.07" fom top ot Slob b> Fyesorsi 4 plas siess dishibu Hove & W- Shape al2z Bi2"/2= 15te" 3" = As Fy Se = 1B4"/2= 2" 7 Asky Dem wu @Mnz 0.4( lob) = Updated 9/18/13 to 2020 AISC Specification = UA tia? sees d 455 * 9S5* ( 9.2" +5"= 156") IZ0T| Kip) = LO0le Kip [0S Kip FH] Problera 4 Provide concise answers (and simple sketches, if you'd like) for the following: (a) @ points) Briefly explain the purpose of Rpg the bending strength reduction factor for plate girders. Rpg accounts fr "bend: buck ling * Aa the. ureb and phe reduced etfechvt cross section, 22- Wel as post buckling. StrengHe Hy Mat reduced Cross section. (b) G points) AISC G3.1 provides some conditions for which tension field action (IFA) is not permitted, What are the reasons for not permitting TFA for each of these conditions? — end panels lack an adjacont panel one Side) +o P anthec He tA¥en Field Strut: = aln> do or (2H /lrjesy)® results 19 a Condition where shffenss are feo widely Spaced t effecnvely develap tension field action — (ec) ld) are based m |ratrtoms tie ee lifted Basler €quatons used & G2 hints Lm ; oe poitt) Brloiy explain how you would detenine whether or not bearing on Applicabils yd) stiffeners are required. = Delmine Concentrated force ¢ reaction force Pu or Ru 7 ere eer e late local web yeld , hfs Cepia buckling. Cif appli cable) capacchy gRn, at conuentaitd lead’ - if @Ra

S-ar putea să vă placă și